{"id":101920,"date":"2026-07-14T15:00:00","date_gmt":"2026-07-14T15:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=101920"},"modified":"2026-08-27T02:22:02","modified_gmt":"2026-08-27T02:22:02","slug":"astm-petrochemical-method-chromatography-product-guide","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles\/pcar2082-ja\/astm-petrochemical-method-chromatography-product-guide","title":{"rendered":"ASTM\u77f3\u6cb9\u5316\u5b66\u5206\u6790\u6cd5\u5bfe\u5fdc \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u88fd\u54c1\u30ac\u30a4\u30c9"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">Restek\u306f\u3001\u77f3\u6cb9\u5316\u5b66\u5206\u6790\u306b\u304a\u3051\u308b\u7dcf\u5408\u7684\u306a\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002SimDist\u3001DHA\u3001\u30ac\u30bd\u30ea\u30f3\u7d44\u6210\u5206\u6790\u306a\u3069\u3001\u4ee3\u8868\u7684\u306a\u77f3\u6cb9\u5206\u6790\u306b\u5bfe\u5fdc\u3057\u305fASTM Method\u6e96\u62e0\u306e\u88fd\u54c1\u30ac\u30a4\u30c9\u3092\u3053\u3061\u3089\u3067\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u76ee\u7684\u306b\u5fdc\u3058\u3066\u3001\u6700\u9069\u306aGC\u30ab\u30e9\u30e0\u3068\u6a19\u6e96\u8a66\u85ac\u3092\u7c21\u5358\u306b\u898b\u3064\u3051\u3066\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u8a73\u3057\u3044\u60c5\u5831\u3092\u3054\u5e0c\u671b\u306e\u5834\u5408\u306f\u3001\u77f3\u6cb9\u5316\u5b66\u5206\u6790\u306b\u7cbe\u901a\u3057\u305f\u5f0a\u793e\u306e\u5c02\u9580\u30b9\u30bf\u30c3\u30d5\u307e\u3067<a href=\"https:\/\/restek.com\/contact-us\" data-type=\"link\" data-id=\"restek.com\/contact-us\" target=\"_blank\" rel=\"noreferrer noopener\">\u304a\u554f\u5408\u305b<\/a>\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"5\"><strong>SimDist\u3000\uff08(\u9ad8\u6e29) \u7591\u4f3c\u84b8\u7559\uff09<\/strong><\/td><\/tr><tr><td><strong>Method<\/strong><\/td><td><strong>Method\u540d<\/strong><\/td><td><strong>\u30ab\u30e9\u30e0<\/strong><\/td><td><strong>\u6a19\u6e96\u8a66\u85ac<\/strong><\/td><td><strong>\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0<\/strong><\/td><\/tr><tr><td>D2887<\/td><td>Standard Test Method for Boiling Range Distribution of Petroleum Fractions by Gas Chromatography (C5\u2013C44)<\/td><td>MXT-2887, Siltek-treated stainless steel<br>10 m x 0.53 mm x 2.65 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70199\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70199<\/a> <em>or<\/em> MXT-1HT SimDist, Siltek-treated stainless steel<br>10 m x 0.53 mm x 2.65 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70132\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70132<\/a> <em>or<\/em> Rtx-2887 Column<br>10 m x 0.53 mm x 2.65 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10199\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10199<\/a> &nbsp;<\/td><td>ASTM D2887-12 Calibration Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/31674\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 31674<\/a> Polywax Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/36224\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 36224\u201336227<\/a> D2887 Calibration Mix<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/31222\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 31222<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC00750\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC00750<\/a><\/td><\/tr><tr><td>D2887B Accelerated<\/td><td>Standard Test Method for Boiling Range Distribution of Petroleum Fractions by Gas Chromatography (C5\u2013C44)<\/td><td>MXT-1HT SimDist Column<br>10 m x 0.53 mm x 0.88 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70134\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70134<\/a> <em>or<\/em> MXT-1HT SimDist Column<br>5 m x 0.53 mm x 2.65 \u00b5m<br>custom column #573912<\/td><td>ASTM D2887-12 Calibration Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/31674\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 31674<\/a> Polywax Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/36224\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 36224\u201336227<\/a> D2887 Calibration Mix<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/31222\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 31222<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1303\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1303<\/a><\/td><\/tr><tr><td>D7213<\/td><td>Standard Test Method for Boiling Range Distribution of Petroleum Distillates in the Boiling Range from 100 to 615 \u00b0C by Gas Chromatography (C5\u2013C60)<\/td><td>MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.10 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70112\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70112<\/a> <em>or<\/em> MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.20 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70115\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70115<\/a> <em>or<\/em> MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.88 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70131\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70131<\/a><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1285\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1285<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1191\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1191<\/a><\/td><\/tr><tr><td>D6352<\/td><td>Standard Test Method for Boiling Range Distribution of Petroleum Distillates in Boiling Range from 174 to 700 \u00b0C by Gas Chromatography (C10\u2013C90)<\/td><td>MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.10 