{"id":43375,"date":"2024-09-10T00:00:00","date_gmt":"2024-09-10T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/substantial-benefits-of-an-inert-biphenyl-column-for-the-analysis-of-steroids-and-their-phase-ii-metabolites-in-biological-samples\/"},"modified":"2025-11-26T20:04:55","modified_gmt":"2025-11-26T20:04:55","slug":"substantial-benefits-of-an-inert-biphenyl-column-for-the-analysis-of-steroids-and-their-phase-ii-metabolites-in-biological-samples","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/articles\/cfot4356\/substantial-benefits-of-an-inert-biphenyl-column-for-the-analysis-of-steroids-and-their-phase-ii-metabolites-in-biological-samples","title":{"rendered":"Substantial Benefits of an Inert Biphenyl Column for the Analysis of Steroids and Their Phase II Metabolites in Biological Samples"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>Author(s): <\/strong>Mathieu Galmiche<sup>1,2,3<\/sup>, Marie-Ana\u00efs Monat<sup>1,2<\/sup>, Diego A. Lopez<sup>4<\/sup>, Cyrille Lamboley<sup>4<\/sup>, Paul Connolly<sup>4<\/sup>, Sergey Girel<sup>1,2<\/sup>, Davy Guillarme<sup>1,2<\/sup>, Isabel Meister<sup>1,2,3<\/sup>, Serge Rudaz<sup>1,2,3<\/sup><br>1. School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland, 2. Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland, 3. Swiss Centre for Applied Human Toxicology (SCAHT), Basel, Switzerland, 4. Restek Corporation, &nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Published By:<\/strong> Journal of Separation Science<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Issue:<\/strong> 16, Volume 47<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Year of Publication:<\/strong> 2024<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Link:<\/strong> <a href=\"https:\/\/doi.org\/10.1002\/jssc.202400436\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1002\/jssc.202400436<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Abstract:<\/strong> Steroids can be used as biomarkers in clinical metabolomics and other fields related to human toxicology. This chemical group is known for its complexity, considering its number of isobaric compounds and the wide variety of phases I and II metabolic pathways that parent compounds can undergo. For a successful analysis of steroids in biological samples, liquid chromatography separation must be finely tuned. It is especially challenging for glucuronidated and sulfated steroids derivatives that bear polar heads and can be affected by non-specific adsorption. The benefits of a biphenyl stationary phase chemistry for the selectivity of the separation of steroids and their phase II metabolites and the extent to which nonspecific adsorption phenomena could degrade chromatographic performance were investigated. Replacing a conventional hardware by a passivated hardware allowed to considerably reduce peaks width and asymmetry of sulfated species. The addition of weak ion pairing agents in the mobile phase could also help to reduce non-specific adsorption but are detrimental to mass spectrometry detection. As confirmed by the successful detection of 52 steroids in plasma, the use of a biphenyl stationary phase complemented by a passivated column hardware is of great help for a successful biomedical analysis of steroids and their phase II metabolites.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Acknowledgment(s):<\/strong> This analysis features Restek\u2019s Raptor Inert Biphenyl LC column (cat.# 9309A12-T). Learn more about our <a href=\"\/gnss4155\/accurately-analyze-metal-sensitive-compounds-with-resteks-new-inert-lc-columns\/\">inert LC column technology<\/a>.<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Prodotti Menzionati<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A12-T\">                                N\u00b0 Catalogo 9309A12-T                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Colonna HPLC Raptor Inert Bifenile, 2,7 \u00b5m, 100 x 2,1 mm<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A12-T\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>In this steroids analysis, replacing a conventional LC column with a passivated, inert LC column resulted in considerably reduced peak width and asymmetry of sulfated species.<\/p>\n","protected":false},"author":31,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[7],"tags":[],"industries-application":[2153,2156,2170,2171],"post-badge":[],"resource-type":[568],"product-library":[2391,2373],"resource-technique":[2299,2301],"ppma_author":[717,716,451,647,608,746,672,690,745],"class_list":["post-43375","post","type-post","status-publish","format-standard","hentry","category-articles","industries-application-clinical","industries-application-clinical-toxicology","industries-application-forensics","industries-application-forensics-toxicology","resource-type-third-party-peer-reviewed-publications","product-library-lc-columns","product-library-liquid-chromatography-products","resource-technique-liquid-chromatography","resource-technique-mass-spectrometry-ms"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"}],"industries-application":[{"value":2153,"label":"Clinical"},{"value":2156,"label":"Clinical