Articoli

ASTM Petrochemical Method Chromatography Product Guide

Proven, Integrated Solutions and Veteran Expertise for Your Petrochemical & Chemical Analyses

14 Jul 2026

feature PCAR2082

Restek is your ideal partner for integrated petrochemical solutions, and the following ASTM method product guide will help you quickly pick the right GC columns and reference standards for SimDist, DHA, finished gasoline, and other common petroleum analyses.

If you have any questions or need more information contact one of our in-house petroleum experts for assistance.

(High-Temperature) Simulated Distillation (SimDist)
Method #Method TitleRestek Column(s)Restek Reference
Standard(s)
Chromatogram#
D2887Standard Test Method for Boiling Range Distribution of Petroleum Fractions by Gas Chromatography (C5–C44)MXT-2887, Siltek-treated stainless steel
10 m x 0.53 mm x 2.65 µm
– cat.# 70199 or MXT-1HT SimDist, Siltek-treated stainless steel
10 m x 0.53 mm x 2.65 µm
– cat.# 70132 or Rtx-2887 Column
10 m x 0.53 mm x 2.65 µm
– cat.# 10199  
ASTM D2887-12 Calibration Standards
– cat.# 31674 Polywax Standards
– cat.# 36224–36227 D2887 Calibration Mix
– cat.# 31222
GC_PC00750
D2887B AcceleratedStandard Test Method for Boiling Range Distribution of Petroleum Fractions by Gas Chromatography (C5–C44)MXT-1HT SimDist Column
10 m x 0.53 mm x 0.88 µm
– cat.# 70134 or MXT-1HT SimDist Column
5 m x 0.53 mm x 2.65 µm
custom column #573912
ASTM D2887-12 Calibration Standards
– cat.# 31674 Polywax Standards
– cat.# 36224–36227 D2887 Calibration Mix
– cat.# 31222
GC_PC1303
D7213Standard Test Method for Boiling Range Distribution of Petroleum Distillates in the Boiling Range from 100 to 615 °C by Gas Chromatography (C5–C60)MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.10 µm
– cat.# 70112 or MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.20 µm
– cat.# 70115 or MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.88 µm
– cat.# 70131
Request todayGC_PC1285 GC_PC1191
D6352Standard Test Method for Boiling Range Distribution of Petroleum Distillates in Boiling Range from 174 to 700 °C by Gas Chromatography (C10–C90)MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.10 µm
– cat.# 70112 or MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.20 µm
– cat.# 70115
Polywax Standards
– cat.# 36224–36227
GC_PC1188
D7398Standard Test Method for Boiling Range Distribution of Fatty Acid Methyl Esters (FAME) in the Boiling Range from 100 to
615 °C by Gas Chromatography
MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.88 µm
– cat.# 70131
Polywax Standards
– cat.# 36224–36227  
GC_PC1285
D7500Standard Test Method for Determination of Boiling Range Distribution of Distillates and Lubricating Base Oils in Boiling Range from 100 to 735 °C by Gas Chromatography (C7–C110)MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.10 µm
– cat.# 70112 or MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.20 µm
– cat.# 70115
  Standards
– cat.# 36224–36227  
GC_PC1164 GC_PC1165
D7169Standard Test Method for Boiling Point Distribution of Samples with Residues Such as Crude Oils and Atmospheric and Vacuum Residues by High-Temperature Gas ChromatographyMXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.10 µm
– cat.# 70112 or MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.20 µm
– cat.# 70115
Polywax Standards
– cat.# 36224–36227  
GC_PC1308
D7096 (replaces D3710)Standard Test Method for Determination of the Boiling Range Distribution of Gasoline by Wide-Bore Capillary Gas ChromatographyMXT-1, Siltek-treated stainless steel
15 m x 0.53 mm x 5.00 µm
– cat.# 70177 or MXT-1, Siltek-treated stainless steel
30 m x 0.53 mm x 5.00 µm
– cat.# 70179
Request today or D3710-95 Calibration Mix
– cat.# 31223
GC_PC1326 GC_PC1327 GC_PC1328
Detailed Hydrocarbon Analysis (DHA)
Method #Method TitleRestek Column(s)Restek Reference
Standard(s)
Chromatogram#
D5134Standard Test Method for Detailed Analysis of Petroleum Naphthas through n-Nonane by Capillary Gas ChromatographyRtx-DHA-50
50 m x 0.20 mm x 0.50 µm
– cat.# 10147
Request todayGC_PC1318 GC_PC1319 GC_PC1320
D6729Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 100-Meter Capillary High-Resolution Gas ChromatographyRtx-DHA-100
100 m x 0.25 mm x 0.50 µm
– cat.# 10148
DHA Standards
– cat.# 33034
– cat.# 30725
cat.# 30726
cat.# 30727
cat.# 30728
cat.# 30730
GC_PC1322 GC_PC1323 GC_PC1324 GC_PC1325 GC_PC1330
D6730Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 100–Meter Capillary (with precolumn) High-Resolution Gas ChromatographyRtx-DHA-100
100 m x 0.25 mm x 0.50 µm
– cat.# 10148 and Rtx-5 DHA Tuning
5 m x 0.25 mm x 1.00 µm
– cat.# 10165
DHA Standards
– cat.# 33034
– cat.# 30725
cat.# 30726
cat.# 30727
cat.# 30728
cat.# 30730
GC_PC1284
D6733Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 50-Meter Capillary High-Resolution Gas ChromatographyRtx-DHA-50
50 m x 0.20 mm x 0.50 µm
– cat.# 10147
DHA Standards
– cat.# 33034
– cat.# 30725
cat.# 30726
cat.# 30727
cat.# 30728
cat.# 30730
 
