{"id":43736,"date":"2020-10-12T00:00:00","date_gmt":"2020-10-12T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/faster-gc-tactics-five-ways-to-speed-up-gas-chromatography-analyses-using-your-current-system\/"},"modified":"2026-02-05T20:33:17","modified_gmt":"2026-02-05T20:33:17","slug":"faster-gc-tactics-five-ways-to-speed-up-gas-chromatography-analyses-using-your-current-system","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/articles\/gnot3364\/faster-gc-tactics-five-ways-to-speed-up-gas-chromatography-analyses-using-your-current-system","title":{"rendered":"Faster (GC) Tactics: Five ways to speed up gas chromatography analyses using your current system"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>Author<\/strong>: Jaap de Zeeuw<br>Restek Corporation<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Published By<\/strong>: The Analytical Scientist<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Issue<\/strong>: 36<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Year of Publication<\/strong>: 2016<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Link<\/strong>:&nbsp;<a href=\"https:\/\/theanalyticalscientist.com\/techniques-tools\/faster-gc-tactics\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/theanalyticalscientist.com\/techniques-tools\/faster-gc-tactics<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>For the full issue, visit: <\/strong><a href=\"https:\/\/theanalyticalscientist.com\/media\/pk1lpip1\/tas_issue-0216.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/theanalyticalscientist.com\/media\/pk1lpip1\/tas_issue-0216.pdf<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Abstract<\/strong>:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Reducing analysis time is a constant priority. And it\u2019s sensible because it cuts costs per analysis and you get faster results. Here, I\u2019d like to share some clever ways to reduce gas chromatography (GC) analysis time using existing instrumentation in two real-world situations.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Reducing analysis time is a constant priority. And it\u2019s sensible because it cuts costs per analysis and you get faster results. Here, I\u2019d like to share some clever ways to reduce gas chromatography (GC) analysis time using existing instrumentation in two real-world situations.<\/p>\n","protected":false},"author":19,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[7],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[568],"product-library":[2385,2372,2384,2387,2389],"resource-technique":[2294],"ppma_author":[439],"class_list":["post-43736","post","type-post","status-publish","format-standard","hentry","category-articles","resource-type-third-party-peer-reviewed-publications","product-library-ferrules-fittings-connectors","product-library-gas-chromatography-products","product-library-gc-columns","product-library-instrument-supplies-tools","product-library-tubing-regulators","resource-technique-gas-chromatography-gc"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"}],"resource-type":[{"value":568,"label":"Third-Party &amp; Peer Reviewed Publications"}],"product-library":[{"value":2385,"label":"Ferrules, Fittings, Connectors"},{"value":2372,"label":"Gas Chromatography Products"},{"value":2384,"label":"GC Columns"},{"value":2387,"label":"Instrument Supplies &amp; Tools"},{"value":2389,"label":"Tubing &amp; Regulators"}],"resource-technique":[{"value":2294,"label":"Gas Chromatography (GC)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jaap de Zeeuw","author_link":"https:\/\/discover.restek.com\/it\/author\/jaap-de-zeeuw\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":7,"category_count":510,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":439,"user_id":19,"is_guest":0,"slug":"jaap-de-zeeuw","display_name":"Jaap de Zeeuw","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-de-zeeuw-jaap.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-de-zeeuw-jaap.jpg"},"author_category":"1","first_name":"Jaap","last_name":"de Zeeuw","user_url":"https:\/\/www.linkedin.com\/in\/jaap-de-zeeuw-ba102a7\/","job_title":"GC Consultant","description":"Jaap is a world-renowned chromatographer with over 40 years of experience, including 15 years with Restek and 27 years with Varian\/Chrompack prior to joining Restek. Throughout his career, Jaap has focused the chromatographic challenges of industrial analysis. For his 1979 graduation from The Institute for Higher Education, where he specialized in chemistry, Jaap authored a paper titled \"The Challenge of Coating Flexible Fused Silica Capillary Columns\" and has since distinguished himself as an authority on the subject. Jaap has been directly involved with the creation of numerous chemically bonded columns, including the first bonded PEG column and the stabilized PLOT columns widely used in the petrochemical arena. He has also helped develop new techniques, such as fast GC-MS using vacuum GC technology (low-pressure GC or LPGC). Over his innovative career, he has filed several patents for his work. Based out of the Netherlands, Jaap is extensively published and regularly travels internationally to share his knowledge. After retiring from Restek, Jaap founded CreaVisions, where he works as a GC Consultant and teaches master classes on key GC topics as well as on creativity in science."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43736","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/19"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=43736"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43736\/revisions"}],"predecessor-version":[{"id":87100,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43736\/revisions\/87100"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=43736"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=43736"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=43736"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=43736"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=43736"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=43736"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=43736"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=43736"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=43736"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}