{"id":39927,"date":"2026-07-14T15:00:00","date_gmt":"2026-07-14T15:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/astm-petrochemical-method-chromatography-product-guide\/"},"modified":"2026-09-08T15:41:54","modified_gmt":"2026-09-08T15:41:54","slug":"astm-petrochemical-method-chromatography-product-guide","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/articles-fr\/pcar2082\/astm-petrochemical-method-chromatography-product-guide","title":{"rendered":"ASTM Petrochemical Method Chromatography Product Guide"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Restek is your ideal partner for integrated petrochemical solutions, and the following ASTM method product guide will help you quickly pick the right GC columns and reference standards for SimDist, DHA, finished gasoline, and other common petroleum analyses.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If you have any questions or need more information <a href=\"https:\/\/restek.com\/contact-us\" target=\"_blank\" data-type=\"link\" data-id=\"restek.com\/contact-us\" rel=\"noreferrer noopener\">contact<\/a> one of our in-house petroleum experts for assistance.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"5\"><strong>(High-Temperature) Simulated Distillation (SimDist)<\/strong><\/td><\/tr><tr><td><strong>Method #<\/strong><\/td><td><strong>Method Title<\/strong><\/td><td><strong>Restek Column(s)<\/strong><\/td><td><strong>Restek Reference<br>Standard(s)<\/strong><\/td><td><strong>Chromatogram#<\/strong><\/td><\/tr><tr><td>D2887<\/td><td>Standard Test Method for Boiling Range Distribution of Petroleum Fractions by Gas Chromatography (C5\u2013C44)<\/td><td>MXT-2887, Siltek-treated stainless steel<br>10 m x 0.53 mm x 2.65 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70199\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70199<\/a> <em>or<\/em> MXT-1HT SimDist, Siltek-treated stainless steel<br>10 m x 0.53 mm x 2.65 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70132\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70132<\/a> <em>or<\/em> Rtx-2887 Column<br>10 m x 0.53 mm x 2.65 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10199\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10199<\/a> &nbsp;<\/td><td>ASTM D2887-12 Calibration Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/31674\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 31674<\/a> Polywax Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/36224\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 36224\u201336227<\/a> D2887 Calibration Mix<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/31222\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 31222<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC00750\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC00750<\/a><\/td><\/tr><tr><td>D2887B Accelerated<\/td><td>Standard Test Method for Boiling Range Distribution of Petroleum Fractions by Gas Chromatography (C5\u2013C44)<\/td><td>MXT-1HT SimDist Column<br>10 m x 0.53 mm x 0.88 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70134\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70134<\/a> <em>or<\/em> MXT-1HT SimDist Column<br>5 m x 0.53 mm x 2.65 \u00b5m<br>custom column #573912<\/td><td>ASTM D2887-12 Calibration Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/31674\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 31674<\/a> Polywax Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/36224\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 36224\u201336227<\/a> D2887 Calibration Mix<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/31222\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 31222<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1303\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1303<\/a><\/td><\/tr><tr><td>D7213<\/td><td>Standard Test Method for Boiling Range Distribution of Petroleum Distillates in the Boiling Range from 100 to 615 \u00b0C by Gas Chromatography (C5\u2013C60)<\/td><td>MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.10 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70112\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70112<\/a> <em>or<\/em> MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.20 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70115\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70115<\/a> <em>or<\/em> MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.88 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70131\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70131<\/a><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1285\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1285<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1191\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1191<\/a><\/td><\/tr><tr><td>D6352<\/td><td>Standard Test Method for Boiling Range Distribution of Petroleum Distillates in Boiling Range from 174 to 700 \u00b0C by Gas Chromatography (C10\u2013C90)<\/td><td>MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.10 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70112\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70112<\/a> <em>or<\/em> MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.20 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70115\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70115<\/a><\/td><td>Polywax Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/36224\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 