{"id":89829,"date":"2026-03-10T18:29:37","date_gmt":"2026-03-10T18:29:37","guid":{"rendered":"https:\/\/discover.restek.com\/?p=89829"},"modified":"2026-08-11T17:00:00","modified_gmt":"2026-08-11T17:00:00","slug":"orphine-analogs-the-new-nps-in-town","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/it\/blog-it\/gnbl5646\/orphine-analogs-the-new-nps-in-town","title":{"rendered":"Orphine Analogs\u2014The New NPS in Town"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Move over, nitazenes! There\u2019s a new NPS in town. In July of 2025, the Chinese government announced that nitazene analogs would be placed under national control, ultimately leading to a decline in positivity for these compounds. [1,2] <sup>&nbsp;<\/sup>It hasn\u2019t taken long for a new subclass of designer drugs to take their place. Over the last several months, a group of synthetic opioids known as \u201corphine analogs\u201d have been increasingly detected in toxicology and seized drug cases.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Despite the recent attention orphines have been garnering, this subclass of drugs has been around for some time. Some of these compounds, such as spirochlorphine, were originally synthesized for potential pharmaceutical use back in the 1970s. [3] &nbsp;The compound brorphine made headlines back 2020 after it was detected in several overdose cases but fell out of popularity after the U.S. DEA deemed it a controlled substance. [4] &nbsp;Much like the nitazene analogs, the orphines have started to evolve and new substances are emerging on the illicit drug market. While information on the pharmacology of these compounds is still limited, there is data that suggests that some of these compounds may be more potent than fentanyl. [2]<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If your lab is considering adding one or more of these orphine analogs to your LC-MS\/MS testing method, you\u2019ve come to the right place. Below you will find the precursor and product ions for two frequently encountered orphines as well as where you might expect them to elute in a multi-drug class assay like our <a href=\"https:\/\/discover.restek.com\/articles\/cfss2310\/big-pain-assays-arent-a-big-pain-with-the-raptor-biphenyl-lc-column\">\u201cBig Pain\u201d<\/a> panel.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h6 class=\"wp-block-heading\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-2-color\">Table 1: \u201cBig Pain\u201d Panel LC-MS\/MS Method Conditions<\/mark><\/strong><\/h6>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Column<\/td><td colspan=\"3\">Raptor Biphenyl, 100 x 2.1 mm, 2.7 \u00b5m (cat.#9309A12)<\/td><\/tr><tr><td>Guard Column<\/td><td colspan=\"3\">Raptor Biphenyl EXP guard column cartridge, 5 x 2.1 mm, 2.7 \u00b5m (cat.# 9309A0252)<\/td><\/tr><tr><td>Mobile Phase A<\/td><td colspan=\"3\">Water, 0.1% formic acid, 2 mM ammonium formate<\/td><\/tr><tr><td>Mobile Phase B<\/td><td colspan=\"3\">Methanol, 0.1% formic acid, 2 mM ammonium formate<\/td><\/tr><tr><td>Diluent<\/td><td colspan=\"3\">Water<\/td><\/tr><tr><td>Column Temperature<\/td><td colspan=\"3\">30\u00b0C<\/td><\/tr><tr><td>Injection Volume<\/td><td colspan=\"3\">5 \u00b5L<\/td><\/tr><tr><td>Flow Rate<\/td><td colspan=\"3\">0.6 mL\/min<\/td><\/tr><tr><td rowspan=\"6\">Gradient<\/td><td>Time (min)<\/td><td>%A<\/td><td>%B<\/td><\/tr><tr><td>0.00<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>9.00<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>10.00<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>10.01<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>12.00<\/td><td>95<\/td><td>5<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h6 class=\"wp-block-heading\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-2-color\">Figure 1: 100 ng\/mL of Cychlorphine and Spirochlorphine Using \u201cBig Pain\u201d Method Conditions<\/mark><\/strong><\/h6>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"297\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Figure-1-blog-Haley-orphine-analysis-1024x297.png\" alt=\"\" class=\"wp-image-89835\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Figure-1-blog-Haley-orphine-analysis-1024x297.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/Figure-1-blog-Haley-orphine-analysis-300x87.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/Figure-1-blog-Haley-orphine-analysis-768x223.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/Figure-1-blog-Haley-orphine-analysis-1536x446.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/Figure-1-blog-Haley-orphine-analysis-2048x594.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h6 class=\"wp-block-heading\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-2-color\">Table 2: MRM Transitions for Cychlorphine and Spirochlorphine<\/mark><\/strong><\/h6>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Analyte<\/td><td>T<sub>R<\/sub> (min)<\/td><td>Precursor Ion<\/td><td>Product Ion<\/td><td>Product Ion<\/td><td>Ion Mode<\/td><\/tr><tr><td>Cychlorphine<\/td><td>6.05<\/td><td>409.1<\/td><td>271.0<\/td><td>138.9<\/td><td>ESI +<\/td><\/tr><tr><td>Spirochlorphine<\/td><td>6.13<\/td><td>370.1<\/td><td>232.1<\/td><td>126.9<\/td><td>ESI +<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Analyzed in ESI positive mode, both analytes will form a precursor ion of [M+H]<sup>+<\/sup>. While precursor and product ions should always be optimized for each LC-MS\/MS system, the MRM transitions shown above are commonly observed for these compounds and may be used as a starting point for your own method development. Both compounds were found to elute just after six minutes using the described method conditions. Fentanyl (6.02 min) is expected to elute near these compounds as it bears some structural similarities to the orphine analogs. For a complete list of compounds and retention times included in this method, please see <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/LC_CF0621\" target=\"_blank\" rel=\"noopener\">Multiclass Drug Panel on Raptor Biphenyl by LC-MS\/MS<\/a>.