{"id":76481,"date":"2023-09-25T00:00:00","date_gmt":"2023-09-25T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=76481"},"modified":"2026-07-29T20:53:14","modified_gmt":"2026-07-29T20:53:14","slug":"why-tubing-and-fittings-matter-in-hplc-uhplc-dont-overlook-the-little-things","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/faq\/gnbl5559\/why-tubing-and-fittings-matter-in-hplc-uhplc-dont-overlook-the-little-things","title":{"rendered":"Why Tubing and Fittings Matter in HPLC\/UHPLC: Don\u2019t Overlook the Little Things!"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"372\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-why-tubing-and-fittings-matter-in-hplc-uhplc-dont-overlook-the-little-things-01.jpg\" alt=\"\" class=\"wp-image-76576\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-why-tubing-and-fittings-matter-in-hplc-uhplc-dont-overlook-the-little-things-01.jpg 1000w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-why-tubing-and-fittings-matter-in-hplc-uhplc-dont-overlook-the-little-things-01-300x112.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-why-tubing-and-fittings-matter-in-hplc-uhplc-dont-overlook-the-little-things-01-768x286.jpg 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">In this blog, we&#8217;ll dive into the often-underestimated world of tubing and fittings in High-Performance Liquid Chromatography (HPLC) and Ultra-High-Performance Liquid Chromatography (UHPLC) systems. We&#8217;ll explore how these seemingly insignificant components can make or break your chromatography game. From the impact of excess tubing to selecting the right fittings, we&#8217;ll provide you with practical insights and recommendations to optimize your system&#8217;s performance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">So, you&#8217;ve got a shiny new <a href=\"https:\/\/www.restek.com\/c\/1119\" target=\"_blank\" rel=\"noopener\">HPLC column<\/a> and a top-notch instrument, but your chromatography results are disappointing. What gives? Well, the culprit might just be your tubing and fittings. This blog may shed light on their importance and show you why they deserve your attention.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">1. Excess Tubing and Chromatographic Woes:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Believe it or not, excess tubing can wreak havoc on your chromatography. We&#8217;ve got an eye-opening article titled &#8220;<a href=\"https:\/\/discover.restek.com\/ffar3688\/how-extra-column-volume-affects-cannabinoids-analysis-and-lc-column-choice\/\">How Extra Column Volume Affects Cannabinoids Analysis and LC Column Choice<\/a>&#8221; that reveals the nitty-gritty details. It&#8217;s an essential read to understand how excess volume can mess with your results.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2. Fitting Selection:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Let&#8217;s get down to it\u2014choosing the right tubing and fittings is key to a smooth-running HPLC\/UHPLC system. Check out this table featuring various fittings, their Restek catalog numbers, pressure limits, and what tubing to use with them:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Fittings<\/strong><\/td><td><strong>Restek Catalog #<\/strong><\/td><td><strong>Pressure limit<\/strong><\/td><td><strong>Use with what Tubing<\/strong><\/td><\/tr><tr><td>Standard 1\/16&#8243; nuts and ferrules<\/td><td><a href=\"https:\/\/www.restek.com\/p\/26537\" target=\"_blank\" rel=\"noreferrer noopener\">26537<\/a><\/td><td>20,000 psi<\/td><td>stainless steel<\/td><\/tr><tr><td>EXP Reusable Hand-Tight nut w\/ferrule<\/td><td><a href=\"https:\/\/www.restek.com\/p\/25937\" target=\"_blank\" rel=\"noreferrer