{"id":42430,"date":"2018-04-24T04:00:00","date_gmt":"2018-04-24T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/scegliere-il-giusto-raccordo-exp\/"},"modified":"2025-12-20T18:34:22","modified_gmt":"2025-12-20T18:34:22","slug":"scegliere-il-giusto-raccordo-exp","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/video\/gnav3565-it\/scegliere-il-giusto-raccordo-exp","title":{"rendered":"Scegliere il giusto raccordo EXP"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Choosing the Right EXP Fitting\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/Q_8dBlymTqk?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*Sottotitoli disponibili in italiano*<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Descrizione<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Esistono diversi tipi di raccordi per effettuare il collegamento con la cromatografia liquida. Quando si utilizzano tubi in acciaio inox suggeriamo i raccordi EXP. Sono riutilizzabili e disponibili in diverse configurazioni, cos\u00ec da ottenere esattamente il tipo di collegamento desiderato in tutto il tuo sistema. Ti mostreremo come scegliere sempre quello giusto.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Altre Risorse<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/GNSS1774.pdf\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/wp-content\/uploads\/GNSS1774.pdf\">EXP and EXP2 Fittings<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/GNSS1774.pdf\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/wp-content\/uploads\/GNSS1774.pdf\">EXP Fitting Instruction Sheet<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/GNSS1774.pdf\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/wp-content\/uploads\/GNSS1774.pdf\">EXP2 Fitting Instruction Sheet<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Strumenti e ricambi raccomandati da Restek<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/it\/search\/tubi-e-raccordi-lc\/_\/N-3385188652+2707067338?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noopener\">EXP Reusable Fittings for HPLC &amp; UHPLC<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Trascrizione<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Buongiorno a tutti e benvenuti a un altro dei nostri video \u201cRestek Tip\u201d. Oggi vi mostreremo come scegliere il giusto raccordo EXP. Il sistema EXP \u00e8 progettato per tubi in acciaio e comprende diverse tipologie di dadi da coniugare alle ferrule in PEEK e titanio. La ferrula deve essere inserita in modo che il PEEK si infili nell\u2019entrata della colonna e crei la tenuta, mentre la parte di metallo sia rivolta verso il dado; in questo modo, quando la ferrula viene stretta, si fissa in maniera sicura ma non permanente al tubo. Pu\u00f2 quindi essere riutilizzata diverse volte senza compromettere la tenuta. Si possono scegliere varie tipologie di dadi. Innanzitutto quello classico con testa esagonale e tre diverse lunghezze di filettatura, che pu\u00f2 essere utilizzato per tutti i tipi di collegamenti dall\u2019uscita della pompa sul tubo che va al mixer o per il collegamento al mixer stesso. Abbiamo poi il raccordo da serrare a mano, con la testa leggermente pi\u00f9 grande per una maggiore presa durante il serraggio manuale. Questa tipologia pu\u00f2 essere usata quando si ha un po\u2019 pi\u00f9 di spazio, per esempio per collegare la pompa al mixer. C\u2019\u00e8 poi la tipologia EXP2 a testa stretta, che viene fornita completa di chiave per poter montare il raccordo quando c\u2019\u00e8 poco spazio di manovra, come nel caso di una valvola multiporta. Qualsiasi raccordo sceglierete, otterrete una connessione affidabile per il vostro tubo LC. Grazie per aver guardato questo video. Arrivederci al prossimo \u201cRestek tip\u201d.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Sperimentare quanto possono essere validi i raccordi per cromatografia liquida! Questo Restek Tip fornisce la conoscenza dei raccordi EXP e delle loro numerose opzioni per una selezione rapida e collegamenti di qualit\u00e0.<\/p>\n","protected":false},"author":11,"featured_media":41014,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[773],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2517,2540],"resource-technique":[2334],"ppma_author":[414],"class_list":["post-42430","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-video","product-library-prodotti-per-cromatografia-liquida","product-library-tubi-raccordi-lc","resource-technique-cromatografia-liquida-lc"],"acf":[],"taxonomy_info":{"category":[{"value":773,"label":"Video"}],"product-library":[{"value":2517,"label":"Prodotti per Cromatografia Liquida"},{"value":2540,"label":"Tubi e Raccordi LC"}],"resource-technique":[{"value":2334,"label":"Cromatografia Liquida (LC)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3565-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/it\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":773,"name":"Video","slug":"video","term_group":0,"term_taxonomy_id":773,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":773,"category_count":138,"category_description":"","cat_name":"Video","category_nicename":"video","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/42430","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=42430"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/42430\/revisions"}],"predecessor-version":[{"id":76191,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/42430\/revisions\/76191"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media\/41014"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=42430"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=42430"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=42430"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=42430"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=42430"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=42430"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=42430"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=42430"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=42430"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}