Articoli

Restek Soil Gas Samplers

Fewer Connections, Fewer Leaks, Fewer Errors

20 Oct 2023

feature EVSS4129

Restek soil gas samplers are designed for simplicity, reliability, and flexibility, so you can maximize data accuracy while minimizing time, expense, and user error. Available in three popular configurations and a range of flow rates, these samplers are ideal for worry-free soil vapor testing. Because we’ve minimized the number of connections, they are easier to use and have fewer places where leaks can occur.

Simplicity

  • Easy to clean and maintain; screw-in frit filter takes just seconds to replace.
  • Fewer connections mean fewer leaks and a quicker, easier set up.
  • Ships leak tested for out-of-the box performance.

Reliability

  • All-stainless-steel construction means no sample contamination from degrading O-rings.
  • Every unit is leak tested (1 x 10-6 mL/sec) to ensure performance.
  • Individually laser etched with serial number and flow rate—no more guesswork from lost tags or labels.

Flexibility

  • Available in three styles with the most in-demand features.
  • Choose from Siltek-coated or uncoated stainless steel.
  • Comes in three common flow rates to meet most sampling needs.
teaser product style 01
  • Dual gauges
  • Purge port
  • RAVEqc quick-connect outlet fitting
teaser product style 02
  • Dual gauges
  • Purge port
  • ¼” compression outlet fitting
teaser product style 03
  • Single gauge
  • RAVEqc quick-connect outlet fitting

Proven to Be Clean and Inert to Ensure Reliable Soil Gas Sampling Results 

To generate the most accurate data, labs should use soil gas samplers that are clean and inert. To confirm cleanliness, we passed lab air through the samplers and testing it according to Method TO-15A. Inertness was examined by comparing data from a direct measurement of a 200 pptv spiked air canister to data from the same canister when it was connected to the samplers. Results demonstrated that Restek soil gas samplers are extremely clean (0.0 ppb for most compounds) and highly inert with an average recovery for all compounds within 15% of the direct measurement.

Compound Cleanliness
(Avg. ppb)
Inertness
(Avg. %Recovery)
Propylene 0.0 90%
Dichlorodifluoromethane (CFC-12) 0.0 100%
1,2-Dichlorotetrafluoroethane (CFC-114) 0.0 92%
Chloromethane 0.0 95%
Vinyl chloride 0.0 92%
1,3-Butadiene 0.0 105%
Bromomethane 0.0 103%
Chloroethane 0.0 95%
Trichlorofluoromethane (CFC-11) 0.0 103%
1,1-Dichloroethene 0.0 100%
Ethanol* 5.1 93%
Carbon disulfide* 0.8 96%
1,1,2-Trichlorotrifluoroethane 0.0 100%
Acrolein 0.0 96%
Isopropyl alcohol 0.0 118%
Methylene chloride* 0.9 111%
Acetone* 0.5 89%
trans-1,2-Dichloroethene 0.0 98%
Hexane 0.0 114%
1,1-Dichloroethane 0.0 92%
Vinyl acetate 0.0 104%
cis-1,2-Dichloroethene 0.0 107%
Cyclohexane 0.0 106%
Chloroform 0.0 92%
Carbon tetrachloride 0.0 96%
Ethyl acetate 0.0 111%
Tetrahydrofuran 0.0 105%
1,1,1-Trichloroethane 0.0 100%
2-Butanone (MEK) 0.0 95%
Heptane 0.0 104%
Benzene 0.0 102%
1,2-Dichloroethane 0.0 108%
Trichloroethylene 0.0 100%
1,2-Dichloropropane 0.0 102%
Bromodichloromethane 0.0 94%
Methyl methacrylate 0.0 100%
1,4-Dioxane 0.0 110%
cis-1,3-Dichloropropene 0.0 95%
Toluene 0.0 98%
4-Methyl-2-2pentanone (MIBK) 0.1 104%
Tetrachloroethene 0.0 102%
trans-1,3-Dichloropropene 0.0 99%
1,1,2-Trichloroethane 0.0 102%
Dibromochloromethane 0.0 98%
1,2-Dibromoethane 0.0 95%
2-Hexanone (MBK) 0.0 97%
Chlorobenzene 0.0 98%
Ethylbenzene 0.0 102%
m– & p-Xylene 0.0 100%
o-Xylene 0.0 104%
Styrene 0.1 100%
Bromoform 0.0 101%
1,1,2,2-Tetrachloroethane 0.0 102%
4-Ethyltoluene 0.0 103%
1,3,5-Trimethylbenzene 0.0 110%
1,2,4-Trimethylbenzene 0.0 95%
1,3-Dichlorobenzene 0.0 99%
1,4-Dichlorobenzene 0.0 106%
Benzyl chloride 0.0 99%
1,2-Dichlorobenzene 0.0 99%
Hexachlorobutadiene 0.0 99%
1,2,4-Trichlorobenzene 0.0 104%
Naphthalene 0.0 103%

*Compound present in lab air during testing.

teaser article EVSS4129 order info header
Dual Gauge with Purge Port and RAVEqc Quick-Connect Outlet Fitting 180 mL/min, uncoated (cat.# 27255)
180 mL/min, Siltek coated (cat.# 27256)
150 mL/min, uncoated (cat.# 27257)
150 mL/min, Siltek coated (cat.# 27258)
100 mL/min, uncoated (cat.# 27259)
100 mL/min, Siltek coated (cat.# 27260)
Dual Gauge with Purge Port and ¼” Compression Outlet Fitting 180 mL/min, uncoated (cat.# 27249)
180 mL/min, Siltek coated (cat.# 27250)
150 mL/min, uncoated (cat.# 27251)
150 mL/min, Siltek coated (cat.# 27252)
100 mL/min, uncoated (cat.# 27253)
100 mL/min, Siltek coated (cat.# 27254)
Single Gauge (No Purge Port) with RAVEqc Quick-Connect Outlet Fitting 180 mL/min, uncoated (cat.# 27243)
180 mL/min, Siltek coated (cat.# 27244)
150 mL/min, uncoated (cat.# 27245)
150 mL/min, Siltek coated (cat.# 27246)
100 mL/min, uncoated (cat.# 27247)
100 mL/min, Siltek coated (cat.# 27248)

Related Products


Discontinued: Kit di bottiglie per il campionamento dell’aria con valvola trattata in Siltek e scatola protettiva
Valvola maschio RAVEqc a connessione rapida per raccordo tubo da 1/4", corto (1,23")
Canister per il campionamento dell’aria TO-Can, 1 l, con valvola RAVE+ 3 porte con manometro
Canister per il campionamento dell’aria SilcoCan, 1 l, con valvola RAVE+ trattata in Siltek 3 porte con manometro
Discontinued: Frit 2µm per campionatori d’aria personali Aura, cad.
Frit 2µm per campionatori d’aria personali Aura, 10 pz.

Autori

  • Restek Corporation

    Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions.

    View Articles
EVSS4129
Versione: B