{"id":43592,"date":"2023-10-24T00:00:00","date_gmt":"2023-10-24T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/overcome-the-frustrations-of-residual-solvent-gases-testing-with-resteks-exceptionally-reliable-standards\/"},"modified":"2026-09-11T19:51:42","modified_gmt":"2026-09-11T19:51:42","slug":"overcome-the-frustrations-of-residual-solvent-gases-testing-with-resteks-exceptionally-reliable-standards","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/articles\/ffss4116\/overcome-the-frustrations-of-residual-solvent-gases-testing-with-resteks-exceptionally-reliable-standards","title":{"rendered":"Overcome the Frustrations of Residual Solvent Gases Testing with Restek\u2019s Exceptionally Reliable Standards"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Our Restek Team has gone above and beyond to produce the best quality residual solvent gases standards across the cannabis testing industry. We\u2019ve taken measures to overcome common pain points in testing, ensured consistent lot-to-lot and ampul-to-ampul reproducibility, and created supportive resources for best practices in handling. Our four-component residual solvent gases standard mix contains <em>n<\/em>-propane, isobutane, <em>n<\/em>-butane, and neopentane at concentrations of 5000 \u00b5g\/mL. We also offer singles of each analyte at 5000 \u00b5g\/mL.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Our proprietary manufacturing process was optimized to ensure standards are accurate, reproducible, and stable.<\/li>\n\n\n\n<li>High analyte concentrations allow for flexible calibration curves.<\/li>\n\n\n\n<li>Second independent lots available to ensure you can meet your requirements without needing to source another supplier.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Common Challenges in Residual Solvent Gases Testing<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Difficulties with accuracy, reproducibility, and stability are well-known frustrations in labs analyzing for residual solvent gases across the cannabis industry. Because of the volatility of residual solvents gases, well-thought-out methodologies utilizing proper care and handling of the standards is crucial to ensure reliable calibration curves. To make sure you have all the tools to feel confident in handling your standards, we published a convenient <a href=\"https:\/\/discover.restek.com\/articles\/ffar4121\/best-practices-for-handling-and-using-volatile-analytical-standards\" data-type=\"post\" data-id=\"43557\"><strong>Volatile Standards Handling Guide<\/strong><\/a> that covers the most important aspects of handling residual solvents gases, from ensuring analytes are in the solution prior to opening the ampul to recommendations for the best tools in constructing calibration solutions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">While handling is certainly important, starting with reliable standards you can trust is perhaps even more critical. Each step in our production process, from solvent choice to ampul design to quality testing, is safeguarded to ensure standards are optimized for accuracy, stability, and reproducibility. We\u2019ve taken measures to ensure that our residual solvent gases standards are optimized for performance and stability so that you can avoid common frustrations experienced with these standards and have confidence in your analysis every time.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Our Residual Solvent Gases Standards Are Optimized to Meet All of Your Testing Needs<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Proprietary Manufacturing and Tailored Formations<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Manufacturing reliable standards starts with creating specific and tailored formulations that have been subjected to rigorous stability and performance studies. Each of our neat materials is assayed by multiple techniques prior to formulation in order to assign an accurate purity value. After purity of neat materials is confirmed, our scientists develop optimized formulations, which are then subjected to rigorous studies to confirm integrity.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A particularly important consideration in the formulation of residual solvents gases standards is solvent choice. To support these extremely volatile, nonpolar hydrocarbons, choosing a solvent that strikes a balance between maximizing solubility interactions while not interfering with the analytes of interest is crucial.&nbsp; 1,2,4-trimethylbenzene was selected as the most optimal solvent, producing exceptionally stable and reproducible standards. Beyond solvent choice, we have tailored each of the steps in our manufacturing processes to ensure the integrity of the standards are preserved in each subsequent step.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Second Independent Lots Ready for Shipment<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Your calibration verifications are important, and we are aware that it can be both frustrating and time-consuming to find second source standards that you can trust to meet your requirements. To eliminate the need to source a second standard, we are ready to provide a second independent lot at the time of your order, so there\u2019s no waiting or hassle in finding a second lot for verification. Our independent lots are prepared by two different chemists using separate NIST-calibrated balances and are assayed post-ampulation to ensure lot-to-lot consistency.