   {"id":43379,"date":"2020-10-12T00:00:00","date_gmt":"2020-10-12T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/analisi-dei-farmaci-via-il-dente-via-il-dolore-con-la-colonna-lc-raptor-bifenilica\/"},"modified":"2025-11-24T20:35:47","modified_gmt":"2025-11-24T20:35:47","slug":"analisi-dei-farmaci-via-il-dente-via-il-dolore-con-la-colonna-lc-raptor-bifenilica","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/articoli\/cfss2310-it\/analisi-dei-farmaci-via-il-dente-via-il-dolore-con-la-colonna-lc-raptor-bifenilica","title":{"rendered":"Analisi dei farmaci: via il dente via il dolore con la colonna LC Raptor bifenilica"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>231 composti, pi\u00f9 di 40 isobari, 10 classi di farmaci e 22 composti ESI in 10 minuti utilizzando 1 colonna.<\/li>\n\n\n\n<li>Una colonna LC SPP Raptor, grazie alla selettivit\u00e0 bifenilica targata Restek, testata e consolidata nel tempo, \u00e8 la colonna LC pi\u00f9 versatile e adatta alle analisi multiclasse disponibile sul mercato.<\/li>\n\n\n\n<li>Separazione eccellente degli isobari pi\u00f9 critici senza scodamento del picco.<\/li>\n\n\n\n<li>Analisi LC-MS\/MS veloci, affidabili e ad alto rendimento, con maggiore sensibilit\u00e0 utilizzando fasi mobili semplici.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Il consumo di antidolorifici \u00e8 in costante aumento. Di conseguenza, i laboratori ospedalieri e privati ricevono sempre pi\u00f9 campioni di screening per un ampio spettro di antidolorifici, per prevenire l\u2019abuso di farmaci e garantire la sicurezza dei pazienti e il rispetto del loro regime terapeutico. Il monitoraggio terapeutico dei farmaci pu\u00f2 essere complicato a causa dei valori soglia bassi, delle potenziali interferenze della matrice e dei composti isobarici di farmaci. Per affrontare queste sfide, molte strutture che effettuano test sui prodotti medicinali stanno passando alla cromatografia liquida abbinata alla spettrometria di massa (LC-MS\/MS) per la sua maggiore velocit\u00e0, sensibilit\u00e0 e specificit\u00e0.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Come mostra l\u2019analisi di seguito, la colonna Raptor bifenilica di Restek \u00e8 ideale per sviluppare metodologie LC-MS\/MS efficaci per lo screening degli antidolorifici. Grazie alla ritenzione estremamente elevata e alla selettivit\u00e0 unica \u00e8 possibile analizzare in soli 10 minuti 231 composti di farmaci multiclasse e metaboliti, tra cui oltre 40 isobari. Inoltre sono stati ottimizzati per la colonna Raptor bifenilica test tossicologici specifici per&nbsp;<a href=\"https:\/\/www.restek.com\/global\/it\/chromatogram-detail\/LC_CF0610\" target=\"_blank\" rel=\"noopener\">oppioidi<\/a>,&nbsp;<a href=\"https:\/\/www.restek.com\/global\/it\/chromatogram-detail\/LC_CF0615\" target=\"_blank\" rel=\"noopener\">ansiolitici<\/a>,&nbsp;<a href=\"https:\/\/www.restek.com\/global\/it\/chromatogram-detail\/LC_CF0619\" target=\"_blank\" rel=\"noopener\">barbiturici<\/a>,&nbsp;<a href=\"https:\/\/www.restek.com\/global\/it\/chromatogram-detail\/LC_CF0620\" target=\"_blank\" rel=\"noopener\">FANS e analgesici<\/a>,&nbsp;<a href=\"https:\/\/www.restek.com\/global\/it\/chromatogram-detail\/LC_CF0609\" target=\"_blank\" rel=\"noopener\">antidepressivi<\/a>,&nbsp;<a href=\"https:\/\/www.restek.com\/global\/it\/chromatogram-detail\/LC_CF0616\" target=\"_blank\" rel=\"noopener\">antipilettici<\/a>,&nbsp;<a href=\"https:\/\/www.restek.com\/global\/it\/chromatogram-detail\/LC_CF0608\" target=\"_blank\" rel=\"noopener\">antipsicotici<\/a>,&nbsp;<a href=\"https:\/\/www.restek.com\/global\/it\/chromatogram-detail\/LC_CF0607\" target=\"_blank\" rel=\"noopener\">allucinogeni<\/a>, e&nbsp;<a href=\"https:\/\/www.restek.com\/global\/it\/chromatogram-detail\/LC_CF0617\" target=\"_blank\" rel=\"noopener\">stimolanti<\/a>, da utilizzare durante le analisi quantitative e di conferma.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0621.png\" alt=\"Multiclass Drug Panel on Raptor Biphenyl by LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0621<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for trans-3-Hydroxycotinine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/34834-67-8\/trans-3-Hydroxycotinine\" target=\"_blank\" rel=\"noopener\">trans-3-Hydroxycotinine<\/a><\/td><td class=\"oth\">1.32<\/td><td class=\"oth\">25<\/td><td class=\"oth\">193.1<\/td><td class=\"oth\">80.0<\/td><td class=\"oth\">134.0<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norcotinine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/17708-87-1\/Norcotinine\" target=\"_blank\" rel=\"noopener\">Norcotinine<\/a><\/td><td class=\"oth\">1.33<\/td><td class=\"oth\">25<\/td><td class=\"oth\">163.1<\/td><td class=\"oth\">80.1<\/td><td class=\"oth\">118.1<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nicotine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/54-11-5\/Nicotine\" target=\"_blank\" rel=\"noopener\">Nicotine<\/a><\/td><td class=\"oth\">1.40<\/td><td class=\"oth\">25<\/td><td class=\"oth\">163.2<\/td><td class=\"oth\">130.1<\/td><td class=\"oth\">117.1<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for BZP\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2759-28-6\/BZP\" target=\"_blank\" rel=\"noopener\">BZP<\/a><\/td><td class=\"oth\">1.47<\/td><td class=\"oth\">25<\/td><td class=\"oth\">177.2<\/td><td class=\"oth\">91.1<\/td><td class=\"oth\">65.1<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Anabasine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/40774-73-0\/Anabasine\" target=\"_blank\" rel=\"noopener\">Anabasine<\/a><\/td><td class=\"oth\">1.53<\/td><td class=\"oth\">25<\/td><td class=\"oth\">163.2<\/td><td class=\"oth\">120.1<\/td><td class=\"oth\">80.1<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Noroxymorphone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/33522-95-1\/Noroxymorphone\" target=\"_blank\" rel=\"noopener\">Noroxymorphone<\/a><\/td><td class=\"oth\">1.78<\/td><td class=\"oth\">25<\/td><td class=\"oth\">288.1<\/td><td class=\"oth\">270.1<\/td><td class=\"oth\">212.9<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Lisdexamfetamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/608137-33-3\/Lisdexamfetamine\" target=\"_blank\" rel=\"noopener\">Lisdexamfetamine<\/a><\/td><td class=\"oth\">1.79<\/td><td class=\"oth\">25<\/td><td class=\"oth\">264.2<\/td><td class=\"oth\">84.1<\/td><td class=\"oth\">91.0<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenelzine sulfate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/156-51-4\/Phenelzine sulfate\" target=\"_blank\" rel=\"noopener\">Phenelzine sulfate<\/a><\/td><td class=\"oth\">1.90<\/td><td class=\"oth\">25<\/td><td class=\"oth\">137.2<\/td><td class=\"oth\">105.1<\/td><td class=\"oth\">77.1<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetaminophen\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/103-90-2\/Acetaminophen\" target=\"_blank\" rel=\"noopener\">Acetaminophen<\/a><\/td><td class=\"oth\">1.93<\/td><td class=\"oth\">100<\/td><td class=\"oth\">152.2<\/td><td class=\"oth\">93.0<\/td><td class=\"oth\">65.0<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pregabalin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/148553-50-8\/Pregabalin\" target=\"_blank\" rel=\"noopener\">Pregabalin<\/a><\/td><td class=\"oth\">2.21<\/td><td class=\"oth\">25<\/td><td class=\"oth\">160.2<\/td><td class=\"oth\">142.1<\/td><td class=\"oth\">55.0<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cotinine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/486-56-6\/Cotinine\" target=\"_blank\" rel=\"noopener\">Cotinine<\/a><\/td><td class=\"oth\">2.27<\/td><td class=\"oth\">25<\/td><td class=\"oth\">177.2<\/td><td class=\"oth\">80.0<\/td><td class=\"oth\">98.1<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Morphine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-27-2\/Morphine\" target=\"_blank\" rel=\"noopener\">Morphine<\/a><\/td><td class=\"oth\">2.27<\/td><td class=\"oth\">25<\/td><td class=\"oth\">286.2<\/td><td class=\"oth\">152.1<\/td><td class=\"oth\">165.0<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (+)-Ephedrine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/321-98-2\/(+)-Ephedrine\" target=\"_blank\" rel=\"noopener\">(+)-Ephedrine<\/a><\/td><td class=\"oth\">2.37<\/td><td class=\"oth\">25<\/td><td class=\"oth\">166.2<\/td><td class=\"oth\">148.1<\/td><td class=\"oth\">115.0<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxymorphone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-41-5\/Oxymorphone\" target=\"_blank\" rel=\"noopener\">Oxymorphone<\/a><\/td><td class=\"oth\">2.38<\/td><td class=\"oth\">25<\/td><td class=\"oth\">302.1<\/td><td class=\"oth\">227.2<\/td><td class=\"oth\">198.2<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hydromorphone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/466-99-9\/Hydromorphone\" target=\"_blank\" rel=\"noopener\">Hydromorphone<\/a><\/td><td class=\"oth\">2.61<\/td><td class=\"oth\">25<\/td><td class=\"oth\">286.2<\/td><td class=\"oth\">184.9<\/td><td class=\"oth\">156.9<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Amphetamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/300-62-9\/Amphetamine\" target=\"_blank\" rel=\"noopener\">Amphetamine<\/a><\/td><td class=\"oth\">2.63<\/td><td class=\"oth\">25<\/td><td class=\"oth\">136.2<\/td><td class=\"oth\">91.0<\/td><td class=\"oth\">65.1<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for DMAA\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/123-82-0\/DMAA\" target=\"_blank\" rel=\"noopener\">DMAA<\/a><\/td><td class=\"oth\">2.65<\/td><td class=\"oth\">25<\/td><td class=\"oth\">116.1<\/td><td class=\"oth\">57.1<\/td><td class=\"oth\">99.2<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Gabapentin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60142-96-3\/Gabapentin\" target=\"_blank\" rel=\"noopener\">Gabapentin<\/a><\/td><td class=\"oth\">2.71<\/td><td class=\"oth\">25<\/td><td class=\"oth\">172.2<\/td><td class=\"oth\">154.0<\/td><td class=\"oth\">137.1<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methylephedrine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/552-79-4\/Methylephedrine\" target=\"_blank\" rel=\"noopener\">Methylephedrine<\/a><\/td><td class=\"oth\">2.83<\/td><td class=\"oth\">25<\/td><td class=\"oth\">180.2<\/td><td class=\"oth\">162.0<\/td><td class=\"oth\">115.1<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Levetiracetam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/102767-28-2\/Levetiracetam\" target=\"_blank\" rel=\"noopener\">Levetiracetam<\/a><\/td><td class=\"oth\">2.84<\/td><td class=\"oth\">25<\/td><td class=\"oth\">171.1<\/td><td class=\"oth\">125.9<\/td><td class=\"oth\">69.2<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Desmethylolanzapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/161696-76-0\/Desmethylolanzapine\" target=\"_blank\" rel=\"noopener\">Desmethylolanzapine<\/a><\/td><td class=\"oth\">2.94<\/td><td class=\"oth\">25<\/td><td class=\"oth\">299.1<\/td><td class=\"oth\">256.1<\/td><td class=\"oth\">198.0<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norcodeine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/467-15-2\/Norcodeine\" target=\"_blank\" rel=\"noopener\">Norcodeine<\/a><\/td><td class=\"oth\">2.96<\/td><td class=\"oth\">25<\/td><td class=\"oth\">286.1<\/td><td class=\"oth\">151.9<\/td><td class=\"oth\">115.0<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Olanzapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/132539-06-1\/Olanzapine\" target=\"_blank\" rel=\"noopener\">Olanzapine<\/a><\/td><td class=\"oth\">3.12<\/td><td class=\"oth\">25<\/td><td class=\"oth\">313.2<\/td><td