{"id":48513,"date":"2025-04-15T00:00:00","date_gmt":"2025-04-15T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/inert-lc-columns-the-answer-to-poor-thc-sensitivity\/"},"modified":"2026-05-26T18:56:35","modified_gmt":"2026-05-26T18:56:35","slug":"inert-lc-columns-the-answer-to-poor-thc-sensitivity","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/blogs\/gnbl4715\/inert-lc-columns-the-answer-to-poor-thc-sensitivity","title":{"rendered":"Inert LC Columns\u2014The Answer to Poor THC Sensitivity?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Whole blood toxicology analysis of cannabinoids by LC-MS\/MS is difficult for several reasons, but one of the biggest challenges is achieving the low detection limits needed to meet reporting guidelines. Most forensic laboratories strive to achieve a limit of quantitation (LOQ) of at least 0.5 ng\/mL for \u03949-tetrahydrocannabinol (\u03949-THC); 11-hydroxy-\u03949-tetrahydrocannabinol (11-OH-\u03949-THC); and 11-nor-9-carboxy-\u0394-9-THC (\u03949-THC-COOH), which are the analytes typically tested for to determine cannabis use. Achieving these low detection limits can be challenging, especially for instrument platforms that are older and less sensitive. If you\u2019ve already tried all the usual tricks to squeeze a little more sensitivity out of your method, you might consider trying an inert LC column.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Inert LC columns are just like our traditional stainless-steel <a href=\"https:\/\/www.restek.com\/c\/1119\" target=\"_blank\" rel=\"noopener\">LC columns<\/a>, but with an inert coating applied to the surface. This coating helps to prevent nonspecific binding for analytes that chelate, or stick, to metal surfaces. Chelation can cause poor peak shapes or a loss of analyte that negatively impacts sensitivity. Not all compounds will experience nonspecific binding\/chelation, though acidic compounds may be more prone to it.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Although not all analytes will see a difference from the use of an inert column, it can lead to an improvement in sensitivity for those that do. In the following experiment, we compared an inert LC column and traditional stainless-steel column for the analysis of cannabinoids in whole blood. &nbsp;The developed method uses a Raptor FluoroPhenyl stationary phase to separate \u03948-THC; \u03949-THC; and their hydroxy and carboxy metabolites. To determine if an inert column would be beneficial for this analysis, a sample containing the analytes of interest was run on the method using both a Raptor Inert FluoroPhenyl column and a standard Raptor FluoroPhenyl column. The results are shown below.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> Comparison of \u03949-THC; \u03948-THC; and Metabolites on Raptor FluoroPhenyl vs. Raptor Inert FluoroPhenyl<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0829.png\" alt=\"Comparison of \u03949-THC; \u03948-THC; and Metabolites on Raptor FluoroPhenyl vs. Raptor Inert FluroPhenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0829<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor<\/th><th style=\"text-align: center;width: 75px\">Product 1<\/th><th style=\"text-align: center;width: 75px\">Product 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 11-OH-\u03948-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/28646-40-4\/11-OH-\u03948-THC\" target=\"_blank\" rel=\"noopener\">11-OH-\u03948-THC<\/a><\/td><td class=\"oth\">100<\/td><td class=\"oth\">331.0<\/td><td class=\"oth\">313.0<\/td><td class=\"oth\">201.1<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 11-OH-\u03949-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/34675-49-5\/11-OH-\u03949-THC\" target=\"_blank\" rel=\"noopener\">11-OH-\u03949-THC<\/a><\/td><td class=\"oth\">100<\/td><td class=\"oth\">331.0<\/td><td class=\"oth\">313.0<\/td><td class=\"oth\">201.1<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03948-THC-COOH\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/39690-06-7\/\u03948-THC-COOH\" target=\"_blank\" rel=\"noopener\">\u03948-THC-COOH<\/a><\/td><td class=\"oth\">500<\/td><td class=\"oth\">345.1<\/td><td class=\"oth\">327.0<\/td><td class=\"oth\">299.2<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03949-THC-COOH\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56354-06-4\/\u03949-THC-COOH\" target=\"_blank\" rel=\"noopener\">\u03949-THC-COOH<\/a><\/td><td class=\"oth\">500<\/td><td class=\"oth\">345.1<\/td><td class=\"oth\">327.0<\/td><td class=\"oth\">299.2<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03948-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5957-75-5\/\u03948-THC\" target=\"_blank\" rel=\"noopener\">\u03948-THC<\/a><\/td><td class=\"oth\">100<\/td><td class=\"oth\">315.0<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.2<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03949-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1972-08-3\/\u03949-THC\" target=\"_blank\" rel=\"noopener\">\u03949-THC<\/a><\/td><td class=\"oth\">100<\/td><td class=\"oth\">315.0<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.2<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>See notes.<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 3 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>\u03948-Tetrahydrocannabinol (\u03948-THC) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34090\" rel=\"noopener\">cat.