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Optimized for Consistency and Easier Handling<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">To help eliminate the frustrations of poor lot-to-lot and ampul-to-ampul reproducibility frequently reported in residual solvent gases standards, we have taken measures to address concerns both in handling and the integrity of the standards themselves. Our optimized design is specifically tailored to reduce volatility issues, support easier handling, and ensure you are set up for success in generating your calibration solutions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>High Analyte Concentration for Added Flexibility in Constructing Calibrations<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The action limits for residual solvent cannabis testing vary significantly from state-to-state, and, indeed, some action limits are set at 5000 ppm. To provide the most flexibility in constructing your calibration curves, we chose a concentration at 5000 ppm for all four target analytes. Starting with a higher analyte concentration gives you the freedom to construct your curves according to your specific requirements and methodologies.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Excellent Chromatographic Performance and Reproducibility<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Chromatographic Performance<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">To assess chromatographic performance, our residual solvents gases standard (<a href=\"https:\/\/www.restek.com\/p\/36024\" target=\"_blank\" rel=\"noopener\">cat# 36024<\/a>) was prepared at a concentration of 125 \u03bcg\/mL in 1,2,4-trimethylbenzene. Gas-tight syringes were used in constructing standard solutions to control any evaporative loss of the standard. To perform testing 50 \u03bcL of the working standard solution was added to a 20 mL headspace vial, then tested on the Rxi-624Sil MS column by HS-Syringe-GC-MS. Excellent chromatographic separations and peak shape were achieved for all four compounds. For the full method conditions and chromatographic results of this analysis, see Figure 1 below.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> Our Residual Solvent Gases Standard achieved exceptional chromatographic performance.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1234.png\" alt=\"Residual Solvent Gases Standard\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1234<\/p><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rxi-624Sil MS, 30 m, 0.25 mm ID, 1.40 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/13868\" rel=\"noopener\">cat.# 13868<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Residual Solvent Gases Standard (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/36024\" rel=\"noopener\">cat.# 36024<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>1,2,4-Trimethylbenzene<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>125 \u00b5g\/mL<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>250 \u00b5L headspace-syringe split (split ratio 10:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz, straight\/SPME inlet liner, 1.8 mm x 5.0 x 95 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23279\" rel=\"noopener\">cat.# 23279<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Headspace-Syringe<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Instrument:<\/th><td>AOC-6000 Plus <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Syringe Temp.:<\/th><td>150 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Sample Temp.:<\/th><td>80 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Sample Equil. Time:<\/th><td>45  min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Speed:<\/th><td>25 mL\/min <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Dwell:<\/th><td>0.05 <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>30 &#176;C (hold 6 min) to 85 &#176;C at 15 &#176;C\/min (hold 2 min) to 250 &#176;C at 35 &#176;C\/min (hold 1 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>2 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>QP2020 NX MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Scan Program:<\/th><td><\/td><\/tr><tr><td style=\"text-align:left\" colspan=\"2\"><table class=\"conditions_sim\"><thead><tr><th style=\"padding: 0 5px\">Group<\/th><th style=\"padding: 0 5px\">Start Time<br \/>(min)<\/th><th style=\"padding: 0 5px\">Scan Range<br \/>(amu)<\/th><th style=\"padding: 0 5px\">Scan Rate<br \/>(scans\/sec)<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>0<\/td><td>35 &#8211; 350<\/td><td>1111<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>200 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Solvent Delay Time:<\/th><td>0  min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>PFTBA <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Shimadzu GC 2030<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>A Residual Solvents Gases (cat# 36024) working standard was prepared at 125 \u00b5g\/mL. 50 \u00b5L of that working solution was added to a 20 mL headspace vial, then tested using HS-Syringe-GC-MS.<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Conditions were optimized for an expanded list of residual solvents, similar to GC_GN1198.<br \/><br \/>This chromatogram was generated with our residual solvent gases standard mix (cat #36024). We also offer single solutions of each analyte. Please see the catalog numbers below for reference.<br \/><br \/><b>Cat.#\tDescription<br \/><\/b>36020\tPropane Standard<br \/>36021\tIsobutane Standard<br \/>36022\tButane Standard<br \/>36023\tNeopentane Standard<br \/><br \/><br \/><\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>36024<\/li><li>13868<\/li><li>23279<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Cannabis<\/li><li>Gases<\/li><li>Hemp<\/li><li>Residual<\/li><li>Solvent<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1234.