{"id":42470,"date":"2020-03-24T04:00:00","date_gmt":"2020-03-24T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/come-stoccare-gli-standard-di-riferimento\/"},"modified":"2026-10-02T14:15:44","modified_gmt":"2026-10-02T14:15:44","slug":"come-stoccare-gli-standard-di-riferimento","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/video\/gnav3610-it\/come-stoccare-gli-standard-di-riferimento","title":{"rendered":"Come stoccare gli standard di riferimento"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"How to Store Reference Standards\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/RW1f6WGItis?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*Sottotitoli disponibili in italiano*<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Descrizione&nbsp;<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le variazioni nella concentrazione degli analiti possono pregiudicare le analisi, ostacolare il flusso di lavoro del laboratorio e provocare perdite di tempo e denaro. Uno stoccaggio corretto degli standard di riferimento garantisce la stabilit\u00e0 ottimale degli analiti, consentendoti di concentrarti sulle analisi.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In questo video Restek Tip ti spiegheremo come stoccare in modo sicuro i tuoi standard di riferimento a diversi range di temperatura e dove puoi trovare informazioni dettagliate sullo stoccaggio dei tuoi standard specifici.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Altre Risorse<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Handling Your Analytical Reference Standards<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Strumenti e ricambi raccomandati da Restek<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1102?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noopener\">Restek&#8217;s Reference Standards<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/global\/it\/custom-reference-standard-request-form\" target=\"_blank\" rel=\"noopener\">Restek&#8217;s Search, Select, and Custom Request Reference Standards<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Trascrizione<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Lo stoccaggio corretto degli standard di riferimento \u00e8 essenziale per garantire una stabilit\u00e0 ottimale degli analiti nello standard.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nel video Restek Tip di oggi parleremo dello stoccaggio degli standard di riferimento. Spiegheremo perch\u00e9 \u00e8 importante stoccare in modo sicuro gli standard di riferimento e come stoccarli.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Innanzitutto devi sempre seguire le istruzioni riportate sul certificato del tuo standard di riferimento. Puoi trovare indicazioni anche sull\u2019etichetta del contenitore di trasporto dell\u2019ampolla e sull\u2019etichetta dell\u2019ampolla stessa, tra cui i requisiti specifici per lo stoccaggio e la sonicazione.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se non \u00e8 indicato sul certificato, pu\u00f2 essere prudente stoccare gli standard di riferimento a una temperatura inferiore a quella raccomandata.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In tal caso lascia che l\u2019ampolla raggiunga la temperatura ambiente, poi capovolgila pi\u00f9 volte prima di aprirla. In questo modo potrai essere certo che gli analiti non si trovino nello spazio di testa dell\u2019ampolla. Se noti la presenza di materiale non dissolto, pu\u00f2 essere necessario effettuare la sonicazione.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">E se lo stoccaggio avviene a temperature pi\u00f9 elevate? In genere, una breve esposizione (per un periodo inferiore a sette giorni) a una temperatura di stoccaggio pi\u00f9 elevata non dovrebbe influenzare negativamente la stabilit\u00e0 a lungo termine dello standard.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ricorda che, una volta aperto, l\u2019integrit\u00e0 dello standard dipende dalle condizioni di manipolazione e stoccaggio e non pu\u00f2 pi\u00f9 essere garantita.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Per eventuali domande puoi contattarci su restek.com o commentare sotto. Metti Mi piace e iscriviti al nostro canale, e grazie per aver guardato questo Restek Tip.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Come conservate gli standard di riferimento? Guarda il nostro ultimo Restek Tip per capire perch\u00e9 e come conservare in sicurezza i tuoi standard.<\/p>\n","protected":false},"author":11,"featured_media":41128,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[773,773],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2543,2518,2543],"resource-technique":[],"ppma_author":[414],"class_list":["post-42470","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-video","product-library-standard-di-riferimento-liquidi","product-library-standard-di-riferimento"],"acf":[],"taxonomy_info":{"category":[{"value":773,"label":"Video"},{"value":773,"label":"Video"}],"product-library":[{"value":2543,"label":"Standard di Riferimento Liquidi"},{"value":2518,"label":"Standard di Riferimento"},{"value":2543,"label":"Standard di Riferimento Liquidi"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3610-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/it\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":773,"name":"Video","slug":"video","term_group":0,"term_taxonomy_id":773,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":773,"category_count":138,"category_description":"","cat_name":"Video","category_nicename":"video","category_parent":0},{"term_id":773,"name":"Video","slug":"video","term_group":0,"term_taxonomy_id":773,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":773,"category_count":138,"category_description":"","cat_name":"Video","category_nicename":"video","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/42470","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=42470"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/42470\/revisions"}],"predecessor-version":[{"id":76097,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/42470\/revisions\/76097"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media\/41128"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=42470"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=42470"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=42470"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=42470"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=42470"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=42470"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=42470"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=42470"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=42470"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}