noopener\">25937<\/a><\/td><td>8700+ psi by hand, 20,000+ psi by a wrench<\/td><td>PEEK and stainless steel<\/td><\/tr><tr><td>EXP Hex-Head (two sizes)<\/td><td><a href=\"https:\/\/www.restek.com\/p\/25926\" target=\"_blank\" rel=\"noreferrer noopener\">25926<\/a>, <a href=\"https:\/\/www.restek.com\/p\/25930\" target=\"_blank\" rel=\"noreferrer noopener\">25930<\/a><\/td><td>8700+ psi by hand, 20,000+ psi by a wrench<\/td><td>PEEK and stainless steel<\/td><\/tr><tr><td>EXP2 Reusable fittings<\/td><td><a href=\"https:\/\/www.restek.com\/p\/25783\" target=\"_blank\" rel=\"noreferrer noopener\">25783<\/a><\/td><td>20,000 psi+ (1400 bar) tested to 30,000 psi (2068 bar)<\/td><td>PEEK and stainless steel<\/td><\/tr><tr><td>EXP2 TI-LOK All-in-One<\/td><td><a href=\"https:\/\/www.restek.com\/p\/25745\" target=\"_blank\" rel=\"noreferrer noopener\">25745<\/a><\/td><td>18,000 psi (1250 bar) no wrench<\/td><td>PEEK, PEEKsil, Hastelloy C, stainless steel, fused silica<\/td><\/tr><tr><td>PPS Hex-Head<\/td><td><a href=\"https:\/\/www.restek.com\/p\/27714\" target=\"_blank\" rel=\"noreferrer noopener\">27714<\/a><\/td><td>5000 psi (350 bar)<\/td><td>PEEK and stainless steel<\/td><\/tr><tr><td>PEEK-HT<\/td><td><a href=\"https:\/\/www.restek.com\/p\/27713\" target=\"_blank\" rel=\"noreferrer noopener\">27713<\/a><\/td><td>10,000 psi (689 bar) no wrench<\/td><td>PEEK and stainless steel<\/td><\/tr><tr><td>PEEK Hex-Head<\/td><td><a href=\"https:\/\/www.restek.com\/p\/27712\" target=\"_blank\" rel=\"noreferrer noopener\">27712<\/a><\/td><td>5000 psi (350 bar)<\/td><td>PEEK and stainless steel<\/td><\/tr><tr><td>Universal 10-32 PEEK finger tight<\/td><td><a href=\"https:\/\/www.restek.com\/p\/25015\" target=\"_blank\" rel=\"noreferrer noopener\">25015<\/a>, <a href=\"https:\/\/www.restek.com\/p\/25016\" target=\"_blank\" rel=\"noreferrer noopener\">25016<\/a>, <a href=\"https:\/\/www.restek.com\/p\/27710\" target=\"_blank\" rel=\"noreferrer noopener\">27710<\/a><\/td><td>5000 psi (350 bar)<\/td><td>PEEK and stainless steel<\/td><\/tr><tr><td>Stainless Steel fittings for UHPLC Valco and Rheodyne ferrules<\/td><td><a href=\"https:\/\/www.restek.com\/p\/27727\" target=\"_blank\" rel=\"noreferrer noopener\">27727<\/a>&#8211;<a href=\"https:\/\/www.restek.com\/p\/27735\" target=\"_blank\" rel=\"noreferrer noopener\">27735<\/a><\/td><td>20,000 psi (1375 bar) Valco-Style nuts, 7250 psi (500 bar) Rheodyne-Style nuts<\/td><td>Specific for valves.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">3. Tubing Talk:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Now, let&#8217;s talk tubing. Here&#8217;s a table that spills the beans on different tubing options, their Restek catalog numbers, pressure limits, and where they shine:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Tubing<\/strong><\/td><td><strong>Restek Catalog number<\/strong><\/td><td><strong>Pressure limit<\/strong><\/td><td><strong>Instrument<\/strong><\/td><\/tr><tr><td>Capillary Stainless-Steel Tubing<\/td><td><a href=\"https:\/\/www.restek.com\/p\/25740\" target=\"_blank\" rel=\"noreferrer noopener\">25740<\/a>, <a href=\"https:\/\/www.restek.com\/p\/26525\" target=\"_blank\" rel=\"noreferrer noopener\">26525<\/a>&#8211;<a href=\"https:\/\/www.restek.com\/p\/26537\" target=\"_blank\" rel=\"noreferrer noopener\">26537<\/a><\/td><td>600 bar<\/td><td>Agilent instruments<\/td><\/tr><tr><td>PEEK<\/td><td><a href=\"https:\/\/www.restek.com\/p\/27746\" target=\"_blank\" rel=\"noreferrer noopener\">27746<\/a>&#8211;<a href=\"https:\/\/www.restek.com\/p\/27756\" target=\"_blank\" rel=\"noreferrer noopener\">27756<\/a><\/td><td>5000 psi or 7000 psi (varies with internal diameter)<\/td><td>HPLC instruments<\/td><\/tr><tr><td>Stainless-Steel