{"id":43708,"date":"2020-12-17T00:00:00","date_gmt":"2020-12-17T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/colonne-gc-rxi\/"},"modified":"2025-12-19T15:52:18","modified_gmt":"2025-12-19T15:52:18","slug":"colonne-gc-rxi","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/articoli\/gnbr1843-it\/colonne-gc-rxi","title":{"rendered":"Colonne GC Rxi"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-16018d1d wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-background wp-element-button\" href=\"https:\/\/www.restek.com\/global\/it\/search?Ntt=rxi&amp;Ns=bestMatch\" style=\"background-color:#f67f01;padding-right:70px;padding-left:70px\" target=\"_blank\" rel=\"noopener\"><strong><strong>Rxi<br>Prodotti<\/strong><\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-16018d1d wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-background wp-element-button\" href=\"https:\/\/www.restek.com\/global\/it\/resource-hub-search?s=rxi\" style=\"background-color:#f67f01;padding-right:50px;padding-left:50px\" target=\"_blank\" rel=\"noopener\"><strong><strong>Rxi<br>Letteratura tecnica<\/strong><\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-16018d1d wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-background wp-element-button\" href=\"https:\/\/www.restek.com\/global\/it\/chromatogram-library?s=rxi\" style=\"background-color:#f67f01;padding-right:50px;padding-left:50px\" target=\"_blank\" rel=\"noopener\"><strong><strong>Rxi<br>Cromatogrammi<\/strong><\/strong><\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Sfrutta l&#8217; inerzia straordinaria, il bleeding ridotto e l&#8217; elevata riproducibilit\u00e0 della tecnologia Rxi 3-in-1 per avere:<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Dati precisi<\/strong><\/li>\n\n\n\n<li><strong>Risultati corretti in breve tempo<\/strong><\/li>\n\n\n\n<li><strong>Tempi di attivit\u00e0 dello strumento ottimizzati<\/strong><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Gli utenti richiedono dati veloci e precisi.<br>Scegliendo le colonne Restek Rxi potrai soddisfare questa esigenza.<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"596\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNBR1843A-01.jpg\" alt=\"\" class=\"wp-image-21688\" style=\"width:231px;height:auto\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNBR1843A-01.jpg 600w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNBR1843A-01-300x298.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNBR1843A-01-150x150.jpg 150w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n<p>Diciamo la verit\u00e0. Prima ancora di indossare il camice c\u2019\u00e8 gi\u00e0 ad aspettarti una mole di lavoro maggiore di quella che riesci a gestire. Il tuo strumento deve funzionare, e deve poterlo fare subito. Ma andare veloci non basta: bisogna ottenere subito i risultati corretti, risparmiando denaro nel processo. I campioni arrivano con un flusso continuo: la produzione di prodotti e di dati di eccellente qualit\u00e0 non deve essere da meno. In poche parole, \u00e8 fondamentale avere una colonna gascromatografica in grado di produrre i dati di cui hai bisogno quando ti occorrono.<\/p>\n\n\n\n<p>Conosciamo le problematiche che devi affrontare. Infatti, molti nostri esperti di cromatografia in-house un tempo erano in prima linea come te ed \u00e8 proprio per questo che operiamo in questo modo. Restek ha sviluppato la famiglia di colonne in silice fusa Rxi per aiutarti a risolvere le sfide che affronti ogni giorno nel tuo laboratorio. Le nostre priorit\u00e0 sono l\u2019inerzia, la stabilit\u00e0 e riproducibilit\u00e0, il bleeding e la forma del picco. Restek Pure Chromatography ti consente di svolgere il tuo lavoro correttamente e velocemente.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Colonne Rxi: create per il tuo successo<\/h2>\n\n\n\n<p>Sappiamo che per te, come cliente, \u00e8 estremamente importante che i tuoi fornitori siano onesti quando trasmettono un reclamo. In quanto scienziati, anche per noi l\u2019onest\u00e0 \u00e8 fondamentale per conservare la credibilit\u00e0 e rispettare i nostri principi. Restek monitora l\u2019intero flusso di produzione delle colonne Rxi, per garantire un prodotto di qualit\u00e0 eccellente in grado di offrire sempre le prestazioni che promettiamo. Le colonne Rxi sono quindi coperte da una garanzia senza pari: Restek Pure Satisfaction.<\/p>\n\n\n\n<p><strong>Silice fusa:<\/strong>&nbsp;Per noi \u00e8 fondamentale assicurare una fornitura adeguata e la massima qualit\u00e0 delle nostre materie prime, e per molte colonne Rxi, il presupposto \u00e8 la realizzazione di questa straordinaria linea di prodotti in silice fusa. I nostri tubi in silice fusa sono trafilati secondo specifiche rigorose e durante il processo di trafilatura applichiamo la nostra resina di poliimmide. Grazie ai numerosi strati di resina migliora la stabilit\u00e0 a temperature elevate e si amplia la gamma di applicazione dei tubi in silice fusa.