{"id":51780,"date":"2015-04-26T14:30:00","date_gmt":"2015-04-26T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/residual-solvents-in-cannabis-to-ms-or-not-to-ms\/"},"modified":"2026-01-28T15:59:41","modified_gmt":"2026-01-28T15:59:41","slug":"residual-solvents-in-cannabis-to-ms-or-not-to-ms","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/blogs\/gnbl4782\/residual-solvents-in-cannabis-to-ms-or-not-to-ms","title":{"rendered":"Residual Solvents in Cannabis \u2013 to MS or not to MS?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Over the past few months, I\u2019ve gotten numerous questions about the best detection method for terpenes and residual solvents in cannabis. It seems that a lot of people are purchasing GC-MS instruments for both of these analyses. While GC-MS is indeed a powerful tool, it\u2019s not really necessary for either analysis. In fact, the use of MS for residual solvent analysis can be problematic enough to make its use prohibitive. So what\u2019s the best analysis and detection method for both terpenes and residual solvents? The humble GC-FID. If you\u2019re interested in the reasons why, read on! I\u2019ll be splitting this blog into two parts (residual solvents and terpenes), so make sure to stay tuned for the next portion on terpenes to be posted in a few days.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When most people think about doing trace analyses, their first thought is to go with the most sensitive piece of equipment they can easily get their hands on, which is MS, which can be operated in selected ion monitoring mode. Most of the time, this is a really good approach, but for residual solvents \u2013 especially cannabis residual solvents \u2013 this can backfire on you due to the air that is injected along with your headspace sample. Remember headspace sampling involves injection of a large volume of gas from your headspace vial. This is completely different from a liquid injection in which a very small amount of liquid is injected and no air is introduced into the system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Let&#8217;s pretend that we have a sample of headspace containing 500ppm of butane. That&#8217;s a&nbsp;<em>lot<\/em>&nbsp;of butane, but if we think about it another way, our sample contains 99.95% room air. Since butane often elutes under the tail end of our air peak, when butane elutes from our column, it&#8217;s also eluting with a much larger amount of air. When both butane and air are introduced into a mass spectrometer, the much larger amount of air will interfere with butane in the MS source. This interference may cause signal suppression, resulting in loss of sensitivity and linearity.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In addition to direct interference of air for butane, most of the rest of our analytes (through pentane) all share very small mass fragments. One of the drawbacks for MS is that in general, MS has low detectability for low molecular weight fragments due to background interferences from leaks, column phase, and carrier gas impurities. So most of the sensitivity you gain by purchasing a MS is lost due to interferences. In reality, FID is generally at least as sensitive as MS for analysis of low molecular weight volatiles, if not more, and FIDs are blind to air, which is important with headspace analyses of early-eluting compounds.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Remember to stay tuned for part two of this blog, which will discuss terpene analysis via GC-MS versus GC-FID!<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Over the past few months, I&rsquo;ve gotten numerous questions about the best detection method for terpenes and residual solvents in cannabis. It seems that a lot of people are purchasing GC-MS instruments for both of these analyses. While GC-MS is&#8230;<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[],"industries-application":[2149,2151],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2294,2296,2301],"ppma_author":[511],"class_list":["post-51780","post","type-post","status-publish","format-standard","hentry","category-blogs","industries-application-cannabis","industries-application-medical-or-recreational-cannabis","resource-technique-gas-chromatography-gc","resource-technique-headspace","resource-technique-mass-spectrometry-ms"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}],"industries-application":[{"value":2149,"label":"Cannabis"},{"value":2151,"label":"Medical or Recreational Cannabis"}],"resource-technique":[{"value":2294,"label":"Gas Chromatography (GC)"},{"value":2296,"label":"Headspace"},{"value":2301,"label":"Mass Spectrometry (MS)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Patrick Gallagher","author_link":"https:\/\/discover.restek.com\/it\/author\/patrick-gallagherrestek-com\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":9,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":511,"user_id":85,"is_guest":0,"slug":"amanda-rigdon","display_name":"Amanda Rigdon","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-rigdon-amanda.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-rigdon-amanda.jpg"},"author_category":"1","first_name":"Amanda","last_name":"Rigdon","user_url":"https:\/\/www.linkedin.com\/in\/amanda-itnyre-rigdon-b06aa84\/","job_title":"Principal Scientist","description":"Amanda Rigdon is an analytical chemist with more than 21 years of experience in chromatography and mass spectrometry. Throughout her career, she has worked in a variety of analytical fields, including clinical forensics, food safety, environmental analysis, and cannabis testing. Her experience spans method development, validation, troubleshooting, and laboratory operations using both GC and LC methodologies. Amanda also served as Chief Scientific Officer of an ISO\/IEC 17025-accredited cannabis testing laboratory, where she gained extensive experience in quality systems, regulatory compliance, and laboratory management. She is currently a Principal Scientist in the GC Applications Group at Restek, where she enjoys helping customers solve analytical challenges and sharing practical chromatography knowledge through technical support, presentations, and educational content."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/51780","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=51780"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/51780\/revisions"}],"predecessor-version":[{"id":85451,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/51780\/revisions\/85451"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=51780"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=51780"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=51780"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=51780"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=51780"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=51780"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=51780"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=51780"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=51780"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}