{"id":43606,"date":"2021-01-12T00:00:00","date_gmt":"2021-01-12T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/analisi-diretta-rapida-e-affidabile-dei-pesticidi-polari-negli-spinaci\/"},"modified":"2025-12-19T14:16:12","modified_gmt":"2025-12-19T14:16:12","slug":"analisi-diretta-rapida-e-affidabile-dei-pesticidi-polari-negli-spinaci","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/articoli\/fsfa3215-it\/analisi-diretta-rapida-e-affidabile-dei-pesticidi-polari-negli-spinaci","title":{"rendered":"Analisi diretta rapida e affidabile dei pesticidi polari negli spinaci"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>Non comporta processi di derivatizzazione o accoppiamenti ionici che richiedono tempo, n\u00e9 lunghe attese per l\u2019equilibratura della colonna.<\/li>\n\n\n\n<li>La fase stazionaria rappresenta una soluzione unica e offre una buona ritenzione e un\u2019eluizione efficiente, ottenendo una buona forma del picco.<\/li>\n\n\n\n<li>La robusta prestazione della colonna garantisce cromatografie stabili e risultati affidabili.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019analisi diretta dei pesticidi polari, come il glifosato, il suo principale metabolita (l\u2019AMPA) e il glufosinato, risulta difficoltosa perch\u00e9 queste&nbsp;sostanze non sono trattenute in maniera ottimale sulle colonne a fase inversa e la chelazione con le superfici metalliche nel sistema LC-MS\/MS pu\u00f2 ridurre significativamente la risposta. Per migliorare le prestazioni in genere si utilizzano la derivatizzazione e i reagenti di coppia&nbsp;ionica, che tuttavia richiedono pi\u00f9 tempo per la preparazione del campione e possono produrre spiacevoli effetti collaterali (precipitati,&nbsp;lunghi tempi di equilibratura, contaminazione del sistema, ecc.).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019uso di una colonna Raptor Polar X rappresenta una soluzione ottimale perch\u00e9 l\u2019innovativa fase stazionaria offre un\u2019interazione pi\u00f9 forte con&nbsp;i composti polari anionici. Presenta modalit\u00e0 di ritenzione ibride (HILIC e a scambio ionico) e offre una forte ritenzione pur consentendo una&nbsp;veloce eluizione degli analiti in picchi di forma simmetrica attraverso semplici modifiche della fase mobile. In questa analisi dei pesticidi polari&nbsp;negli spinaci si riscontra un\u2019eccellente prestazione cromatografica per tutti e tre i composti con un tempo di analisi complessivo di appena otto&nbsp;minuti. Inoltre la forma dei picchi e i tempi di ritenzione rimangono stabili dopo centinaia di iniezioni di matrice, una semplice sostituzione&nbsp;della precolonna ripristina la piena rispondenza prestazionale. Questo flusso di lavoro veloce, semplice ed efficace rappresenta una buona&nbsp;alternativa per i laboratori alimentari interessati all\u2019analisi diretta dei pesticidi polari senza dover ricorrere a procedure lunghe e complesse.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0547.png\" alt=\"Polar Pesticides in Spinach on Raptor Polar X by LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FS0547<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion 1<\/th><th style=\"text-align: center;width: 75px\">Product Ion 2<\/th><th style=\"text-align: center;width: 75px\">Product Ion 3<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\">AMPA<\/td><td class=\"oth\">100<\/td><td class=\"oth\">110.10<\/td><td class=\"oth\">79.05<\/td><td class=\"oth\">63.10<\/td><td class=\"oth\">81.10<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Glufosinate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51276-47-2\/Glufosinate\" target=\"_blank\" rel=\"noopener\">Glufosinate<\/a><\/td><td class=\"oth\">100<\/td><td class=\"oth\">180.20<\/td><td class=\"oth\">85.15<\/td><td class=\"oth\">95.10<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Glyphosate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1071-83-6\/Glyphosate\" target=\"_blank\" rel=\"noopener\">Glyphosate<\/a><\/td><td class=\"oth\">100<\/td><td class=\"oth\">168.10<\/td><td class=\"oth\">63.05<\/td><td class=\"oth\">79.05<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor Polar X  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9311A32\" rel=\"noopener\">cat.# 9311A32<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>30 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Raptor Polar X guard column cartridge 5 mm, 2.1 mm ID, 2.7 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9311A0252\" rel=\"noopener\">cat.