<\/p>\n\n\n\n<p><strong>Deattivazione:<\/strong>&nbsp;Dopo la trafilatura, un lotto di tubi in silice fusa deve essere deattivato prima di poter diventare una colonna Rxi. La nostra tecnologia di deattivazione superficiale e i nostri processi brevettati schermano efficacemente i silanoli per garantire un\u2019inerzia completa sia per i composti polari sia per gli acidi e le basi, fornendo picchi di forma simmetrica per una maggiore sensibilit\u00e0.<\/p>\n\n\n\n<p><strong>Chimica di fase:<\/strong>&nbsp;Oltre a produrre le nostre materie prime, sviluppiamo anche le nostre fasi stazionarie brevettate. I nostri chimici R&amp;D si occupano delle deattivazioni e delle fasi delle colonne capillari. Qui un team specializzato crea i polimeri ottimizzati con la maggiore selettivit\u00e0 richiesta per le separazioni pi\u00f9 complesse. Ogni fase Rxi forma un legame di tipo cross-link con il tubo di silice fusa deattivato, creando uno strato meccanicamente forte che garantisce un prodotto finale robusto e duraturo. Questa tecnologia di bonding, unica nel suo genere, garantisce un bleeding ridotto per una maggiore sensibilit\u00e0 e tempi di ritenzione riproducibili. Dalle Rxi-5Sil MS, ampiamente utilizzate, alle Rxi-PAH, ideate per applicazioni speciali, le nostre fasi Rxi sono sviluppate e applicate al tuo prodotto finito all\u2019interno del nostro istituto per controllare meglio la qualit\u00e0 e rispondere alle tue esigenze specifiche.<\/p>\n\n\n\n<p><strong>Controllo qualit\u00e0:<\/strong>&nbsp;Tutte le colonne Rxi sono garantite per offrire una riproducibilit\u00e0 affidabile tra una colonna e l\u2019altra e un bleeding ridotto, perch\u00e9 testiamo individualmente ogni colonna relativamente a inerzia, selettivit\u00e0, spessore del film, efficienza, e bleeding \u2014 verificando i risultati in base a rigorose specifiche di controllo qualit\u00e0. Le colonne Rxi non vengono mai testate per lotti. I valori di prestazione fondamentali, quali il bleeding, che otteniamo con i nostri test sono elencati nel rapporto di test cromatografico a corredo della colonna Rxi. Ogni colonna Rxi prodotta nel nostro stabilimento ha dimostrato di soddisfare o superare i requisiti pi\u00f9 rigorosi.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Perch\u00e9 passare alle colonne Rxi?<\/h2>\n\n\n\n<p>Per l\u2019analista oberato di lavoro, con un budget sempre pi\u00f9 ridotto, la migliore colonna GC \u00e8 quella che offre dati affidabili, risultati corretti in breve tempo e tempi di attivit\u00e0 dello strumento ottimizzati.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">DATI AFFIDABILI<\/h3>\n\n\n\n<p>Se i dati non sono affidabili, le conseguenze possono essere gravi. La rivoluzionaria tecnologia Rxi 3-in-1 riunisce la straordinaria inerzia, il bleeding ridotto e l\u2019elevata riproducibilit\u00e0 in un\u2019unica linea di colonne a elevate prestazioni in grado di garantire accuratezza anche a bassi limiti di rilevazione.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><em>Inerzia straordinaria<\/em><\/h4>\n\n\n\n<p>Con la nostra tecnologia 3-in-1 produciamo colonne talmente inerti da poter essere denominate Restek eXtreme Inertness (Rxi). Questa inerzia estrema migliora i rapporti segnale\/rumore e quindi la capacit\u00e0 di identificare e quantificare costantemente i composti in campioni reali. L\u2019inerzia \u00e8 particolarmente importante poich\u00e9 le normative sulle prove prevedono limiti di rilevazione sempre pi\u00f9 bassi dato che molti composti acidi, basici e polari generano picchi scodati se la colonna ha siti attivi (Figura 1). La straordinaria inerzia della tecnologia Rxi risolve questo problema e consente di analizzare una vasta gamma di composti con un\u2019elevata sensibilit\u00e0, spesso su un\u2019unica colonna!<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figura 1:<\/strong>\u00a0Rispetto alle colonne GC tradizionali, le colonne Rxi dimostrano un\u2019inerzia eccellente e producono buone forme del picco per composti critici.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"618\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-GNBR1843A-04-1024x618.jpg\" alt=\"\" class=\"wp-image-21710\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNBR1843A-04-1024x618.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNBR1843A-04-300x181.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNBR1843A-04-768x463.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNBR1843A-04-1536x927.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNBR1843A-04.jpg 1720w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><em>Bleeding ridotto<\/em><\/h4>\n\n\n\n<p>RLe colonne Rxi sono pi\u00f9 stabili rispetto a quelle di altri produttori, quindi generano un bleeding ridotto (Figura 2) e riducono il rumore di fondo, migliorano ulteriormente i rapporti segnale\/rumore, aumentano la sensibilit\u00e0 e riducono i limiti di rilevazione. Grazie a queste qualit\u00e0, le colonne Rxi a bleeding ridotto sono la scelta perfetta per le analisi delle tracce. Inoltre la ridotta contaminazione da bleeding le rende ideali per i sistemi di rilevazione sensibili come la spettrometria di massa (MS), per cui potrai inoltre beneficiare di migliori abbinamenti con le librerie degli spettri di massa.