class=\"oth\">256.1<\/td><td class=\"oth\">198.1<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methamphetamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/537-46-2\/Methamphetamine\" target=\"_blank\" rel=\"noopener\">Methamphetamine<\/a><\/td><td class=\"oth\">3.13<\/td><td class=\"oth\">25<\/td><td class=\"oth\">150.3<\/td><td class=\"oth\">91.1<\/td><td class=\"oth\">119.0<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for MDA\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4764-17-4\/MDA\" target=\"_blank\" rel=\"noopener\">MDA<\/a><\/td><td class=\"oth\">3.18<\/td><td class=\"oth\">25<\/td><td class=\"oth\">180.1<\/td><td class=\"oth\">163.1<\/td><td class=\"oth\">105.2<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (-)-Naloxone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/465-65-6\/(-)-Naloxone\" target=\"_blank\" rel=\"noopener\">(-)-Naloxone<\/a><\/td><td class=\"oth\">3.27<\/td><td class=\"oth\">25<\/td><td class=\"oth\">328.3<\/td><td class=\"oth\">310.1<\/td><td class=\"oth\">212.3<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phentermine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/122-09-8\/Phentermine\" target=\"_blank\" rel=\"noopener\">Phentermine<\/a><\/td><td class=\"oth\">3.29<\/td><td class=\"oth\">25<\/td><td class=\"oth\">150.2<\/td><td class=\"oth\">91.1<\/td><td class=\"oth\">133.1<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Noroxycodone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57664-96-7\/Noroxycodone\" target=\"_blank\" rel=\"noopener\">Noroxycodone<\/a><\/td><td class=\"oth\">3.32<\/td><td class=\"oth\">25<\/td><td class=\"oth\">302.1<\/td><td class=\"oth\">227.0<\/td><td class=\"oth\">197.9<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methylone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/186028-79-5\/Methylone\" target=\"_blank\" rel=\"noopener\">Methylone<\/a><\/td><td class=\"oth\">3.36<\/td><td class=\"oth\">25<\/td><td class=\"oth\">208.1<\/td><td class=\"oth\">160.1<\/td><td class=\"oth\">132.1<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for O-Desmethyl-cis-tramadol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/144830-14-8\/O-Desmethyl-cis-tramadol\" target=\"_blank\" rel=\"noopener\">O-Desmethyl-cis-tramadol<\/a><\/td><td class=\"oth\">3.37<\/td><td class=\"oth\">25<\/td><td class=\"oth\">250.1<\/td><td class=\"oth\">58.0<\/td><td class=\"oth\">42.0<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (-)-Dihydrocodeine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/125-28-0\/(-)-Dihydrocodeine\" target=\"_blank\" rel=\"noopener\">(-)-Dihydrocodeine<\/a><\/td><td class=\"oth\">3.38<\/td><td class=\"oth\">25<\/td><td class=\"oth\">302.2<\/td><td class=\"oth\">199.0<\/td><td class=\"oth\">128.2<\/td><\/tr>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norhydrocodone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5083-62-5\/Norhydrocodone\" target=\"_blank\" rel=\"noopener\">Norhydrocodone<\/a><\/td><td class=\"oth\">3.43<\/td><td class=\"oth\">25<\/td><td class=\"oth\">286.1<\/td><td class=\"oth\">199.0<\/td><td class=\"oth\">128.2<\/td><\/tr>\n<tr><td class=\"num\">33.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Codeine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-57-3\/Codeine\" target=\"_blank\" rel=\"noopener\">Codeine<\/a><\/td><td class=\"oth\">3.43<\/td><td class=\"oth\">25<\/td><td class=\"oth\">300.2<\/td><td class=\"oth\">152.0<\/td><td class=\"oth\">165.1<\/td><\/tr>\n<tr><td class=\"num\">34.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 6-Acetylmorphine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2784-73-8\/6-Acetylmorphine\" target=\"_blank\" rel=\"noopener\">6-Acetylmorphine<\/a><\/td><td class=\"oth\">3.47<\/td><td class=\"oth\">25<\/td><td class=\"oth\">328.2<\/td><td class=\"oth\">165.0<\/td><td class=\"oth\">211.0<\/td><\/tr>\n<tr><td class=\"num\">35.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for MDMA\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/42542-10-9\/MDMA\" target=\"_blank\" rel=\"noopener\">MDMA<\/a><\/td><td class=\"oth\">3.60<\/td><td class=\"oth\">25<\/td><td class=\"oth\">194.2<\/td><td class=\"oth\">163.0<\/td><td class=\"oth\">135.1<\/td><\/tr>\n<tr><td class=\"num\">36.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Desomorphine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/427-00-9\/Desomorphine\" target=\"_blank\" rel=\"noopener\">Desomorphine<\/a><\/td><td class=\"oth\">3.61<\/td><td class=\"oth\">25<\/td><td class=\"oth\">272.1<\/td><td class=\"oth\">152.1<\/td><td class=\"oth\">165.0<\/td><\/tr>\n<tr><td class=\"num\">37.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxycodone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-42-6\/Oxycodone\" target=\"_blank\" rel=\"noopener\">Oxycodone<\/a><\/td><td class=\"oth\">3.64<\/td><td class=\"oth\">25<\/td><td class=\"oth\">316.2<\/td><td class=\"oth\">298.0<\/td><td class=\"oth\">169.0<\/td><\/tr>\n<tr><td class=\"num\">38.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Naltrexone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/16590-41-3\/Naltrexone\" target=\"_blank\" rel=\"noopener\">Naltrexone<\/a><\/td><td class=\"oth\">3.71<\/td><td class=\"oth\">25<\/td><td class=\"oth\">342.2<\/td><td class=\"oth\">324.0<\/td><td class=\"oth\">267.0<\/td><\/tr>\n<tr><td class=\"num\">39.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Levamisole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/14769-73-4\/Levamisole\" target=\"_blank\" rel=\"noopener\">Levamisole<\/a><\/td><td class=\"oth\">3.75<\/td><td class=\"oth\">25<\/td><td class=\"oth\">205.1<\/td><td class=\"oth\">178.0<\/td><td class=\"oth\">91.1<\/td><\/tr>\n<tr><td class=\"num\">40.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hydrocodone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/125-29-1\/Hydrocodone\" target=\"_blank\" rel=\"noopener\">Hydrocodone<\/a><\/td><td class=\"oth\">3.76<\/td><td class=\"oth\">25<\/td><td class=\"oth\">300.1<\/td><td class=\"oth\">199.0<\/td><td class=\"oth\">128.0<\/td><\/tr>\n<tr><td class=\"num\">41.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diethylpropion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-84-6\/Diethylpropion\" target=\"_blank\" rel=\"noopener\">Diethylpropion<\/a><\/td><td class=\"oth\">3.80<\/td><td class=\"oth\">25<\/td><td class=\"oth\">206.2<\/td><td class=\"oth\">105.1<\/td><td class=\"oth\">100.1<\/td><\/tr>\n<tr><td class=\"num\">42.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mephedrone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1189726-22-4\/Mephedrone\" target=\"_blank\" rel=\"noopener\">Mephedrone<\/a><\/td><td class=\"oth\">3.80<\/td><td class=\"oth\">25<\/td><td class=\"oth\">178.2<\/td><td class=\"oth\">145.0<\/td><td class=\"oth\">160.1<\/td><\/tr>\n<tr><td class=\"num\">43.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Oxo-3-hydroxy-LSD\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111295-09-1\/2-Oxo-3-hydroxy-LSD\" target=\"_blank\" rel=\"noopener\">2-Oxo-3-hydroxy-LSD<\/a><\/td><td class=\"oth\">3.82<\/td><td class=\"oth\">25<\/td><td class=\"oth\">356.3<\/td><td class=\"oth\">237.0<\/td><td class=\"oth\">222.0<\/td><\/tr>\n<tr><td class=\"num\">44.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for o-Desmethylvenlafaxine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/93413-62-8\/o-Desmethylvenlafaxine\" target=\"_blank\" rel=\"noopener\">o-Desmethylvenlafaxine<\/a><\/td><td class=\"oth\">3.84<\/td><td class=\"oth\">25<\/td><td class=\"oth\">264.1<\/td><td class=\"oth\">58.1<\/td><td class=\"oth\">107.0<\/td><\/tr>\n<tr><td class=\"num\">45.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 6-\u03b2-Naltrexol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/49625-89-0\/6-\u03b2-Naltrexol\" target=\"_blank\" rel=\"noopener\">6-\u03b2-Naltrexol<\/a><\/td><td class=\"oth\">3.91<\/td><td class=\"oth\">25<\/td><td class=\"oth\">344.3<\/td><td class=\"oth\">326.1<\/td><td class=\"oth\">308.1<\/td><\/tr>\n<tr><td class=\"num\">46.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tapentadol-\u03b2-D-glucuronide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1300037-86-8\/Tapentadol-\u03b2-D-glucuronide\" target=\"_blank\" rel=\"noopener\">Tapentadol-\u03b2-D-glucuronide<\/a><\/td><td class=\"oth\">3.91<\/td><td class=\"oth\">25<\/td><td class=\"oth\">398.3<\/td><td class=\"oth\">222.1<\/td><td class=\"oth\">107.0<\/td><\/tr>\n<tr><td class=\"num\">47.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 7-Aminonitrazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4928-02-3\/7-Aminonitrazepam\" target=\"_blank\" rel=\"noopener\">7-Aminonitrazepam<\/a><\/td><td class=\"oth\">3.95<\/td><td class=\"oth\">25<\/td><td class=\"oth\">252.2<\/td><td class=\"oth\">121.1<\/td><td class=\"oth\">94.2<\/td><\/tr>\n<tr><td class=\"num\">48.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for MDEA\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/82801-81-8\/MDEA\" target=\"_blank\" rel=\"noopener\">MDEA<\/a><\/td><td class=\"oth\">4.00<\/td><td class=\"oth\">25<\/td><td class=\"oth\">208.1<\/td><td class=\"oth\">163.0<\/td><td class=\"oth\">105.2<\/td><\/tr>\n<tr><td class=\"num\">49.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for m-Hydroxybenzoylecgonine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/129944-99-6\/m-Hydroxybenzoylecgonine\" target=\"_blank\" rel=\"noopener\">m-Hydroxybenzoylecgonine<\/a><\/td><td class=\"oth\">4.02<\/td><td class=\"oth\">25<\/td><td class=\"oth\">306.1<\/td><td class=\"oth\">168.1<\/td><td class=\"oth\">121.0<\/td><\/tr>\n<tr><td class=\"num\">50.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Lamotrigine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84057-84-1\/Lamotrigine\" target=\"_blank\" rel=\"noopener\">Lamotrigine<\/a><\/td><td class=\"oth\">4.09<\/td><td class=\"oth\">25<\/td><td class=\"oth\">256.0<\/td><td class=\"oth\">211.1<\/td><td class=\"oth\">145.0<\/td><\/tr>\n<tr><td class=\"num\">51.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ritalinic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/54631-24-2\/Ritalinic acid\" target=\"_blank\" rel=\"noopener\">Ritalinic acid<\/a><\/td><td class=\"oth\">4.11<\/td><td class=\"oth\">25<\/td><td class=\"oth\">220.1<\/td><td class=\"oth\">84.1<\/td><td class=\"oth\">56.2<\/td><\/tr>\n<tr><td class=\"num\">52.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Desmethyltapentadol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1246819-18-0\/N-Desmethyltapentadol\" target=\"_blank\" rel=\"noopener\">N-Desmethyltapentadol<\/a><\/td><td class=\"oth\">4.16<\/td><td class=\"oth\">25<\/td><td class=\"oth\">208.1<\/td><td class=\"oth\">121.2<\/td><td class=\"oth\">107.1<\/td><\/tr>\n<tr><td class=\"num\">53.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norbuprenorphine glucuronide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/469887-29-4\/Norbuprenorphine glucuronide\" target=\"_blank\" rel=\"noopener\">Norbuprenorphine glucuronide<\/a><\/td><td class=\"oth\">4.18<\/td><td class=\"oth\">25<\/td><td class=\"oth\">590.5<\/td><td class=\"oth\">414.3<\/td><td class=\"oth\">165.0<\/td><\/tr>\n<tr><td class=\"num\">54.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Zonisamide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68291-97-4\/Zonisamide\" target=\"_blank\" rel=\"noopener\">Zonisamide<\/a><\/td><td class=\"oth\">4.23<\/td><td class=\"oth\">25<\/td><td class=\"oth\">212.9<\/td><td class=\"oth\">132.1<\/td><td class=\"oth\">77.1<\/td><\/tr>\n<tr><td class=\"num\">55.