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Reproducibility<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Reproducibility is a crucial component in analyzing for residual solvent gases, so we made it our top priority to ensure our standards were consistent both lot-to-lot and ampul-to-ampul. We optimized our manufacturing process and took measures to ensure these volatile compounds were properly safeguarded at each step in our production process. Rigorous testing was performed to ensure a consistent product, so you can have the assurance you need in performing your analyses.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To demonstrate reproducibility for our standards, we tested three randomly-selected ampuls each from four separate lots. Reproducibility was then calculated both within and between lots for each of the target analytes. To evaluate reproducibility within lots, we calculated the %RSDs for each of the three ampuls across a single lot for each of the targeted compounds (results reported in Table I). Exceptionally low %RSDs were achieved within lots, with an overall %RSD of less than 4% across all lots and all analytes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To measure the reproducibility of our manufacturing process across lots, we calculated the % difference between each of the four lots, then took the average of these % difference values. Table II below reports the average as well as the range of % difference values. With these outstanding results in reproducibility, both within and between lots, you can have confidence that our residual solvent gases standards will consistently perform at the level you need analysis after analysis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> Reproducibility within Lots for Restek\u2019s Residual Solvent Gases Standards<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\"><strong>Target Analyte<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"4\"><strong>Response % RSD Across Ampuls in Each Lot (n=3)<\/strong><\/td><\/tr><tr><td><strong>Lot 1<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Lot 2<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Lot 3<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Lot 4<\/strong><\/td><\/tr><tr><td><em>n<\/em>-Propane<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.1%<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.7%<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.7%<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.5%<\/td><\/tr><tr><td>Isobutane<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.3%<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.4%<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.1%<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.5%<\/td><\/tr><tr><td><em>n<\/em>-Butane<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.5%<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.3%<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.9%<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.5%<\/td><\/tr><tr><td>Neopentane<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.2%<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.3%<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.6%<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.7%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II:<\/strong> Reproducibility between Lots for Restek\u2019s Residual Solvent Gases Standards<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Target Analyte<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Average Response % Difference Across Four Lots<\/strong><\/td><\/tr><tr><td><em>n<\/em>-Propane<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.3% (Range = 2.5% \u2013 11.5%)<\/td><\/tr><tr><td>Isobutane<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.6% (Range = 0.3% &#8211; 3.2%)<\/td><\/tr><tr><td><em>n<\/em>-Butane<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.7% (Range = 0.2% &#8211; 3.4%)<\/td><\/tr><tr><td>Neopentane<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.4% (Range = 0.4% &#8211; 2.6%)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">How Do Our Residual Solvent Gases Standards Compare?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Because we know how important reproducibility is in analyzing for residual solvent gases, we performed testing on two different competitor standards to provide transparency in how our standards compare to the current standards on the market. Additional compounds were present in some of these competitor solutions, but our focus was specifically on the residual solvent gases: n-propane, isobutane, n-butane, and neopentane.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Three ampuls each from two separate lots were evaluated for each of the two competitors. The %RSDs calculated within lots for Competitor A are reported in Table III, with an overall %RSD of less than 10%. The % difference between lots for Competitor A ranged from 28% to 50% and are reported in Table IV.