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h6 class=\"wp-block-heading\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-2-color\">References<\/mark><\/strong><\/h6>\n\n\n\n<ol class=\"wp-block-list\">\n<li>UNODC Laboratory and Scientific Service Portals, China: Announcement of class scheduling of \u201cnitazene\u201d analogues, July 2025. <a href=\"http:\/\/www.unodc.org\/LSS\/Announcement\/Details\/7e29daf9-1d49-45e6-95e7-8ce932bc94e1\" target=\"_blank\" rel=\"noopener\">www.unodc.org\/LSS\/Announcement\/Details\/7e29daf9-1d49-45e6-95e7-8ce932bc94e1<\/a><\/li>\n\n\n\n<li>A.J. Krotulski, D.M .Papsun, B.N. Stang, S.E. Walton, B.K. Logan. Public alert: Increase in fatal overdoses linked to novel synthetic opioid N-propionitrile chlorphine (cychlorphine), Center for Forensic Science Research and Education, United States, 2026. <a href=\"https:\/\/www.cfsre.org\/nps-discovery\/public-alerts\/increase-in-fatal-overdoses-linked-to-novel-synthetic-opioid-n-propionitrile-chlorphine-cychlorphine\" target=\"_blank\" rel=\"noopener\">https:\/\/www.cfsre.org\/nps-discovery\/public-alerts\/increase-in-fatal-overdoses-linked-to-novel-synthetic-opioid-n-propionitrile-chlorphine-cychlorphine<\/a><\/li>\n\n\n\n<li>K.D. Stahl, W. Van Bever, P. Janssen, E.J. Simon, Receptor affinity and pharmacological potency of a series of narcotic analgesic, anti-diarrheal and neuroleptic drugs, Eur. J. Pharmacol., 46 (3) (1977) 199-205. <a href=\"https:\/\/doi.org\/10.1016\/0014-2999(77)90334-X\" target=\"_blank\" rel=\"noopener\">https:\/\/doi.org\/10.1016\/0014-2999(77)90334-X<\/a>.<\/li>\n\n\n\n<li>M.M Vandeputte, A.J Krotulski, D.M Papsun, B. K Logan, C.P. Stove, The rise and fall of isotonitazene and brorphine: Two recent stars in the synthetic opioid firmament, J. Anal. Toxicol., 46 (2) (2022) 115\u2013121. <a href=\"https:\/\/doi.org\/10.1093\/jat\/bkab082\" target=\"_blank\" rel=\"noopener\">https:\/\/doi.org\/10.1093\/jat\/bkab082<\/a><\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>Move over, nitazenes! There\u2019s a new NPS in town. In July of 2025, the Chinese government announced that nitazene analogs would be placed under national control, ultimately leading to a decline in positivity for these compounds. [1,2] &nbsp;It hasn\u2019t taken long for a new subclass of designer drugs to take their place. Over the last&#8230;<\/p>\n","protected":false},"author":13,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[793],"tags":[],"industries-application":[],"post-badge":[2767],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[432],"class_list":["post-89829","post","type-post","status-publish","format-standard","hentry","category-blog-it","post-badge-new"],"acf":[],"taxonomy_info":{"category":[{"value":793,"label":"Blog"}],"post-badge":[{"value":2767,"label":"New"}]},"featured_image_src_large":false,"author_info":{"display_name":"Haley Berkland, MS","author_link":"https:\/\/discover.restek.com\/it\/author\/haley-berkland-ms\/"},"comment_info":0,"category_info":[{"term_id":793,"name":"Blog","slug":"blog-it","term_group":0,"term_taxonomy_id":793,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":793,"category_count":457,"category_description":"","cat_name":"Blog","category_nicename":"blog-it","category_parent":0}],"tag_info":false,"authors":[{"term_id":432,"user_id":13,"is_guest":0,"slug":"haley-berkland-ms","display_name":"Haley Berkland, MS","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg"},"author_category":"1","first_name":"Haley","last_name":"Berkland","user_url":"https:\/\/www.linkedin.com\/in\/haley-berkland-60b66517b\/","job_title":"LC Applications Scientist","description":"Haley is an LC applications scientist at Restek. She attended Duquesne University, receiving her bachelor's degree in biochemistry and a master's degree in forensic science and law. As a graduate student, she performed research on the detection of drugs of abuse in vitreous humor by LC-MS\/MS. Before joining Restek in 2023, Haley spent four years working as a forensic toxicologist. While in this role, she performed analysis of postmortem toxicology casework, identification of seized drug evidence, and development\/validation of new assays by LC-MS\/MS, GC-MS, and GC-FID."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/89829","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/comments?post=89829"}],"version-history":[{"count":15,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/89829\/revisions"}],"predecessor-version":[{"id":97867,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/posts\/89829\/revisions\/97867"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/media?parent=89829"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/categories?post=89829"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/tags?post=89829"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/industries-application?post=89829"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/post-badge?post=89829"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-type?post=89829"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/product-library?post=89829"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/resource-technique?post=89829"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/it\/wp-json\/wp\/v2\/ppma_author?post=89829"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}