{"id":51596,"date":"2019-07-02T14:30:00","date_gmt":"2019-07-02T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/a-hoppy-little-story\/"},"modified":"2025-10-28T15:17:07","modified_gmt":"2025-10-28T15:17:07","slug":"a-hoppy-little-story","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/blogs\/gnbl4568\/a-hoppy-little-story","title":{"rendered":"A Hoppy Little Story"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Now that we\u2019re getting into the warmer months of the year, you\u2019re probably starting to see pop-up beer gardens or people outside relaxing with a nice cold one. Since the beer industry has been evolving and people are enjoying craft beers more and more, there are tons of unique brews on the market. If you are not a beer connoisseur, then you may not know what gives your favorite India pale ale or summer lager its intriguing characteristics. The ingredient responsible for the bitterness and much of the aroma are the hops. There are an incredible number of different hop varieties and every single variety has its own personal profile! Some common U.S. hop varieties include Cascade, Centennial, Citra, and Nugget. But, you may be asking yourself, \u201cwhat makes these hop varieties so different?\u201d TERPENES! Terpenes are a class of organic compounds that are comprised of isoprene units and they are what give hops their unique aroma and flavor profiles. There are many different classes of terpenes, but the classes that we are interested in are the mono- and sesquiterpenes, which include limonene, humulene, pinene, myrcene, to name a few.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"250\" height=\"250\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-hoppy-little-story-01.png\" alt=\"limonene structure\" class=\"wp-image-12538\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-hoppy-little-story-01.png 250w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-hoppy-little-story-01-150x150.png 150w\" sizes=\"auto, (max-width: 250px) 100vw, 250px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Limonene &#8211; http:\/\/www.chemspider.com\/Chemical-Structure.20939.html<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Since I have an interest in quality craft beers, I wanted to dive into a variety and look for some terpenes. Luckily for me, a friend of mine in Restek\u2019s reference standard department grows his own hops. Thanks, Joe! When these hops were harvested last year, Joe vacuum packed me his finest Hallertau variety.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"613\" height=\"460\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-hoppy-little-story-02.jpg\" alt=\"ground hops\" class=\"wp-image-12544\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-hoppy-little-story-02.jpg 613w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-hoppy-little-story-02-300x225.jpg 300w\" sizes=\"auto, (max-width: 613px) 100vw, 613px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Ground Hops<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The hops were added to a Blixer processor with dry ice and then ground into a very fine powder. 0.5 g of the hop powder was measured into a 50 mL QuEChERS tube (cat#&nbsp;25846), followed by 10 mL of isopropanol. The mixture was vortexed for 5 seconds, then sonicated for 5 minutes, repeated three times. 1 mL of the supernatant was filtered using a 13 mm, 0.22 \u00b5m, PTFE syringe filter (cat#&nbsp;26142) and added to a 20 mL headspace (HS) vial (cat#&nbsp;24685). 19 mL of RO water was then added to the 20 mL HS vial, which was then capped and ready for analysis. Further sample preparation included the CTC PAL RTC rail system, where samples were analyzed via solid phase microextraction (SPME), using direct immersion (DI), with gas chromatography-mass spectrometry. A divinylbenzene (DVB) SPME-Arrow (cat#&nbsp;27486) was used for this SPME Arrow-DI-GC-MS method.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-hoppy-little-story-03.png\" alt=\"blog-hoppy-little-story.png\" title=\"-\"><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1018\" height=\"415\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-hoppy-little-story-04.jpg\" alt=\"total ion chromatogram of terpenes in hops\" class=\"wp-image-12556\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-hoppy-little-story-04.jpg 1018w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-hoppy-little-story-04-300x122.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-hoppy-little-story-04-768x313.jpg 768w\" sizes=\"auto, (max-width: 1018px) 100vw, 1018px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Total Ion Chromatogram of Terpenes in Hops<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Using Restek\u2019s Terpene Mix 1 &amp; 2 (cat#&nbsp;34095&nbsp;&amp;&nbsp;34096), we were setup to identify 23 different terpenes. After normalizing the responses for terpenes to 100% we were able to gather a nice breakdown of the terpene profile for Joe\u2019s Hallertau. Using the NIST mass spectral database, we were also able to identify several other terpenes (i.e. beta-Phellandrene), but these were not added to the pie chart.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-hoppy-little-story-05.png\" alt=\"\" class=\"wp-image-60760\" title=\"-\"><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">So, the next time you\u2019re enjoying a cold one on a hot summer day, give it a good sniff to get an idea of what terpenes may be in there. Every beer has its own unique hoppy little story to tell! Cheers!