{"id":43785,"date":"2025-01-20T00:00:00","date_gmt":"2025-01-20T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/thermally-stable-and-polar-zwitterionic-liquid-stationary-phases-for-gas-chromatography-understanding-the-impact-of-chemical-structure\/"},"modified":"2025-11-04T15:31:44","modified_gmt":"2025-11-04T15:31:44","slug":"thermally-stable-and-polar-zwitterionic-liquid-stationary-phases-for-gas-chromatography-understanding-the-impact-of-chemical-structure","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/articles-ja\/gnot4427\/thermally-stable-and-polar-zwitterionic-liquid-stationary-phases-for-gas-chromatography-understanding-the-impact-of-chemical-structure","title":{"rendered":"Thermally Stable and Polar Zwitterionic Liquid Stationary Phases for Gas Chromatography: Understanding the Impact of Chemical Structure"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>Author(s):<\/strong> Victoria R. Zeger<sup>1<\/sup>, Bhawana Thapa<sup>1<\/sup>, Jessica F. DeLair<sup>1<\/sup>, Jared L. Anderson<sup>1<\/sup>, David S. Bell<sup>2<\/sup>, Daniel Shollenberger<sup>3<\/sup>, Moubani Chakraborty<sup>3<\/sup>, Jason S. Herrington<sup>3<\/sup><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">1. Department of Chemistry, Iowa State University, Ames, IA 50011, USA, 2. ASKkPrime LLC, Bellefonte, PA, 16823, USA, 3. Restek Corporation<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Published By:<\/strong> Journal of Chromatography A<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Volume:<\/strong> 1740<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Year of Publication:<\/strong> 2015<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Link:<\/strong> <a href=\"https:\/\/doi.org\/10.1016\/j.chroma.2024.465594\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1016\/j.chroma.2024.465594<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Abstract:<\/strong> The chemical structure of nine imidazolium sulfonate and triflimide zwitterionic liquids (ZILs) were systematically tuned to increase their thermal stability for gas chromatography (GC) separations. Substituents for imidazolium and 2-phenylimidazolium cation systems, comprised of alkyl, benzyl, and oligoether groups of varying chain lengths, were studied as stationary phases in GC. Propanesulfonate, ethanesulfonate, and propanetriflimide anions were examined to understand the effect of linker length and nucleophilicity on ZIL thermal stability. Studies were conducted to assess film stability and thermal lability of ZIL stationary phases on fused silica capillaries when exposed to elevated temperatures for prolonged time periods. All stationary phases exhibited relatively poor film stability on untreated capillary surfaces, but most showed repeatable chromatographic retention after stepwise heating from 100 to 200 \u00b0C. To understand the thermal degradation pathways of the ZILs, mass spectrometry (MS) was used to monitor the degradation\/volatilization of the stationary phase when heated from 40 to 250 \u00b0C. Salt-deactivated surfaces were effective at mitigating stationary phase instability, but were observed to participate in the degradation of alkyl functionalized ZILs via nucleophilic attack of the alkyl substituent. This was not observed for oligoether substituted ZILs. Imidazolium propanesulfonate ZILs all underwent degradation through the detachment of the anion system, resulting in the reformation of 1,3-propanesultone. Most ZIL stationary phases degraded below 230 \u00b0C, but the cation substituent was observed to play a significant role in overall ZIL thermal stability. For the imidazolium propanetriflimide ZIL, degradation of the anion system occurred prior to the detachment of the entire anion system via elimination and occurred at around 245 \u00b0C.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>The chemical structure of nine imidazolium sulfonate and triflimide zwitterionic liquids (ZILs) were systematically tuned to increase their thermal stability for gas chromatography (GC) separations.<\/p>\n","protected":false},"author":25,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[568],"product-library":[2552],"resource-technique":[2340,2345],"ppma_author":[765,659,695,693,671,668,721,445],"class_list":["post-43785","post","type-post","status-publish","format-standard","hentry","category-articles-ja","resource-type-third-party-peer-reviewed-publications","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja","resource-technique-mass-spectrometry-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"resource-type":[{"value":568,"label":"Third-Party &amp; Peer Reviewed Publications"}],"product-library":[{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2345,"label":"\u8cea\u91cf\u5206\u6790 (MS)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jason S. Herrington, PhD","author_link":"https:\/\/discover.restek.com\/it\/author\/jason-s-herrington-phd\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":765,"user_id":0,"is_guest":1,"slug":"victoria-r-zeger","display_name":"Victoria R. Zeger","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Victoria R.","last_name":"Zeger","user_url":"","job_title":"","description":"Department of Chemistry, Iowa State University, Ames, IA 50011, USA"},{"term_id":659,"user_id":0,"is_guest":1,"slug":"bhawana-thapa","display_name":"Bhawana Thapa","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Bhawana","last_name":"Thapa","user_url":"","job_title":"","description":"Department of Chemistry, Iowa State University, Ames, IA 50011, USA"},{"term_id":695,"user_id":0,"is_guest":1,"slug":"jessica-f-delair","display_name":"Jessica F. DeLair","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Jessica F.","last_name":"DeLair","user_url":"","job_title":"","description":"Department of Chemistry, Iowa State University, Ames, IA 50011, USA"},{"term_id":693,"user_id":0,"is_guest":1,"slug":"jared-l-anderson","display_name":"Jared L. Anderson","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Jared L.","last_name":"Anderson","user_url":"","job_title":"","description":"Department of Chemistry, Iowa State University, Ames, IA 50011, USA"},{"term_id":671,"user_id":0,"is_guest":1,"slug":"david-s-bell","display_name":"David S. Bell","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"David S.","last_name":"Bell","user_url":"","job_title":"","description":"ASKkPrime LLC, Bellefonte, PA, 16823, USA. Restek"},{"term_id":668,"user_id":0,"is_guest":1,"slug":"daniel-shollenberger","display_name":"Daniel Shollenberger","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Daniel","last_name":"Shollenberger","user_url":"","job_title":"","description":""},{"term_id":721,"user_id":0,"is_guest":1,"slug":"moubani-chakraborty","display_name":"Moubani Chakraborty","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Moubani","last_name":"Chakraborty","user_url":"","job_title":"","description":""},{"term_id":445,"user_id":25,"is_guest":0,"slug":"jason-s-herrington-phd","display_name":"Jason S. Herrington, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-herrington-jason.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-herrington-jason.png"},"author_category":"1","first_name":"Jason","last_name":"Herrington","user_url":"https:\/\/www.linkedin.com\/in\/jason-herrington-97b0b620\/%20","job_title":"VP, Reference Standards Business","description":"Jason joined Restek in 2011 after spending over 10 years in environmental analysis, most notably as a postdoctoral research fellow with the U.S. EPA focusing on the development of techniques for organic speciation of ambient gas-phase and particulate air toxics. He has a BS in environmental sciences from Rutgers University and a PhD in exposure science from The University of Medicine and Dentistry of New Jersey. His wide-ranging work has been published in over a dozen peer-reviewed manuscripts and presented around the world. As a senior scientist with Restek, Jason is heavily involved with developing new air products and applications."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43785","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/25"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=43785"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43785\/revisions"}],"predecessor-version":[{"id":60059,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/43785\/revisions\/60059"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=43785"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=43785"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=43785"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=43785"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=43785"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=43785"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=43785"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=43785"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=43785"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}