# 34090<\/a>)<\/td><\/tr><tr><td><\/td><td>\u03949-Tetrahydrocannabinol (\u03949-THC) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34067\" rel=\"noopener\">cat.# 34067<\/a>)<\/td><\/tr><tr><td><\/td><td>(\u00b1)11-nor-9-carboxy-\u0394-9-THC (\u03949-THC-COOH) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34068\" rel=\"noopener\">cat.# 34068<\/a>)<\/td><\/tr><tr><td><\/td><td>Other compounds obtained separately. <\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>40:60 Water:methanol, both with 0.1% formic acid (v\/v)<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 0.1% formic acid <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol, 0.1% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.8<\/td><td>36<\/td><td>64<\/td><\/tr><tr><td>6.50<\/td><td>0.8<\/td><td>36<\/td><td>64<\/td><\/tr><tr><td>6.60<\/td><td>0.8<\/td><td>32<\/td><td>68<\/td><\/tr><tr><td>13.00<\/td><td>0.8<\/td><td>32<\/td><td>68<\/td><\/tr><tr><td>13.10<\/td><td>0.8<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>14.00<\/td><td>0.8<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>14.10<\/td><td>0.8<\/td><td>36<\/td><td>64<\/td><\/tr><tr><td>16.00<\/td><td>0.8<\/td><td>36<\/td><td>64<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Max Pressure:<\/th><td>390 bar<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Shimadzu 8045 MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Shimadzu Nexera X2<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Five hundred microliters of whole blood was transferred to a 12 mL glass test tube. Fifty microliters of internal standard and 50 \u00b5L of control material were transferred to the test tube and vortexed. Five hundred microliters of HPLC grade water was added to each sample and vortexed. One hundred microliters of 10% acetic acid was added to each sample and vortexed. Two and a half milliliters of 80:20 hexanes:ethyl acetate was added to each sample and vortexed until visibly combined. Samples were centrifuged at 2800 rpm for 15 minutes. The top layer was transferred to a new glass test tube and dried down under nitrogen. Samples were reconstituted with 100 \u00b5L of 40:60 methanol:water, both containing 0.1% formic acid, and vortexed. Samples were transferred to 2 mL screw-thread vials (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21143\" rel=\"noopener\">cat.# 21143<\/a>) with glass inserts (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21776\" rel=\"noopener\">cat.# 21776<\/a>) and capped with short-cap, screw-vial closures (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/24498\" rel=\"noopener\">cat.# 24498<\/a>).<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>The column was stored in 100% acetonitrile when not in use. <br \/><br \/>Columns are:<br \/><br \/>Raptor Inert FluoroPhenyl (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9319A1E-T\" rel=\"noopener\">cat.# 9319A1E-T<\/a>)<br \/>Raptor FluoroPhenyl (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9319A1E\" rel=\"noopener\">cat.# 9319A1E<\/a>)<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34090<\/li><li>34067<\/li><li>34068<\/li><li>9319A1E<\/li><li>21143<\/li><li>21776<\/li><li>24498<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>cannabinoids<\/li><li>fluorophenyl<\/li><li>inert<\/li><li>isomers<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0829.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Looking at these results, we can see that all six analytes had some increase in peak height and area when using the inert column. The parent compounds saw little increase in peak height\/areas (2-7%), while the hydroxy metabolites had a more substantial increase (17-27%), and the carboxy metabolites had the most significant change (31-39%) when analyzed on an inert column. The carboxy compounds likely see the largest increase in sensitivity because of their carboxylic acid functional group, which is more prone to nonspecific binding. The hydroxy and parent compounds are more neutral, so they are less affected using an inert column. Nonetheless, we do see increased sensitivity for these cannabinoids when they are analyzed on an inert column.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If you are struggling to meet the low detection limits needed for cannabinoid analysis in whole blood, an inert LC column might be just what you need. If you\u2019re interested in analyzing THC isomers in biological fluids, make sure you check out <a href=\"https:\/\/discover.restek.com\/application-notes\/cfan4420\/lc-ms-ms-analysis-of-thc-isomers-and-metabolites-in-whole-blood-and-urine\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/application-notes\/cfan4420\/lc-ms-ms-analysis-of-thc-isomers-and-metabolites-in-whole-blood-and-urine\">LC-MS\/MS Analysis of THC Isomers &amp; Metabolites in Whole Blood and Urine<\/a> to learn more about our complete workflow solutions for this topic.