<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-hoppy-little-story-06-1024x683.jpg\" alt=\"two beer bottles being clinked together\" class=\"wp-image-12568\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-hoppy-little-story-06-1024x683.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-hoppy-little-story-06-300x200.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-hoppy-little-story-06-768x512.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-hoppy-little-story-06-1536x1024.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-hoppy-little-story-06-2048x1365.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Photo courtesy of Wil Stewart<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Prodotti Menzionati<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25846\">                                N\u00b0 Catalogo 25846                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Provette da centrifuga vuote da 50 ml, Polipropilene con tappo, 50 provette, 50-conf.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25846\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26142\">                                N\u00b0 Catalogo 26142                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Filtro siringa da 13 mm, 0,22 \u00b5m, PTFE, bianco, 100 pz.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26142\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24685\">                                N\u00b0 Catalogo 24685                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Vial con bocca crimp per spazio di testa, 20 mm, 20 mL, fondo piatto, trasparenti, 100 pz.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24685\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34095\">                                N\u00b0 Catalogo 34095                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Standard 1 terpeni cannabis medica, 2500 \u00b5g\/mL ognuno in Isopropanolo, 1 ml\/ampolla<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34095\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34096\">                                N\u00b0 Catalogo 34096                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Standard 2 terpeni cannabis medica, 2500 \u00b5g\/mL ognuno in Isopropanolo, 1 ml\/ampolla<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34096\">Esplora Prodotto<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Now that we&rsquo;re getting into the warmer months of the year, you&rsquo;re probably starting to see pop-up beer gardens or people outside relaxing with a nice cold one. Since the beer industry has been evolving and people are enjoying craft&#8230;<\/p>\n","protected":false},"author":32,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[],"industries-application":[2244,2290,2259],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2332,2333,2336,2338],"ppma_author":[452],"class_list":["post-51596","post","type-post","status-publish","format-standard","hentry","category-blogs","industries-application-produzione-chimica","industries-application-food-beverage-it","industries-application-sicurezza-alimentare","resource-technique-gascromatografia-gc","resource-technique-tecniche-di-iniezione","resource-technique-spettometria-di-massa-ms","resource-technique-microestrazione-in-fase-solida-spme"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}],"industries-application":[{"value":2244,"label":"Produzione Chimica"},{"value":2290,"label":"Food &amp; Beverage"},{"value":2259,"label":"Sicurezza Alimentare"}],"resource-technique":[{"value":2332,"label":"Gascromatografia (GC)"},{"value":2333,"label":"Tecniche di Iniezione"},{"value":2336,"label":"Spettometria di Massa (MS)"},{"value":2338,"label":"Microestrazione in Fase Solida (SPME)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Colton Myers","author_link":"https:\/\/discover.restek.com\/it\/author\/colton-myers\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":9,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":452,"user_id":32,"is_guest":0,"slug":"colton-myers","display_name":"Colton Myers","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg"},"author_category":"1","first_name":"Colton","last_name":"Myers","user_url":"https:\/\/www.linkedin.com\/in\/myerscolton\/","job_title":"Product Manager - New Product Development","description":"Colton Myers is a Product Manager for GC columns at Restek Corporation with over 10 years of experience in research and development. He specializes in driving new GC column technologies from concept to market, combining deep technical expertise with a strong focus on innovation and commercialization. Colton holds a BS in chemistry from Juniata College and a Master of Management in Corporate Innovation and Entrepreneurship from Penn State University."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/51596","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/32"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=51596"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/51596\/revisions"}],"predecessor-version":[{"id":58646,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/51596\/revisions\/58646"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=51596"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=51596"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=51596"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=51596"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=51596"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=51596"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=51596"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=51596"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=51596"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}