{"id":100438,"date":"2014-04-08T00:00:00","date_gmt":"2014-04-08T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized-ja\/fatty-acid-methyl-esters-fames-converting-by-weight-to-gml\/"},"modified":"2026-10-02T18:02:13","modified_gmt":"2026-10-02T18:02:13","slug":"fatty-acid-methyl-esters-fames-converting-by-weight-to-gml","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl5493-ja\/fatty-acid-methyl-esters-fames-converting-by-weight-to-gml","title":{"rendered":"\u8102\u80aa\u9178\u30e1\u30c1\u30eb\u30a8\u30b9\u30c6\u30eb\uff08FAMES\uff09\u306e\u6fc3\u5ea6\u63db\u7b97\uff5c\u91cd\u91cf%\u304b\u3089\u00b5g\/mL\u3078"},"content":{"rendered":"\n<style data-wp-block-html=\"css\">\n<style>\n.rtk-article { line-height: 1.8; font-size: 16px; }\n\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n\n.rtk-article h2 {\n  margin-top: 4em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n\n.rtk-article h3 {\n  margin-top: 2.4em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n\n.rtk-article p {\n  font-size: 18px;\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n\n.rtk-article a {\n  font-size: inherit !important;\n}\n\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n\n.rtk-article .rtk-lead {\n  font-size: 18px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n\n.rtk-article blockquote.rtk-voc {\n  position: relative;\n  border-left: 4px solid #00265d;\n  background: #f7f8f9;\n  padding: 18px 22px 18px 30px;\n  margin: 2em 0;\n  font-style: italic;\n  color: #333;\n}\n.rtk-article blockquote.rtk-voc p { margin-bottom: 0.4em; }\n.rtk-article blockquote.rtk-voc cite {\n  display: block;\n  font-style: normal;\n  font-size: 13px;\n  color: #4a4a4a;\n}\n\n.rtk-article .rtk-coa-list {\n  list-style: none;\n  padding: 0;\n}\n.rtk-article .rtk-coa-list li {\n  background: #fafbfc;\n  border: 1px solid #e1e8ec;\n  border-radius: 6px;\n  padding: 14px 18px;\n  margin-bottom: 12px;\n}\n\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 2.8em; }\n  .rtk-article h3 { margin-top: 1.8em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout,\n  .rtk-article blockquote.rtk-voc {\n    padding: 14px 16px;\n  }\n}\n.rtk-article .rtk-formula {\n  background: #f5f9fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 16px 20px;\n  margin: 1em 0 1.4em;\n  font-family: \"Courier New\", monospace;\n  font-size: 17px;\n  font-weight: 700;\n  line-height: 1.8;\n  color: #1a1a1a;\n}\n.rtk-article .rtk-formula .rtk-formula-result {\n  font-weight: 700;\n  color: #0d7bc4;\n}\n<\/style>\n\n<div class=\"rtk-article\">\n\n  <div class=\"rtk-intro\">\n    <p class=\"rtk-lead\">\u8102\u80aa\u9178\u30e1\u30c1\u30eb\u30a8\u30b9\u30c6\u30eb\uff08FAME\uff09\u6a19\u6e96\u54c1\u306e\u6fc3\u5ea6\u306f\u3001\u30ab\u30bf\u30ed\u30b0\u4e0a\u300c\u91cd\u91cf%\u300d\u3067\u8868\u8a18\u3055\u308c\u3066\u3044\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002GC\u5206\u6790\u3067\u00b5g\/mL\u3068\u3057\u3066\u6271\u3046\u5fc5\u8981\u304c\u3042\u308b\u5834\u5408\u3001\u3053\u306e\u63db\u7b97\u4f5c\u696d\u306b\u6238\u60d1\u3046\u65b9\u3082\u5c11\u306a\u304f\u3042\u308a\u307e\u305b\u3093\u3002\u672c\u8a18\u4e8b\u3067\u306f\u3001\u6df7\u5408\u6a19\u6e96\u54c1\uff08Mix\uff09\u3068\u30cb\u30fc\u30c8\u6a19\u6e96\u54c1\u305d\u308c\u305e\u308c\u306e\u30b1\u30fc\u30b9\u306b\u3064\u3044\u3066\u3001\u5b9f\u969b\u306e\u8a08\u7b97\u5f0f\u3092\u4f7f\u3063\u3066\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n  <\/div>\n\n<div class=\"rtk-article\">\n  <p>\u4ee5\u524d\u3001\u304a\u5ba2\u69d8\u304b\u3089FAME\u6a19\u6e96\u54c1\u306e\u91cd\u91cf%\u3092\u00b5g\/mL\u306b\u5909\u63db\u3059\u308b\u65b9\u6cd5\u306b\u3064\u3044\u3066\u8cea\u554f\u3092\u53d7\u3051\u307e\u3057\u305f\u3002\u305d\u306e\u969b\u3001\u79c1\u81ea\u8eab\u3082\u3059\u3050\u306b\u306f\u7b54\u3048\u3089\u308c\u305a\u3001\u5468\u308a\u306b\u6559\u3048\u3066\u3082\u3089\u3044\u307e\u3057\u305f\u3002\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30fc\u30d3\u30b9\u30c1\u30fc\u30e0\u3067\u3082\u540c\u69d8\u306e\u8cea\u554f\u3092\u53d7\u3051\u308b\u3053\u3068\u304c\u3042\u308b\u305f\u3081\u3001\u4eca\u56de\u306f\u305d\u306e\u8a08\u7b97\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n<div style=\"margin-top: 5em;\"><\/div>\n\n  <h2>\u6df7\u5408\u6a19\u6e96\u54c1\uff08Mix\uff09\u306e\u5834\u5408\u306e\u8a08\u7b97\u4f8b<\/h2>\n\n  <p>\u4f8b\u3068\u3057\u3066\u3001Restek\u306eFood Industry FAME Mix\uff08cat. # <a href=\"https:\/\/www.restek.com\/global\/p\/35077\" target=\"_blank\" rel=\"noopener noreferrer\">35077<\/a>\uff09\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u3053\u306eFood Industry FAME Mix\u306e\u5168\u4f53\u6fc3\u5ea6\u306f30 mg\/mL\u3067\u3059\u3002\u5404\u5316\u5408\u7269\u306e\u6fc3\u5ea6\u306f\u3001\u91cd\u91cf\u6bd4\u30672\u301c6\uff05\u306e\u7bc4\u56f2\u306b\u5206\u5e03\u3057\u3066\u3044\u307e\u3059\u3002\u305d\u308c\u3067\u306f\u3001\u5404\u5316\u5408\u7269\u306e\u6fc3\u5ea6\u3092\u00b5g\/mL\u3067\u8868\u3059\u3068\u3069\u3046\u306a\u308b\u3067\u3057\u3087\u3046\u304b\u3002\u3059\u3079\u3066\u306e\u5316\u5408\u7269\u3092\u6319\u3052\u308b\u306e\u3067\u306f\u306a\u304f\u3001\u8a08\u7b97\u65b9\u6cd5\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n\n  <p>\u6700\u521d\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u5316\u5408\u7269\u306fC4:0\u3067\u3001\u91cd\u91cf\u6bd4\u306f4\uff05\u3067\u3059\u3002\u5168\u4f53\u6fc3\u5ea6\u304c30 mg\/mL\u306e\u305f\u3081\u3001C4:0\u306e\u6fc3\u5ea6\u3092\u00b5g\/mL\u3067\u6c42\u3081\u308b\u8a08\u7b97\u306f\u4ee5\u4e0b\u306e\u901a\u308a\u3067\u3059\u3002<\/p>\n\n<div class=\"rtk-formula\">\n  4\/100 x 30mg\/mL = 0.04 x 30mg\/mL = 1.2mg\/mL<br>\n  \u00b5g\/mL\u3078\u306e\u5909\u63db\uff1a1.2mg\/mL x 1000\u00b5g\/mg = <span class=\"rtk-formula-result\">1200\u00b5g\/mL<\/span>\n<\/div><\/div><\/div>\n\n\n<style>.kb-image100438_bab062-fc .