Finished Gasoline
Method #Method TitleRestek Column(s)Restek Reference
Standard(s)
Chromatogram#
D3606Standard Test Method for Determination of Benzene and Toluene in Spark Ignition Fuels by Gas ChromatographyD3606 Packed GC Column Set, Sulfinert, General Configuration
cat.#83606-800

Specified in the D3606 method addendum—includes:
– Column 1: Backflush column
6′ (1.8 m), 1/8″ OD, 2.0 mm ID

and
– Column 2: proprietary packing
16′ (4.9 m), 1/8″ OD, 2.0 mm ID


D3606 GC Capillary Column Set
cat.#118-D3606
– Column 1: Rxi-1ms Capillary Column, 
30 m, 0.25 mm ID, 0.50 µm
(cat.# 13338)

and

 – Column 2: Stabilwax GC Capillary Column, 60 m, 0.32 mm ID, 1.00 µm (cat.# 10657)
Request todayPC01121
D4815Standard Test Method for Determination of MTBE, ETBE, TAME, DIPE, tertiary-Amyl Alcohol, and C1 to C4 Alcohols in Gasoline by Gas Chromatography (Oxygenates)Micropacked with 20% TCEP on 80/100 Chromosorb PAW
0.56 m x 0.75 mm ID x 1/16″ OD
– cat.# 19040 and Rtx-1
30 m x 0.53 mm x 3.00 µm
– cat.# 10185
Request todayGC_PC00194
D5580Standard Test Method for Determination of Benzene, Toluene, Ethylbenzene, p/m-Xylene, o-Xylene, C9 and Heavier Aromatics, and Total Aromatics in Finished Gasoline by Gas ChromatographyMicropacked with 20% TCEP on 80/100 Chromosorb PAW
0.56 m x 0.75 mm ID x 1/16″ OD
– cat.# 19040 and Rtx-1
30 m x 0.53 mm x 5.00 µm
– cat.# 10179
Request today 
D5501Standard Test Method for Determination of Ethanol Content of Denatured Fuel Ethanol by Gas ChromatographyRtx-DHA-150
150 m x 0.25 mm x 1.00 µm
– cat.# 10149 or Rtx-DHA-100
100 m x 0.25 mm x 0.50 µm
– cat.# 10148
Request todayGC_PC1144
D8071Standard Test Method for Determination of Hydrocarbon Group Types and Select Hydrocarbon and Oxygenate Compounds in Automotive Spark-Ignition Engine Fuel Using Gas Chromatography with Vacuum Ultraviolet Absorption Spectroscopy Detection (GC-VUV)Rxi-1ms
30 m x 0.25 mm x 0.25 µm
– cat.# 13323  
Request todayGC_PC1358
Biodiesel
Method #Method TitleRestek Column(s)Restek Reference
Standard(s)
Chromatogram#
D6584Test Method for Determination of Free and Total Glycerin in B-100 Biodiesel Methyl Esters by Gas ChromatographyMXT-Biodiesel TG, Siltek-treated stainless steel
14 m x 0.53 mm x 0.16 µm
with 2 m Integra-Gap
– cat.# 70289 or MXT-Biodiesel TG, Siltek-treated stainless steel
15 m x 0.32 mm x 0.10 µm
with 2 m x 0.53 mm retention gap
– cat.# 70291 or Rtx-Biodiesel TG
15 m x 0.32 mm x 0.10 µm
with 2 m x 0.53 mm retention gap
– cat.# 10293
Biodiesel Standards
– cat.# 31880
– cat.# 33020–33026
– cat.# 33032–33033
GC_PC1293 GC_PC00969
Jet Fuel
Method #Method TitleRestek Column(s)Restek Reference
Standard(s)
Chromatogram#
D8267Standard Test Method for Determination of Saturated Hydrocarbon, Aromatic, and Diaromatic Content of Aviation Turbine Fuels Using Gas Chromatography with Vacuum Ultraviolet Absorption Spectroscopy Detection (GC-VUV)Rxi-1ms
