{"id":100766,"date":"2026-07-30T20:43:42","date_gmt":"2026-07-30T20:43:42","guid":{"rendered":"https:\/\/discover.restek.com\/?p=100766"},"modified":"2026-08-31T02:30:36","modified_gmt":"2026-08-31T02:30:36","slug":"why-does-the-cofa-for-my-pfas-reference-standard-state-a-volume-of-1-2-ml","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq-ja\/gnot5780-ja\/why-does-the-cofa-for-my-pfas-reference-standard-state-a-volume-of-1-2-ml","title":{"rendered":"PFAS\u6a19\u6e96\u6eb6\u6db2\u306eCoA\u306b\u300c>1.2 mL\u300d\u3068\u8a18\u8f09\u3055\u308c\u308b\u306e\u306f\u306a\u305c\u304b"},"content":{"rendered":"\n<style data-wp-block-html=\"css\">\n<style>\n.rtk-article { line-height: 1.8; font-size: 16px; }\n\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n\n.rtk-article h2 {\n  margin-top: 4em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n\n.rtk-article h3 {\n  margin-top: 2.4em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n\n.rtk-article p {\n  font-size: 18px;\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n\n.rtk-article a {\n  font-size: inherit !important;\n}\n\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n\n.rtk-article .rtk-lead {\n  font-size: 18px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n\n.rtk-article blockquote.rtk-voc {\n  position: relative;\n  border-left: 4px solid #00265d;\n  background: #f7f8f9;\n  padding: 18px 22px 18px 30px;\n  margin: 2em 0;\n  font-style: italic;\n  color: #333;\n}\n.rtk-article blockquote.rtk-voc p { margin-bottom: 0.4em; }\n.rtk-article blockquote.rtk-voc cite {\n  display: block;\n  font-style: normal;\n  font-size: 13px;\n  color: #4a4a4a;\n}\n\n.rtk-article .rtk-coa-list {\n  list-style: none;\n  padding: 0;\n}\n.rtk-article .rtk-coa-list li {\n  background: #fafbfc;\n  border: 1px solid #e1e8ec;\n  border-radius: 6px;\n  padding: 14px 18px;\n  margin-bottom: 12px;\n}\n\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 2.8em; }\n  .rtk-article h3 { margin-top: 1.8em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout,\n  .rtk-article blockquote.rtk-voc {\n    padding: 14px 16px;\n  }\n}\n<\/style>\n\n<div class=\"rtk-article\">\n\n<div class=\"rtk-intro\">\n<p class=\"rtk-lead\">Restek\u88fd\u306ePFAS\u6a19\u6e96\u6eb6\u6db2\u306f\u3001\u79fb\u3057\u66ff\u3048\u306b\u304a\u3051\u308b\u640d\u5931\u3092\u8003\u616e\u3057\u3001\u5404\u30a2\u30f3\u30d7\u30eb\u306b1.2 mL\u3092\u8d85\u3048\u308b\u6eb6\u6db2\u3092\u5145\u586b\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<\/div>\n\n<p>Restek\u304c\u88fd\u9020\u3059\u308b\u3059\u3079\u3066\u306ePFAS\u6a19\u6e96\u6eb6\u6db2\u306f\u3001\u5404\u30a2\u30f3\u30d7\u30eb\u306b1.2 mL\u3092\u8d85\u3048\u308b\u6eb6\u6db2\u3092\u5145\u586b\u3057\u3066\u3044\u307e\u3059\u3002\u30d4\u30da\u30c3\u30c8\u64cd\u4f5c\u3084\u79fb\u3057\u66ff\u3048\u3067\u751f\u3058\u308b\u308f\u305a\u304b\u306a\u640d\u5931\u3092\u8003\u616e\u3057\u3066\u3082\u30011.2 mL\u4ee5\u4e0a\u306e\u4f7f\u7528\u53ef\u80fd\u306a\u91cf\u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u3067\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u5206\u6790\u8a3c\u660e\u66f8\uff08CoA\uff09\u306b\u306f\u300c&gt;1.2 mL\u300d\u3068\u8a18\u8f09\u3055\u308c\u307e\u3059\u3002<\/p>\n\n<p><strong>\u3010\u88dc\u8db3\u3011<\/strong>Restek\u3067\u306f\u3001\u5404PFAS\u30a2\u30f3\u30d7\u30eb\u306b\u5145\u586b\u3059\u308b\u6a19\u6e96\u6eb6\u6db2\u306e\u91cf\u3092\u5909\u66f4\u3057\u3066\u3044\u307e\u305b\u3093\u3002\u8868\u8a18\u304c1 mL\u3068\u306a\u3063\u3066\u3044\u308b\u88fd\u54c1\u3082\u542b\u3081\u3001Restek\u304c\u88fd\u9020\u3059\u308b\u3059\u3079\u3066\u306ePFAS\u6a19\u6e96\u6eb6\u6db2\u306b\u306f1.2 mL\u3092\u8d85\u3048\u308b\u6eb6\u6db2\u304c\u5145\u586b\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n<\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Restek\u88fd\u306ePFAS\u6a19\u6e96\u6eb6\u6db2\u306f\u3001\u79fb\u3057\u66ff\u3048\u306b\u304a\u3051\u308b\u640d\u5931\u3092\u8003\u616e\u3057\u3001\u5404\u30a2\u30f3\u30d7\u30eb\u306b1.2 