{"id":42530,"date":"2020-03-03T04:00:00","date_gmt":"2020-03-03T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/sonicare-gli-standard-di-riferimento\/"},"modified":"2025-12-20T16:17:46","modified_gmt":"2025-12-20T16:17:46","slug":"sonicare-gli-standard-di-riferimento","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/video\/gnav3657-it\/sonicare-gli-standard-di-riferimento","title":{"rendered":"Sonicare gli standard di riferimento"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Sonicating Your Reference Standard\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/BZJhCXRkOKc?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*Sottotitoli disponibili in italiano*<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Descrizione<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Lo sapevi che, a seconda di come conservi gli standard di riferimento, \u00e8 possibile che alcuni analiti precipitino?&nbsp;Questo influir\u00e0 sulla concentrazione degli analiti, compromettendo le tue analisi.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In questo video \u201cRestek Tip\u201d, ti mostreremo come la sonicazione possa contribuire alla ridissoluzione degli analiti. Spiegheremo come sonicare le ampolle e condivideremo anche alcuni suggerimenti sulla sicurezza.&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Altre Risorse<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/it\/chromablography\/handling-your-analytical-reference-standards\" target=\"_blank\" rel=\"noopener\">Handling Your Analytical Reference Standards<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Strumenti e ricambi raccomandati da Restek<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/it\/custom-reference-standard-request-form\" target=\"_blank\" rel=\"noopener\">Restek&#8217;s Search, Select, and Custom Request Reference Standards<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/global\/it\/c\/1102?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noopener\">Restek&#8217;s Reference Standards<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Trascrizione<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A seconda delle condizioni di stoccaggio degli standard di riferimento, potrebbe essere necessario sonicarli prima dell&#8217;uso.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nel \u201cRestek Tip\u201d di oggi mostreremo perch\u00e9 potrebbe essere necessario sonicare i tuoi standard di riferimento, e come farlo.&nbsp;Cominciamo con il perch\u00e9. Se lo standard \u00e8 conservato a bassa temperatura, \u00e8 possibile che alcuni analiti precipitino. Questo influir\u00e0 sulla concentrazione degli analiti, compromettendo le tue analisi. In questo caso, la sonicazione sar\u00e0 necessaria per garantire che tutti gli analiti siano in soluzione prima di trasferire e utilizzare lo standard.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Prima di procedere alla sonicazione devi verificare l\u2019assenza di incrostazioni minerali nel sonicatore. Successivamente devi accertare la presenza di un quantitativo sufficiente di acqua deionizzata nel bagno (il livello dell&#8217;acqua pu\u00f2 dipendere dalle procedure e dagli strumenti del laboratorio). Infine metti l&#8217;ampolla nel sonicatore e imposta il funzionamento per 10-15 minuti.&nbsp;Il processo di sonicazione genera calore, che pu\u00f2 aumentare la pressione all\u2019interno dell\u2019ampolla. Si consiglia di far raffreddare lo standard di riferimento a temperatura ambiente e aprire l&#8217;ampolla sotto una cappa per evitare schizzi.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Per eventuali domande puoi contattarci su&nbsp;restek.com o commentare qui di seguito. E non dimenticare di mettere un like e iscriverti. Grazie per aver guardato questo \u201cRestek tip\u201d.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Conservi gli standard di riferimento a basse temperature? Guarda il nostro ultimo Video Restek Tip per capire perch\u00e9 e come sonicare i tuoi standard.<\/p>\n","protected":false},"author":11,"featured_media":41278,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[773],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2518,2543],"resource-technique":[],"ppma_author":[414],"class_list":["post-42530","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-video","product-library-standard-di-riferimento","product-library-standard-di-riferimento-liquidi"],"acf":[],"taxonomy_info":{"category":[{"value":773,"label":"Video"}],"product-library":[{"value":2518,"label":"Standard di Riferimento"},{"value":2543,"label":"Standard di Riferimento Liquidi"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3657-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/it\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":773,"name":"Video","slug":"video","term_group":0,"term_taxonomy_id":773,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":773,"category_count":138,"category_description":"","cat_name":"Video","category_nicename":"video","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/42530","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=42530"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/42530\/revisions"}],"predecessor-version":[{"id":78774,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/42530\/revisions\/78774"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media\/41278"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=42530"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=42530"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=42530"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=42530"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=42530"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=42530"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=42530"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=42530"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=42530"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}