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table III:<\/strong> Competitor A* Reproducibility within Lots<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\" rowspan=\"2\"><strong>Target Analyte<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\"><strong>Response %RSD Across Ampuls in Each Lot (n=3)<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Lot 1<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Lot 2<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><em>n<\/em>-Propane<\/td><td class=\"has-text-align-center\" data-align=\"center\">8.9%<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.2%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Isobutane<\/td><td class=\"has-text-align-center\" data-align=\"center\">9.2%<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.8%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><em>n<\/em>-Butane<\/td><td class=\"has-text-align-center\" data-align=\"center\">9.1%<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.8%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Neopentane<\/td><td class=\"has-text-align-center\" data-align=\"center\">9.5%<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.5%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table IV:<\/strong> Competitor A* Reproducibility between Lots<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Target Analyte<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Response % Difference Across Two Lots&nbsp;<\/strong><\/td><\/tr><tr><td><em>n<\/em>-Propane<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;31.8%<\/td><\/tr><tr><td>Isobutane&nbsp;<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;32.1%<\/td><\/tr><tr><td><em>n<\/em>-Butane<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;50.1%<\/td><\/tr><tr><td>Neopentane<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;28.4%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">*Formulated with N,N-dimethylacetamide solvent.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The results for Competitor B are reported in Table V and Table VI. Please note that the standard from Competitor B did not contain isobutane and neopentane, so these compounds were not evaluated. The overall %RSD within lots for Competitor B was less than 7%, and the % difference between lots for the two measured compounds (n-propane and n-butane) was 34.0% and 28.4%, respectively.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table V:<\/strong> Competitor B\u2020 Reproducibility within Lots<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\"><strong>Target Analyte<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\"><strong>Response %RSD Across Ampuls in Each Lot (n=3)<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Lot 1<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Lot 2<\/strong><\/td><\/tr><tr><td><em>n<\/em>-Propane<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.7%<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.8%<\/td><\/tr><tr><td>Isobutane<\/td><td class=\"has-text-align-center\" data-align=\"center\">NA<\/td><td class=\"has-text-align-center\" data-align=\"center\">NA<\/td><\/tr><tr><td><em>n<\/em>-Butane<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.4%<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.2%<\/td><\/tr><tr><td>Neopentane<\/td><td class=\"has-text-align-center\" data-align=\"center\">NA<\/td><td class=\"has-text-align-center\" data-align=\"center\">NA<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table VI:<\/strong> Competitor B\u2020 Reproducibility between Lots<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Target Analyte<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Response % Difference Across Two Lots<\/strong><\/td><\/tr><tr><td><em>n<\/em>-Propane<\/td><td class=\"has-text-align-center\" data-align=\"center\">34.0%<\/td><\/tr><tr><td>Isobutane<\/td><td class=\"has-text-align-center\" data-align=\"center\">NA<\/td><\/tr><tr><td><em>n<\/em>-Butane<\/td><td class=\"has-text-align-center\" data-align=\"center\">28.4%<\/td><\/tr><tr><td>Neopentane<\/td><td class=\"has-text-align-center\" data-align=\"center\">NA<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">\u2020Formulated with triacetin solvent.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A comparison of the data from our standards to these two competitors reveals a clear Restek advantage for reproducibility both from lot-to-lot and ampul-to-ampul. Particularly in evaluating the differences from lot to lot, our standards offer exceptional consistency and far outperforms these two competitor standards. Backed by this data, the proven integrity of our standards, and our optimized production process, you can have assurance that our standards will deliver the reproducibility you need in your residual solvent gases testing.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Have Confidence in Your Residual Solvent Gases Analysis with Our Exceptionally Reliable Standards<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Our Restek Team takes pride in helping to provide solutions to the everyday challenges of scientists across the globe. With data showing superior chromatographic performance and reproducibility and a highly controlled manufacturing process, we are confident in our residual solvent gases standards. These highly consistent standards offer a solution to cannabis laboratories struggling with reproducibility in their calibration solutions. Start your analysis with confidence knowing that you are set up for success with our dependable residual solvent gases standards.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Find our full selection of reference standards <a href=\"https:\/\/www.restek.com\/c\/1102\" target=\"_blank\" rel=\"noopener\">here.