{"id":43754,"date":"2020-10-21T00:00:00","date_gmt":"2020-10-21T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/vial-septum-selection-guide\/"},"modified":"2025-11-26T20:14:46","modified_gmt":"2025-11-26T20:14:46","slug":"vial-septum-selection-guide","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/articles\/gnot3420\/vial-septum-selection-guide","title":{"rendered":"Vial Septum Selection Guide"},"content":{"rendered":"<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr style=\"background-color: #f5f8f8;\">\n<th>Materials<\/th>\n<th>Compatability<\/th>\n<th>Incompatibility<\/th>\n<th>Resealability<\/th>\n<th>Max. Temp.<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Red Rubber (synthetic)<\/td>\n<td>acetone, alcohols, DMF, DMSO, ether<\/td>\n<td>ACN, benzene, chloroform, heptane, hexane, pyridine, THF, toluene<\/td>\n<td>very good<\/td>\n<td>90\u00b0<\/td>\n<\/tr>\n<tr>\n<td>PTFE\/Natural Rubber<\/td>\n<td><strong>PTFE:<\/strong>\u00a0resistance until punctured<br \/><strong>Rubber:<\/strong>\u00a0acetone, ACN, alcohols, diethylamine, DMF, DMSO, phenol<\/td>\n<td>aromatics, carbon disulfide, chlorinated solvents, hydrocarbon solvents<\/td>\n<td>very good<\/td>\n<td>90\u00b0<\/td>\n<\/tr>\n<tr>\n<td>PTFE\/Silicone<br \/>PTFE\/Silicone\/PTFE<\/td>\n<td><strong>PTFE:<\/strong>\u00a0resistance until punctured<br \/><strong>Silicone:<\/strong>\u00a0acetone, alcohols, DMF, DMSO, ether<\/td>\n<td>ACN, benzene, chloroform, heptane, hexane, pyridine, THF, toluene<\/td>\n<td>very good<\/td>\n<td>205\u00b0<\/td>\n<\/tr>\n<tr>\n<td>Polyethylene<\/td>\n<td>Good resistance to solvents and weak acids or bases. Unreactive with most chemicals, but some solvents cause softening or swelling.<\/td>\n<td>hydrocarbon solvents<\/td>\n<td>one-time use<\/td>\n<td>175\u00b0<\/td>\n<\/tr>\n<tr>\n<td>Gray Chlorobutyl<\/td>\n<td>acids or bases, water solutions, buffer solutions, oxygenated solvents, vegetable oils<\/td>\n<td>aliphatic or aromatic hydrocarbons, halogenated solvents, mineral oils, strong acids<\/td>\n<td>very good<\/td>\n<td>100\u00b0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<p class=\"wp-block-paragraph\">Abbreviations:<br>ACN &#8211; acetonitrile<br>DMF &#8211; dimethylformamide<br>DMSO &#8211; dimethylsulfoxide<br>THF &#8211; tetrahydrofuran<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>NOTE:&nbsp;<\/strong>This chemical resistance chart is intended only as a guideline. It does not cover all compounds or all solvents. Tests were done at room temperature on pure solvents, and there is no data if two or more compounds are involved. Always confirm the compatibility of your vial, closure, and chemical combination prior to sample preparations.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Select the right vial septum material based on solvent compatibility and incompatibility, resealability, and maximum temperature.<\/p>\n","protected":false},"author":11,"featured_media":22330,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[7],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[567],"product-library":[2375,2405],"resource-technique":[2294,2299],"ppma_author":[414],"class_list":["post-43754","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles","resource-type-selection-guides","product-library-sample-preparation-products","product-library-vials-accessories","resource-technique-gas-chromatography-gc","resource-technique-liquid-chromatography"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"}],"resource-type":[{"value":567,"label":"Selection Guides"}],"product-library":[{"value":2375,"label":"Sample Preparation Products"},{"value":2405,"label":"Vials &amp; Accessories"}],"resource-technique":[{"value":2294,"label":"Gas Chromatography (GC)"},{"value":2299,"label":"Liquid Chromatography"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3420-01.jpg",350,155,false],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/it\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":509,"filter":"raw","cat_ID":7,"category_count":509,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43754","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=43754"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43754\/revisions"}],"predecessor-version":[{"id":59736,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43754\/revisions\/59736"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media\/22330"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=43754"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=43754"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=43754"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=43754"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=43754"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=43754"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=43754"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=43754"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=43754"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}