Toxicology"},{"value":2170,"label":"Forensics"},{"value":2171,"label":"Forensics Toxicology"}],"resource-type":[{"value":568,"label":"Third-Party &amp; Peer Reviewed Publications"}],"product-library":[{"value":2391,"label":"LC Columns"},{"value":2373,"label":"Liquid Chromatography Products"}],"resource-technique":[{"value":2299,"label":"Liquid Chromatography"},{"value":2301,"label":"Mass Spectrometry (MS)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Diego L\u00f3pez","author_link":"https:\/\/discover.restek.com\/it\/author\/diego-lopez\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":7,"category_count":510,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":717,"user_id":0,"is_guest":1,"slug":"mathieu-galmiche","display_name":"Mathieu Galmiche","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Mathieu","last_name":"Galmiche","user_url":"","job_title":"","description":"School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland.\u00a0Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland.\u00a0Swiss Centre for Applied Human Toxicology (SCAHT), Basel, Switzerland"},{"term_id":716,"user_id":0,"is_guest":1,"slug":"marie-anais-monat","display_name":"Marie-Ana\u00efs Monat","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Marie-Ana\u00efs","last_name":"Monat","user_url":"","job_title":"","description":"School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland.\u00a0Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland"},{"term_id":451,"user_id":31,"is_guest":0,"slug":"diego-lopez","display_name":"Diego L\u00f3pez","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-lopez-diego.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-lopez-diego.jpg"},"author_category":"1","first_name":"Diego","last_name":"L\u00f3pez","user_url":"https:\/\/www.linkedin.com\/in\/diego-a-lopez\/","job_title":"Product Manager","description":"Diego is the product manager for sample preparation at Restek Corporation. He has over 10 years of experience in liquid chromatography for both chiral and achiral separations and holds a PhD in chemistry from The University of Texas at Arlington."},{"term_id":647,"user_id":0,"is_guest":1,"slug":"cyrille-lamboley","display_name":"Cyrille Lamboley","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Cyrille","last_name":"Lamboley","user_url":"","job_title":"","description":""},{"term_id":608,"user_id":53,"is_guest":0,"slug":"paul-connolly","display_name":"Paul Connolly","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-connolly-paul.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-connolly-paul.png"},"author_category":"1","first_name":"Paul","last_name":"Connolly","user_url":"","job_title":"","description":""},{"term_id":746,"user_id":0,"is_guest":1,"slug":"sergey-girel","display_name":"Sergey Girel","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Sergey","last_name":"Girel","user_url":"","job_title":"","description":"School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland.\u00a0Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland."},{"term_id":672,"user_id":0,"is_guest":1,"slug":"davy-guillarme","display_name":"Davy Guillarme","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Davy","last_name":"Guillarme","user_url":"","job_title":"","description":"School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland. Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland"},{"term_id":690,"user_id":0,"is_guest":1,"slug":"isabel-meister","display_name":"Isabel Meister","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Isabel","last_name":"Meister","user_url":"","job_title":"","description":"School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland. Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland. Swiss Centre for Applied Human Toxicology (SCAHT), Basel, Switzerland"},{"term_id":745,"user_id":0,"is_guest":1,"slug":"serge-rudaz","display_name":"Serge Rudaz","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Serge","last_name":"Rudaz","user_url":"","job_title":"","description":"School of Pharmaceutical Sciences, University of Geneva, Geneva, Switzerland.\u00a0Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, Geneva, Switzerland.\u00a0Swiss Centre for Applied Human Toxicology (SCAHT), Basel, Switzerland."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43375","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/31"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=43375"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43375\/revisions"}],"predecessor-version":[{"id":60475,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43375\/revisions\/60475"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=43375"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=43375"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=43375"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=43375"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=43375"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=43375"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=43375"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=43375"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=43375"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}