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for mCPP\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/6640-24-0\/mCPP\" target=\"_blank\" rel=\"noopener\">mCPP<\/a><\/td><td class=\"oth\">4.26<\/td><td class=\"oth\">25<\/td><td class=\"oth\">197.1<\/td><td class=\"oth\">154.0<\/td><td class=\"oth\">118.1<\/td><\/tr>\n<tr><td class=\"num\">56.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norketamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/79499-59-5\/Norketamine\" target=\"_blank\" rel=\"noopener\">Norketamine<\/a><\/td><td class=\"oth\">4.28<\/td><td class=\"oth\">25<\/td><td class=\"oth\">224.1<\/td><td class=\"oth\">125.0<\/td><td class=\"oth\">89.1<\/td><\/tr>\n<tr><td class=\"num\">57.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nalbuphine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/20594-83-6\/Nalbuphine\" target=\"_blank\" rel=\"noopener\">Nalbuphine<\/a><\/td><td class=\"oth\">4.33<\/td><td class=\"oth\">25<\/td><td class=\"oth\">358.2<\/td><td class=\"oth\">340.1<\/td><td class=\"oth\">115.0<\/td><\/tr>\n<tr><td class=\"num\">58.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norfentanyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1609-66-1\/Norfentanyl\" target=\"_blank\" rel=\"noopener\">Norfentanyl<\/a><\/td><td class=\"oth\">4.33<\/td><td class=\"oth\">25<\/td><td class=\"oth\">233.1<\/td><td class=\"oth\">84.1<\/td><td class=\"oth\">55.0<\/td><\/tr>\n<tr><td class=\"num\">59.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (+\/-)-Hydroxybupropion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92264-81-8\/(+_-)-Hydroxybupropion\" target=\"_blank\" rel=\"noopener\">(+\/-)-Hydroxybupropion<\/a><\/td><td class=\"oth\">4.35<\/td><td class=\"oth\">25<\/td><td class=\"oth\">256.0<\/td><td class=\"oth\">130.2<\/td><td class=\"oth\">166.0<\/td><\/tr>\n<tr><td class=\"num\">60.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tapentadol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/175591-23-8\/Tapentadol\" target=\"_blank\" rel=\"noopener\">Tapentadol<\/a><\/td><td class=\"oth\">4.37<\/td><td class=\"oth\">25<\/td><td class=\"oth\">222.1<\/td><td class=\"oth\">107.1<\/td><td class=\"oth\">121.0<\/td><\/tr>\n<tr><td class=\"num\">61.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Lacosamide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/175481-36-4\/Lacosamide\" target=\"_blank\" rel=\"noopener\">Lacosamide<\/a><\/td><td class=\"oth\">4.47<\/td><td class=\"oth\">25<\/td><td class=\"oth\">251.5<\/td><td class=\"oth\">91.1<\/td><td class=\"oth\">108.1<\/td><\/tr>\n<tr><td class=\"num\">62.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dextrorphan\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/125-73-5\/Dextrorphan\" target=\"_blank\" rel=\"noopener\">Dextrorphan<\/a><\/td><td class=\"oth\">4.50<\/td><td class=\"oth\">25<\/td><td class=\"oth\">258.2<\/td><td class=\"oth\">157.0<\/td><td class=\"oth\">201.2<\/td><\/tr>\n<tr><td class=\"num\">63.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Levorphanol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/77-07-6\/Levorphanol\" target=\"_blank\" rel=\"noopener\">Levorphanol<\/a><\/td><td class=\"oth\">4.50<\/td><td class=\"oth\">25<\/td><td class=\"oth\">258.2<\/td><td class=\"oth\">156.8<\/td><td class=\"oth\">199.2<\/td><\/tr>\n<tr><td class=\"num\">64.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 7-Hydroxyquetiapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/139079-39-3\/7-Hydroxyquetiapine\" target=\"_blank\" rel=\"noopener\">7-Hydroxyquetiapine<\/a><\/td><td class=\"oth\">4.51<\/td><td class=\"oth\">25<\/td><td class=\"oth\">400.3<\/td><td class=\"oth\">269.0<\/td><td class=\"oth\">208.0<\/td><\/tr>\n<tr><td class=\"num\">65.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Molindone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7416-34-4\/Molindone\" target=\"_blank\" rel=\"noopener\">Molindone<\/a><\/td><td class=\"oth\">4.51<\/td><td class=\"oth\">25<\/td><td class=\"oth\">277.2<\/td><td class=\"oth\">100.1<\/td><td class=\"oth\">70.2<\/td><\/tr>\n<tr><td class=\"num\">66.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tramadol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/27203-92-5\/Tramadol\" target=\"_blank\" rel=\"noopener\">Tramadol<\/a><\/td><td class=\"oth\">4.52<\/td><td class=\"oth\">25<\/td><td class=\"oth\">264.2<\/td><td class=\"oth\">58.0<\/td><td class=\"oth\">77.1<\/td><\/tr>\n<tr><td class=\"num\">67.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Zolpidem phenyl-4-carboxylic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/109461-65-6\/Zolpidem phenyl-4-carboxylic acid\" target=\"_blank\" rel=\"noopener\">Zolpidem phenyl-4-carboxylic acid<\/a><\/td><td class=\"oth\">4.60<\/td><td class=\"oth\">25<\/td><td class=\"oth\">338.2<\/td><td class=\"oth\">265.1<\/td><td class=\"oth\">219.0<\/td><\/tr>\n<tr><td class=\"num\">68.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Felbamate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/25451-15-4\/Felbamate\" target=\"_blank\" rel=\"noopener\">Felbamate<\/a><\/td><td class=\"oth\">4.62<\/td><td class=\"oth\">25<\/td><td class=\"oth\">239.1<\/td><td class=\"oth\">117.1<\/td><td class=\"oth\">177.8<\/td><\/tr>\n<tr><td class=\"num\">69.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Desmethyl-cis-tramadol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1018989-94-0\/N-Desmethyl-cis-tramadol\" target=\"_blank\" rel=\"noopener\">N-Desmethyl-cis-tramadol<\/a><\/td><td class=\"oth\">4.65<\/td><td class=\"oth\">25<\/td><td class=\"oth\">250.2<\/td><td class=\"oth\">44.0<\/td><td class=\"oth\">232.1<\/td><\/tr>\n<tr><td class=\"num\">70.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ketamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/6740-88-1\/Ketamine\" target=\"_blank\" rel=\"noopener\">Ketamine<\/a><\/td><td class=\"oth\">4.66<\/td><td class=\"oth\">25<\/td><td class=\"oth\">238.1<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">89.1<\/td><\/tr>\n<tr><td class=\"num\">71.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzoylecgonine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/519-09-5\/Benzoylecgonine\" target=\"_blank\" rel=\"noopener\">Benzoylecgonine<\/a><\/td><td class=\"oth\">4.67<\/td><td class=\"oth\">25<\/td><td class=\"oth\">290.1<\/td><td class=\"oth\">168.1<\/td><td class=\"oth\">77.1<\/td><\/tr>\n<tr><td class=\"num\">72.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methylphenidate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/113-45-1\/Methylphenidate\" target=\"_blank\" rel=\"noopener\">Methylphenidate<\/a><\/td><td class=\"oth\">4.68<\/td><td class=\"oth\">25<\/td><td class=\"oth\">234.1<\/td><td class=\"oth\">84.1<\/td><td class=\"oth\">56.1<\/td><\/tr>\n<tr><td class=\"num\">73.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Normeperidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/77-17-8\/Normeperidine\" target=\"_blank\" rel=\"noopener\">Normeperidine<\/a><\/td><td class=\"oth\">4.76<\/td><td class=\"oth\">25<\/td><td class=\"oth\">234.1<\/td><td class=\"oth\">160.2<\/td><td class=\"oth\">91.0<\/td><\/tr>\n<tr><td class=\"num\">74.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Meprobamate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-53-4\/Meprobamate\" target=\"_blank\" rel=\"noopener\">Meprobamate<\/a><\/td><td class=\"oth\">4.79<\/td><td class=\"oth\">25<\/td><td class=\"oth\">219.1<\/td><td class=\"oth\">158.2<\/td><td class=\"oth\">97.0<\/td><\/tr>\n<tr><td class=\"num\">75.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Meperidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-42-1\/Meperidine\" target=\"_blank\" rel=\"noopener\">Meperidine<\/a><\/td><td class=\"oth\">4.80<\/td><td class=\"oth\">25<\/td><td class=\"oth\">248.1<\/td><td class=\"oth\">220.1<\/td><td class=\"oth\">174.1<\/td><\/tr>\n<tr><td class=\"num\">76.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bupropion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/34911-55-2\/Bupropion\" target=\"_blank\" rel=\"noopener\">Bupropion<\/a><\/td><td class=\"oth\">4.81<\/td><td class=\"oth\">25<\/td><td class=\"oth\">240.0<\/td><td class=\"oth\">184.1<\/td><td class=\"oth\">130.2<\/td><\/tr>\n<tr><td class=\"num\">77.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Heroin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/561-27-3\/Heroin\" target=\"_blank\" rel=\"noopener\">Heroin<\/a><\/td><td class=\"oth\">4.85<\/td><td class=\"oth\">25<\/td><td class=\"oth\">370.4<\/td><td class=\"oth\">328.2<\/td><td class=\"oth\">164.9<\/td><\/tr>\n<tr><td class=\"num\">78.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cocaine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-36-2\/Cocaine\" target=\"_blank\" rel=\"noopener\">Cocaine<\/a><\/td><td class=\"oth\">5.01<\/td><td class=\"oth\">25<\/td><td class=\"oth\">304.2<\/td><td class=\"oth\">182.0<\/td><td class=\"oth\">77.1<\/td><\/tr>\n<tr><td class=\"num\">79.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 7-Aminoclonazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4959-17-5\/7-Aminoclonazepam\" target=\"_blank\" rel=\"noopener\">7-Aminoclonazepam<\/a><\/td><td class=\"oth\">5.02<\/td><td class=\"oth\">25<\/td><td class=\"oth\">286.1<\/td><td class=\"oth\">121.2<\/td><td class=\"oth\">250.1<\/td><\/tr>\n<tr><td class=\"num\">80.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Zopiclone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/43200-80-2\/Zopiclone\" target=\"_blank\" rel=\"noopener\">Zopiclone<\/a><\/td><td class=\"oth\">5.04<\/td><td class=\"oth\">25<\/td><td class=\"oth\">389.2<\/td><td class=\"oth\">245.0<\/td><td class=\"oth\">217.2<\/td><\/tr>\n<tr><td class=\"num\">81.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Desmethylmirtazapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/61337-68-6\/N-Desmethylmirtazapine\" target=\"_blank\" rel=\"noopener\">N-Desmethylmirtazapine<\/a><\/td><td class=\"oth\">5.10<\/td><td class=\"oth\">25<\/td><td class=\"oth\">252.1<\/td><td class=\"oth\">195.1<\/td><td class=\"oth\">209.2<\/td><\/tr>\n<tr><td class=\"num\">82.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norcocaine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/18717-72-1\/Norcocaine\" target=\"_blank\" rel=\"noopener\">Norcocaine<\/a><\/td><td class=\"oth\">5.11<\/td><td class=\"oth\">25<\/td><td class=\"oth\">290.1<\/td><td class=\"oth\">168.0<\/td><td class=\"oth\">136.1<\/td><\/tr>\n<tr><td class=\"num\">83.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenobarbital*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-06-6\/Phenobarbital\" target=\"_blank\" rel=\"noopener\">Phenobarbital*<\/a><\/td><td class=\"oth\">5.11<\/td><td class=\"oth\">500<\/td><td class=\"oth\">230.9<\/td><td class=\"oth\">187.8<\/td><td class=\"oth\">85.0<\/td><\/tr>\n<tr><td class=\"num\">84.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Buprenorphine glucuronide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101224-22-0\/Buprenorphine glucuronide\" target=\"_blank\" rel=\"noopener\">Buprenorphine glucuronide<\/a><\/td><td class=\"oth\">5.12<\/td><td class=\"oth\">25<\/td><td class=\"oth\">644.3<\/td><td class=\"oth\">468.2<\/td><td class=\"oth\">55.1<\/td><\/tr>\n<tr><td class=\"num\">85.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for MDPV\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/24622-62-6\/MDPV\" target=\"_blank\" rel=\"noopener\">MDPV<\/a><\/td><td class=\"oth\">5.15<\/td><td class=\"oth\">25<\/td><td class=\"oth\">276.2<\/td><td class=\"oth\">135.1<\/td><td class=\"oth\">126.1<\/td><\/tr>\n<tr><td class=\"num\">86.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Venlafaxine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/93413-69-5\/Venlafaxine\" target=\"_blank\" rel=\"noopener\">Venlafaxine<\/a><\/td><td class=\"oth\">5.15<\/td><td class=\"oth\">25<\/td><td class=\"oth\">278.4<\/td><td class=\"oth\">260.4<\/td><td class=\"oth\">121.2<\/td><\/tr>\n<tr><td class=\"num\">87.