Precut<\/td><td><a href=\"https:\/\/www.restek.com\/p\/25813\" target=\"_blank\" rel=\"noreferrer noopener\">25813<\/a>&#8211;<a href=\"https:\/\/www.restek.com\/p\/25827\" target=\"_blank\" rel=\"noopener\">25827<\/a><\/td><td>20,230 psi to 27,850 psi (varies with internal diameter)<\/td><td>UHPLC or HPLC instruments<\/td><\/tr><tr><td>Stainless Steel Coil<\/td><td><a href=\"https:\/\/www.restek.com\/p\/27757\" target=\"_blank\" rel=\"noreferrer noopener\">27757<\/a>&#8211;<a href=\"https:\/\/www.restek.com\/p\/27780\" target=\"_blank\" rel=\"noreferrer noopener\">27780<\/a><\/td><td>10,645 psi to 27,580 psi (varies with internal diameter)<\/td><td>UHPLC or HPLC instruments<\/td><\/tr><tr><td>Flexible Premium Stainless Steel<\/td><td><a href=\"https:\/\/www.restek.com\/p\/27781\" target=\"_blank\" rel=\"noreferrer noopener\">27781<\/a>&#8211;<a href=\"https:\/\/www.restek.com\/p\/27796\" target=\"_blank\" rel=\"noreferrer noopener\">27796<\/a><br><a href=\"https:\/\/www.restek.com\/p\/27800\" target=\"_blank\" rel=\"noopener\">27800<\/a>&#8211;<a href=\"https:\/\/www.restek.com\/p\/27805\" target=\"_blank\" rel=\"noreferrer noopener\">27805<\/a>,\u00a0<a href=\"https:\/\/www.restek.com\/p\/27808\" target=\"_blank\" rel=\"noreferrer noopener\">27808<\/a><br><a href=\"https:\/\/www.restek.com\/p\/27810\" target=\"_blank\" rel=\"noreferrer noopener\">27810<\/a>&#8211;<a href=\"https:\/\/www.restek.com\/p\/27813\" target=\"_blank\" rel=\"noreferrer noopener\">27813<\/a><\/td><td>20,230 psi to 27,580psi (1395 bar to 1902 bar) (varies with internal diameter)<\/td><td>UHPLC or HPLC instruments<\/td><\/tr><tr><td>Secure-Fit (PEEK and Stainless Steel)<\/td><td><a href=\"https:\/\/www.restek.com\/p\/25211\" target=\"_blank\" rel=\"noreferrer noopener\">25211<\/a>, <a href=\"https:\/\/www.restek.com\/p\/26513\" target=\"_blank\" rel=\"noreferrer noopener\">26513<\/a>, <a href=\"https:\/\/www.restek.com\/p\/25188\" target=\"_blank\" rel=\"noreferrer noopener\">25188<\/a>, <a href=\"https:\/\/www.restek.com\/p\/25236\" target=\"_blank\" rel=\"noreferrer noopener\">25236<\/a>, <a href=\"https:\/\/www.restek.com\/p\/25237\" target=\"_blank\" rel=\"noreferrer noopener\">25237<\/a><\/td><td>400 bar<\/td><td>HPLC instruments<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">4. Tips and Tricks for Tubing and Fittings:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">We&#8217;ve got your back with some handy tips and tricks to get the most out of your tubing and fittings:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Keep It Lean:<\/strong> Minimize extra tubing volume to avoid pesky gradient delays. Long and narrow tubing can crank up the pressure, so keep it in check. <a href=\"https:\/\/discover.restek.com\/gnav3626\/minimizing-lc-system-volume\/\">Minimizing LC System Volume<\/a><\/li>\n\n\n\n<li><strong>The Right Fit (ID):<\/strong> Match the tubing&#8217;s internal diameter (ID) with your system&#8217;s requirements. Using the wrong ID can result in wider but shorter peaks. For HPLC systems with 4.6 mm ID columns, go for tubing with an ID of 0.17 mm. UHPLC systems call for 0.12 mm ID or 0.07 mm ID. Semi-prep and prep HPLC systems use 0.020-inch tubing or bigger.<\/li>\n\n\n\n<li><strong>Peek at PEEK:<\/strong> PEEK tubing is great when you need a bioinert system, have compounds that don&#8217;t play well with stainless steel, or if you frequently change connections between the autosampler and column. Just watch out for solvents like tetrahydrofuran, DMSO, or chlorinated solvents\u2014they can make PEEK tubing brittle.<\/li>\n\n\n\n<li><strong>Don&#8217;t Get Swaged Away:<\/strong> Steer clear of pre-swaged or nonadjustable fittings when connecting to HPLC columns. They won&#8217;t give you the flexibility you need.