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Prodotti Menzionati<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A1E-T\">                                N\u00b0 Catalogo 9319A1E-T                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Colonna HPLC Raptor Inert Fluorofenile, 2,7 \u00b5m, 100 x 3,0 mm<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A1E-T\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A1E\">                                N\u00b0 Catalogo 9319A1E                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Colonna HPLC Raptor fluorofenilica, 2,7 \u00b5m, 100 x 3,0 mm<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A1E\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34090\">                                N\u00b0 Catalogo 34090                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">d8-tetraidrocannabinolo (d8-THC), 1000 \u00b5g\/mL in Metanolo P&amp;T, 1 ml\/ampolla<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34090\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34067\">                                N\u00b0 Catalogo 34067                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">d9-tetraidrocannabinolo (d9-THC), 1000 \u00b5g\/mL in Metanolo P&amp;T, 1 ml\/ampolla<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34067\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34068\">                                N\u00b0 Catalogo 34068                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">(\u00b1)11-nor-9-carbossi-D9-THC, 100 \u00b5g\/mL in Metanolo, 1 ml\/ampolla<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34068\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21143\">                                N\u00b0 Catalogo 21143                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Vial con tappo corto con indicatore graduato, filettatura 9-425, 2,0 mL, 9 mm, 12 x 32 (solo vial), ambrato, 1000 pz.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21143\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21776\">                                N\u00b0 Catalogo 21776                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Inserti per vial, vetro, bocca larga con molla sul fondo, 250 \u00b5L, 100 pz.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21776\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24498\">                                N\u00b0 Catalogo 24498                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Tappi corti a vite, polipropilene, filettatura, setti in PTFE\/silicone\/PTFE, blu, preassemblati, 2,0 mL, 9 mm, 1000 pz.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24498\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Struggling with poor sensitivity for THC and its metabolites? This blog explores how using columns with inert hardware increased peak area up to 39% and peak height up to 32% compared to standard stainless-steel columns.<\/p>\n","protected":false},"author":13,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[],"industries-application":[2281,2243],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2334,2364],"ppma_author":[432],"class_list":["post-48513","post","type-post","status-publish","format-standard","hentry","category-blogs","industries-application-cannabis-it","industries-application-cannabis-terapeutica-ricreativa","resource-technique-cromatografia-liquida-lc","resource-technique-ms-ms-it"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}],"industries-application":[{"value":2281,"label":"Cannabis"},{"value":2243,"label":"Cannabis Terapeutica o Ricreativa"}],"resource-technique":[{"value":2334,"label":"Cromatografia Liquida (LC)"},{"value":2364,"label":"MS\/MS"}]},"featured_image_src_large":false,"author_info":{"display_name":"Haley Berkland, MS","author_link":"https:\/\/discover.restek.com\/it\/author\/haley-berkland-ms\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":9,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":432,"user_id":13,"is_guest":0,"slug":"haley-berkland-ms","display_name":"Haley Berkland, MS","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg"},"author_category":"1","first_name":"Haley","last_name":"Berkland","user_url":"https:\/\/www.linkedin.com\/in\/haley-berkland-60b66517b\/","job_title":"LC Applications Scientist","description":"Haley is an LC applications scientist at Restek. She attended Duquesne University, receiving her bachelor's degree in biochemistry and a master's degree in forensic science and law. As a graduate student, she performed research on the detection of drugs of abuse in vitreous humor by LC-MS\/MS. Before joining Restek in 2023, Haley spent four years working as a forensic toxicologist. While in this role, she performed analysis of postmortem toxicology casework, identification of seized drug evidence, and development\/validation of new assays by LC-MS\/MS, GC-MS, and GC-FID."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/48513","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=48513"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/48513\/revisions"}],"predecessor-version":[{"id":95564,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/48513\/revisions\/95564"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=48513"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=48513"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=48513"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=48513"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=48513"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=48513"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=48513"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=48513"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=48513"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}