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Milnacipran\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92623-85-3\/Milnacipran\" target=\"_blank\" rel=\"noopener\">Milnacipran<\/a><\/td><td class=\"oth\">5.24<\/td><td class=\"oth\">25<\/td><td class=\"oth\">247.2<\/td><td class=\"oth\">100.1<\/td><td class=\"oth\">129.1<\/td><\/tr>\n<tr><td class=\"num\">88.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentazocine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/359-83-1\/Pentazocine\" target=\"_blank\" rel=\"noopener\">Pentazocine<\/a><\/td><td class=\"oth\">5.29<\/td><td class=\"oth\">25<\/td><td class=\"oth\">286.2<\/td><td class=\"oth\">218.1<\/td><td class=\"oth\">69.2<\/td><\/tr>\n<tr><td class=\"num\">89.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mirtazapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85650-52-8\/Mirtazapine\" target=\"_blank\" rel=\"noopener\">Mirtazapine<\/a><\/td><td class=\"oth\">5.31<\/td><td class=\"oth\">25<\/td><td class=\"oth\">266.1<\/td><td class=\"oth\">195.1<\/td><td class=\"oth\">72.1<\/td><\/tr>\n<tr><td class=\"num\">90.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Butalbital*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/77-26-9\/Butalbital\" target=\"_blank\" rel=\"noopener\">Butalbital*<\/a><\/td><td class=\"oth\">5.31<\/td><td class=\"oth\">500<\/td><td class=\"oth\">223.0<\/td><td class=\"oth\">180.0<\/td><td class=\"oth\">84.9<\/td><\/tr>\n<tr><td class=\"num\">91.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norbuprenorphine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78715-23-8\/Norbuprenorphine\" target=\"_blank\" rel=\"noopener\">Norbuprenorphine<\/a><\/td><td class=\"oth\">5.35<\/td><td class=\"oth\">50<\/td><td class=\"oth\">414.3<\/td><td class=\"oth\">152.2<\/td><td class=\"oth\">165.2<\/td><\/tr>\n<tr><td class=\"num\">92.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for LSD\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-37-3\/LSD\" target=\"_blank\" rel=\"noopener\">LSD<\/a><\/td><td class=\"oth\">5.39<\/td><td class=\"oth\">25<\/td><td class=\"oth\">324.3<\/td><td class=\"oth\">223.1<\/td><td class=\"oth\">208.0<\/td><\/tr>\n<tr><td class=\"num\">93.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Butorphanol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/42408-82-2\/Butorphanol\" target=\"_blank\" rel=\"noopener\">Butorphanol<\/a><\/td><td class=\"oth\">5.43<\/td><td class=\"oth\">25<\/td><td class=\"oth\">328.3<\/td><td class=\"oth\">310.3<\/td><td class=\"oth\">131.2<\/td><\/tr>\n<tr><td class=\"num\">94.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fosphenytoin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/93390-81-9\/Fosphenytoin\" target=\"_blank\" rel=\"noopener\">Fosphenytoin<\/a><\/td><td class=\"oth\">5.43<\/td><td class=\"oth\">25<\/td><td class=\"oth\">363.1<\/td><td class=\"oth\">265.9<\/td><td class=\"oth\">207.8<\/td><\/tr>\n<tr><td class=\"num\">95.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Topiramate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/97240-79-4\/Topiramate\" target=\"_blank\" rel=\"noopener\">Topiramate<\/a><\/td><td class=\"oth\">5.44<\/td><td class=\"oth\">25<\/td><td class=\"oth\">340.2<\/td><td class=\"oth\">264.2<\/td><td class=\"oth\">223.9<\/td><\/tr>\n<tr><td class=\"num\">96.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cocaethylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/529-38-4\/Cocaethylene\" target=\"_blank\" rel=\"noopener\">Cocaethylene<\/a><\/td><td class=\"oth\">5.48<\/td><td class=\"oth\">25<\/td><td class=\"oth\">318.2<\/td><td class=\"oth\">196.1<\/td><td class=\"oth\">82.0<\/td><\/tr>\n<tr><td class=\"num\">97.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Clozapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5786-21-0\/Clozapine\" target=\"_blank\" rel=\"noopener\">Clozapine<\/a><\/td><td class=\"oth\">5.48<\/td><td class=\"oth\">25<\/td><td class=\"oth\">328.2<\/td><td class=\"oth\">271.1<\/td><td class=\"oth\">193.1<\/td><\/tr>\n<tr><td class=\"num\">98.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 9-Hydroxyrisperidone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/144598-75-4\/9-Hydroxyrisperidone\" target=\"_blank\" rel=\"noopener\">9-Hydroxyrisperidone<\/a><\/td><td class=\"oth\">5.51<\/td><td class=\"oth\">25<\/td><td class=\"oth\">427.3<\/td><td class=\"oth\">207.1<\/td><td class=\"oth\">110.2<\/td><\/tr>\n<tr><td class=\"num\">99.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetyl fentanyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3258-84-2\/Acetyl fentanyl\" target=\"_blank\" rel=\"noopener\">Acetyl fentanyl<\/a><\/td><td class=\"oth\">5.58<\/td><td class=\"oth\">25<\/td><td class=\"oth\">323.3<\/td><td class=\"oth\">188.0<\/td><td class=\"oth\">105.0<\/td><\/tr>\n<tr><td class=\"num\">100.<\/td><td class=\"cmpd\">Didesmethyl citalopram HCl<\/td><td class=\"oth\">5.73<\/td><td class=\"oth\">25<\/td><td class=\"oth\">297.1<\/td><td class=\"oth\">261.9<\/td><td class=\"oth\">109.1<\/td><\/tr>\n<tr><td class=\"num\">101.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 7-Aminoflunitrazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/34084-50-9\/7-Aminoflunitrazepam\" target=\"_blank\" rel=\"noopener\">7-Aminoflunitrazepam<\/a><\/td><td class=\"oth\">5.75<\/td><td class=\"oth\">25<\/td><td class=\"oth\">284.1<\/td><td class=\"oth\">135.0<\/td><td class=\"oth\">227.1<\/td><\/tr>\n<tr><td class=\"num\">102.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Amobarbital*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-43-2\/Amobarbital\" target=\"_blank\" rel=\"noopener\">Amobarbital*<\/a><\/td><td class=\"oth\">5.75<\/td><td class=\"oth\">500<\/td><td class=\"oth\">225.0<\/td><td class=\"oth\">182.0<\/td><td class=\"oth\">84.8<\/td><\/tr>\n<tr><td class=\"num\">103.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Zolpidem\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/82626-48-0\/Zolpidem\" target=\"_blank\" rel=\"noopener\">Zolpidem<\/a><\/td><td class=\"oth\">5.76<\/td><td class=\"oth\">25<\/td><td class=\"oth\">308.2<\/td><td class=\"oth\">235.2<\/td><td class=\"oth\">218.9<\/td><\/tr>\n<tr><td class=\"num\">104.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Desmethylcitalopram\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62498-67-3\/N-Desmethylcitalopram\" target=\"_blank\" rel=\"noopener\">N-Desmethylcitalopram<\/a><\/td><td class=\"oth\">5.77<\/td><td class=\"oth\">25<\/td><td class=\"oth\">311.1<\/td><td class=\"oth\">262.1<\/td><td class=\"oth\">109.1<\/td><\/tr>\n<tr><td class=\"num\">105.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isocarboxazid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59-63-2\/Isocarboxazid\" target=\"_blank\" rel=\"noopener\">Isocarboxazid<\/a><\/td><td class=\"oth\">5.77<\/td><td class=\"oth\">25<\/td><td class=\"oth\">232.0<\/td><td class=\"oth\">91.1<\/td><td class=\"oth\">65.2<\/td><\/tr>\n<tr><td class=\"num\">106.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentobarbital*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-74-4\/Pentobarbital\" target=\"_blank\" rel=\"noopener\">Pentobarbital*<\/a><\/td><td class=\"oth\">5.79<\/td><td class=\"oth\">500<\/td><td class=\"oth\">225.0<\/td><td class=\"oth\">182.0<\/td><td class=\"oth\">84.9<\/td><\/tr>\n<tr><td class=\"num\">107.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Escitalopram\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/128196-01-0\/Escitalopram\" target=\"_blank\" rel=\"noopener\">Escitalopram<\/a><\/td><td class=\"oth\">5.80<\/td><td class=\"oth\">25<\/td><td class=\"oth\">325.3<\/td><td class=\"oth\">109.1<\/td><td class=\"oth\">261.9<\/td><\/tr>\n<tr><td class=\"num\">108.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Citalopram\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59729-33-8\/Citalopram\" target=\"_blank\" rel=\"noopener\">Citalopram<\/a><\/td><td class=\"oth\">5.80<\/td><td class=\"oth\">25<\/td><td class=\"oth\">325.2<\/td><td class=\"oth\">109.1<\/td><td class=\"oth\">262.0<\/td><\/tr>\n<tr><td class=\"num\">109.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diphenhydramine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/58-73-1\/Diphenhydramine\" target=\"_blank\" rel=\"noopener\">Diphenhydramine<\/a><\/td><td class=\"oth\">5.80<\/td><td class=\"oth\">25<\/td><td class=\"oth\">256.1<\/td><td class=\"oth\">167.0<\/td><td class=\"oth\">152.1<\/td><\/tr>\n<tr><td class=\"num\">110.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Desmethyldoxepin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1225-56-5\/Desmethyldoxepin\" target=\"_blank\" rel=\"noopener\">Desmethyldoxepin<\/a><\/td><td class=\"oth\">5.88<\/td><td class=\"oth\">25<\/td><td class=\"oth\">266.1<\/td><td class=\"oth\">107.1<\/td><td class=\"oth\">115.0<\/td><\/tr>\n<tr><td class=\"num\">111.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ezogabine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/150812-12-7\/Ezogabine\" target=\"_blank\" rel=\"noopener\">Ezogabine<\/a><\/td><td class=\"oth\">5.91<\/td><td class=\"oth\">25<\/td><td class=\"oth\">304.0<\/td><td class=\"oth\">230.1<\/td><td class=\"oth\">109.1<\/td><\/tr>\n<tr><td class=\"num\">112.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Doxepin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1668-19-5\/Doxepin\" target=\"_blank\" rel=\"noopener\">Doxepin<\/a><\/td><td class=\"oth\">5.96<\/td><td class=\"oth\">25<\/td><td class=\"oth\">280.1<\/td><td class=\"oth\">107.2<\/td><td class=\"oth\">77.1<\/td><\/tr>\n<tr><td class=\"num\">113.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Haloperidol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52-86-8\/Haloperidol\" target=\"_blank\" rel=\"noopener\">Haloperidol<\/a><\/td><td class=\"oth\">5.96<\/td><td class=\"oth\">25<\/td><td class=\"oth\">377.2<\/td><td class=\"oth\">123.0<\/td><td class=\"oth\">95.1<\/td><\/tr>\n<tr><td class=\"num\">114.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluvoxamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/54739-18-3\/Fluvoxamine\" target=\"_blank\" rel=\"noopener\">Fluvoxamine<\/a><\/td><td class=\"oth\">5.97<\/td><td class=\"oth\">25<\/td><td class=\"oth\">319.3<\/td><td class=\"oth\">71.1<\/td><td class=\"oth\">257.8<\/td><\/tr>\n<tr><td class=\"num\">115.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Trazodone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/19794-93-5\/Trazodone\" target=\"_blank\" rel=\"noopener\">Trazodone<\/a><\/td><td class=\"oth\">5.99<\/td><td class=\"oth\">25<\/td><td class=\"oth\">372.3<\/td><td class=\"oth\">176.1<\/td><td class=\"oth\">148.0<\/td><\/tr>\n<tr><td class=\"num\">116.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norfluoxetine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56161-73-0\/Norfluoxetine\" target=\"_blank\" rel=\"noopener\">Norfluoxetine<\/a><\/td><td class=\"oth\">6.01<\/td><td class=\"oth\">25<\/td><td class=\"oth\">296.3<\/td><td class=\"oth\">134.3<\/td><td class=\"oth\">104.9<\/td><\/tr>\n<tr><td class=\"num\">117.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fentanyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/437-38-7\/Fentanyl\" target=\"_blank\" rel=\"noopener\">Fentanyl<\/a><\/td><td class=\"oth\">6.02<\/td><td class=\"oth\">25<\/td><td class=\"oth\">337.3<\/td><td class=\"oth\">188.0<\/td><td class=\"oth\">105.1<\/td><\/tr>\n<tr><td class=\"num\">118.