<\/a><\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-radius:20px;background-color:#c2e0f4;padding-top:10px;padding-right:20px;padding-bottom:10px;padding-left:20px\">\n<p class=\"wp-block-paragraph\">For specific care and handling instruction for your Residual Solvent Gases Standards, see our&nbsp;<strong>Volatile Standards Handling Guide<\/strong>&nbsp;at&nbsp;<a href=\"https:\/\/discover.restek.com\/articles\/ffar4121\/best-practices-for-handling-and-using-volatile-analytical-standards\" data-type=\"post\" data-id=\"43557\"><strong>www.restek.com\/articles\/best-practices-for-handling-and-using-volatile-analytical-standards<\/strong><\/a><\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:41px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div id=\"support\" class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><style>.kadence-column105086_2566ee-66 > .kt-inside-inner-col{padding-top:var(--global-kb-spacing-md, 2rem);padding-right:var(--global-kb-spacing-lg, 3rem);padding-left:var(--global-kb-spacing-lg, 3rem);}.kadence-column105086_2566ee-66 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column105086_2566ee-66 > .kt-inside-inner-col{flex-direction:column;}.kadence-column105086_2566ee-66 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column105086_2566ee-66 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column105086_2566ee-66{position:relative;}@media all and (max-width: 1024px){.kadence-column105086_2566ee-66 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column105086_2566ee-66 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column105086_2566ee-66\"><div class=\"kt-inside-inner-col\"><div class=\"aligncenter wp-block-icon\"><svg style=\"width:60px;\" aria-hidden=\"true\" focusable=\"false\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\">\n\t<path fill-rule=\"evenodd\" d=\"M15.5 9.5a1 1 0 100-2 1 1 0 000 2zm0 1.5a2.5 2.5 0 100-5 2.5 2.5 0 000 5zm-2.25 6v-2a2.75 2.75 0 00-2.75-2.75h-4A2.75 2.75 0 003.75 15v2h1.5v-2c0-.69.56-1.25 1.25-1.25h4c.69 0 1.25.56 1.25 1.25v2h1.5zm7-2v2h-1.5v-2c0-.69-.56-1.25-1.25-1.25H15v-1.5h2.5A2.75 2.75 0 0120.25 15zM9.5 8.5a1 1 0 11-2 0 1 1 0 012 0zm1.5 0a2.5 2.5 0 11-5 0 2.5 2.5 0 015 0z\" \/>\n<\/svg>\n<\/div>\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading105086_5f5ba2-eb, .wp-block-kadence-advancedheading.kt-adv-heading105086_5f5ba2-eb[data-kb-block=\"kb-adv-heading105086_5f5ba2-eb\"]{max-width:708px;margin-right:auto;margin-left:auto;padding-bottom:0px;text-align:center;font-style:normal;}.wp-block-kadence-advancedheading.kt-adv-heading105086_5f5ba2-eb mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading105086_5f5ba2-eb[data-kb-block=\"kb-adv-heading105086_5f5ba2-eb\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading105086_5f5ba2-eb img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading105086_5f5ba2-eb[data-kb-block=\"kb-adv-heading105086_5f5ba2-eb\"] img.kb-inline-image{width:150px;vertical-align:baseline;}<\/style>\n<h2 class=\"kt-adv-heading105086_5f5ba2-eb wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading105086_5f5ba2-eb\"><strong>Hai Bisogno di Aiuto con gli Standard di Riferimento?<\/strong><\/h2>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\" style=\"font-size:20px\">Dalla selezione del metodo alle raccomandazioni sui prodotti, i nostri esperti di standard di riferimento sono qui per aiutarti a orientarti in workflow complessi e ottenere risultati accurati e affidabili.<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns105086_07229f-0a{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns105086_07229f-0a .kt-button{font-weight:normal;font-style:normal;}.kt-btns105086_07229f-0a .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns105086_07229f-0a .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns105086_07229f-0a .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns105086_07229f-0a .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns105086_07229f-0a .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns105086_07229f-0a .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns105086_07229f-0a .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns105086_07229f-0a\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn105086_47eb57-b1.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn105086_47eb57-b1.kb-button{color:var(--global-palette9, #ffffff);background:#ff9a00;border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-right-radius:8px;border-bottom-left-radius:8px;border-top-color:#ff9a00;border-right-color:#ff9a00;border-bottom-color:#ff9a00;border-left-color:#ff9a00;padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn105086_47eb57-b1.kb-button:not(.specificity):not(.extra-specificity){text-decoration:none;}.kb-btn105086_47eb57-b1.kb-button .kb-svg-icon-wrap{color:var(--global-palette9, #ffffff);}.kb-btn105086_47eb57-b1.kb-button:hover .kb-svg-icon-wrap, .kb-btn105086_47eb57-b1.kb-button:focus .kb-svg-icon-wrap{color:var(--global-palette9, #ffffff);}.wp-block-kadence-advancedbtn .kb-btn105086_47eb57-b1.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn105086_47eb57-b1.kb-button:focus{color:var(--global-palette9, #ffffff);background:#f37c20;box-shadow:var(--kb-btn-shadow-hover, none);}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn105086_47eb57-b1.kb-button{border-top-color:#ff9a00;border-right-color:#ff9a00;border-bottom-color:#ff9a00;border-left-color:#ff9a00;}}@media all and (max-width: 767px){.wp-block-kadence-advancedbtn .kb-btn105086_47eb57-b1.kb-button{border-top-color:#ff9a00;border-right-color:#ff9a00;border-bottom-color:#ff9a00;border-left-color:#ff9a00;}}<\/style><a class=\"kb-button kt-button button kb-btn105086_47eb57-b1 kt-btn-size-large kt-btn-width-type-auto kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/explore.restek.com\/contact-reference-standards-it\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\">Contatta un Esperto di Standard di Riferimento<\/span><\/a><\/div>\n\n\n\n<div