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70112\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70112<\/a> <em>or<\/em> MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.20 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70115\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70115<\/a><\/td><td>Polywax Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/36224\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 36224\u201336227<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1188\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1188<\/a><\/td><\/tr><tr><td>D7398<\/td><td>Standard Test Method for Boiling Range Distribution of Fatty Acid Methyl Esters (FAME) in the Boiling Range from 100 to<br>615 \u00b0C by Gas Chromatography<\/td><td>MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.88 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70131\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70131<\/a><\/td><td>Polywax Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/36224\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 36224\u201336227<\/a> &nbsp;<\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1285\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1285<\/a><\/td><\/tr><tr><td>D7500<\/td><td>Standard Test Method for Determination of Boiling Range Distribution of Distillates and Lubricating Base Oils in Boiling Range from 100 to 735 \u00b0C by Gas Chromatography (C7\u2013C110)<\/td><td>MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.10 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70112\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70112<\/a> <em>or<\/em> MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.20 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70115\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70115<\/a><\/td><td>&nbsp; Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/36224\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 36224\u201336227<\/a> &nbsp;<\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1164\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1164<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1165\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1165<\/a><\/td><\/tr><tr><td>D7169<\/td><td>Standard Test Method for Boiling Point Distribution of Samples with Residues Such as Crude Oils and Atmospheric and Vacuum Residues by High-Temperature Gas Chromatography<\/td><td>MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.10 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70112\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70112<\/a> <em>or<\/em> MXT-1HT SimDist, Siltek-treated stainless steel<br>5 m x 0.53 mm x 0.20 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70115\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70115<\/a><\/td><td>Polywax Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/36224\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 36224\u201336227<\/a> &nbsp;<\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1308\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1308<\/a><\/td><\/tr><tr><td>D7096 <em>(replaces D3710)<\/em><\/td><td>Standard Test Method for Determination of the Boiling Range Distribution of Gasoline by Wide-Bore Capillary Gas Chromatography<\/td><td>MXT-1, Siltek-treated stainless steel<br>15 m x 0.53 mm x 5.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70177\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70177<\/a> <em>or<\/em> MXT-1, Siltek-treated stainless steel<br>30 m x 0.53 mm x 5.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70179\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70179<\/a><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a> <em>or<\/em> D3710-95 Calibration Mix<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/31223\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 31223<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1326\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1326<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1327\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1327<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1328\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1328<\/a><\/td><\/tr><tr><td colspan=\"5\"><strong>DHA (\u8a73\u7d30\u306a\u70ad\u5316\u6c34\u7d20\u5206\u6790)<\/strong><\/td><\/tr><tr><td><strong>Method<\/strong><\/td><td><strong>Method<\/strong>\u540d<\/td><td><strong>\u30ab\u30e9\u30e0<\/strong><\/td><td><strong>\u6a19\u6e96\u8a66\u85ac<\/strong><\/td><td><strong>\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0<\/strong><\/td><\/tr><tr><td>D5134<\/td><td>Standard Test Method for Detailed Analysis of Petroleum Naphthas through&nbsp;n-Nonane by Capillary Gas Chromatography<\/td><td>Rtx-DHA-50<br>50 m x 0.20 mm x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10147\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10147<\/a><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1318\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1318<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1319\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1319<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1320\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1320<\/a><\/td><\/tr><tr><td>D6729<\/td><td>Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 100-Meter Capillary High-Resolution Gas Chromatography<\/td><td>Rtx-DHA-100<br>100 m x 0.25 mm x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10148\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10148<\/a><\/td><td>DHA Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/33034\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 