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxcarbazepine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/28721-07-5\/Oxcarbazepine\" target=\"_blank\" rel=\"noopener\">Oxcarbazepine<\/a><\/td><td class=\"oth\">6.02<\/td><td class=\"oth\">25<\/td><td class=\"oth\">253.1<\/td><td class=\"oth\">180.0<\/td><td class=\"oth\">208.1<\/td><\/tr>\n<tr><td class=\"num\">119.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Risperidone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106266-06-2\/Risperidone\" target=\"_blank\" rel=\"noopener\">Risperidone<\/a><\/td><td class=\"oth\">6.03<\/td><td class=\"oth\">25<\/td><td class=\"oth\">411.2<\/td><td class=\"oth\">191.0<\/td><td class=\"oth\">110.1<\/td><\/tr>\n<tr><td class=\"num\">120.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Buprenorphine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52485-79-7\/Buprenorphine\" target=\"_blank\" rel=\"noopener\">Buprenorphine<\/a><\/td><td class=\"oth\">6.04<\/td><td class=\"oth\">50<\/td><td class=\"oth\">468.3<\/td><td class=\"oth\">55.1<\/td><td class=\"oth\">414.2<\/td><\/tr>\n<tr><td class=\"num\">121.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluoxetine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/54910-89-3\/Fluoxetine\" target=\"_blank\" rel=\"noopener\">Fluoxetine<\/a><\/td><td class=\"oth\">6.05<\/td><td class=\"oth\">25<\/td><td class=\"oth\">310.1<\/td><td class=\"oth\">148.0<\/td><td class=\"oth\">115.1<\/td><\/tr>\n<tr><td class=\"num\">122.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Secobarbital*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-73-3\/Secobarbital\" target=\"_blank\" rel=\"noopener\">Secobarbital*<\/a><\/td><td class=\"oth\">6.08<\/td><td class=\"oth\">500<\/td><td class=\"oth\">237.0<\/td><td class=\"oth\">193.9<\/td><td class=\"oth\">84.8<\/td><\/tr>\n<tr><td class=\"num\">123.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenytoin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-41-0\/Phenytoin\" target=\"_blank\" rel=\"noopener\">Phenytoin<\/a><\/td><td class=\"oth\">6.12<\/td><td class=\"oth\">25<\/td><td class=\"oth\">253.0<\/td><td class=\"oth\">103.9<\/td><td class=\"oth\">181.7<\/td><\/tr>\n<tr><td class=\"num\">124.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carisoprodol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78-44-4\/Carisoprodol\" target=\"_blank\" rel=\"noopener\">Carisoprodol<\/a><\/td><td class=\"oth\">6.13<\/td><td class=\"oth\">25<\/td><td class=\"oth\">261.1<\/td><td class=\"oth\">176.0<\/td><td class=\"oth\">62.0<\/td><\/tr>\n<tr><td class=\"num\">125.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flurazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/17617-23-1\/Flurazepam\" target=\"_blank\" rel=\"noopener\">Flurazepam<\/a><\/td><td class=\"oth\">6.14<\/td><td class=\"oth\">25<\/td><td class=\"oth\">388.2<\/td><td class=\"oth\">315.2<\/td><td class=\"oth\">183.0<\/td><\/tr>\n<tr><td class=\"num\">126.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlordiazepoxide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/58-25-3\/Chlordiazepoxide\" target=\"_blank\" rel=\"noopener\">Chlordiazepoxide<\/a><\/td><td class=\"oth\">6.14<\/td><td class=\"oth\">25<\/td><td class=\"oth\">300.1<\/td><td class=\"oth\">282.0<\/td><td class=\"oth\">227.0<\/td><\/tr>\n<tr><td class=\"num\">127.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dextromethorphan\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/125-71-3\/Dextromethorphan\" target=\"_blank\" rel=\"noopener\">Dextromethorphan<\/a><\/td><td class=\"oth\">6.16<\/td><td class=\"oth\">25<\/td><td class=\"oth\">272.2<\/td><td class=\"oth\">215.1<\/td><td class=\"oth\">170.9<\/td><\/tr>\n<tr><td class=\"num\">128.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for PCP\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/77-10-1\/PCP\" target=\"_blank\" rel=\"noopener\">PCP<\/a><\/td><td class=\"oth\">6.18<\/td><td class=\"oth\">25<\/td><td class=\"oth\">244.2<\/td><td class=\"oth\">86.1<\/td><td class=\"oth\">159.1<\/td><\/tr>\n<tr><td class=\"num\">129.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tenoxicam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59804-37-4\/Tenoxicam\" target=\"_blank\" rel=\"noopener\">Tenoxicam<\/a><\/td><td class=\"oth\">6.18<\/td><td class=\"oth\">25<\/td><td class=\"oth\">338.1<\/td><td class=\"oth\">121.0<\/td><td class=\"oth\">95.0<\/td><\/tr>\n<tr><td class=\"num\">130.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Buspirone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/36505-84-7\/Buspirone\" target=\"_blank\" rel=\"noopener\">Buspirone<\/a><\/td><td class=\"oth\">6.20<\/td><td class=\"oth\">25<\/td><td class=\"oth\">386.3<\/td><td class=\"oth\">122.1<\/td><td class=\"oth\">95.0<\/td><\/tr>\n<tr><td class=\"num\">131.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Quetiapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111974-69-7\/Quetiapine\" target=\"_blank\" rel=\"noopener\">Quetiapine<\/a><\/td><td class=\"oth\">6.28<\/td><td class=\"oth\">25<\/td><td class=\"oth\">384.2<\/td><td class=\"oth\">253.0<\/td><td class=\"oth\">221.2<\/td><\/tr>\n<tr><td class=\"num\">132.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norpropoxyphene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/32501-12-5\/Norpropoxyphene\" target=\"_blank\" rel=\"noopener\">Norpropoxyphene<\/a><\/td><td class=\"oth\">6.29<\/td><td class=\"oth\">25<\/td><td class=\"oth\">326.4<\/td><td class=\"oth\">252.0<\/td><td class=\"oth\">91.1<\/td><\/tr>\n<tr><td class=\"num\">133.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propoxyphene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/469-62-5\/Propoxyphene\" target=\"_blank\" rel=\"noopener\">Propoxyphene<\/a><\/td><td class=\"oth\">6.30<\/td><td class=\"oth\">25<\/td><td class=\"oth\">340.3<\/td><td class=\"oth\">265.9<\/td><td class=\"oth\">58.1<\/td><\/tr>\n<tr><td class=\"num\">134.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Asenapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85650-56-2\/Asenapine\" target=\"_blank\" rel=\"noopener\">Asenapine<\/a><\/td><td class=\"oth\">6.35<\/td><td class=\"oth\">25<\/td><td class=\"oth\">286.2<\/td><td class=\"oth\">165.1<\/td><td class=\"oth\">229.1<\/td><\/tr>\n<tr><td class=\"num\">135.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ziprasidone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/146939-27-7\/Ziprasidone\" target=\"_blank\" rel=\"noopener\">Ziprasidone<\/a><\/td><td class=\"oth\">6.40<\/td><td class=\"oth\">25<\/td><td class=\"oth\">413.2<\/td><td class=\"oth\">194.1<\/td><td class=\"oth\">130.0<\/td><\/tr>\n<tr><td class=\"num\">136.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Protriptyline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/438-60-8\/Protriptyline\" target=\"_blank\" rel=\"noopener\">Protriptyline<\/a><\/td><td class=\"oth\">6.42<\/td><td class=\"oth\">25<\/td><td class=\"oth\">264.1<\/td><td class=\"oth\">191.1<\/td><td class=\"oth\">165.2<\/td><\/tr>\n<tr><td class=\"num\">137.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Promazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/58-40-2\/Promazine\" target=\"_blank\" rel=\"noopener\">Promazine<\/a><\/td><td class=\"oth\">6.42<\/td><td class=\"oth\">25<\/td><td class=\"oth\">285.1<\/td><td class=\"oth\">58.0<\/td><td class=\"oth\">86.0<\/td><\/tr>\n<tr><td class=\"num\">138.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Midazolam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59467-70-8\/Midazolam\" target=\"_blank\" rel=\"noopener\">Midazolam<\/a><\/td><td class=\"oth\">6.43<\/td><td class=\"oth\">25<\/td><td class=\"oth\">326.2<\/td><td class=\"oth\">291.1<\/td><td class=\"oth\">248.9<\/td><\/tr>\n<tr><td class=\"num\">139.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Desipramine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-47-5\/Desipramine\" target=\"_blank\" rel=\"noopener\">Desipramine<\/a><\/td><td class=\"oth\">6.43<\/td><td class=\"oth\">25<\/td><td class=\"oth\">267.1<\/td><td class=\"oth\">72.1<\/td><td class=\"oth\">193.1<\/td><\/tr>\n<tr><td class=\"num\">140.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Amoxapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/14028-44-5\/Amoxapine\" target=\"_blank\" rel=\"noopener\">Amoxapine<\/a><\/td><td class=\"oth\">6.44<\/td><td class=\"oth\">25<\/td><td class=\"oth\">314.2<\/td><td class=\"oth\">271.0<\/td><td class=\"oth\">193.1<\/td><\/tr>\n<tr><td class=\"num\">141.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Sufentanil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56030-54-7\/Sufentanil\" target=\"_blank\" rel=\"noopener\">Sufentanil<\/a><\/td><td class=\"oth\">6.48<\/td><td class=\"oth\">25<\/td><td class=\"oth\">387.2<\/td><td class=\"oth\">238.1<\/td><td class=\"oth\">111.1<\/td><\/tr>\n<tr><td class=\"num\">142.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Imipramine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-49-7\/Imipramine\" target=\"_blank\" rel=\"noopener\">Imipramine<\/a><\/td><td class=\"oth\">6.51<\/td><td class=\"oth\">25<\/td><td class=\"oth\">281.1<\/td><td class=\"oth\">86.2<\/td><td class=\"oth\">58.1<\/td><\/tr>\n<tr><td class=\"num\">143.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Paroxetine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/61869-08-7\/Paroxetine\" target=\"_blank\" rel=\"noopener\">Paroxetine<\/a><\/td><td class=\"oth\">6.51<\/td><td class=\"oth\">25<\/td><td class=\"oth\">330.2<\/td><td class=\"oth\">192.2<\/td><td class=\"oth\">70.1<\/td><\/tr>\n<tr><td class=\"num\">144.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Loxapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1977-10-2\/Loxapine\" target=\"_blank\" rel=\"noopener\">Loxapine<\/a><\/td><td class=\"oth\">6.52<\/td><td class=\"oth\">25<\/td><td class=\"oth\">328.1<\/td><td class=\"oth\">271.1<\/td><td class=\"oth\">193.0<\/td><\/tr>\n<tr><td class=\"num\">145.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Maprotiline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/10262-69-8\/Maprotiline\" target=\"_blank\" rel=\"noopener\">Maprotiline<\/a><\/td><td class=\"oth\">6.52<\/td><td class=\"oth\">25<\/td><td class=\"oth\">278.1<\/td><td class=\"oth\">250.2<\/td><td class=\"oth\">191.0<\/td><\/tr>\n<tr><td class=\"num\">146.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Duloxetine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/136434-34-9\/Duloxetine\" target=\"_blank\" rel=\"noopener\">Duloxetine<\/a><\/td><td class=\"oth\">6.52<\/td><td class=\"oth\">25<\/td><td class=\"oth\">298.1<\/td><td class=\"oth\">154.1<\/td><td class=\"oth\">188.2<\/td><\/tr>\n<tr><td class=\"num\">147.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Metaxalone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1665-48-1\/Metaxalone\" target=\"_blank\" rel=\"noopener\">Metaxalone<\/a><\/td><td class=\"oth\">6.52<\/td><td class=\"oth\">25<\/td><td class=\"oth\">222.1<\/td><td class=\"oth\">161.1<\/td><td class=\"oth\">77.1<\/td><\/tr>\n<tr><td class=\"num\">148.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carbamazepine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-46-4\/Carbamazepine\" target=\"_blank\" rel=\"noopener\">Carbamazepine<\/a><\/td><td class=\"oth\">6.55<\/td><td class=\"oth\">10<\/td><td class=\"oth\">237.1<\/td><td class=\"oth\">194.1<\/td><td class=\"oth\">165.0<\/td><\/tr>\n<tr><td class=\"num\">149.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cyclobenzaprine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/303-53-7\/Cyclobenzaprine\" target=\"_blank\" rel=\"noopener\">Cyclobenzaprine<\/a><\/td><td class=\"oth\">6.56<\/td><td class=\"oth\">25<\/td><td class=\"oth\">276.2<\/td><td class=\"oth\">215.0<\/td><td class=\"oth\">189.0<\/td><\/tr>\n<tr><td class=\"num\">150.