style=\"height:12px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n<\/div><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Related Products<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/36024\">                                N\u00b0 Catalogo 36024                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Standard di Neopentano per Vapori di Solventi Residui, 5000 \u00b5g\/mL in 1,2,4-Trimetilbenzene, 2 mL\/ampolla<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/36024\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/36023\">                                N\u00b0 Catalogo 36023                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Standard di Neopentano per Vapori di Solventi Residui, 5000 \u00b5g\/mL in 1,2,4-Trimetilbenzene, 2 mL\/ampolla<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/36023\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/36022\">                                N\u00b0 Catalogo 36022                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Standard di Butano per Vapori di Solventi Residui, 5000 \u00b5g\/mL in 1,2,4-Trimetilbenzene, 2 mL\/ampolla<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/36022\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/36021\">                                N\u00b0 Catalogo 36021                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Standard di Isobutano per Vapori di Solventi Residui, 5000 \u00b5g\/mL in 1,2,4-Trimetilbenzene, 2 mL\/ampolla<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/36021\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/36020\">                                N\u00b0 Catalogo 36020                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Standard di Propano per Vapori di Solventi Residui, 5000 \u00b5g\/mL in 1,2,4-Trimetilbenzene, 2 mL\/ampolla<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/36020\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13868\">                                N\u00b0 Catalogo 13868                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Colonna capillare GC Rxi-624Sil MS, 30 m, ID 0,25 mm, 1,40 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13868\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23280\">                                N\u00b0 Catalogo 23280                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Liner per iniettore dritto\/SPME Topaz, 1,8 mm x 6,5 x 78,5, per GC Agilent, deattivazione premium, 5 pz.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23280\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21163\">                                N\u00b0 Catalogo 21163                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Vial con bocca crimp per spazio di testa, 20 mm, 20 mL, fondo conico, trasparenti, 1000 pz.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21163\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23083\">                                N\u00b0 Catalogo 23083                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Vial con filettatura per spazio di testa, 18 mm, 20 mL, trasparenti, 1000 pz.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23083\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23092\">                                N\u00b0 Catalogo 23092                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Tappi per spazio di testa con filettatura magnetica, 18 mm e setti in PTFE rosso\/silicone, spessore 1,9 mm, 100 pz.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23092\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23094\">                                N\u00b0 Catalogo 23094                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Tappi spazio di testa con filettatura magnetica, 18 mm e setti in PTFE\/clorobutile rosso, 100 pz.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23094\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22831\">                                N\u00b0 Catalogo 22831                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Discontinued: Tappi bocca crimp magnetici con setti in PTFE\/silicone, 20 mm con foro di 8 mm, dorati, preassemblati, 100 pz.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22831\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22835\">                                N\u00b0 Catalogo 22835                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Discontinued: Tappi bocca crimp magnetici con setti in PTFE\/butile, 20 mm con foro di 8 mm, dorati, preassemblati, 100 pz.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22835\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21763\">                                N\u00b0 Catalogo 21763                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Guarnizioni bocca crimp in alluminio con setti in PTFE\/silicone, argentate, preassemblate, 20 mm, 100 pz.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21763\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21761\">                                N\u00b0 Catalogo 21761                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Guarnizioni bocca crimp in alluminio con setti in PTFE\/gomma butilica grigia, argentate, preassemblate, 20 mm, 100 pz.