{"id":2999,"date":"2025-07-30T19:59:16","date_gmt":"2025-07-30T19:59:16","guid":{"rendered":"https:\/\/discover.restek.com\/?p=2999"},"modified":"2026-09-11T14:13:23","modified_gmt":"2026-09-11T14:13:23","slug":"which-syringe-filters-are-compatible-with-my-solvents-or-matrix","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/faq\/gnot5167\/which-syringe-filters-are-compatible-with-my-solvents-or-matrix","title":{"rendered":"Which syringe filters are compatible with my solvents or matrix?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Please use the Syringe Filter Membrane Selection Guide (below) and the&nbsp;<a href=\"https:\/\/www.restek.com\/articles\/syringe-filters-solvent-compatibility-chart\" target=\"_blank\" rel=\"noopener\">Syringe Filter Solvent Compatibility Chart<\/a>.&nbsp;Best practices dictate verifying compatibility prior to use.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Syringe Filter Membrane Selection Guide<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>Membrane<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Properties<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Applications<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Incompatible with<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">Cellulose Acetate<\/td><td class=\"has-text-align-left\" data-align=\"left\">hydrophilic<\/td><td class=\"has-text-align-left\" data-align=\"left\">aqueous solutions<\/td><td class=\"has-text-align-left\" data-align=\"left\">organic solvents<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Nylon<\/td><td class=\"has-text-align-left\" data-align=\"left\">hydrophilic, low protein binding<\/td><td class=\"has-text-align-left\" data-align=\"left\">bases, HPLC solvents, alcohols, aromatic hydrocarbons<\/td><td class=\"has-text-align-left\" data-align=\"left\">acids, aggressive halogenated hydrocarbons, proteins<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">PES<\/td><td class=\"has-text-align-left\" data-align=\"left\">hydrophilic, low protein binding, fast flow rates<\/td><td class=\"has-text-align-left\" data-align=\"left\">filtration of butters &amp; culture media<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">PTFE<\/td><td class=\"has-text-align-left\" data-align=\"left\">hydrophobic<\/td><td class=\"has-text-align-left\" data-align=\"left\">organic solvents, acids, alcohols, bases, aromatics<\/td><td class=\"has-text-align-left\" data-align=\"left\">aqueous samples without pre-wetting (to avoid high back pressure)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">PVDF<\/td><td class=\"has-text-align-left\" data-align=\"left\">hydrophilic, low protein binding<\/td><td class=\"has-text-align-left\" data-align=\"left\">alcohols, biomolecules<\/td><td class=\"has-text-align-left\" data-align=\"left\">bases, esters, ethers, ketones<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Polypropylene (PP)<\/td><td class=\"has-text-align-left\" data-align=\"left\">hydrophilic, low protein binding, high solvent resistance, good thermal compatibility<\/td><td class=\"has-text-align-left\" data-align=\"left\">biological samples, solvents, aqueous solutions<\/td><td class=\"has-text-align-left\" data-align=\"left\">strong oxidizing acids, halogenated and aromatic hydrocarbons<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Hydrophilic applications: cellulose acetate, nylon, PES, PVDF, PP<br>Hydrophobic applications: PTFE<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Please use the Syringe Filter Membrane Selection Guide (below) and the&nbsp;Syringe Filter Solvent Compatibility Chart.&nbsp;Best practices dictate verifying compatibility prior to use. Syringe Filter Membrane Selection Guide Membrane Properties Applications Incompatible with Cellulose Acetate hydrophilic aqueous solutions organic solvents Nylon hydrophilic, low protein binding bases, HPLC solvents, alcohols, aromatic hydrocarbons acids, aggressive halogenated hydrocarbons, proteins&#8230;<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[23],"tags":[2688,2712],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-2999","post","type-post","status-publish","format-standard","hentry","category-faq","tag-faq-sample-preparation","tag-faq-syringe-filters"],"acf":[],"taxonomy_info":{"category":[{"value":23,"label":"FAQ"}],"post_tag":[{"value":2688,"label":"FAQ: Sample Preparation"},{"value":2712,"label":"FAQ: Syringe Filters"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/it\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":23,"name":"FAQ","slug":"faq","term_group":0,"term_taxonomy_id":23,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":23,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq","category_parent":0}],"tag_info":[{"term_id":2688,"name":"FAQ: Sample Preparation","slug":"faq-sample-preparation","term_group":0,"term_taxonomy_id":2688,"taxonomy":"post_tag","description":"Browse frequently asked questions for sample preparation products.","parent":0,"count":53,"filter":"raw"},{"term_id":2712,"name":"FAQ: Syringe Filters","slug":"faq-syringe-filters","term_group":0,"term_taxonomy_id":2712,"taxonomy":"post_tag","description":"Browse frequently asked questions for syringe filters.","parent":0,"count":5,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/2999","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=2999"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/2999\/revisions"}],"predecessor-version":[{"id":103186,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/2999\/revisions\/103186"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=2999"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=2999"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=2999"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=2999"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=2999"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=2999"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=2999"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=2999"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=2999"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}