技術資料

Cross Reference for Agilent Syringes

19 Oct 2020

Listed below are some Hamilton and SGE syringes, cross-referenced to Agilent part numbers for your convenience. For further information or questions, contact your Restek sales representative or technical service.

Similar to Agilent Part #Restek Part #Description
5181-126721212, 2459610 µL Standard Syringe, Fixed Needle, 23-26 Gauge
5181-127321210, 245935 µL Standard Syringe, Fixed Needle, 23-26 Gauge
5181-331920166Needle for 10 µL Standard Syringe, 23-26 Gauge
5181-33212459810 µL Standard Syringe, Removable Needle, 23-26 Gauge
5181-335824919PTFE-Tipped Plunger for 10 µL Standard Syringe, Removable Needle
5181-336021215, 2460010 µL Standard Syringe, Fixed Needle, 23-26 Gauge (6-pk.)
5181-336521218PTFE-Tipped Plunger for 10 µL Standard Syringe, Fixed Needle
5181-880924894, 2478910 µL Gas-tight Syringe, Fixed Needle, 23 Gauge
5181-881120164, 24825Needle for 10 µL Gas-tight Syringe, 23 Gauge
5181-88132122410 µL Gas-tight Syringe, Removable Needle, 23 Gauge
5182-083220166Needle for 5-10 µL Autosampler Syringe, 23-26 Gauge
5182-0834201725 µL Standard Syringe, Removable Needle, 23 Gauge
5182-0835212235 µL Standard Syringe, Removable Needle, 23-26 Gauge
5182-087520170, 247835 µL Standard Syringe, Fixed Needle, 23 Gauge (6-pk.)
9301-071320167, 2478510 µL Standard Syringe, Fixed Needle, 23 Gauge
9301-071424595, 2478410 µL Standard Syringe, Fixed Needle, 26 Gauge
9301-072520169, 2478710 µL Standard Syringe, Fixed Needle, 23 Gauge (6-pk.)
9301-089124592, 247805 µL Standard Syringe, Fixed Needle, 26 Gauge
9301-089220168, 247815 µL Standard Syringe, Fixed Needle, 23 Gauge

Needle Gauge for Agilent 7673, 7683, 6850 Syringes

figure article GNOT3405 01

Single Gauge Needle—23s (0.64 mm)

  • The most popular gauge for Agilent 7673.
  • Best for Merlin Microseal septum and standard septum-equipped GCs.
  • Packed column injection ports.
  • Split/splitless injection ports.
figure article GNOT3405 02

Single Gauge Needle—26s (0.47 mm)

  • On-column injection ports.
  • Split/splitless injection ports.
figure article GNOT3405 03

Dual Gauge (Tapered) Needle—23s-26s

  • Durability of a 23s gauge needle.
  • Ability of a 26s gauge needle to perform split/splitless and on-column injections.

著者 / 執筆者

GNOT3405
バージョン B