36224\u201336227<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1188\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1188<\/a><\/td><\/tr><tr><td>D7398<\/td><td>Standard Test Method for Boiling Range Distribution of Fatty Acid Methyl Esters (FAME) in the Boiling Range from 100 to<br>615 \u00b0C by Gas Chromatography<\/td><td>MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.88 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70131\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70131<\/a><\/td><td>Polywax Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/36224\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 36224\u201336227<\/a> &nbsp;<\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1285\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1285<\/a><\/td><\/tr><tr><td>D7500<\/td><td>Standard Test Method for Determination of Boiling Range Distribution of Distillates and Lubricating Base Oils in Boiling Range from 100 to 735 \u00b0C by Gas Chromatography (C7\u2013C110)<\/td><td>MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.10 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70112\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70112<\/a> <em>or<\/em> MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.20 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70115\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70115<\/a><\/td><td>&nbsp; Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/36224\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 36224\u201336227<\/a> &nbsp;<\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1164\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1164<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1165\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1165<\/a><\/td><\/tr><tr><td>D7169<\/td><td>Standard Test Method for Boiling Point Distribution of Samples with Residues Such as Crude Oils and Atmospheric and Vacuum Residues by High-Temperature Gas Chromatography<\/td><td>MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.10 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70112\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70112<\/a> <em>or<\/em> MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.20 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70115\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70115<\/a><\/td><td>Polywax Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/36224\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 36224\u201336227<\/a> &nbsp;<\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1308\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1308<\/a><\/td><\/tr><tr><td>D7096 <em>(replaces D3710)<\/em><\/td><td>Standard Test Method for Determination of the Boiling Range Distribution of Gasoline by Wide-Bore Capillary Gas Chromatography<\/td><td>MXT-1, Siltek-treated stainless steel<br>15 m x 0.53 mm x 5.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70177\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70177<\/a> <em>or<\/em> MXT-1, Siltek-treated stainless steel<br>30 m x 0.53 mm x 5.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70179\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70179<\/a><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a> <em>or<\/em> D3710-95 Calibration Mix<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/31223\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 31223<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1326\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1326<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1327\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1327<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1328\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1328<\/a><\/td><\/tr><tr><td colspan=\"5\"><strong>Detailed Hydrocarbon Analysis (DHA)<\/strong><\/td><\/tr><tr><td><strong>Method #<\/strong><\/td><td><strong>Method Title<\/strong><\/td><td><strong>Restek Column(s)<\/strong><\/td><td><strong>Restek Reference<br>Standard(s)<\/strong><\/td><td><strong>Chromatogram#<\/strong><\/td><\/tr><tr><td>D5134<\/td><td>Standard Test Method for Detailed Analysis of Petroleum Naphthas through&nbsp;n-Nonane by Capillary Gas Chromatography<\/td><td>Rtx-DHA-50<br>50 m x 0.20 mm x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10147\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10147<\/a><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1318\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1318<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1319\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1319<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1320\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1320<\/a><\/td><\/tr><tr><td>D6729<\/td><td>Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 100-Meter Capillary High-Resolution Gas Chromatography<\/td><td>Rtx-DHA-100<br>100 m x 0.25 mm x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10148\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10148<\/a><\/td><td>DHA Standards<br>&#8211;\u00a0<a href=\"https:\/\/www.restek.com\/p\/33034\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 33034<\/a><br>&#8211;\u00a0<a href=\"https:\/\/www.restek.com\/p\/30725\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 30725<\/a><br>&#8211; <a href=\"https:\/\/www.restek.com\/p\/30726\" target=\"_blank\" rel=\"noopener\">cat.