{"id":43340,"date":"2020-10-07T14:30:00","date_gmt":"2020-10-07T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/analisi-lc-ms-ms-veloci-e-accurate-dellepimero-c3-della-25-idrossivitamina-d-con-le-colonne-raptor-fluorofeniliche\/"},"modified":"2026-01-28T21:59:08","modified_gmt":"2026-01-28T21:59:08","slug":"analisi-lc-ms-ms-veloci-e-accurate-dellepimero-c3-della-25-idrossivitamina-d-con-le-colonne-raptor-fluorofeniliche","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/articoli\/bass2523-it\/analisi-lc-ms-ms-veloci-e-accurate-dellepimero-c3-della-25-idrossivitamina-d-con-le-colonne-raptor-fluorofeniliche","title":{"rendered":"Analisi LC-MS\/MS veloci e accurate dell\u2019epimero C3 della 25-idrossivitamina D con le colonne Raptor fluorofeniliche"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>Il tempo di analisi di 5 minuti consente un numero maggiore di campioni al giorno.<\/li>\n\n\n\n<li>La separazione completa degli epimeri della vitamina D garantisce risultati accurati.<\/li>\n\n\n\n<li>Le colonne LC Raptor fluorofeniliche, robuste e durature, riducono il costo per campione.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Nella pratica clinica, le analisi della vitamina D sono aumentate in modo esponenziale, essendo correlate a diverse malattie, fra cui cancro, artrite reumatoide e diabete. La vitamina D ha un ruolo importante anche nell\u2019assorbimento del calcio e del fosforo per la resistenza ossea, quindi la carenza di tale vitamina \u00e8 una fonte di preoccupazione crescente in tutto il mondo. Un\u2019analisi LC accurata degli epimeri della vitamina D \u00e8 di fondamentale importanza per la determinazione quantitativa delle sue forme bioattive.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La vitamina D esiste in due forme, D2 e D3, che stimolano il metabolismo a formare, rispettivamente, le 25-idrossivitamine D2 e D3. Questi metaboliti vengono utilizzati come biomarcatori per valutare lo stato della vitamina D. Inoltre hanno entrambi una forma epimerica (3-epi-25-idrossivitamine D2 e D3), che contribuisce in maniera significativa alle concentrazioni totali delle 25-idrossivitamine D2 e D3. Alcuni studi hanno dimostrato che questi epimeri della vitamina D hanno una bioattivit\u00e0 decisamente inferiore rispetto ai metaboliti primari e quindi devono essere separati per evitare di sovrastimare i livelli di vitamina D.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La LC-MS\/MS \u00e8 una tecnica comune per le analisi della vitamina D, ma dato che i biomarcatori e i loro epimeri sono isobarici, la separazione cromatografica \u00e8 essenziale per ottenere una quantificazione precisa. Molti metodi pubblicati prevedono l\u2019utilizzo della colonna C18, ma la sua funzionalit\u00e0 \u00e8 limitata dalla risoluzione incompleta dei biomarcatori e dei rispettivi epimeri, nonch\u00e9 da un tempo di analisi di 10 minuti o pi\u00f9. La colonna Raptor fluorofenilica \u00e8 una scelta migliore perch\u00e9 presenta il vantaggio della selettivit\u00e0 alternata rispetto alla colonna C18 e separa completamente i biomarcatori e gli epimeri isobarici in soli 5 minuti. Come mostrato di seguito, le colonne Raptor fluorofeniliche migliorano le analisi LC degli epimeri della vitamina D, consentendo misurazioni accurate del contenuto di vitamina D per le indagini e il monitoraggio di malattie e carenze.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Le colonne Raptor FluoroPhenyl possono fornire una maggiore selettivit\u00e0 e ritenzione per gli analiti che non sono facilmente separabili utilizzando una colonna C18. Per esempio, le forme epimeriche dei metaboliti 25-idrossi delle vitamine D2 e D3 sono importanti marcatori diagnostici per lo stato della vitamina D, ma questi composti non possono essere distinti su una colonna C18. La nuova colonna Raptor FluoroPhenyl fornisce un&#8217;ampia risoluzione cromatografica per questi epimeri isobarici, che possiedono bioattivit\u00e0 disuguali, in modo da generare risultati accurati e poter effettuare la diagnosi corretta.<\/p>\n","protected":false},"author":11,"featured_media":89998,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[788],"tags":[],"industries-application":[2245,2246],"post-badge":[],"resource-type":[2768],"product-library":[2535,2517],"resource-technique":[2334,2364],"ppma_author":[414],"class_list":["post-43340","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articoli","industries-application-clinico","industries-application-diagnostica-clinica","resource-type-featured-application","product-library-colonne-lc","product-library-prodotti-per-cromatografia-liquida","resource-technique-cromatografia-liquida-lc","resource-technique-ms-ms-it"],"acf":[],"taxonomy_info":{"category":[{"value":788,"label":"Articoli"}],"industries-application":[{"value":2245,"label":"Clinico"},{"value":2246,"label":"Diagnostica clinica"}],"resource-type":[{"value":2768,"label":"Featured Application"}],"product-library":[{"value":2535,"label":"Colonne LC"},{"value":2517,"label":"Prodotti per Cromatografia Liquida"}],"resource-technique":[{"value":2334,"label":"Cromatografia Liquida (LC)"},{"value":2364,"label":"MS\/MS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-bass2523-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/it\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":788,"name":"Articoli","slug":"articoli","term_group":0,"term_taxonomy_id":788,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":788,"category_count":510,"category_description":"","cat_name":"Articoli","category_nicename":"articoli","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43340","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=43340"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43340\/revisions"}],"predecessor-version":[{"id":85747,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43340\/revisions\/85747"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media\/89998"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=43340"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=43340"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=43340"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=43340"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=43340"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=43340"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=43340"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=43340"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=43340"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}