{"id":3492,"date":"2025-07-31T18:12:32","date_gmt":"2025-07-31T18:12:32","guid":{"rendered":"https:\/\/discover.restek.com\/?p=3492"},"modified":"2025-12-08T18:57:22","modified_gmt":"2025-12-08T18:57:22","slug":"what-critical-orifice-should-i-select-based-on-my-canister-size-and-sampling-time-requirements","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/faq\/gnot4980\/what-critical-orifice-should-i-select-based-on-my-canister-size-and-sampling-time-requirements","title":{"rendered":"What critical orifice should I select based on my canister size and sampling time requirements?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The following table lists the recommended orifice diameters, associated flow rate ranges, and canister volumes and sampling times:<\/p>\n\n\n\n<figure class=\"wp-block-table aligncenter\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"5\"><strong>Canister Volume\/Sampling Time<\/strong><\/td><td>&nbsp;<\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Orifice<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Siltek-Treated<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Stainless Steel<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>400 cc<\/strong><\/td><td><strong>1 Liter<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>3 Liter<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>6 Liter<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>15 Liter<\/strong><\/td><td><strong>Flow<\/strong><\/td><td><strong>Size<\/strong>       <\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>cat.#<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>cat.#<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">8 hour<\/td><td>24 hour<\/td><td class=\"has-text-align-center\" data-align=\"center\">48 hour<\/td><td class=\"has-text-align-center\" data-align=\"center\">125 hour<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u2014<\/td><td>0.5\u20132 mL\/min<\/td><td>0.0008&#8243;<\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"http:\/\/restek.com\/p\/24217\" target=\"_blank\" rel=\"noopener\">24217<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"http:\/\/restek.com\/p\/24216\" target=\"_blank\" rel=\"noopener\">24216<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">2 hour<\/td><td>4 hour<\/td><td class=\"has-text-align-center\" data-align=\"center\">12 hour<\/td><td class=\"has-text-align-center\" data-align=\"center\">24 hour<\/td><td class=\"has-text-align-center\" data-align=\"center\">60 hour<\/td><td>2\u20134 mL\/min<\/td><td>0.0012&#8243;<\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"http:\/\/restek.com\/p\/24160\" target=\"_blank\" rel=\"noopener\">24160<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"http:\/\/restek.com\/p\/24165\" target=\"_blank\" rel=\"noopener\">24165<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">1 hour<\/td><td>2 hour<\/td><td class=\"has-text-align-center\" data-align=\"center\">6 hour<\/td><td class=\"has-text-align-center\" data-align=\"center\">12 hour<\/td><td class=\"has-text-align-center\" data-align=\"center\">30 hour<\/td><td>4\u20138 mL\/min<\/td><td>0.0016&#8243;<\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"http:\/\/restek.com\/p\/24161\" target=\"_blank\" rel=\"noopener\">24161<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"http:\/\/restek.com\/p\/24166\" target=\"_blank\" rel=\"noopener\">24166<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">\u2014<\/td><td>1 hour<\/td><td class=\"has-text-align-center\" data-align=\"center\">4 hour<\/td><td class=\"has-text-align-center\" data-align=\"center\">8 hour<\/td><td class=\"has-text-align-center\" data-align=\"center\">20 hour<\/td><td>8\u201315 mL\/min<\/td><td>0.0020&#8243;<\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"http:\/\/restek.com\/p\/24162\" target=\"_blank\" rel=\"noopener\">24162<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"http:\/\/restek.com\/p\/24167\" target=\"_blank\" rel=\"noopener\">24167<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">\u2014<\/td><td>\u2014<\/td><td class=\"has-text-align-center\" data-align=\"center\">2 hour<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 hour<\/td><td class=\"has-text-align-center\" data-align=\"center\">8 hour<\/td><td>15\u201330 mL\/min<\/td><td>0.0030&#8243;<\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"http:\/\/restek.com\/p\/24163\" target=\"_blank\" rel=\"noopener\">24163<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">\u2014<\/td><td>\u2014<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 hour<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.5 hour<\/td><td class=\"has-text-align-center\" data-align=\"center\">4 hour<\/td><td>30\u201380 mL\/min<\/td><td>0.0060&#8243;<\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"http:\/\/restek.com\/p\/24164\" target=\"_blank\" rel=\"noopener\">24164<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"http:\/\/restek.com\/p\/24169\" target=\"_blank\" rel=\"noopener\">24169<\/a><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">\u2014<\/td><td>\u2014<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u2014<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.5 hour<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 hour<\/td><td>80\u2013340 mL\/min<\/td><td>0.0090&#8243;<\/td><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"http:\/\/restek.com\/p\/22101\" target=\"_blank\" rel=\"noopener\">22101<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\">\u2014<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The following table lists the recommended orifice diameters, associated flow rate ranges, and canister volumes and sampling times: Canister Volume\/Sampling Time &nbsp; Orifice Siltek-Treated Stainless Steel 400 cc 1 Liter 3 Liter 6 Liter 15 Liter Flow Size cat.# cat.# 8 hour 24 hour 48 hour 125 hour \u2014 0.5\u20132 mL\/min 0.0008&#8243; 24217 24216 2&#8230;<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[2808],"tags":[2677,2691],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2371,2377],"resource-technique":[],"ppma_author":[414],"class_list":["post-3492","post","type-post","status-publish","format-standard","hentry","category-faq","tag-faq-air-sampling","tag-faq-air-sampling-canisters","product-library-air-gas-sampling-products","product-library-canisters-accessories"],"acf":[],"taxonomy_info":{"category":[{"value":2808,"label":"FAQ"}],"post_tag":[{"value":2677,"label":"FAQ: Air Sampling"},{"value":2691,"label":"FAQ: Air Sampling Canisters"}],"product-library":[{"value":2371,"label":"Air &amp; Gas Sampling Products"},{"value":2377,"label":"Canisters &amp; Accessories"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/it\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":2808,"name":"FAQ","slug":"faq","term_group":0,"term_taxonomy_id":2808,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":2808,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq","category_parent":0}],"tag_info":[{"term_id":2677,"name":"FAQ: Air Sampling","slug":"faq-air-sampling","term_group":0,"term_taxonomy_id":2677,"taxonomy":"post_tag","description":"Browse frequently asked questions for air sampling products.","parent":0,"count":36,"filter":"raw"},{"term_id":2691,"name":"FAQ: Air Sampling Canisters","slug":"faq-air-sampling-canisters","term_group":0,"term_taxonomy_id":2691,"taxonomy":"post_tag","description":"Browse frequently asked questions for air sampling canisters.","parent":0,"count":5,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/3492","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=3492"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/3492\/revisions"}],"predecessor-version":[{"id":71037,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/3492\/revisions\/71037"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=3492"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=3492"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=3492"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=3492"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=3492"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=3492"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=3492"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=3492"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=3492"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}