<\/li>\n\n\n\n<li><strong>Cut It Right:<\/strong> Use a clean-cut tubing cutter (catalog 25069) for PEEK tubing.&nbsp;<\/li>\n\n\n\n<li><strong>Seat It Right:<\/strong> Properly seat those fittings to avoid peak shape problems. Leaving gaps inside the fittings can lead to poor peaks, lower resolution, and even carryover issues.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Tubing and fittings might be small, but they pack a punch in HPLC\/UHPLC systems. Don&#8217;t underestimate their impact on your chromatography. By following our tips and giving them the attention, they deserve, you&#8217;ll unlock the full potential of your liquid chromatography adventures.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>In this blog, we&#8217;ll dive into the often-underestimated world of tubing and fittings in High-Performance Liquid Chromatography (HPLC) and Ultra-High-Performance Liquid Chromatography (UHPLC) systems.<\/p>\n","protected":false},"author":33,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[23],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[453],"class_list":["post-76481","post","type-post","status-publish","format-standard","hentry","category-faq"],"acf":[],"taxonomy_info":{"category":[{"value":23,"label":"FAQ"}]},"featured_image_src_large":false,"author_info":{"display_name":"Gary Oden","author_link":"https:\/\/discover.restek.com\/it\/author\/gary-oden\/"},"comment_info":0,"category_info":[{"term_id":23,"name":"FAQ","slug":"faq","term_group":0,"term_taxonomy_id":23,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":23,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq","category_parent":0}],"tag_info":false,"authors":[{"term_id":453,"user_id":33,"is_guest":0,"slug":"gary-oden","display_name":"Gary Oden","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-oden-gary.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-oden-gary.jpg"},"author_category":"1","first_name":"Gary","last_name":"Oden","user_url":"https:\/\/www.linkedin.com\/in\/gary-oden-jr-a35ba74b\/","job_title":"Technical Service, Specialist I","description":"Gary has 20 years of hands-on experience with chromatography, including SPE, HPLC, and LC\/MS instrumentation. He began his chromatography career in the laboratory as a bonding chemist and has served as a study director for PFAS analysis, specializing in both bioanalytical and environmental fields. His work in developing HPLC and LC\/MS-MS applications has further broadened his expertise in chromatography. Since 2018, Gary has been a key member of Restek\u2019s European-based technical support team, where he offers expert assistance to customers in overcoming complex analytical challenges."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/76481","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/33"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=76481"}],"version-history":[{"count":11,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/76481\/revisions"}],"predecessor-version":[{"id":96083,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/76481\/revisions\/96083"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=76481"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=76481"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=76481"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=76481"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=76481"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=76481"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=76481"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=76481"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=76481"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}