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figura 2:<\/strong>\u00a0Le colonne Rxi hanno il bleeding pi\u00f9 basso tra le colonne dei maggiori brand.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev00822.png\" alt=\"Rxi-5ms columns have the lowest bleed among all major brands of columns.\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV00822<\/p><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rxi-5ms, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/13423?utm_source=chromatograms&amp;utm_medium=link&amp;utm_campaign=GC_EV00822\" rel=\"noopener\">cat.# 13423<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>  1 ng tridecane on-column<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td>split<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>350 &#176;C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>H<sub>2<\/sub><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>FID<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Comparison of 30 m x 0.25 mm ID, 0.25 \u03bcm columns at 330 \u00b0C through 350 \u00b0C.<br \/><\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>13423<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>bleed<\/li><li>rxi<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev00822.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><em>Elevata riproducibilit\u00e0<\/em><\/h4>\n\n\n\n<p>Tempi di ritenzione non prevedibili e picchi non costanti possono causare frustrazione nel migliore dei casi e nel peggiore portare il tuo lavoro a un punto morto. Precisione di fabbricazione senza pari e rigore nel controllo della qualit\u00e0 fanno s\u00ec che in qualsiasi utilizzo, ogni colonna Rxi mantenga le stesse caratteristiche della colonna che andr\u00e0 a sostituire. Superiamo costantemente gli standard industriali in termini di efficienza, ritenzione, bleeding e inerzia (Figura 3).<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figura 3:<\/strong>\u00a0Le colonne Rxi sono progettate e sottoposte a controllo qualit\u00e0 per garantire la riproducibilit\u00e0 tra le varie colonne e i diversi lotti.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev00819.png\" alt=\"Isothermal Test Mix on Rxi-5ms\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV00819<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-4 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,6-Hexanediol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/629-11-8\/1,6-Hexanediol\" target=\"_blank\" rel=\"noopener\">1,6-Hexanediol<\/a><\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Chlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-48-9\/4-Chlorophenol\" target=\"_blank\" rel=\"noopener\">4-Chlorophenol<\/a><\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl nonanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1731-84-6\/Methyl nonanoate\" target=\"_blank\" rel=\"noopener\">Methyl nonanoate<\/a><\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Decylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2016-57-1\/1-Decylamine\" target=\"_blank\" rel=\"noopener\">1-Decylamine<\/a><\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tridecane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/629-50-5\/Tridecane\" target=\"_blank\" rel=\"noopener\">Tridecane<\/a><\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Undecanol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/112-42-5\/1-Undecanol\" target=\"_blank\" rel=\"noopener\">1-Undecanol<\/a><\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/208-96-8\/Acenaphthylene\" target=\"_blank\" rel=\"noopener\">Acenaphthylene<\/a><\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentadecane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/629-62-9\/Pentadecane\" target=\"_blank\" rel=\"noopener\">Pentadecane<\/a><\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rxi-5ms, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/13423?utm_source=chromatograms&amp;utm_medium=link&amp;utm_campaign=GC_EV00819\" rel=\"noopener\">cat.# 13423<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Isothermal column test mix<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Toluene<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>500 \u00b5g\/mL<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1.0 \u00b5L split (split ratio 100:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Gooseneck splitless (4 mm) w\/wool<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>135 &#176;C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>H<sub>2<\/sub>, constant linear velocity<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Linear Velocity:<\/th><td>38 cm\/sec @ 135 \u00b0C<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>FID @ 330 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Liner cat.