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image100438_bab062-fc size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"200\" height=\"200\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-fatty-acid-methyl-esters-fames-converting-by-weight-to-gml-01.jpg\" alt=\"\" class=\"kb-img wp-image-77740\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-fatty-acid-methyl-esters-fames-converting-by-weight-to-gml-01.jpg 200w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-fatty-acid-methyl-esters-fames-converting-by-weight-to-gml-01-150x150.jpg 150w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><\/figure>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<style data-wp-block-html=\"css\">\n<style>\n.rtk-article { line-height: 1.8; font-size: 16px; }\n\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n\n.rtk-article h2 {\n  margin-top: 4em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n\n.rtk-article h3 {\n  margin-top: 2.4em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n\n.rtk-article p {\n  font-size: 18px;\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n\n.rtk-article a {\n  font-size: inherit !important;\n}\n\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n\n.rtk-article .rtk-lead {\n  font-size: 18px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n\n.rtk-article blockquote.rtk-voc {\n  position: relative;\n  border-left: 4px solid #00265d;\n  background: #f7f8f9;\n  padding: 18px 22px 18px 30px;\n  margin: 2em 0;\n  font-style: italic;\n  color: #333;\n}\n.rtk-article blockquote.rtk-voc p { margin-bottom: 0.4em; }\n.rtk-article blockquote.rtk-voc cite {\n  display: block;\n  font-style: normal;\n  font-size: 13px;\n  color: #4a4a4a;\n}\n\n.rtk-article .rtk-coa-list {\n  list-style: none;\n  padding: 0;\n}\n.rtk-article .rtk-coa-list li {\n  background: #fafbfc;\n  border: 1px solid #e1e8ec;\n  border-radius: 6px;\n  padding: 14px 18px;\n  margin-bottom: 12px;\n}\n\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 2.8em; }\n  .rtk-article h3 { margin-top: 1.8em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout,\n  .rtk-article blockquote.rtk-voc {\n    padding: 14px 16px;\n  }\n}\n.rtk-article .rtk-formula {\n  background: #f5f9fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 16px 20px;\n  margin: 1em 0 1.4em;\n  font-family: \"Courier New\", monospace;\n  font-size: 17px;\n  font-weight: 700;\n  line-height: 1.8;\n  color: #1a1a1a;\n}\n.rtk-article .rtk-formula .rtk-formula-result {\n  font-weight: 700;\n  color: #0d7bc4;\n}\n<\/style>\n\n<div class=\"rtk-article\">\n  <h2>\u30cb\u30fc\u30c8\u6a19\u6e96\u54c1\u306e\u5834\u5408\u306e\u8a08\u7b97\u4f8b<\/h2>\n\n  <p>Marine Oil FAME Mix\uff08cat.# <a href=\"https:\/\/www.restek.com\/global\/p\/35066\" target=\"_blank\" rel=\"noopener noreferrer\">35066<\/a>\uff09\u306e\u3088\u3046\u306a\u30cb\u30fc\u30c8\u6a19\u6e96\u54c1\u3092\u8cfc\u5165\u3057\u305f\u5834\u5408\u306f\u3001\u6700\u7d42\u7684\u306a\u5024\u3092\u6c42\u3081\u308b\u305f\u3081\u306b\u3082\u3046\u4e00\u6bb5\u968e\u306e\u8a08\u7b97\u304c\u5fc5\u8981\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n  <p>\u3053\u306eMarine Oil FAME Mix\u306e\u5185\u5bb9\u91cf\u306f\u7d04100 mg\u3067\u3059\u3002\u8a08\u7b97\u3092\u7c21\u5358\u306b\u3059\u308b\u305f\u3081\u3001\u3053\u3053\u3067\u306f\u6b63\u78ba\u306b100 mg\u3092\u91cf\u308a\u53d6\u308a\u300110 mL\u306e\u5869\u5316\u30e1\u30c1\u30ec\u30f3\u306b\u6eb6\u89e3\u3057\u305f\u3068\u3057\u307e\u3059\u3002\u3053\u306e\u64cd\u4f5c\u306b\u3088\u308a\u3001\u6fc3\u5ea610 