# 9311A0252<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>35 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Spinach extract<\/td><\/tr>\n<td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>2 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water,  0.5% formic acid <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Acetonitrile, 0.5% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.5<\/td><td>35<\/td><td>65<\/td><\/tr><tr><td>5.0<\/td><td>0.5<\/td><td>90<\/td><td>10<\/td><\/tr><tr><td>6.5<\/td><td>0.5<\/td><td>90<\/td><td>10<\/td><\/tr><tr><td>6.51<\/td><td>0.5<\/td><td>35<\/td><td>65<\/td><\/tr><tr><td>8<\/td><td>0.5<\/td><td>35<\/td><td>65<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>UHPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Frozen spinach was added to a Blixer processor with dry ice (3:1-4:1 ratio) and then ground into a very fine powder. The homogenate was placed into the freezer immediately. A 5.0 gram sample of the spinach powder was weighed into a 50 mL centrifuge tube (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/25846\" rel=\"noopener\">cat.# 25846<\/a>). According to the QuPPe method (Quick Polar Pesticides Method), 5.0 mL of methanol with 1.0% formic acid was added into the centrifuge tube. The tube was shaken by hand for 1 min and then by a mechanical shaker vigorously for 5 min. After centrifuging for 10 min at 4200 rpm, the supernatant was filtered through a 0.22 \u03bcm filter (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23984\" rel=\"noopener\">cat.# 23984<\/a>). The final extract was fortified with the AMPA, glufosinate, and glyphosate at a final concentration of 100 ng\/mL.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9311A0252<\/li><li>9311A32<\/li><li>25846<\/li><li>23984<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0547.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Questo flusso di lavoro LC-MS\/MS  per l&#8217;analisi diretta dei pesticidi polari negli spinaci, oltre ad essere veloce e semplice, fornisce una buona ritenzione e forma dei picchi su centinaia di iniezioni di matrice su una colonna Raptor Polar X.<\/p>\n","protected":false},"author":11,"featured_media":70564,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[788],"tags":[],"industries-application":[2290,2292],"post-badge":[],"resource-type":[],"product-library":[2535,2517],"resource-technique":[2334,2364],"ppma_author":[414],"class_list":["post-43606","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articoli","industries-application-food-beverage-it","industries-application-sicurezza-alimentare-it","product-library-colonne-lc","product-library-prodotti-per-cromatografia-liquida","resource-technique-cromatografia-liquida-lc","resource-technique-ms-ms-it"],"acf":[],"taxonomy_info":{"category":[{"value":788,"label":"Articoli"}],"industries-application":[{"value":2290,"label":"Food &amp; Beverage"},{"value":2292,"label":"Sicurezza alimentare"}],"product-library":[{"value":2535,"label":"Colonne LC"},{"value":2517,"label":"Prodotti per Cromatografia Liquida"}],"resource-technique":[{"value":2334,"label":"Cromatografia Liquida (LC)"},{"value":2364,"label":"MS\/MS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-FSFA3215-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/it\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":788,"name":"Articoli","slug":"articoli","term_group":0,"term_taxonomy_id":788,"taxonomy":"category","description":"","parent":0,"count":509,"filter":"raw","cat_ID":788,"category_count":509,"category_description":"","cat_name":"Articoli","category_nicename":"articoli","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43606","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=43606"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43606\/revisions"}],"predecessor-version":[{"id":76039,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43606\/revisions\/76039"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media\/70564"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=43606"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=43606"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=43606"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=43606"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=43606"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=43606"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=43606"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=43606"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=43606"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}