# 22405 was used to produce this chromatogram, but it has since been discontinued. We recommend cat.# 22406 [or cat.# 23303] as an alternative. For assistance choosing a replacement for this application, contact Restek Technical Service or your local Restek representative.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev00819.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">RISULTATI CORRETTI IN BREVE TEMPO<\/h3>\n\n\n\n<p>Le colonne Rxi consentono di ottenere risultati corretti il pi\u00f9 velocemente possibile. L\u2019inerzia straordinaria genera forme del picco e tempi di ritenzione costanti, consentendo di quantificare in modo preciso gli analiti target anche a basse concentrazioni. L\u2019elevata riproducibilit\u00e0 consente di generare dati che soddisfano i requisiti del metodo, cos\u00ec anche i tuoi clienti otterranno gli stessi risultati veloci e accurati. La stabilit\u00e0 termica con bleeding ridotto della colonna consente di utilizzare lo strumento a temperature di forno pi\u00f9 elevate, riducendo i tempi di analisi e aumentando la produzione di campioni. Inoltre l\u2019efficienza della colonna Rxi permette di ottenere picchi alti e stretti di modo che gli analiti target risultino ancora separati a temperature elevate. Grazie alla combinazione di queste caratteristiche potrai ridurre i tempi di analisi senza pregiudicare la qualit\u00e0 dei dati. Utilizza le colonne Rxi per aumentare la produzione di campioni e la produttivit\u00e0 del laboratorio con analisi rapide e accurate.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figura 4:<\/strong>\u00a0Maggiore efficienza (per es.: pi\u00f9 piatti per metro) significa migliori separazioni su una colonna Rxi.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"311\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-GNBR1843A-02-1024x311.jpg\" alt=\"\" class=\"wp-image-21698\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNBR1843A-02-1024x311.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNBR1843A-02-300x91.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNBR1843A-02-768x233.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNBR1843A-02-1536x466.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNBR1843A-02.jpg 1720w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">TEMPI DI ATTIVITA&#8217; DELLO STRUMENTO OTTIMIZZATI<\/h3>\n\n\n\n<p>Abbiamo sviluppato le colonne Rxi puntando sulla robustezza. I polimeri robusti di Restek sono legati tra loro e fissati a una superficie di deattivazione estremamente inerte, in modo da ottenere una colonna in grado di sopportare condizioni estreme. Questa configurazione inerte e robusta aumenta la durata della colonna e consente di ridurre la frequenza di manutenzione e sostituzione della colonna, i tempi di ricalibrazione dello strumento e la potenziale necessit\u00e0 di rivalidare il metodo rispetto ad altre colonne. Le colonne Rxi sono realizzate per garantire un bleeding ridotto \u2014 anche a temperature di forno GC elevate \u2014 al fine di ridurre il periodo di condizionamento post-installazione e rendere operativo il tuo strumento pi\u00f9 velocemente. Tutte queste caratteristiche aiutano a minimizzare la necessit\u00e0 di manutenzione, ridurre i tempi di inattivit\u00e0 e aumentare la produttivit\u00e0 dello strumento. &nbsp;Con le colonne Rxi otterrai dati migliori, spenderai meno e analizzerai un maggior numero di campioni.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns has-background is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\" style=\"background-color:#e5f7fa\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<h2 class=\"wp-block-heading\">Rxi: la colonna migliore per il tuo prossimo metodo<\/h2>\n\n\n\n<p>La scelta della fase stazionaria corretta \u00e8 di cruciale importanza per la riuscita delle tue analisi.<br>Abbiamo sviluppato un\u2019ampia selezione di fasi stazionarie che coprono tutti gli intervalli di polarit\u00e0, per consentirti di scegliere facilmente la colonna Rxi pi\u00f9 adatta a operare pi\u00f9 velocemente e ottenere risultati imbattibili.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Hai bisogno di aiuto per scegliere la fase Rxi giusta?<\/em><\/h3>\n\n\n\n<p>All&#8217;interno del sito Restek www.restek.com puoi scaricare il poster e la guida alla scelta della colonna. Visita anche la sezione EZGC per inserire il tuo elenco di composti nell\u2019app EZGC, l\u2019unico Chromatogram Modeler del settore, che fornisce consigli personalizzati per migliaia di composti in centinaia di applicazioni.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em><em>Cosa sono le colonne Rxi \u201cSil\u201d?