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21761\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24571\">                                N\u00b0 Catalogo 24571                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Siringa, Hamilton 1750 (500 \u00b5L\/LTN\/22\/2&quot;\/2\u00a0pt), punta PTFE, a tenuta di gas<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24571\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24742\">                                N\u00b0 Catalogo 24742                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Siringa, SGE (500 \u00b5L\/F\/25\/50 mm\/2\u00a0pt), punta in PTFE, a tenuta di gas<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24742\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24559\">                                N\u00b0 Catalogo 24559                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Siringa, Hamilton 1702 (25 \u00b5L\/N\/22s\/2&quot;\/\u00a02pt), punta in PTFE, a tenuta di gas<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24559\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24727\">                                N\u00b0 Catalogo 24727                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Siringa, SGE (25 \u00b5L\/F\/25\/50 mm\/2\u00a0pt), punta in PTFE, a tenuta di gas<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24727\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24563\">                                N\u00b0 Catalogo 24563                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Siringa, Hamilton 1710 (100 \u00b5L\/N\/22s\/2&quot;\/\u00a02pt), punta in PTFE, a tenuta di gas<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24563\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24734\">                                N\u00b0 Catalogo 24734                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Siringa, SGE (100 \u00b5L\/F\/25\/50 mm\/2\u00a0pt), punta in PTFE, a tenuta di gas<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24734\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24902\">                                N\u00b0 Catalogo 24902                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Valvola di campionamento di precisione Mininert, 18 mm, a vite, 12 pz.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24902\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24906\">                                N\u00b0 Catalogo 24906                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Setti di ricambio per valvole per campionamento di precisione Mininert, 50 pz.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24906\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24907\">                                N\u00b0 Catalogo 24907                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Strumento per inserimento setto per valvole per campionamento di precisione Mininert, cad.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24907\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22643\">                                N\u00b0 Catalogo 22643                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rack di stoccaggio in polipropilene\ufeff per vial per spazio di testa da 6, 10 o 20 mL, cad.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22643\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22644\">                                N\u00b0 Catalogo 22644                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rack di stoccaggio in polipropilene\ufeff per vial per spazio di testa da 6, 10 o 20 mL, 5 pz.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22644\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">                                N\u00b0 Catalogo 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">\ufeffLeak Detector Elettronico Restek\ufeff<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Are you experiencing challenges in reproducibility and lot-to-lot consistency with your residual solvent gases standards? Our Restek team has gone above and beyond to overcome these common pain points in testing and to produce the best quality residual solvent gases standards across the cannabis industry. Learn more about the measures we\u2019ve taken to ensure a highly consistent product.<\/p>\n","protected":false},"author":11,"featured_media":6943,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[2784],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-43592","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles"],"acf":[],"taxonomy_info":{"category":[{"value":2784,"label":"Articles"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-FFSS4116-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/it\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":2784,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":2784,"taxonomy":"category","description":"","parent":0,"count":509,"filter":"raw","cat_ID":2784,"category_count":509,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43592","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=43592"}],"version-history":[{"count":14,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43592\/revisions"}],"predecessor-version":[{"id":103239,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43592\/revisions\/103239"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media\/6943"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=43592"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=43592"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=43592"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=43592"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=43592"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=43592"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=43592"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=43592"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=43592"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}