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for EDDP\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/30223-73-5\/EDDP\" target=\"_blank\" rel=\"noopener\">EDDP<\/a><\/td><td class=\"oth\">6.57<\/td><td class=\"oth\">25<\/td><td class=\"oth\">278.2<\/td><td class=\"oth\">234.3<\/td><td class=\"oth\">249.2<\/td><\/tr>\n<tr><td class=\"num\">151.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nortriptyline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72-69-5\/Nortriptyline\" target=\"_blank\" rel=\"noopener\">Nortriptyline<\/a><\/td><td class=\"oth\">6.58<\/td><td class=\"oth\">25<\/td><td class=\"oth\">264.1<\/td><td class=\"oth\">91.1<\/td><td class=\"oth\">115.2<\/td><\/tr>\n<tr><td class=\"num\">152.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mitragynine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4098-40-2\/Mitragynine\" target=\"_blank\" rel=\"noopener\">Mitragynine<\/a><\/td><td class=\"oth\">6.59<\/td><td class=\"oth\">25<\/td><td class=\"oth\">399.3<\/td><td class=\"oth\">174.2<\/td><td class=\"oth\">159.0<\/td><\/tr>\n<tr><td class=\"num\">153.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Eslicarbazepine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/236395-14-5\/Eslicarbazepine\" target=\"_blank\" rel=\"noopener\">Eslicarbazepine<\/a><\/td><td class=\"oth\">6.60<\/td><td class=\"oth\">25<\/td><td class=\"oth\">297.2<\/td><td class=\"oth\">194.0<\/td><td class=\"oth\">237.1<\/td><\/tr>\n<tr><td class=\"num\">154.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Amitriptyline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-48-6\/Amitriptyline\" target=\"_blank\" rel=\"noopener\">Amitriptyline<\/a><\/td><td class=\"oth\">6.65<\/td><td class=\"oth\">25<\/td><td class=\"oth\">278.1<\/td><td class=\"oth\">91.1<\/td><td class=\"oth\">202.1<\/td><\/tr>\n<tr><td class=\"num\">155.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Hydroxymidazolam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59468-90-5\/\u03b1-Hydroxymidazolam\" target=\"_blank\" rel=\"noopener\">\u03b1-Hydroxymidazolam<\/a><\/td><td class=\"oth\">6.70<\/td><td class=\"oth\">25<\/td><td class=\"oth\">342.2<\/td><td class=\"oth\">324.1<\/td><td class=\"oth\">202.9<\/td><\/tr>\n<tr><td class=\"num\">156.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Trimipramine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/739-71-9\/Trimipramine\" target=\"_blank\" rel=\"noopener\">Trimipramine<\/a><\/td><td class=\"oth\">6.75<\/td><td class=\"oth\">25<\/td><td class=\"oth\">295.2<\/td><td class=\"oth\">100.2<\/td><td class=\"oth\">58.2<\/td><\/tr>\n<tr><td class=\"num\">157.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Desmethylflunitrazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2558-30-7\/N-Desmethylflunitrazepam\" target=\"_blank\" rel=\"noopener\">N-Desmethylflunitrazepam<\/a><\/td><td class=\"oth\">6.80<\/td><td class=\"oth\">25<\/td><td class=\"oth\">300.1<\/td><td class=\"oth\">254.1<\/td><td class=\"oth\">198.1<\/td><\/tr>\n<tr><td class=\"num\">158.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Lorazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/846-49-1\/Lorazepam\" target=\"_blank\" rel=\"noopener\">Lorazepam<\/a><\/td><td class=\"oth\">6.82<\/td><td class=\"oth\">25<\/td><td class=\"oth\">321.1<\/td><td class=\"oth\">275.0<\/td><td class=\"oth\">229.0<\/td><\/tr>\n<tr><td class=\"num\">159.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mesoridazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5588-33-0\/Mesoridazine\" target=\"_blank\" rel=\"noopener\">Mesoridazine<\/a><\/td><td class=\"oth\">6.83<\/td><td class=\"oth\">25<\/td><td class=\"oth\">387.2<\/td><td class=\"oth\">126.1<\/td><td class=\"oth\">98.2<\/td><\/tr>\n<tr><td class=\"num\">160.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tiagabine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/115103-54-3\/Tiagabine\" target=\"_blank\" rel=\"noopener\">Tiagabine<\/a><\/td><td class=\"oth\">6.89<\/td><td class=\"oth\">25<\/td><td class=\"oth\">376.2<\/td><td class=\"oth\">246.8<\/td><td class=\"oth\">111.1<\/td><\/tr>\n<tr><td class=\"num\">161.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ketorolac\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/74103-06-3\/Ketorolac\" target=\"_blank\" rel=\"noopener\">Ketorolac<\/a><\/td><td class=\"oth\">6.90<\/td><td class=\"oth\">25<\/td><td class=\"oth\">256.1<\/td><td class=\"oth\">104.9<\/td><td class=\"oth\">77.0<\/td><\/tr>\n<tr><td class=\"num\">162.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorpromazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-53-3\/Chlorpromazine\" target=\"_blank\" rel=\"noopener\">Chlorpromazine<\/a><\/td><td class=\"oth\">6.91<\/td><td class=\"oth\">25<\/td><td class=\"oth\">320.1<\/td><td class=\"oth\">58.1<\/td><td class=\"oth\">86.1<\/td><\/tr>\n<tr><td class=\"num\">163.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Loxoprofen*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68767-14-6\/Loxoprofen\" target=\"_blank\" rel=\"noopener\">Loxoprofen*<\/a><\/td><td class=\"oth\">6.93<\/td><td class=\"oth\">200<\/td><td class=\"oth\">245.0<\/td><td class=\"oth\">83.2<\/td><td class=\"oth\">80.9<\/td><\/tr>\n<tr><td class=\"num\">164.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Clomipramine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/303-49-1\/Clomipramine\" target=\"_blank\" rel=\"noopener\">Clomipramine<\/a><\/td><td class=\"oth\">6.95<\/td><td class=\"oth\">25<\/td><td class=\"oth\">315.3<\/td><td class=\"oth\">86.0<\/td><td class=\"oth\">58.0<\/td><\/tr>\n<tr><td class=\"num\">165.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/604-75-1\/Oxazepam\" target=\"_blank\" rel=\"noopener\">Oxazepam<\/a><\/td><td class=\"oth\">6.96<\/td><td class=\"oth\">25<\/td><td class=\"oth\">287.1<\/td><td class=\"oth\">241.2<\/td><td class=\"oth\">268.8<\/td><\/tr>\n<tr><td class=\"num\">166.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methadone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-99-3\/Methadone\" target=\"_blank\" rel=\"noopener\">Methadone<\/a><\/td><td class=\"oth\">6.98<\/td><td class=\"oth\">25<\/td><td class=\"oth\">310.2<\/td><td class=\"oth\">264.9<\/td><td class=\"oth\">105.1<\/td><\/tr>\n<tr><td class=\"num\">167.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Sertraline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/79617-96-2\/Sertraline\" target=\"_blank\" rel=\"noopener\">Sertraline<\/a><\/td><td class=\"oth\">6.98<\/td><td class=\"oth\">25<\/td><td class=\"oth\">306.2<\/td><td class=\"oth\">158.9<\/td><td class=\"oth\">275.1<\/td><\/tr>\n<tr><td class=\"num\">168.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dehydro aripiprazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/129722-25-4\/Dehydro aripiprazole\" target=\"_blank\" rel=\"noopener\">Dehydro aripiprazole<\/a><\/td><td class=\"oth\">7.01<\/td><td class=\"oth\">25<\/td><td class=\"oth\">446.2<\/td><td class=\"oth\">285.0<\/td><td class=\"oth\">98.1<\/td><\/tr>\n<tr><td class=\"num\">169.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Clonazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1622-61-3\/Clonazepam\" target=\"_blank\" rel=\"noopener\">Clonazepam<\/a><\/td><td class=\"oth\">7.01<\/td><td class=\"oth\">25<\/td><td class=\"oth\">316.1<\/td><td class=\"oth\">270.0<\/td><td class=\"oth\">214.1<\/td><\/tr>\n<tr><td class=\"num\">170.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nitrazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/146-22-5\/Nitrazepam\" target=\"_blank\" rel=\"noopener\">Nitrazepam<\/a><\/td><td class=\"oth\">7.01<\/td><td class=\"oth\">25<\/td><td class=\"oth\">282.1<\/td><td class=\"oth\">235.9<\/td><td class=\"oth\">180.1<\/td><\/tr>\n<tr><td class=\"num\">171.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Lornoxicam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/70374-39-9\/Lornoxicam\" target=\"_blank\" rel=\"noopener\">Lornoxicam<\/a><\/td><td class=\"oth\">7.02<\/td><td class=\"oth\">100<\/td><td class=\"oth\">373.1<\/td><td class=\"oth\">121.1<\/td><td class=\"oth\">95.0<\/td><\/tr>\n<tr><td class=\"num\">172.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 25I-NBOMe\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/919797-19-6\/25I-NBOMe\" target=\"_blank\" rel=\"noopener\">25I-NBOMe<\/a><\/td><td class=\"oth\">7.05<\/td><td class=\"oth\">25<\/td><td class=\"oth\">428.1<\/td><td class=\"oth\">121.2<\/td><td class=\"oth\">91.1<\/td><\/tr>\n<tr><td class=\"num\">173.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Salsalate*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/552-94-3\/Salsalate\" target=\"_blank\" rel=\"noopener\">Salsalate*<\/a><\/td><td class=\"oth\">7.05<\/td><td class=\"oth\">100<\/td><td class=\"oth\">256.8<\/td><td class=\"oth\">136.8<\/td><td class=\"oth\">92.9<\/td><\/tr>\n<tr><td class=\"num\">174.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Desalkylflurazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2886-65-9\/Desalkylflurazepam\" target=\"_blank\" rel=\"noopener\">Desalkylflurazepam<\/a><\/td><td class=\"oth\">7.09<\/td><td class=\"oth\">25<\/td><td class=\"oth\">289.0<\/td><td class=\"oth\">140.1<\/td><td class=\"oth\">104.0<\/td><\/tr>\n<tr><td class=\"num\">175.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tolmetin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/26171-23-3\/Tolmetin\" target=\"_blank\" rel=\"noopener\">Tolmetin<\/a><\/td><td class=\"oth\">7.10<\/td><td class=\"oth\">25<\/td><td class=\"oth\">258.1<\/td><td class=\"oth\">119.1<\/td><td class=\"oth\">91.0<\/td><\/tr>\n<tr><td class=\"num\">176.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Hydroxytriazolam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/37115-45-0\/\u03b1-Hydroxytriazolam\" target=\"_blank\" rel=\"noopener\">\u03b1-Hydroxytriazolam<\/a><\/td><td class=\"oth\">7.12<\/td><td class=\"oth\">25<\/td><td class=\"oth\">359.1<\/td><td class=\"oth\">330.9<\/td><td class=\"oth\">175.9<\/td><\/tr>\n<tr><td class=\"num\">177.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluphenazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/69-23-8\/Fluphenazine\" target=\"_blank\" rel=\"noopener\">Fluphenazine<\/a><\/td><td class=\"oth\">7.16<\/td><td class=\"oth\">25<\/td><td class=\"oth\">438.3<\/td><td class=\"oth\">171.1<\/td><td class=\"oth\">143.2<\/td><\/tr>\n<tr><td class=\"num\">178.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Hydroxyethylflurazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/20971-53-3\/2-Hydroxyethylflurazepam\" target=\"_blank\" rel=\"noopener\">2-Hydroxyethylflurazepam<\/a><\/td><td class=\"oth\">7.16<\/td><td class=\"oth\">25<\/td><td class=\"oth\">333.1<\/td><td class=\"oth\">211.1<\/td><td class=\"oth\">109.0<\/td><\/tr>\n<tr><td class=\"num\">179.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ketoprofen*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/22071-15-4\/Ketoprofen\" target=\"_blank\" rel=\"noopener\">Ketoprofen*<\/a><\/td><td class=\"oth\">7.17<\/td><td class=\"oth\">100<\/td><td class=\"oth\">253.0<\/td><td class=\"oth\">209.0<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">180.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Naproxen*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/22204-53-1\/Naproxen\" target=\"_blank\" rel=\"noopener\">Naproxen*<\/a><\/td><td class=\"oth\">7.17<\/td><td class=\"oth\">200<\/td><td class=\"oth\">229.0<\/td><td class=\"oth\">168.9<\/td><td class=\"oth\">184.9<\/td><\/tr>\n<tr><td class=\"num\">181.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for EMDP\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/102177-18-4\/EMDP\" target=\"_blank\" rel=\"noopener\">EMDP<\/a><\/td><td class=\"oth\">7.19<\/td><td class=\"oth\">25<\/td><td class=\"oth\">264.2<\/td><td class=\"oth\">235.2<\/td><td class=\"oth\">220.3<\/td><\/tr>\n<tr><td class=\"num\">182.