mg\/mL\u306e\u6eb6\u6db2\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u3053\u3053\u3067\u3082\u3001\u6700\u521d\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u5316\u5408\u7269\uff08\u3053\u306e\u5834\u5408\u306fC14:0\uff09\u3092\u4f8b\u306b\u8a08\u7b97\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n\n  <p>C14:0\u306f\u30cb\u30fc\u30c8\u6a19\u6e96\u54c1\u4e2d\u306b\u91cd\u91cf\u6bd46\uff05\u3067\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002\u8abf\u88fd\u3057\u305f\u6eb6\u6db2\u306e\u5168\u4f53\u6fc3\u5ea6\u306f10 mg\/mL\u306e\u305f\u3081\u3001\u8a08\u7b97\u306f\u4ee5\u4e0b\u306e\u901a\u308a\u3067\u3059\u3002<\/p>\n\n<div class=\"rtk-formula\">\n  6\/100 x 10mg\/mL = 0.06 x 10mg\/mL = 0.6mg\/mL<br>\n  \u00b5g\/mL\u3078\u306e\u5909\u63db\uff1a0.6mg\/mL x 1000\u00b5g\/mg = <span class=\"rtk-formula-result\">600\u00b5g\/mL<\/span>\n<\/div>\n\n  <h2>\u307e\u3068\u3081<\/h2>\n  <ul>\n    <li>\u6df7\u5408\u6a19\u6e96\u54c1\uff08Mix\uff09\u306f\u300c\u5168\u4f53\u6fc3\u5ea6 \u00d7 \u91cd\u91cf% \u00f7 100\u300d\u3067\u5404\u5316\u5408\u7269\u306e\u6fc3\u5ea6\uff08mg\/mL\uff09\u3092\u6c42\u3081\u30011000\u3092\u639b\u3051\u3066\u00b5g\/mL\u306b\u5909\u63db\u3059\u308b<\/li>\n    <li>\u30cb\u30fc\u30c8\u6a19\u6e96\u54c1\u306f\u3001\u6eb6\u89e3\u5f8c\u306e\u6eb6\u6db2\u6fc3\u5ea6\u3092\u5148\u306b\u6c42\u3081\u305f\u4e0a\u3067\u3001\u540c\u3058\u8a08\u7b97\u3092\u9069\u7528\u3059\u308b<\/li>\n    <li>\u3044\u305a\u308c\u306e\u5834\u5408\u3082\u3001\u8a08\u7b97\u306e\u57fa\u6e96\u3068\u306a\u308b\u300c\u5168\u4f53\u6fc3\u5ea6\u300d\u3092\u6b63\u3057\u304f\u628a\u63e1\u3059\u308b\u3053\u3068\u304c\u91cd\u8981<\/li>\n  <\/ul>\n\n  <div class=\"rtk-callout\">\n    <p><em>\u3054\u4f7f\u7528\u4e2d\u306eFAME\u6a19\u6e96\u54c1\u306e\u91cd\u91cf%\u8868\u8a18\u3084\u30ab\u30bf\u30ed\u30b0\u756a\u53f7\u306b\u3064\u3044\u3066\u78ba\u8a8d\u3057\u305f\u3044\u5834\u5408\u306f\u3001\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30fc\u30d3\u30b9\u307e\u3067\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/em><\/p>\n  <\/div>\n\n  <h2>\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n\n  <details class=\"rtk-faq\">\n    <summary><h3>\u6df7\u5408\u6a19\u6e96\u54c1\u3068\u30cb\u30fc\u30c8\u6a19\u6e96\u54c1\u3067\u3001\u8a08\u7b97\u65b9\u6cd5\u306f\u6839\u672c\u7684\u306b\u7570\u306a\u308a\u307e\u3059\u304b\uff1f<\/h3><\/summary>\n    <p>\u57fa\u672c\u306e\u8a08\u7b97\u5f0f\uff08\u5168\u4f53\u6fc3\u5ea6 \u00d7 \u91cd\u91cf% \u00f7 100 \u00d7 1000\uff09\u306f\u540c\u3058\u3067\u3059\u3002\u7570\u306a\u308b\u306e\u306f\u300c\u5168\u4f53\u6fc3\u5ea6\u300d\u306e\u6c42\u3081\u65b9\u3067\u3001\u6df7\u5408\u6a19\u6e96\u54c1\u306f\u30e9\u30d9\u30eb\u8a18\u8f09\u306e\u6fc3\u5ea6\u3092\u305d\u306e\u307e\u307e\u4f7f\u3044\u3001\u30cb\u30fc\u30c8\u6a19\u6e96\u54c1\u306f\u6eb6\u89e3\u5f8c\u306e\u6eb6\u6db2\u6fc3\u5ea6\u3092\u5148\u306b\u7b97\u51fa\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n  <\/details>\n\n  <details class=\"rtk-faq\">\n    <summary><h3>\u91cd\u91cf%\u3068\u00b5g\/mL\u306e\u63db\u7b97\u306b\u3001\u7279\u5225\u306a\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3084\u88c5\u7f6e\u306f\u5fc5\u8981\u3067\u3059\u304b\uff1f<\/h3><\/summary>\n    <p>\u4e0d\u8981\u3067\u3059\u3002\u8a18\u4e8b\u5185\u3067\u793a\u3057\u305f\u901a\u308a\u3001\u96fb\u5353\u3067\u8a08\u7b97\u3067\u304d\u308b\u56db\u5247\u6f14\u7b97\u306e\u307f\u3067\u6c42\u3081\u3089\u308c\u307e\u3059\u3002<\/p>\n  <\/details>\n\n  <details class=\"rtk-faq\">\n    <summary><h3>\u30cb\u30fc\u30c8\u6a19\u6e96\u54c1\u3092\u6eb6\u89e3\u3059\u308b\u969b\u3001\u6eb6\u5a92\u91cf\u3092\u5909\u3048\u3066\u3082\u8a08\u7b97\u65b9\u6cd5\u306f\u540c\u3058\u3067\u3059\u304b\uff1f<\/h3><\/summary>\n    <p>\u540c\u3058\u3067\u3059\u3002\u91cf\u308a\u53d6\u3063\u305f\u8cea\u91cf\u3068\u6eb6\u89e3\u306b\u4f7f\u7528\u3057\u305f\u6eb6\u5a92\u91cf\u304b\u3089\u6eb6\u6db2\u6fc3\u5ea6\uff08mg\/mL\uff09\u3092\u7b97\u51fa\u3057\u3001\u305d\u306e\u5024\u3092\u57fa\u6e96\u306b\u91cd\u91cf%\u304b\u3089\u00b5g\/mL\u3078\u5909\u63db\u3057\u307e\u3059\u3002\u6eb6\u5a92\u91cf\u3092\u5909\u3048\u305f\u5834\u5408\u306f\u3001\u305d\u306e\u90fd\u5ea6\u6eb6\u6db2\u6fc3\u5ea6\u3092\u518d\u8a08\u7b97\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n  <\/details><\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>The first time I was asked by a customer about how to convert % by weight of one of our FAME reference standards to &micro;g\/mL, I needed to ask for some help. Because we (tech service) occasionally get asked this&#8230;<\/p>\n","protected":false},"author":73,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2399,2374],"resource-technique":[],"ppma_author":[582],"class_list":["post-100438","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","product-library-liquid-reference-standards","product-library-reference-standard-products"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"product-library":[{"value":2399,"label":"Liquid Reference Standards"},{"value":2374,"label":"Reference Standard Products"}]},"featured_image_src_large":false,"author_info":{"display_name":"Ayumi Suzuki","author_link":"https:\/\/discover.restek.com\/ja\/author\/ayumi-suzuki\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":2823,"user_id":0,"is_guest":1,"slug":"alan-sensue","display_name":"Alan Sensue","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/100438","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/73"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=100438"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/100438\/revisions"}],"predecessor-version":[{"id":100723,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/100438\/revisions\/100723"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=100438"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=100438"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=100438"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=100438"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=100438"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=100438"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=100438"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=100438"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=100438"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}