33034<\/a><br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/30725\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 30725\u201330731<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1322\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1322<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1323\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1323<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1324\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1324<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1325\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1325<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1330\" target=\"_blank\" rel=\"noopener\">GC_PC1330<\/a><\/td><\/tr><tr><td>D6730<\/td><td>Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 100\u2013Meter Capillary (with precolumn) High-Resolution Gas Chromatography<\/td><td>Rtx-DHA-100<br>100 m x 0.25 mm x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10148\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10148<\/a> <em>and<\/em> Rtx-5 DHA Tuning<br>5 m x 0.25 mm x 1.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10165\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10165<\/a><\/td><td>DHA Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/33034\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 33034<\/a><br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/30725\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 30725\u201330731<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1284\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1284<\/a><\/td><\/tr><tr><td>D6733<\/td><td>Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 50-Meter Capillary High-Resolution Gas Chromatography<\/td><td>Rtx-DHA-50<br>50 m x 0.20 mm x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10147\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10147<\/a><\/td><td>DHA Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/33034\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 33034<\/a><br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/30725\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 30725\u201330731<\/a><\/td><td>&nbsp;<\/td><\/tr><tr><td colspan=\"5\"><strong>\u30ac\u30bd\u30ea\u30f3\uff08\u5b8c\u6210\u54c1\uff09<\/strong><\/td><\/tr><tr><td><strong>Method<\/strong><\/td><td><strong>Method\u540d<\/strong><\/td><td><strong>\u30ab\u30e9\u30e0<\/strong><\/td><td><strong>\u6a19\u6e96\u8a66\u85ac<\/strong><\/td><td><strong>\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0<\/strong><\/td><\/tr><tr><td>D3606<\/td><td>Standard Test Method for Determination of Benzene and Toluene in Spark Ignition Fuels by Gas Chromatography<\/td><td>D3606 Packed GC Column Set, Sulfinert, General Configuration<br><em>&#8211; <a href=\"https:\/\/www.restek.com\/p\/83606-800\" target=\"_blank\" rel=\"noreferrer noopener\">cat.#83606-800<\/a><\/em><br><em><br>Specified in the D3606 method addendum\u2014includes:<\/em> <em>&#8211; Column 1: Backflush column<br>6&#8242; (1.8 m), 1\/8&#8243; OD, 2.0 mm ID<br><br>and<\/em> <em>&#8211; Column 2: proprietary packing<br>16&#8242; (4.9 m), 1\/8&#8243; OD, 2.0 mm ID<br><br><br><\/em>D3606 GC Capillary Column Set<em><br>&#8211; <a href=\"http:\/\/restek.com\/p\/118-D3606\" data-type=\"link\" data-id=\"restek.com\/p\/118-D3606\" target=\"_blank\" rel=\"noopener\">cat.#<\/a><a href=\"https:\/\/www.restek.com\/p\/118-D3606\" target=\"_blank\" rel=\"noreferrer noopener\"><\/a><a href=\"https:\/\/restek.com\/p\/118-D3606\" data-type=\"link\" data-id=\"https:\/\/restek.com\/p\/118-D3606\" target=\"_blank\" rel=\"noopener\">118-D3606<\/a><br><\/em> <em>&#8211; Column 1: Rxi-1ms Capillary Column,&nbsp;<br>30 m, 0.25 mm ID, 0.50 \u00b5m<br>(<a href=\"https:\/\/www.restek.com\/p\/13338\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 13338<\/a>)<br><br>and<br><br>&nbsp;&#8211; Column 2: Stabilwax GC Capillary Column, 60 m, 0.32 mm ID, 1.00 \u00b5m (<a href=\"https:\/\/www.restek.com\/p\/10657\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10657<\/a>)<\/em><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><a href=\"p\/30647\"><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC01121\" target=\"_blank\" rel=\"noreferrer noopener\">PC01121<\/a><\/td><\/tr><tr><td>D4815<\/td><td>Standard Test Method for Determination of MTBE, ETBE, TAME, DIPE, tertiary-Amyl Alcohol, and C1 to C4 Alcohols in Gasoline by Gas Chromatography (Oxygenates)<\/td><td>Micropacked with 20% TCEP on 80\/100 Chromosorb PAW<br>0.56 m x 0.75 mm ID x 1\/16&#8243; OD<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/19040\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 19040<\/a> <em>and<\/em> Rtx-1<br>30 m x 0.53 mm x 3.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10185\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10185<\/a><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC00194\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC00194<\/a><\/td><\/tr><tr><td>D5580<\/td><td>Standard Test Method for Determination of Benzene, Toluene, Ethylbenzene,&nbsp;<em>p\/m<\/em>-Xylene,&nbsp;o-Xylene, C9 and Heavier Aromatics, and Total Aromatics in Finished Gasoline by Gas Chromatography<\/td><td>Micropacked with 20% TCEP on 80\/100 Chromosorb PAW<br>0.56 m x 0.75 mm ID x 1\/16&#8243; OD<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/19040\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 19040<\/a> <em>and<\/em> Rtx-1<br>30 m x 0.53 mm x 5.