30 m x 0.25 mm x 0.25 µm
– cat.# 13323  
Request todayGC_PC1359
Natural Gas
Method #Method TitleRestek Column(s)Restek Reference
Standard(s)
Chromatogram#
D1945Standard Test Method for Analysis of Natural Gas by Gas ChromatographyMXT-Msieve 5A, Siltek-treated stainless steel
30 m x 0.53 mm x 50 µm
– cat.# 79723-273 and MXT-Q-BOND, Siltek-treated stainless steel
30 m x 0.53 mm x 20 µm
– cat.# 79716-273
Natural Gas Standards
– cat.# 34438–34440
GC_PC1182
Refinery Gas
Method #Method TitleRestek Column(s)Restek Reference
Standard(s)
Chromatogram#
D2163Standard Test Method for Determination of Hydrocarbons in Liquefied Petroleum (LP) Gases and Propane/Propene Mixtures by Gas ChromatographyRt-Alumina BOND/Na2SO4
50 m x 0.53 mm x 10 µm
– cat.# 19756
Refinery Gas Standards
– cat.# 34441–34443
GC_PC1309 GC_PC1310
UOP 539Standard Practice for Analysis of Reformed Gas by Gas Chromatography2abc Refinery Gas Packed Column Set
– cat.# 88000-875 or MXT-Msieve 5A, Siltek-treated stainless steel
30 m x 0.53 mm x 50 µm
– cat.# 79723-273 and MXT-Q-BOND, Siltek-treated stainless steel
30 m x 0.53 mm x 20 µm
– cat.# 79716
Request todayGC_PC1182
Impurities
Method #Method TitleRestek Column(s)Restek Reference
Standard(s)
Chromatogram#
D2593Standard Test Method for Butadiene Purity and Hydrocarbon Impurities by Gas ChromatographyRt-Alumina BOND/MAPD
50 m x 0.53 mm x 10 µm
– cat.# 19778
Refinery Gas Standard #5
– cat.# 34443
GC_PC1202
D2712Standard Test Method for Hydrocarbon Traces in Propylene Concentrates by Gas ChromatographyRt-Alumina BOND/KCl
50 m x 0.53 mm x 10 µm
– cat.# 19760
Refinery Gas Standard #5
– cat.# 34443
GC_PC01142
D6159Standard Test Method for Determination of Hydrocarbon Impurities in Ethylene by Gas ChromatographyRt-Alumina BOND/KCl
50 m x 0.53 mm x 10 µm
– cat.# 19760 and Rtx-1
30 m x 0.53 mm x 5.00 µm
– cat.# 10179
Refinery Gas Standard #5
– cat.# 34443
GC_PC01110
D5441Standard Test Method for Analysis of Methyl Tert-Butyl Ether (MTBE) by Gas ChromatographyRtx-DHA-100
100 m x 0.25 mm x 0.50 µm
– cat.# 10148 or Rtx-DHA-50
50 m x 0.20 mm x 0.50 µm
– cat.# 10147 or Rtx-DHA-150
150 m x 0.25 mm x 1.0 µm
– cat.# 10149
Request todayGC_PC1268 GC_PC1270 GC_PC1269
D8311Test Method for Impurities in Monoethylene Glycol by Gas Chromatography with NormalizationRxi-624Sil MS
30 m x 0.32 mm ID x 1.80 µm
– cat.# 13870
Request today
E2409Test Method for Glycol Impurities in Mono-, Di-, Tri- and Tetraethylene Glycol (Gas Chromatographic Method)Rtx-Wax
15 m x 0.53 mm ID x 1.00 µm
– cat.# 12452
Request today
Sulfur
Method #Method TitleRestek Column(s)Restek Reference
Standard(s)
Chromatogram#
D6228Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Flame Photometric DetectionRtx-1
