{"id":42602,"date":"2018-01-03T05:00:00","date_gmt":"2018-01-03T05:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/tagliare-una-colonna-capillare-gc-in-silice-fusa\/"},"modified":"2025-12-20T16:21:37","modified_gmt":"2025-12-20T16:21:37","slug":"tagliare-una-colonna-capillare-gc-in-silice-fusa","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/video\/gnav4900-it\/tagliare-una-colonna-capillare-gc-in-silice-fusa","title":{"rendered":"Tagliare una colonna capillare GC in silice fusa"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Cutting a GC Fused Silica Capillary Column\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/5bzgXiP-FHE?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Sottotitoli disponibili in italiano<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Descrizione<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Quando si esegue la gascromatografia \u00e8 importante ottenere un buon taglio squadrato per la colonna capillare GC in silice fusa, e un tagliacolonne in ceramica \u00e8 lo strumento giusto per questa operazione. Un buon taglio \u00e8 fondamentale per garantire una corretta installazione della colonna e connessioni senza perdite. &nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Altre Risorse<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/gnot1098\/restek-capillary-column-installation-guide-section-i-brief-installation-procedure\/\" data-type=\"post\" data-id=\"37925\">Restek Capillary Column Installation Guide<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Strumenti e ricambi raccomandati da Restek&nbsp;<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/it\/p\/20116\" target=\"_blank\" rel=\"noopener\">Ceramic Scoring Wafer<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Trascrizione<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Buongiorno a tutti e benvenuti a un altro dei nostri \u201cRestek tip\u201d. In questo video taglieremo una colonna capillare GC in silice fusa, operazione per la quale sar\u00e0 necessario un solo strumento: un tagliacolonne in ceramica. Il primo passo sar\u00e0 quello di verificare i diversi lati del tagliacolonne e identificare il lato liscio.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c8 sufficiente passare il dito sul bordo del tagliacolonne per distinguere i lati lisci da quelli seghettati. Per tagliare la nostra colonna utilizzeremo il bordo liscio. Per fare questo, prenderemo semplicemente la colonna fra le dita e faremo scorrere il tagliacolonne in ceramica perpendicolarmente alla lunghezza della colonna stessa.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Useremo il bordo liscio per fare una piccola incisione sullo strato di poliammide esterno alla colonna. Poi, andr\u00e0 semplicemente staccato. \u00c8 tutto.&nbsp;Possiamo verificare il taglio della colonna se abbiamo a disposizione una lente di ingrandimento con la quale ispezionare il taglio per verificarne i bordi correttamente squadrati. O, se i vostri occhi funzionano meglio dei miei, vi sar\u00e0 sufficiente appoggiare la colonna sul retro del tagliacolonne.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">C\u2019\u00e8 infatti solitamente abbastanza contrasto per giudicare se il taglio \u00e8 avvenuto correttamente. Questo \u00e8 tutto quello che serve per tagliare una colonna capillare GC in silice fusa. Grazie a tutti per aver seguito il nostro &#8220;Restek tip&#8221;.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Quando si esegue la gascromatografia \u00e8 importante ottenere un buon taglio squadrato per la colonna capillare GC in silice fusa, e un taglia colonne in ceramica \u00e8 lo strumento giusto per questa operazione. Un buon taglio \u00e8 fondamentale per garantire una corretta installazione della colonna e connessioni senza perdite.<\/p>\n","protected":false},"author":11,"featured_media":41488,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[773],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2528,2516],"resource-technique":[2332],"ppma_author":[414],"class_list":["post-42602","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-video","product-library-colonne-gc","product-library-prodotti-per-gascromatografia","resource-technique-gascromatografia-gc"],"acf":[],"taxonomy_info":{"category":[{"value":773,"label":"Video"}],"product-library":[{"value":2528,"label":"Colonne GC"},{"value":2516,"label":"Prodotti per Gascromatografia"}],"resource-technique":[{"value":2332,"label":"Gascromatografia (GC)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV4900-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/it\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":773,"name":"Video","slug":"video","term_group":0,"term_taxonomy_id":773,"taxonomy":"category","description":"","parent":0,"count":139,"filter":"raw","cat_ID":773,"category_count":139,"category_description":"","cat_name":"Video","category_nicename":"video","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/42602","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=42602"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/42602\/revisions"}],"predecessor-version":[{"id":76117,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/42602\/revisions\/76117"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media\/41488"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=42602"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=42602"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=42602"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=42602"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=42602"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=42602"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=42602"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=42602"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=42602"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}