# 30726<\/a><br>&#8211; <a href=\"https:\/\/www.restek.com\/p\/30727\" target=\"_blank\" rel=\"noopener\">cat.# 30727<\/a><br>&#8211; <a href=\"https:\/\/www.restek.com\/p\/30728\" target=\"_blank\" rel=\"noopener\">cat.# 30728<\/a><br>&#8211; <a href=\"https:\/\/www.restek.com\/p\/30730\" target=\"_blank\" rel=\"noopener\">cat.# 30730<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1322\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1322<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1323\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1323<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1324\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1324<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1325\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1325<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1330\" target=\"_blank\" rel=\"noopener\">GC_PC1330<\/a><\/td><\/tr><tr><td>D6730<\/td><td>Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 100\u2013Meter Capillary (with precolumn) High-Resolution Gas Chromatography<\/td><td>Rtx-DHA-100<br>100 m x 0.25 mm x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10148\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10148<\/a> <em>and<\/em> Rtx-5 DHA Tuning<br>5 m x 0.25 mm x 1.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10165\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10165<\/a><\/td><td>DHA Standards<br>&#8211;\u00a0<a href=\"https:\/\/www.restek.com\/p\/33034\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 33034<\/a><br>&#8211;\u00a0<a href=\"https:\/\/www.restek.com\/p\/30725\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 30725<\/a><br>&#8211; <a href=\"https:\/\/www.restek.com\/p\/30726\" target=\"_blank\" rel=\"noopener\">cat.# 30726<\/a><br>&#8211; <a href=\"https:\/\/www.restek.com\/p\/30727\" target=\"_blank\" rel=\"noopener\">cat.# 30727<\/a><br>&#8211; <a href=\"https:\/\/www.restek.com\/p\/30728\" target=\"_blank\" rel=\"noopener\">cat.# 30728<\/a><br>&#8211; <a href=\"https:\/\/www.restek.com\/p\/30730\" target=\"_blank\" rel=\"noopener\">cat.# 30730<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1284\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1284<\/a><\/td><\/tr><tr><td>D6733<\/td><td>Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 50-Meter Capillary High-Resolution Gas Chromatography<\/td><td>Rtx-DHA-50<br>50 m x 0.20 mm x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10147\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10147<\/a><\/td><td>DHA Standards<br>&#8211;\u00a0<a href=\"https:\/\/www.restek.com\/p\/33034\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 33034<\/a><br>&#8211;\u00a0<a href=\"https:\/\/www.restek.com\/p\/30725\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 30725<\/a><br>&#8211; <a href=\"https:\/\/www.restek.com\/p\/30726\" target=\"_blank\" rel=\"noopener\">cat.# 30726<\/a><br>&#8211; <a href=\"https:\/\/www.restek.com\/p\/30727\" target=\"_blank\" rel=\"noopener\">cat.# 30727<\/a><br>&#8211; <a href=\"https:\/\/www.restek.com\/p\/30728\" target=\"_blank\" rel=\"noopener\">cat.# 30728<\/a><br>&#8211; <a href=\"https:\/\/www.restek.com\/p\/30730\" target=\"_blank\" rel=\"noopener\">cat.# 30730<\/a><\/td><td>&nbsp;<\/td><\/tr><tr><td colspan=\"5\"><strong>Finished Gasoline<\/strong><\/td><\/tr><tr><td><strong>Method #<\/strong><\/td><td><strong>Method Title<\/strong><\/td><td><strong>Restek Column(s)<\/strong><\/td><td><strong>Restek Reference<br>Standard(s)<\/strong><\/td><td><strong>Chromatogram#<\/strong><\/td><\/tr><tr><td>D3606<\/td><td>Standard Test Method for Determination of Benzene and Toluene in Spark Ignition Fuels by Gas Chromatography<\/td><td>D3606 Packed GC Column Set, Sulfinert, General Configuration<br><em>&#8211; <a href=\"https:\/\/www.restek.com\/p\/83606-800\" target=\"_blank\" rel=\"noreferrer noopener\">cat.#83606-800<\/a><\/em><br><em><br>Specified in the D3606 method addendum\u2014includes:<\/em> <em>&#8211; Column 1: Backflush column<br>6&#8242; (1.8 m), 1\/8&#8243; OD, 2.0 mm ID<br><br>and<\/em> <em>&#8211; Column 2: proprietary packing<br>16&#8242; (4.9 m), 1\/8&#8243; OD, 2.0 mm ID<br><br><br><\/em>D3606 GC Capillary Column Set<em><br>&#8211; <a href=\"http:\/\/restek.com\/p\/118-D3606\" data-type=\"link\" data-id=\"restek.com\/p\/118-D3606\" target=\"_blank\" rel=\"noopener\">cat.#<\/a><a href=\"https:\/\/www.restek.com\/p\/118-D3606\" target=\"_blank\" rel=\"noreferrer noopener\"><\/a><a href=\"https:\/\/restek.com\/p\/118-D3606\" data-type=\"link\" data-id=\"https:\/\/restek.com\/p\/118-D3606\" target=\"_blank\" rel=\"noopener\">118-D3606<\/a><br><\/em> <em>&#8211; Column 1: Rxi-1ms Capillary Column,&nbsp;<br>30 m, 0.25 mm ID, 0.50 \u00b5m<br>(<a href=\"https:\/\/www.restek.com\/p\/13338\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 13338<\/a>)<br><br>and<br><br>&nbsp;&#8211; Column 2: Stabilwax GC Capillary Column, 60 m, 0.32 mm ID, 1.00 \u00b5m (<a href=\"https:\/\/www.restek.com\/p\/10657\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10657<\/a>)<\/em><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><a href=\"p\/30647\"><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC01121\" target=\"_blank\" rel=\"noreferrer noopener\">PC01121<\/a><\/td><\/tr><tr><td>D4815<\/td><td>Standard Test Method for Determination of MTBE, ETBE, TAME, DIPE, tertiary-Amyl Alcohol, and C1 to C4 Alcohols in Gasoline by Gas Chromatography (Oxygenates)<\/td><td>Micropacked with 20% TCEP on 80\/100 Chromosorb PAW<br>0.56 m x 0.75 mm ID x 1\/16&#8243; OD<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/19040\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 19040<\/a> <em>and<\/em> Rtx-1<br>30 m x 0.53 mm x 3.