60 m x 0.53 mm x 7.00 µm
– cat.# 10193 or MXT-1, Siltek-treated stainless steel
60 m x 0.53 mm x 7.00 µm
– cat.# 70193 or Rtx-1
60 m x 0.32 mm x 5.0 µm
– cat.# 10180
Request todayGC_PC1223
D5623Standard Test Method for Sulfur Compounds in Light Petroleum Liquids by Gas Chromatography and Sulfur Selective DetectionRtx-1
30 m x 0.32 mm x 4.00 µm
– cat.# 10198
Request today
(gasliquid)
GC_PC1271 GC_PC00198
Industrial Chemicals
Method #Method TitleRestek Column(s)Restek Reference
Standard(s)
Chromatogram#
D5917Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and External CalibrationStabilwax
60 m x 0.32 mm x 0.25 µm
– cat.# 10627
Request todayGC_PC1355
GC_PC1352
GC_PC1353
GC_PC1354
D7266Standard Test Method for Analysis of Cyclohexane by Gas Chromatography (External Standard)Rtx-DHA-100
100 m x 0.25 mm x 0.50 µm
– cat.# 10148
Request todayGC_PC1356
D7504Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and Effective Carbon NumberStabilwax
60 m x 0.32 mm x 0.25 µm
– cat.# 10627
Request todayGC_PC1352
GC_PC1353
GC_PC1354
GC_PC1355
D7871Standard Test Method for Analysis of Cyclohexane by Gas Chromatography (Effective Carbon Number)Rtx-DHA-100
100 m x 0.25 mm x 0.50 µm
– cat.# 10148
Request todayGC_PC1356
D7011Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography and Sulfur Selective DetectionRtx-WAX
30 m x 0.32 mm x 1.00 µm
– cat.# 12454
Request todayGC_PC1357
D6144Standard Test Method for Analysis of AMS (a-Methylstyrene) by Capillary Gas ChromatographyRtx-1
60 m x 0.32 mm x 1.00 µm
– cat.# 10157
Request todayGC_PC1351
D7057Standard Test Method for Analysis of Isopropylbenzene (Cumene) by Gas Chromatography (External Standard)Rtx-1
60 m x 0.32 mm x 1.00 µm
– cat.# 10157
Request todayGC_PC1350
D5310Standard Test Method for Tar Acid Composition by Capillary Gas ChromatographyRxi 5MS
30 m x 0.53 mm x 1.00 µm
– cat.# 13423
Request todayGC_PC1371
D3329Standard Test Method for Purity of Methyl Isobutyl Ketone by Gas ChromatographyStabilwax
30 m x 0.25 mm x 1.00 µm
– cat. #10655
Request todayGC_PC1373
D7090Standard Test Method for Purity of Isophorone by Capillary Gas ChromatographyRtx – WAX
30 m x 0.32 mm x 0.5 µm
– cat.# 12439
Request todayGC_PC1369
D3893Standard Test Method for Purity of Methyl Amyl Ketone and Methyl Isoamyl Ketone by Gas ChromatographyStabilwax
30 m x 0.53 mm x 1.00 µm
– cat. #10655
Request today 
D6142Test Method Analysis of Phenol by Capillary Gas ChromatographyStabilwax-DA
50 m x 0.32 mm ID x 0.50 µm
– cat.# 11042-105
Request today
D8266Test Method for Analysis of Bisphenol A (4,4′-Isopropylidenediphenol)Ultra C18
5 µm x 250 x 4.6 mm
– cat.# 9174575
Request today

Autori

  • Restek Corporation

    Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions.

    View Articles
PCAR2082
Versione: L