<\/em><\/em><\/h3>\n\n\n\n<p>Combinando l\u2019arilene con la tecnologia Rxi, Restek ha sviluppato un sottogruppo di fasi contenenti copolimeri di silarilene che presentano una stabilit\u00e0 termica ancora pi\u00f9 straordinaria. Queste colonne \u201cSil\u201d &#8211; Rxi-5Sil MS, Rxi-1301Sil MS, Rxi-624Sil MS, Rxi-35Sil MS e Rxi-17Sil MS &#8211; hanno una polarit\u00e0 simile ai modelli tradizionali, ma si differenziano per la selettivit\u00e0. Una maggiore stabilit\u00e0 termica si traduce in un bleeding ridotto, che rende le colonne \u201cSil\u201d Rxi perfette per applicazioni MS o altamente sensibili.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"291\" height=\"648\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNBR1843A-03a.png\" alt=\"\" class=\"wp-image-21700\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNBR1843A-03a.png 291w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNBR1843A-03a-135x300.png 135w\" sizes=\"auto, (max-width: 291px) 100vw, 291px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">INSTALLA OGGI STESSO LE COLONNE Rxi NEL TUO LABORATORIO<\/h2>\n\n\n\n<p>Il tuo operato aiuta a garantire la sicurezza degli alimenti e dell\u2019ambiente, la qualit\u00e0 del carburante e dei medicinali, la giustizia nel sistema legale e tanto altro ancora. Con tutta questa responsabilit\u00e0, ti meriti di scegliere la migliore colonna GC per il tuo strumento. Visita il sito www.restek.com per scoprire maggiori dettagli sul perch\u00e9 le colonne Rxi e Restek Pure Chromatography sono la scelta ottimale per migliorare la velocit\u00e0 e l\u2019accuratezza dei risultati e ordina i tuoi prodotti oggi stesso!<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-16018d1d wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-background wp-element-button\" href=\"https:\/\/www.restek.com\/global\/it\/search?Ntt=rxi&amp;Ns=bestMatch\" style=\"background-color:#f67f01;padding-right:70px;padding-left:70px\" target=\"_blank\" rel=\"noopener\"><strong><strong>Rxi<br>Prodotti<\/strong><\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-16018d1d wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-background wp-element-button\" href=\"https:\/\/www.restek.com\/global\/it\/resource-hub-search?s=rxi\" style=\"background-color:#f67f01;padding-right:50px;padding-left:50px\" target=\"_blank\" rel=\"noopener\"><strong><strong>Rxi<br>Letteratura tecnica<\/strong><\/strong><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-16018d1d wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-background wp-element-button\" href=\"https:\/\/www.restek.com\/global\/it\/chromatogram-library?s=rxi\" style=\"background-color:#f67f01;padding-right:50px;padding-left:50px\" target=\"_blank\" rel=\"noopener\"><strong><strong>Rxi<br>Cromatogrammi<\/strong><\/strong><\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>La famiglia di colonne GC Rxi di Restek ti aiuta a risolvere le difficili sfide analitiche di tutti i giorni, fornendoti inerzia e durata al top, stabilit\u00e0 e riproducibilit\u00e0, cos\u00ec come spurgo e forma dei picchi.<\/p>\n","protected":false},"author":11,"featured_media":7207,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[788],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2528,2516],"resource-technique":[2332],"ppma_author":[414],"class_list":["post-43708","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articoli","product-library-colonne-gc","product-library-prodotti-per-gascromatografia","resource-technique-gascromatografia-gc"],"acf":[],"taxonomy_info":{"category":[{"value":788,"label":"Articoli"}],"product-library":[{"value":2528,"label":"Colonne GC"},{"value":2516,"label":"Prodotti per Gascromatografia"}],"resource-technique":[{"value":2332,"label":"Gascromatografia (GC)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNBR1843-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/it\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":788,"name":"Articoli","slug":"articoli","term_group":0,"term_taxonomy_id":788,"taxonomy":"category","description":"","parent":0,"count":469,"filter":"raw","cat_ID":788,"category_count":469,"category_description":"","cat_name":"Articoli","category_nicename":"articoli","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43708","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=43708"}],"version-history":[{"count":19,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43708\/revisions"}],"predecessor-version":[{"id":76065,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43708\/revisions\/76065"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media\/7207"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=43708"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=43708"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=43708"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=43708"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=43708"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=43708"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=43708"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=43708"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=43708"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}