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10185\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10185<\/a><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC00194\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC00194<\/a><\/td><\/tr><tr><td>D5580<\/td><td>Standard Test Method for Determination of Benzene, Toluene, Ethylbenzene,&nbsp;<em>p\/m<\/em>-Xylene,&nbsp;o-Xylene, C9 and Heavier Aromatics, and Total Aromatics in Finished Gasoline by Gas Chromatography<\/td><td>Micropacked with 20% TCEP on 80\/100 Chromosorb PAW<br>0.56 m x 0.75 mm ID x 1\/16&#8243; OD<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/19040\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 19040<\/a> <em>and<\/em> Rtx-1<br>30 m x 0.53 mm x 5.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10179\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10179<\/a><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td>&nbsp;<\/td><\/tr><tr><td>D5501<\/td><td>Standard Test Method for Determination of Ethanol Content of Denatured Fuel Ethanol by Gas Chromatography<\/td><td>Rtx-DHA-150<br>150 m x 0.25 mm x 1.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10149\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10149<\/a> <em>or<\/em> Rtx-DHA-100<br>100 m x 0.25 mm x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10148\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10148<\/a><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1144\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1144<\/a><\/td><\/tr><tr><td>D8071<\/td><td>Standard Test Method for Determination of Hydrocarbon Group Types and Select Hydrocarbon and Oxygenate Compounds in Automotive Spark-Ignition Engine Fuel Using Gas Chromatography with Vacuum Ultraviolet Absorption Spectroscopy Detection (GC-VUV)<\/td><td>Rxi-1ms<br>30 m x 0.25 mm x 0.25 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/13323\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 13323<\/a> &nbsp;<\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1358\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1358<\/a><\/td><\/tr><tr><td colspan=\"5\"><strong>Biodiesel<\/strong><\/td><\/tr><tr><td><strong>Method #<\/strong><\/td><td><strong>Method Title<\/strong><\/td><td><strong>Restek Column(s)<\/strong><\/td><td><strong>Restek Reference<br>Standard(s)<\/strong><\/td><td><strong>Chromatogram#<\/strong><\/td><\/tr><tr><td>D6584<\/td><td>Test Method for Determination of Free and Total Glycerin in B-100 Biodiesel Methyl Esters by Gas Chromatography<\/td><td>MXT-Biodiesel TG, Siltek-treated stainless steel<br>14 m x 0.53 mm x 0.16 \u00b5m<br>with 2 m Integra-Gap<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70289\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70289<\/a> <em>or<\/em> MXT-Biodiesel TG, Siltek-treated stainless steel<br>15 m x 0.32 mm x 0.10 \u00b5m<br>with 2 m x 0.53 mm retention gap<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70291\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70291<\/a> <em>or<\/em> Rtx-Biodiesel TG<br>15 m x 0.32 mm x 0.10 \u00b5m<br>with 2 m x 0.53 mm retention gap<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10293\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10293<\/a><\/td><td>Biodiesel Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/31880\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 31880<\/a><br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/33020\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 33020\u201333026<\/a><br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/33032\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 33032\u201333033<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1293\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1293<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC00969\" target=\"_blank\" rel=\"noopener\">GC_PC00969<\/a><\/td><\/tr><tr><td colspan=\"5\"><strong>Jet Fuel<\/strong><\/td><\/tr><tr><td><strong>Method #<\/strong><\/td><td><strong>Method Title<\/strong><\/td><td><strong>Restek Column(s)<\/strong><\/td><td><strong>Restek Reference<br>Standard(s)<\/strong><\/td><td><strong>Chromatogram#<\/strong><\/td><\/tr><tr><td>D8267<\/td><td>Standard Test Method for Determination of Saturated Hydrocarbon, Aromatic, and Diaromatic Content of Aviation Turbine Fuels Using Gas Chromatography with Vacuum Ultraviolet Absorption Spectroscopy Detection (GC-VUV)<\/td><td>Rxi-1ms<br>30 m x 0.25 mm x 0.25 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/13323\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 13323<\/a> &nbsp;<\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1359\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1359<\/a><\/td><\/tr><tr><td colspan=\"5\"><strong>Natural Gas<\/strong><\/td><\/tr><tr><td><strong>Method #<\/strong><\/td><td><strong>Method Title<\/strong><\/td><td><strong>Restek Column(s)<\/strong><\/td><td><strong>Restek Reference<br>Standard(s)<\/strong><\/td><td><strong>Chromatogram#<\/strong><\/td><\/tr><tr><td>D1945<\/td><td>Standard Test Method for Analysis of Natural Gas by Gas Chromatography<\/td><td>MXT-Msieve 5A, Siltek-treated