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aripiprazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/129722-12-9\/Aripiprazole\" target=\"_blank\" rel=\"noopener\">Aripiprazole<\/a><\/td><td class=\"oth\">7.20<\/td><td class=\"oth\">25<\/td><td class=\"oth\">448.2<\/td><td class=\"oth\">285.0<\/td><td class=\"oth\">176.1<\/td><\/tr>\n<tr><td class=\"num\">183.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perphenazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/58-39-9\/Perphenazine\" target=\"_blank\" rel=\"noopener\">Perphenazine<\/a><\/td><td class=\"oth\">7.22<\/td><td class=\"oth\">25<\/td><td class=\"oth\">404.2<\/td><td class=\"oth\">171.1<\/td><td class=\"oth\">143.2<\/td><\/tr>\n<tr><td class=\"num\">184.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Etoricoxib\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/202409-33-4\/Etoricoxib\" target=\"_blank\" rel=\"noopener\">Etoricoxib<\/a><\/td><td class=\"oth\">7.24<\/td><td class=\"oth\">25<\/td><td class=\"oth\">359.2<\/td><td class=\"oth\">280.0<\/td><td class=\"oth\">279.2<\/td><\/tr>\n<tr><td class=\"num\">185.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methaqualone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72-44-6\/Methaqualone\" target=\"_blank\" rel=\"noopener\">Methaqualone<\/a><\/td><td class=\"oth\">7.24<\/td><td class=\"oth\">25<\/td><td class=\"oth\">251.1<\/td><td class=\"oth\">91.1<\/td><td class=\"oth\">132.2<\/td><\/tr>\n<tr><td class=\"num\">186.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Hydroxyalprazolam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/37115-43-8\/\u03b1-Hydroxyalprazolam\" target=\"_blank\" rel=\"noopener\">\u03b1-Hydroxyalprazolam<\/a><\/td><td class=\"oth\">7.25<\/td><td class=\"oth\">25<\/td><td class=\"oth\">325.1<\/td><td class=\"oth\">297.0<\/td><td class=\"oth\">216.2<\/td><\/tr>\n<tr><td class=\"num\">187.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Trifluoperazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/117-89-5\/Trifluoperazine\" target=\"_blank\" rel=\"noopener\">Trifluoperazine<\/a><\/td><td class=\"oth\">7.28<\/td><td class=\"oth\">25<\/td><td class=\"oth\">408.2<\/td><td class=\"oth\">141.2<\/td><td class=\"oth\">113.1<\/td><\/tr>\n<tr><td class=\"num\">188.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Piroxicam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/36322-90-4\/Piroxicam\" target=\"_blank\" rel=\"noopener\">Piroxicam<\/a><\/td><td class=\"oth\">7.34<\/td><td class=\"oth\">25<\/td><td class=\"oth\">332.1<\/td><td class=\"oth\">95.2<\/td><td class=\"oth\">78.1<\/td><\/tr>\n<tr><td class=\"num\">189.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ibuprofen*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/15687-27-1\/Ibuprofen\" target=\"_blank\" rel=\"noopener\">Ibuprofen*<\/a><\/td><td class=\"oth\">7.34<\/td><td class=\"oth\">200<\/td><td class=\"oth\">205.0<\/td><td class=\"oth\">160.9<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">190.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Prochlorperazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/58-38-8\/Prochlorperazine\" target=\"_blank\" rel=\"noopener\">Prochlorperazine<\/a><\/td><td class=\"oth\">7.36<\/td><td class=\"oth\">25<\/td><td class=\"oth\">374.1<\/td><td class=\"oth\">141.0<\/td><td class=\"oth\">113.1<\/td><\/tr>\n<tr><td class=\"num\">191.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Etodolac*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/41340-25-4\/Etodolac\" target=\"_blank\" rel=\"noopener\">Etodolac*<\/a><\/td><td class=\"oth\">7.36<\/td><td class=\"oth\">50<\/td><td class=\"oth\">286.0<\/td><td class=\"oth\">241.9<\/td><td class=\"oth\">212.0<\/td><\/tr>\n<tr><td class=\"num\">192.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nordiazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1088-11-5\/Nordiazepam\" target=\"_blank\" rel=\"noopener\">Nordiazepam<\/a><\/td><td class=\"oth\">7.37<\/td><td class=\"oth\">25<\/td><td class=\"oth\">271.0<\/td><td class=\"oth\">139.9<\/td><td class=\"oth\">208.0<\/td><\/tr>\n<tr><td class=\"num\">193.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51753-57-2\/Phenazepam\" target=\"_blank\" rel=\"noopener\">Phenazepam<\/a><\/td><td class=\"oth\">7.39<\/td><td class=\"oth\">25<\/td><td class=\"oth\">349.1<\/td><td class=\"oth\">206.2<\/td><td class=\"oth\">179.0<\/td><\/tr>\n<tr><td class=\"num\">194.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenoprofen*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/29679-58-1\/Fenoprofen\" target=\"_blank\" rel=\"noopener\">Fenoprofen*<\/a><\/td><td class=\"oth\">7.40<\/td><td class=\"oth\">200<\/td><td class=\"oth\">240.9<\/td><td class=\"oth\">92.8<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">195.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Zaleplon\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/151319-34-5\/Zaleplon\" target=\"_blank\" rel=\"noopener\">Zaleplon<\/a><\/td><td class=\"oth\">7.43<\/td><td class=\"oth\">25<\/td><td class=\"oth\">306.1<\/td><td class=\"oth\">264.0<\/td><td class=\"oth\">236.0<\/td><\/tr>\n<tr><td class=\"num\">196.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Clobazam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/22316-47-8\/Clobazam\" target=\"_blank\" rel=\"noopener\">Clobazam<\/a><\/td><td class=\"oth\">7.43<\/td><td class=\"oth\">25<\/td><td class=\"oth\">301.0<\/td><td class=\"oth\">259.1<\/td><td class=\"oth\">224.0<\/td><\/tr>\n<tr><td class=\"num\">197.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flurbiprofen*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5104-49-4\/Flurbiprofen\" target=\"_blank\" rel=\"noopener\">Flurbiprofen*<\/a><\/td><td class=\"oth\">7.48<\/td><td class=\"oth\">200<\/td><td class=\"oth\">243.0<\/td><td class=\"oth\">199.0<\/td><td class=\"oth\">196.8<\/td><\/tr>\n<tr><td class=\"num\">198.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Thiothixene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5591-45-7\/Thiothixene\" target=\"_blank\" rel=\"noopener\">Thiothixene<\/a><\/td><td class=\"oth\">7.50<\/td><td class=\"oth\">25<\/td><td class=\"oth\">444.2<\/td><td class=\"oth\">221.2<\/td><td class=\"oth\">235.0<\/td><\/tr>\n<tr><td class=\"num\">199.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flunitrazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1622-62-4\/Flunitrazepam\" target=\"_blank\" rel=\"noopener\">Flunitrazepam<\/a><\/td><td class=\"oth\">7.55<\/td><td class=\"oth\">25<\/td><td class=\"oth\">314.2<\/td><td class=\"oth\">267.9<\/td><td class=\"oth\">239.1<\/td><\/tr>\n<tr><td class=\"num\">200.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Meloxicam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/71125-38-7\/Meloxicam\" target=\"_blank\" rel=\"noopener\">Meloxicam<\/a><\/td><td class=\"oth\">7.55<\/td><td class=\"oth\">25<\/td><td class=\"oth\">352.1<\/td><td class=\"oth\">115.0<\/td><td class=\"oth\">141.0<\/td><\/tr>\n<tr><td class=\"num\">201.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Triazolam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/28911-01-5\/Triazolam\" target=\"_blank\" rel=\"noopener\">Triazolam<\/a><\/td><td class=\"oth\">7.58<\/td><td class=\"oth\">25<\/td><td class=\"oth\">343.1<\/td><td class=\"oth\">307.9<\/td><td class=\"oth\">315.0<\/td><\/tr>\n<tr><td class=\"num\">202.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Estazolam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/29975-16-4\/Estazolam\" target=\"_blank\" rel=\"noopener\">Estazolam<\/a><\/td><td class=\"oth\">7.58<\/td><td class=\"oth\">25<\/td><td class=\"oth\">295.1<\/td><td class=\"oth\">266.9<\/td><td class=\"oth\">205.1<\/td><\/tr>\n<tr><td class=\"num\">203.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Celecoxib\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/169590-42-5\/Celecoxib\" target=\"_blank\" rel=\"noopener\">Celecoxib<\/a><\/td><td class=\"oth\">7.60<\/td><td class=\"oth\">25<\/td><td class=\"oth\">382.2<\/td><td class=\"oth\">362.0<\/td><td class=\"oth\">300.1<\/td><\/tr>\n<tr><td class=\"num\">204.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Parecoxib\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/198470-84-7\/Parecoxib\" target=\"_blank\" rel=\"noopener\">Parecoxib<\/a><\/td><td class=\"oth\">7.60<\/td><td class=\"oth\">25<\/td><td class=\"oth\">371.2<\/td><td class=\"oth\">234.0<\/td><td class=\"oth\">165.1<\/td><\/tr>\n<tr><td class=\"num\">205.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Temazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/846-50-4\/Temazepam\" target=\"_blank\" rel=\"noopener\">Temazepam<\/a><\/td><td class=\"oth\">7.61<\/td><td class=\"oth\">25<\/td><td class=\"oth\">301.1<\/td><td class=\"oth\">255.1<\/td><td class=\"oth\">282.9<\/td><\/tr>\n<tr><td class=\"num\">206.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Sulindac\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/38194-50-2\/Sulindac\" target=\"_blank\" rel=\"noopener\">Sulindac<\/a><\/td><td class=\"oth\">7.70<\/td><td class=\"oth\">25<\/td><td class=\"oth\">357.2<\/td><td class=\"oth\">233.1<\/td><td class=\"oth\">248.0<\/td><\/tr>\n<tr><td class=\"num\">207.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Alprazolam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/28981-97-7\/Alprazolam\" target=\"_blank\" rel=\"noopener\">Alprazolam<\/a><\/td><td class=\"oth\">7.72<\/td><td class=\"oth\">25<\/td><td class=\"oth\">309.1<\/td><td class=\"oth\">280.9<\/td><td class=\"oth\">204.9<\/td><\/tr>\n<tr><td class=\"num\">208.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flufenamic acid*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/530-78-9\/Flufenamic acid\" target=\"_blank\" rel=\"noopener\">Flufenamic acid*<\/a><\/td><td class=\"oth\">7.75<\/td><td class=\"oth\">50<\/td><td class=\"oth\">279.9<\/td><td class=\"oth\">236.1<\/td><td class=\"oth\">176.2<\/td><\/tr>\n<tr><td class=\"num\">209.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Thioridazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-52-2\/Thioridazine\" target=\"_blank\" rel=\"noopener\">Thioridazine<\/a><\/td><td class=\"oth\">7.76<\/td><td class=\"oth\">25<\/td><td class=\"oth\">371.2<\/td><td class=\"oth\">126.1<\/td><td class=\"oth\">98.1<\/td><\/tr>\n<tr><td class=\"num\">210.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diclofenac*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/15307-86-5\/Diclofenac\" target=\"_blank\" rel=\"noopener\">Diclofenac*<\/a><\/td><td class=\"oth\">7.78<\/td><td class=\"oth\">100<\/td><td class=\"oth\">293.9<\/td><td class=\"oth\">249.8<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">211.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nabumetone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/42924-53-8\/Nabumetone\" target=\"_blank\" rel=\"noopener\">Nabumetone<\/a><\/td><td class=\"oth\">7.80<\/td><td class=\"oth\">25<\/td><td class=\"oth\">229.1<\/td><td class=\"oth\">171.1<\/td><td class=\"oth\">128.1<\/td><\/tr>\n<tr><td class=\"num\">212.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxaprozin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/21256-18-8\/Oxaprozin\" target=\"_blank\" rel=\"noopener\">Oxaprozin<\/a><\/td><td class=\"oth\">7.87<\/td><td class=\"oth\">25<\/td><td class=\"oth\">294.1<\/td><td class=\"oth\">103.0<\/td><td class=\"oth\">234.2<\/td><\/tr>\n<tr><td class=\"num\">213.