{"id":42582,"date":"2019-10-29T04:00:00","date_gmt":"2019-10-29T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/scelta-del-tampone-per-metodi-hilic\/"},"modified":"2025-12-20T16:07:00","modified_gmt":"2025-12-20T16:07:00","slug":"scelta-del-tampone-per-metodi-hilic","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/video\/gnav4887-it\/scelta-del-tampone-per-metodi-hilic","title":{"rendered":"Scelta del Tampone per Metodi HILIC"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Buffer Choices for HILIC\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/O0WWmQmhzpk?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Descrizione&nbsp;<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La cromatografia liquida a interazione idrofilica, o HILIC, \u00e8 un\u2019efficace tecnica della cromatografia liquida (LC) che utilizza fasi stazionarie polari e condizioni iniziali della fase mobile ad elevata percentuale di solvente organico per la separazione degli analiti polari. I tamponi sono molto importanti per nei metodi HILIC perch\u00e9 lo stato di ionizzazione, sia degli analiti che della fase stazionaria, avr\u00e0 un impatto sulla separazione. Qui vedremo quali sono gli step per ottimizzare le concentrazioni del tampone.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Altre Risorse<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/gnar2716\/how-to-avoid-common-problems-with-hilic-methods\/\" data-type=\"post\" data-id=\"43644\">How to Avoid Common Problems with HILIC Methods<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/gnss2687\/raptor-hilic-si-simplify-the-switch-to-hilic\/\" data-type=\"post\" data-id=\"43822\">Simplify the Switch to HILIC with Raptor HILIC-Si Columns<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Strumenti e ricambi raccomandati da Restek<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/it\/search\/hilic-si\/_\/N-1673632971?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noopener\">Raptor HILIC-Si Columns<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Trascrizione<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ora che state iniziando lo sviluppo del metodo LC HILIC, dovete prendere una decisione sulle fasi mobili.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Una buona performance LC HILIC \u00e8 legata allo stato di ionizzazione sia della fase stazionaria che degli analiti, che dipendono dal pH delle fasi mobili.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Per iniziare velocemente, suggeriamo la preparazione di almeno tre fasi mobili acquose con diversi pH.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La prima \u00e8 10 mM di formato di ammonio portata a pH 3 con soluzione di acido formico.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La seconda \u00e8 10 mM di acetato di ammonio portata a pH 5 con soluzione di acido acetico, mentre la terza \u00e8 10 mM di acetato di ammonio portata a pH 6,8 con soluzione di acido acetico.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Eseguendo un\u2019eluizione isocratica o a gradiente partendo con il 90% o 95% di acetonitrile, dovreste essere in grado di individuare la soluzione pH pi\u00f9 adatta semplicemente osservando le forme dei picchi degli analiti.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Una volta determinato il pH della fase mobile, potete ottimizzare il metodo aggiustando la concentrazione del tampone e il programma di eluizione.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Noterete che a volte, con una maggiore concentrazione del tampone, si ottengono migliori forme dei picchi, ma fate attenzione al fatto che i sali del tampone possono precipitare una volta miscelati a elevate percentuali di solventi organici.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Infine, per una eluizione a gradiente, \u00e8 buona norma tamponare allo stesso modo le fasi mobili acquose e organiche per mantenere una forza ionica costante durante la corsa.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se riuscite a eseguire con cura la selezione del pH e la concentrazione del tampone delle fasi mobili, inizierete con il piede giusto.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se vi \u00e8 piaciuto questo video, mettete un like, condividete e iscrivetevi al canale.&nbsp;<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>In questo Tip parleremo dell&#8217;importanza dei tamponi per le separazioni HILIC.<\/p>\n","protected":false},"author":11,"featured_media":41434,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[773],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2538,2517],"resource-technique":[2334,2356],"ppma_author":[414],"class_list":["post-42582","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-video","product-library-gestione-della-fase-mobile","product-library-prodotti-per-cromatografia-liquida","resource-technique-cromatografia-liquida-lc","resource-technique-hilic-it"],"acf":[],"taxonomy_info":{"category":[{"value":773,"label":"Video"}],"product-library":[{"value":2538,"label":"Gestione della Fase Mobile"},{"value":2517,"label":"Prodotti per Cromatografia Liquida"}],"resource-technique":[{"value":2334,"label":"Cromatografia Liquida (LC)"},{"value":2356,"label":"HILIC"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV4887-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/it\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":773,"name":"Video","slug":"video","term_group":0,"term_taxonomy_id":773,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":773,"category_count":138,"category_description":"","cat_name":"Video","category_nicename":"video","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/42582","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=42582"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/42582\/revisions"}],"predecessor-version":[{"id":76112,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/42582\/revisions\/76112"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media\/41434"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=42582"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=42582"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=42582"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=42582"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=42582"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=42582"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=42582"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=42582"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=42582"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}