stainless steel<br>30 m x 0.53 mm x 50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/79723-273\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 79723-273<\/a> <em>and<\/em> MXT-Q-BOND, Siltek-treated stainless steel<br>30 m x 0.53 mm x 20 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/79716-273\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 79716-273<\/a><\/td><td>Natural Gas Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/34438\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 34438\u201334440<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1182\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1182<\/a><\/td><\/tr><tr><td colspan=\"5\"><strong>Refinery Gas<\/strong><\/td><\/tr><tr><td><strong>Method #<\/strong><\/td><td><strong>Method Title<\/strong><\/td><td><strong>Restek Column(s)<\/strong><\/td><td><strong>Restek Reference<br>Standard(s)<\/strong><\/td><td><strong>Chromatogram#<\/strong><\/td><\/tr><tr><td>D2163<\/td><td>Standard Test Method for Determination of Hydrocarbons in Liquefied Petroleum (LP) Gases and Propane\/Propene Mixtures by Gas Chromatography<\/td><td>Rt-Alumina BOND\/Na<sub>2<\/sub>SO<sub>4<\/sub><br>50 m x 0.53 mm x 10 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/19756\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 19756<\/a><\/td><td>Refinery Gas Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/34441\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 34441\u201334443<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1309\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1309<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1310\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1310<\/a><\/td><\/tr><tr><td>UOP 539<\/td><td>Standard Practice for Analysis of Reformed Gas by Gas Chromatography<\/td><td>2abc Refinery Gas Packed Column Set<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/88000-875\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 88000-875<\/a> <em>or<\/em> MXT-Msieve 5A, Siltek-treated stainless steel<br>30 m x 0.53 mm x 50 \u00b5m<br>&#8211;&nbsp;cat.# <a href=\"https:\/\/www.restek.com\/p\/79723-273\" target=\"_blank\" rel=\"noopener\">79723-273<\/a> <em>and<\/em> MXT-Q-BOND, Siltek-treated stainless steel<br>30 m x 0.53 mm x 20 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/79716\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 79716<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1182\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1182<\/a><\/td><\/tr><tr><td colspan=\"5\"><strong>Impurities<\/strong><\/td><\/tr><tr><td><strong>Method #<\/strong><\/td><td><strong>Method Title<\/strong><\/td><td><strong>Restek Column(s)<\/strong><\/td><td><strong>Restek Reference<br>Standard(s)<\/strong><\/td><td><strong>Chromatogram#<\/strong><\/td><\/tr><tr><td>D2593<\/td><td>Standard Test Method for Butadiene Purity and Hydrocarbon Impurities by Gas Chromatography<\/td><td>Rt-Alumina BOND\/MAPD<br>50 m x 0.53 mm x 10 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/19778\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 19778<\/a><\/td><td>Refinery Gas Standard #5<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/34443\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 34443<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1202\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1202<\/a><\/td><\/tr><tr><td>D2712<\/td><td>Standard Test Method for Hydrocarbon Traces in Propylene Concentrates by Gas Chromatography<\/td><td>Rt-Alumina BOND\/KCl<br>50 m x 0.53 mm x 10 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/19760\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 19760<\/a><\/td><td>Refinery Gas Standard #5<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/34443\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 34443<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC01142\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC01142<\/a><\/td><\/tr><tr><td>D6159<\/td><td>Standard Test Method for Determination of Hydrocarbon Impurities in Ethylene by Gas Chromatography<\/td><td>Rt-Alumina BOND\/KCl<br>50 m x 0.53 mm x 10 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/19760\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 19760<\/a> <em>and<\/em> Rtx-1<br>30 m x 0.53 mm x 5.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10179\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10179<\/a><\/td><td>Refinery Gas Standard #5<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/34443\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 34443<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC01110\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC01110<\/a><\/td><\/tr><tr><td>D5441<\/td><td>Standard Test Method for Analysis of Methyl&nbsp;<em>Tert<\/em>-Butyl Ether (MTBE) by Gas Chromatography<\/td><td>Rtx-DHA-100<br>100 m x 0.25 mm x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10148\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10148<\/a> <em>or<\/em> Rtx-DHA-50<br>50 m x 0.20 mm x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10147\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10147<\/a> <em>or<\/em> Rtx-DHA-150<br>150 m x 0.25 mm x 1.0 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10149\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10149<\/a><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1268\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1268<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1270\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1270<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1269\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1269<\/a><\/td><\/tr><tr><td>D8311<\/td><td>Test Method for Impurities in Monoethylene Glycol by Gas Chromatography with Normalization<\/td><td>Rxi-624Sil MS<br>30 m x 0.32 mm ID x 1.80 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/13870\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 13870<\/a><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><\/td><\/tr><tr><td>E2409<\/td><td>Test Method for Glycol Impurities in Mono-, Di-, Tri- and Tetraethylene Glycol (Gas Chromatographic Method)<\/td><td>Rtx-Wax<br>15 m x 0.53 mm ID x 1.