{"id":43695,"date":"2021-02-03T00:00:00","date_gmt":"2021-02-03T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/get-fast-definitive-data-for-blood-alcohol-testing\/"},"modified":"2026-08-11T15:18:36","modified_gmt":"2026-08-11T15:18:36","slug":"get-fast-definitive-data-for-blood-alcohol-testing","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/artikel\/gnar3489\/get-fast-definitive-data-for-blood-alcohol-testing","title":{"rendered":"Get Fast, Definitive Data for Blood Alcohol Testing"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Get Fast, Definitive Data for Blood Alcohol Testing<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Our Rtx-BAC Plus 1 and Rtx-BAC Plus 2 columns separate all critical compounds to baseline in less than 2 minutes. Check standards containing internal standards are also available. Increase accuracy and productivity with these columns and standards for blood alcohol analysis.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Rtx-BAC Plus 1 and Rtx-BAC Plus 2 Columns<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences. These columns are individually tested with ethanol, methanol, acetone,&nbsp;<em>tert<\/em>-butanol (IS), acetaldehyde, isopropanol, and 1-propanol (IS) to ensure performance. Robust and reproducible column chemistry provides longer column lifetime and accurate, consistent results.<\/p>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">RTX-BAC Plus 1 columns<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/18004\">                                N\u00b0 Catalogo 18004                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Colonna capillare GC Rtx- BAC PLUS 1, 30 m, ID 0,32 mm, 1,8 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/18004\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Rtx-BAC Plus 2 columns<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/18006\">                                N\u00b0 Catalogo 18006                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Colonna capillare GC Rtx- BAC PLUS 2, 30 m, ID 0,32 mm, 0,6 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/18006\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Resolution Control Standards<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Available with&nbsp;<em>tert<\/em>-butanol or 1-propanol, these check standards contain the internal standard you need. Use to verify the retention time for each compound normally included in a blood alcohol test, and to verify that the compounds are resolved from and do not interfere with one another.<\/p>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">BAC resolution control standard t-B<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/36011\">                                N\u00b0 Catalogo 36011                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Standard t-B di controllo della risoluzione BAC, 100 mg\/dL cad. in acqua, 1 mL\/ampolla<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/36011\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">BAC resolution control standard n-P<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/36010\">                                N\u00b0 Catalogo 36010                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Standard n-P di controllo della risoluzione BAC, 100 mg\/dL cad. in acqua, 1 mL\/ampolla<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/36010\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Related Links<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/CFSS1483.pdf\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/wp-content\/uploads\/CFSS1483.pdf\">Fast, Definitive Data for Blood Alcohol Testing<\/a>\u00a0(PDF)<\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/chromatogram-library\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/chromatogram-library\" target=\"_blank\" rel=\"noopener\">Chromatograms<\/a><\/li>\n<\/ul>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Separate all critical blood alcohol analysis compounds to baseline in less than 2 minutes with increased accuracy and productivity using Restek BAC columns and resolution control standards.<\/p>\n","protected":false},"author":11,"featured_media":90421,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[787],"tags":[],"industries-application":[2239,2240],"post-badge":[],"resource-type":[],"product-library":[2480,2492,2507,2482],"resource-technique":[2324],"ppma_author":[414],"class_list":["post-43695","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-artikel","industries-application-forensik","industries-application-forensische-toxikologie","product-library-gaschromatographie-produkte","product-library-gc-saulen","product-library-flussige-referenzstandards","product-library-referenzstandards","resource-technique-gaschromatographie-gc"],"acf":[],"taxonomy_info":{"category":[{"value":787,"label":"Artikel"}],"industries-application":[{"value":2239,"label":"Forensik"},{"value":2240,"label":"Forensische Toxikologie"}],"product-library":[{"value":2480,"label":"Gaschromatographie Produkte"},{"value":2492,"label":"GC S\u00e4ulen"},{"value":2507,"label":"Fl\u00fcssige Referenzstandards"},{"value":2482,"label":"Referenzstandards"}],"resource-technique":[{"value":2324,"label":"Gaschromatographie (GC)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-gnar3489-1-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/it\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":787,"name":"Artikel","slug":"artikel","term_group":0,"term_taxonomy_id":787,"taxonomy":"category","description":"","parent":0,"count":495,"filter":"raw","cat_ID":787,"category_count":495,"category_description":"","cat_name":"Artikel","category_nicename":"artikel","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43695","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=43695"}],"version-history":[{"count":7,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43695\/revisions"}],"predecessor-version":[{"id":78797,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43695\/revisions\/78797"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media\/90421"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=43695"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=43695"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=43695"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=43695"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=43695"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=43695"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=43695"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=43695"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=43695"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}