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for HU-211\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/112924-45-5\/HU-211\" target=\"_blank\" rel=\"noopener\">HU-211<\/a><\/td><td class=\"oth\">8.03<\/td><td class=\"oth\">25<\/td><td class=\"oth\">387.3<\/td><td class=\"oth\">155.9<\/td><td class=\"oth\">128.1<\/td><\/tr>\n<tr><td class=\"num\">214.<\/td><td class=\"cmpd\">JWH\u2010200<\/td><td class=\"oth\">8.04<\/td><td class=\"oth\">25<\/td><td class=\"oth\">385.3<\/td><td class=\"oth\">155.0<\/td><td class=\"oth\">127.1<\/td><\/tr>\n<tr><td class=\"num\">215.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/439-14-5\/Diazepam\" target=\"_blank\" rel=\"noopener\">Diazepam<\/a><\/td><td class=\"oth\">8.04<\/td><td class=\"oth\">25<\/td><td class=\"oth\">285.1<\/td><td class=\"oth\">192.9<\/td><td class=\"oth\">153.9<\/td><\/tr>\n<tr><td class=\"num\">216.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mefenamic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/61-68-7\/Mefenamic acid\" target=\"_blank\" rel=\"noopener\">Mefenamic acid<\/a><\/td><td class=\"oth\">8.04<\/td><td class=\"oth\">25<\/td><td class=\"oth\">242.1<\/td><td class=\"oth\">224.1<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">217.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tolfenamic acid*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13710-19-5\/Tolfenamic acid\" target=\"_blank\" rel=\"noopener\">Tolfenamic acid*<\/a><\/td><td class=\"oth\">8.17<\/td><td class=\"oth\">50<\/td><td class=\"oth\">259.9<\/td><td class=\"oth\">215.8<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">218.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Meclofenamic acid*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/644-62-2\/Meclofenamic acid\" target=\"_blank\" rel=\"noopener\">Meclofenamic acid*<\/a><\/td><td class=\"oth\">8.18<\/td><td class=\"oth\">200<\/td><td class=\"oth\">293.9<\/td><td class=\"oth\">257.8<\/td><td class=\"oth\">177.7<\/td><\/tr>\n<tr><td class=\"num\">219.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (+\/-)-CP 47,497*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/70434-82-1\/(+_-)-CP 47,497\" target=\"_blank\" rel=\"noopener\">(+\/-)-CP 47,497*<\/a><\/td><td class=\"oth\">8.27<\/td><td class=\"oth\">200<\/td><td class=\"oth\">317.1<\/td><td class=\"oth\">245.1<\/td><td class=\"oth\">159.0<\/td><\/tr>\n<tr><td class=\"num\">220.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Indomethacin*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53-86-1\/Indomethacin\" target=\"_blank\" rel=\"noopener\">Indomethacin*<\/a><\/td><td class=\"oth\">8.29<\/td><td class=\"oth\">50<\/td><td class=\"oth\">356.0<\/td><td class=\"oth\">311.8<\/td><td class=\"oth\">296.9<\/td><\/tr>\n<tr><td class=\"num\">221.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perampanel\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/380917-97-5\/Perampanel\" target=\"_blank\" rel=\"noopener\">Perampanel<\/a><\/td><td class=\"oth\">8.32<\/td><td class=\"oth\">25<\/td><td class=\"oth\">350.2<\/td><td class=\"oth\">219.1<\/td><td class=\"oth\">247.1<\/td><\/tr>\n<tr><td class=\"num\">222.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (+\/-)-CP 47,497 C8 homologue*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/70434-92-3\/(+_-)-CP 47,497 C8 homologue\" target=\"_blank\" rel=\"noopener\">(+\/-)-CP 47,497 C8 homologue*<\/a><\/td><td class=\"oth\">8.42<\/td><td class=\"oth\">200<\/td><td class=\"oth\">331.1<\/td><td class=\"oth\">259.0<\/td><td class=\"oth\">159.1<\/td><\/tr>\n<tr><td class=\"num\">223.<\/td><td class=\"cmpd\">11-Nor-9-carboxy-delta-9-THC*<\/td><td class=\"oth\">8.44<\/td><td class=\"oth\">25<\/td><td class=\"oth\">343.0<\/td><td class=\"oth\">298.9<\/td><td class=\"oth\">244.8<\/td><\/tr>\n<tr><td class=\"num\">224.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Prazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2955-38-6\/Prazepam\" target=\"_blank\" rel=\"noopener\">Prazepam<\/a><\/td><td class=\"oth\">8.51<\/td><td class=\"oth\">25<\/td><td class=\"oth\">325.2<\/td><td class=\"oth\">271.0<\/td><td class=\"oth\">139.9<\/td><\/tr>\n<tr><td class=\"num\">225.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for XLR-11\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1364933-54-9\/XLR-11\" target=\"_blank\" rel=\"noopener\">XLR-11<\/a><\/td><td class=\"oth\">8.60<\/td><td class=\"oth\">25<\/td><td class=\"oth\">330.3<\/td><td class=\"oth\">125.2<\/td><td class=\"oth\">144.0<\/td><\/tr>\n<tr><td class=\"num\">226.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03949-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1972-08-3\/\u03949-THC\" target=\"_blank\" rel=\"noopener\">\u03949-THC<\/a><\/td><td class=\"oth\">8.76<\/td><td class=\"oth\">25<\/td><td class=\"oth\">315.2<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.2<\/td><\/tr>\n<tr><td class=\"num\">227.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for UR-144\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1199943-44-6\/UR-144\" target=\"_blank\" rel=\"noopener\">UR-144<\/a><\/td><td class=\"oth\">8.78<\/td><td class=\"oth\">25<\/td><td class=\"oth\">312.3<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">214.1<\/td><\/tr>\n<tr><td class=\"num\">228.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for JWH-250\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/864445-43-2\/JWH-250\" target=\"_blank\" rel=\"noopener\">JWH-250<\/a><\/td><td class=\"oth\">8.96<\/td><td class=\"oth\">25<\/td><td class=\"oth\">336.3<\/td><td class=\"oth\">120.9<\/td><td class=\"oth\">91.1<\/td><\/tr>\n<tr><td class=\"num\">229.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for THCA-A*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23978-85-0\/THCA-A\" target=\"_blank\" rel=\"noopener\">THCA-A*<\/a><\/td><td class=\"oth\">9.12<\/td><td class=\"oth\">25<\/td><td class=\"oth\">357.1<\/td><td class=\"oth\">312.9<\/td><td class=\"oth\">245.0<\/td><\/tr>\n<tr><td class=\"num\">230.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for JWH-073\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/208897-48-8\/JWH-073\" target=\"_blank\" rel=\"noopener\">JWH-073<\/a><\/td><td class=\"oth\">9.21<\/td><td class=\"oth\">25<\/td><td class=\"oth\">328.2<\/td><td class=\"oth\">155.0<\/td><td class=\"oth\">127.1<\/td><\/tr>\n<tr><td class=\"num\">231.<\/td><td class=\"cmpd\">JWH\u2010018<\/td><td class=\"oth\">9.35<\/td><td class=\"oth\">25<\/td><td class=\"oth\">342.3<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">155.1<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">*Analyzed using negative polarity.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor Biphenyl  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9309A12\" rel=\"noopener\">cat.# 9309A12<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Raptor Biphenyl EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9309A0252\" rel=\"noopener\">cat.# 9309A0252<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>30 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Water<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water + 0.1% formic acid + 2 mM ammonium formate <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td> Methanol + 0.1% formic acid + 2 mM ammonium formate <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.6<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>9.00<\/td><td>0.6<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>10.00<\/td><td>0.6<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>10.01<\/td><td>0.6<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>12.00<\/td><td>0.6<\/td><td>95<\/td><td>5<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+\/ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>Scheduled MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>UHPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>1. Positive and negative polarity data were collected simultaneously from a single injection. <br \/>2. Ibuprofen, fosphenytoin, and topiramate degrade quickly in solution.<br \/>3. Levorphanol and dextrorphan are enantiomers and are not resolved.<br \/>4. Escitalopram is a pure enantiomer and citalopram is a racemic mixture of both enantiomers.  These compounds are not resolved.<br \/>5. DMAA consists of 4 stereoisomers, 2 of which are partially resolved.<br \/>6. Doxepin and desmethylydoxepin consist of a mixture of <i>cis\/trans<\/i> isomers.  The isomers are fully resolved and the retention time identifies the main isomer component.<br \/>7. Lornoxicam, meloxicam, etodolac, oxaprozin, indomethacin, and mefenamic acid can be detected by positive or negative polarity.  The polarity chosen in this chromatogram provides optimal response.<br \/><\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A0252<\/li><li>9309A12<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0621.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Come \u00e8 mostrato in questa analisi, la colonna Raptor bifenilica di Restek \u00e8 ideale per sviluppare metodologie LC-MS\/MS efficaci per lo screening degli antidolorifici. Grazie alla ritenzione estremamente elevata e alla selettivit\u00e0 unica \u00e8 possibile analizzare in soli 10 minuti 231 composti di farmaci multiclasse e metaboliti, tra cui oltre 40 isobari.<\/p>\n","protected":false},"author":11,"featured_media":70277,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[788],"tags":[],"industries-application":[2245,2248],"post-badge":[],"resource-type":[2768],"product-library":[2535,2517],"resource-technique":[2334,2334,2364],"ppma_author":[414],"class_list":["post-43379","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articoli","industries-application-clinico","industries-application-tossicologia-clinica","resource-type-featured-application","product-library-colonne-lc","product-library-prodotti-per-cromatografia-liquida","resource-technique-cromatografia-liquida-lc","resource-technique-ms-ms-it"],"acf":[],"taxonomy_info":{"category":[{"value":788,"label":"Articoli"}],"industries-application":[{"value":2245,"label":"Clinico"},{"value":2248,"label":"Tossicologia Clinica"}],"resource-type":[{"value":2768,"label":"Featured Application"}],"product-library":[{"value":2535,"label":"Colonne LC"},{"value":2517,"label":"Prodotti per Cromatografia Liquida"}],"resource-technique":[{"value":2334,"label":"Cromatografia Liquida (LC)"},{"value":2334,"label":"Cromatografia Liquida (LC)"},{"value":2364,"label":"MS\/MS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-CFSS2310-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/it\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":788,"name":"Articoli","slug":"articoli","term_group":0,"term_taxonomy_id":788,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":788,"category_count":511,"category_description":"","cat_name":"Articoli","category_nicename":"articoli","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43379","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=43379"}],"version-history":[{"count":1,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43379\/revisions"}],"predecessor-version":[{"id":68503,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43379\/revisions\/68503"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media\/70277"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=43379"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=43379"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=43379"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=43379"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=43379"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=43379"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=43379"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=43379"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=43379"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}