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/12452\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 12452<\/a><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><\/td><\/tr><tr><td colspan=\"5\"><strong>Sulfur<\/strong><\/td><\/tr><tr><td><strong>Method #<\/strong><\/td><td><strong>Method Title<\/strong><\/td><td><strong>Restek Column(s)<\/strong><\/td><td><strong>Restek Reference<br>Standard(s)<\/strong><\/td><td><strong>Chromatogram#<\/strong><\/td><\/tr><tr><td>D6228<\/td><td>Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Flame Photometric Detection<\/td><td>Rtx-1<br>60 m x 0.53 mm x 7.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10193\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10193<\/a> <em>or<\/em> MXT-1, Siltek-treated stainless steel<br>60 m x 0.53 mm x 7.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70193\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70193<\/a> <em>or<\/em> Rtx-1<br>60 m x 0.32 mm x 5.0 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10180\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10180<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1223\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1223<\/a><\/td><\/tr><tr><td>D5623<\/td><td>Standard Test Method for Sulfur Compounds in Light Petroleum Liquids by Gas Chromatography and Sulfur Selective Detection<\/td><td>Rtx-1<br>30 m x 0.32 mm x 4.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10198\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10198<\/a><\/td><td>Request today<br>(<a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noopener\">gas<\/a>,&nbsp;<a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">liquid<\/a>)<\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1271\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1271<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC00198\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC00198<\/a><\/td><\/tr><tr><td colspan=\"5\"><strong>Industrial Chemicals<\/strong><\/td><\/tr><tr><td><strong>Method #<\/strong><\/td><td><strong>Method Title<\/strong><\/td><td><strong>Restek Column(s)<\/strong><\/td><td><strong>Restek Reference<br>Standard(s)<\/strong><\/td><td><strong>Chromatogram#<\/strong><\/td><\/tr><tr><td>D5917<\/td><td>Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and External Calibration<\/td><td>Stabilwax<br>60 m x 0.32 mm x 0.25 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10627\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10627<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1355\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1355<\/a><br><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1352\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1352<\/a><br><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1353\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1353<\/a><br><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1354\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1354<\/a><\/td><\/tr><tr><td>D7266<\/td><td>Standard Test Method for Analysis of Cyclohexane by Gas Chromatography (External Standard)<\/td><td>Rtx-DHA-100<br>100 m x 0.25 mm x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10148\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10148<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1356\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1356<\/a><\/td><\/tr><tr><td>D7504<\/td><td>Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and Effective Carbon Number<\/td><td>Stabilwax<br>60 m x 0.32 mm x 0.25 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10627\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10627<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1352\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1352<\/a><br><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1353\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1353<\/a><br><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1354\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1354<\/a><br><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1355\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1355<\/a><\/td><\/tr><tr><td>D7871<\/td><td>Standard Test Method for Analysis of Cyclohexane by Gas Chromatography (Effective Carbon Number)<\/td><td>Rtx-DHA-100<br>100 m x 0.25 mm x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10148\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10148<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1356\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1356<\/a><\/td><\/tr><tr><td>D7011<\/td><td>Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography and Sulfur Selective Detection<\/td><td>Rtx-WAX<br>30 m x 0.32 mm x 1.