mL\u3092\u8d85\u3048\u308b\u6eb6\u6db2\u3092\u5145\u586b\u3057\u3066\u3044\u307e\u3059\u3002 Restek\u304c\u88fd\u9020\u3059\u308b\u3059\u3079\u3066\u306ePFAS\u6a19\u6e96\u6eb6\u6db2\u306f\u3001\u5404\u30a2\u30f3\u30d7\u30eb\u306b1.2 mL\u3092\u8d85\u3048\u308b\u6eb6\u6db2\u3092\u5145\u586b\u3057\u3066\u3044\u307e\u3059\u3002\u30d4\u30da\u30c3\u30c8\u64cd\u4f5c\u3084\u79fb\u3057\u66ff\u3048\u3067\u751f\u3058\u308b\u308f\u305a\u304b\u306a\u640d\u5931\u3092\u8003\u616e\u3057\u3066\u3082\u30011.2 mL\u4ee5\u4e0a\u306e\u4f7f\u7528\u53ef\u80fd\u306a\u91cf\u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u3067\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u5206\u6790\u8a3c\u660e\u66f8\uff08CoA\uff09\u306b\u306f\u300c&gt;1.2 mL\u300d\u3068\u8a18\u8f09\u3055\u308c\u307e\u3059\u3002 \u3010\u88dc\u8db3\u3011Restek\u3067\u306f\u3001\u5404PFAS\u30a2\u30f3\u30d7\u30eb\u306b\u5145\u586b\u3059\u308b\u6a19\u6e96\u6eb6\u6db2\u306e\u91cf\u3092\u5909\u66f4\u3057\u3066\u3044\u307e\u305b\u3093\u3002\u8868\u8a18\u304c1 mL\u3068\u306a\u3063\u3066\u3044\u308b\u88fd\u54c1\u3082\u542b\u3081\u3001Restek\u304c\u88fd\u9020\u3059\u308b\u3059\u3079\u3066\u306ePFAS\u6a19\u6e96\u6eb6\u6db2\u306b\u306f1.2 mL\u3092\u8d85\u3048\u308b\u6eb6\u6db2\u304c\u5145\u586b\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n","protected":false},"author":73,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[804],"tags":[2721],"industries-application":[2288,2271],"post-badge":[],"resource-type":[],"product-library":[2579,2554],"resource-technique":[],"ppma_author":[2814],"class_list":["post-100766","post","type-post","status-publish","format-standard","hentry","category-faq-ja","tag-frequently-asked-questions-reference-standards-japan","industries-application-pfas-testing-ja","industries-application-environmental-ja","product-library-liquid-reference-standards-ja","product-library-reference-standard-products-ja"],"acf":[],"taxonomy_info":{"category":[{"value":804,"label":"FAQ"}],"post_tag":[{"value":2721,"label":"\u3088\u304f\u3042\u308b\u8cea\u554f\uff08FAQ\uff09\uff1a Reference Standard"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"}],"product-library":[{"value":2579,"label":"\u6a19\u6e96\u6eb6\u6db2"},{"value":2554,"label":"\u6a19\u6e96\u7269\u8cea"}]},"featured_image_src_large":false,"author_info":{"display_name":"Ayumi Suzuki","author_link":"https:\/\/discover.restek.com\/ja\/author\/ayumi-suzuki\/"},"comment_info":0,"category_info":[{"term_id":804,"name":"FAQ","slug":"faq-ja","term_group":0,"term_taxonomy_id":804,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":804,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq-ja","category_parent":0}],"tag_info":[{"term_id":2721,"name":"\u3088\u304f\u3042\u308b\u8cea\u554f\uff08FAQ\uff09\uff1a Reference Standard","slug":"frequently-asked-questions-reference-standards-japan","term_group":0,"term_taxonomy_id":2721,"taxonomy":"post_tag","description":"","parent":0,"count":58,"filter":"raw"}],"authors":[{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/100766","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/73"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=100766"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/100766\/revisions"}],"predecessor-version":[{"id":102315,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/100766\/revisions\/102315"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=100766"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=100766"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=100766"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=100766"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=100766"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=100766"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=100766"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=100766"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=100766"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}