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/12454\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 12454<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1357\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1357<\/a><\/td><\/tr><tr><td>D6144<\/td><td>Standard Test Method for Analysis of AMS (a-Methylstyrene) by Capillary Gas Chromatography<\/td><td>Rtx-1<br>60 m x 0.32 mm x 1.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10157\" target=\"_blank\" rel=\"noopener\">cat.# 10157<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1351\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1351<\/a><\/td><\/tr><tr><td>D7057<\/td><td>Standard Test Method for Analysis of Isopropylbenzene (Cumene) by Gas Chromatography (External Standard)<\/td><td>Rtx-1<br>60 m x 0.32 mm x 1.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10157\" target=\"_blank\" rel=\"noopener\">cat.# 10157<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1350\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1350<\/a><\/td><\/tr><tr><td>D5310<\/td><td>Standard Test Method for Tar Acid Composition by Capillary Gas Chromatography<\/td><td>Rxi 5MS<br>30 m x 0.53 mm x 1.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/13423\" target=\"_blank\" rel=\"noopener\">cat.# 13423<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1371\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1371<\/a><\/td><\/tr><tr><td>D3329<\/td><td>Standard Test Method for Purity of Methyl Isobutyl Ketone by Gas Chromatography<\/td><td>Stabilwax<br>30 m x 0.25 mm x 1.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10655\" target=\"_blank\" rel=\"noreferrer noopener\">cat. #10655<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1373\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1373<\/a><\/td><\/tr><tr><td>D7090<\/td><td>Standard Test Method for Purity of Isophorone by Capillary Gas Chromatography<\/td><td>Rtx &#8211; WAX<br>30 m x 0.32 mm x 0.5 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/12439\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 12439<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1369\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1369<\/a><\/td><\/tr><tr><td>D3893<\/td><td>Standard Test Method for Purity of Methyl Amyl Ketone and Methyl Isoamyl Ketone by Gas Chromatography<\/td><td>Stabilwax<br>30 m x 0.53 mm x 1.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10655\" target=\"_blank\" rel=\"noreferrer noopener\">cat. #10655<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td>&nbsp;<\/td><\/tr><tr><td>D6142<\/td><td>Test Method Analysis of Phenol by Capillary Gas Chromatography<\/td><td>Stabilwax-DA<br>50 m x 0.32 mm ID x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/11042-105\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 11042-105<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><\/td><\/tr><tr><td>D8266<\/td><td>Test Method for Analysis of Bisphenol A (4,4&#8242;-Isopropylidenediphenol)<\/td><td>Ultra C18<br>5 \u00b5m x 250 x 4.6 mm<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/9174575\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 9174575<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Restek is your ideal partner for integrated petrochemical solutions, and our ASTM method product guide will help you quickly pick the right GC columns and reference standards for SimDist, DHA, finished gasoline, and other common petroleum analyses.<\/p>\n","protected":false},"author":11,"featured_media":7537,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[462],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[567],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-39927","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-fr","resource-type-selection-guides"],"acf":[],"taxonomy_info":{"category":[{"value":462,"label":"Articles"}],"resource-type":[{"value":567,"label":"Selection Guides"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-PCAR2082-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/it\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":462,"name":"Articles","slug":"articles-fr","term_group":0,"term_taxonomy_id":462,"taxonomy":"category","description":"","parent":0,"count":507,"filter":"raw","cat_ID":462,"category_count":507,"category_description":"","cat_name":"Articles","category_nicename":"articles-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/39927","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=39927"}],"version-history":[{"count":26,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/39927\/revisions"}],"predecessor-version":[{"id":102827,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/39927\/revisions\/102827"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media\/7537"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=39927"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=39927"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=39927"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=39927"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=39927"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=39927"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=39927"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=39927"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=39927"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}