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10179\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10179<\/a><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td>&nbsp;<\/td><\/tr><tr><td>D5501<\/td><td>Standard Test Method for Determination of Ethanol Content of Denatured Fuel Ethanol by Gas Chromatography<\/td><td>Rtx-DHA-150<br>150 m x 0.25 mm x 1.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10149\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10149<\/a> <em>or<\/em> Rtx-DHA-100<br>100 m x 0.25 mm x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10148\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10148<\/a><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1144\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1144<\/a><\/td><\/tr><tr><td>D8071<\/td><td>Standard Test Method for Determination of Hydrocarbon Group Types and Select Hydrocarbon and Oxygenate Compounds in Automotive Spark-Ignition Engine Fuel Using Gas Chromatography with Vacuum Ultraviolet Absorption Spectroscopy Detection (GC-VUV)<\/td><td>Rxi-1ms<br>30 m x 0.25 mm x 0.25 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/13323\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 13323<\/a> &nbsp;<\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1358\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1358<\/a><\/td><\/tr><tr><td colspan=\"5\"><strong>\u30d0\u30a4\u30aa\u30c7\u30a3\u30fc\u30bc\u30eb<\/strong><\/td><\/tr><tr><td><strong>Method<\/strong><\/td><td><strong>Method\u540d<\/strong><\/td><td><strong>\u30ab\u30e9\u30e0<\/strong><\/td><td><strong>\u6a19\u6e96\u8a66\u85ac<\/strong><\/td><td><strong>\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0<\/strong><\/td><\/tr><tr><td>D6584<\/td><td>Test Method for Determination of Free and Total Glycerin in B-100 Biodiesel Methyl Esters by Gas Chromatography<\/td><td>MXT-Biodiesel TG, Siltek-treated stainless steel<br>14 m x 0.53 mm x 0.16 \u00b5m<br>with 2 m Integra-Gap<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70289\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70289<\/a> <em>or<\/em> MXT-Biodiesel TG, Siltek-treated stainless steel<br>15 m x 0.32 mm x 0.10 \u00b5m<br>with 2 m x 0.53 mm retention gap<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70291\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70291<\/a> <em>or<\/em> Rtx-Biodiesel TG<br>15 m x 0.32 mm x 0.10 \u00b5m<br>with 2 m x 0.53 mm retention gap<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10293\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10293<\/a><\/td><td>Biodiesel Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/31880\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 31880<\/a><br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/33020\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 33020\u201333026<\/a><br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/33032\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 33032\u201333033<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1293\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1293<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC00969\" target=\"_blank\" rel=\"noopener\">GC_PC00969<\/a><\/td><\/tr><tr><td colspan=\"5\"><strong>\u30b8\u30a7\u30c3\u30c8\u71c3\u6599<\/strong><\/td><\/tr><tr><td><strong>Method<\/strong><\/td><td><strong>Method\u540d<\/strong><\/td><td><strong>\u30ab\u30e9\u30e0<\/strong><\/td><td><strong>\u6a19\u6e96\u8a66\u85ac<\/strong><\/td><td><strong>\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0<\/strong><\/td><\/tr><tr><td>D8267<\/td><td>Standard Test Method for Determination of Saturated Hydrocarbon, Aromatic, and Diaromatic Content of Aviation Turbine Fuels Using Gas Chromatography with Vacuum Ultraviolet Absorption Spectroscopy Detection (GC-VUV)<\/td><td>Rxi-1ms<br>30 m x 0.25 mm x 0.25 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/13323\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 13323<\/a> &nbsp;<\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1359\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1359<\/a><\/td><\/tr><tr><td colspan=\"5\"><strong>\u5929\u7136\u30ac\u30b9<\/strong><\/td><\/tr><tr><td><strong>Method<\/strong><\/td><td><strong>Method\u540d<\/strong><\/td><td><strong>\u30ab\u30e9\u30e0<\/strong><\/td><td><strong>\u6a19\u6e96\u8a66\u85ac<\/strong><\/td><td><strong>\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0<\/strong><\/td><\/tr><tr><td>D1945<\/td><td>Standard Test Method for Analysis of Natural Gas by Gas Chromatography<\/td><td>MXT-Msieve 5A, Siltek-treated stainless steel<br>30 m x 0.53 mm x 50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/79723-273\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 79723-273<\/a> <em>and<\/em> MXT-Q-BOND, Siltek-treated stainless steel<br>30 m x 0.53 mm x 20 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/79716-273\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 79716-273<\/a><\/td><td>Natural Gas Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/34438\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 34438\u201334440<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1182\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1182<\/a><\/td><\/tr><tr><td colspan=\"5\"><strong>\u7cbe\u88fd\u30ac\u30b9<\/strong><\/td><\/tr><tr><td><strong>Method<\/strong><\/td><td><strong>Method\u540d<\/strong><\/td><td><strong>\u30ab\u30e9\u30e0<\/strong><\/td><td><strong>\u6a19\u6e96\u8a66\u85ac<\/strong><\/td><td><strong>\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0<\/strong><\/td><\/tr><tr><td>D2163<\/td><td>Standard Test Method for Determination of Hydrocarbons in Liquefied Petroleum (LP) Gases and Propane\/Propene Mixtures by Gas Chromatography<\/td><td>Rt-Alumina BOND\/Na<sub>2<\/sub>SO<sub>4<\/sub><br>50 m x 0.53 mm x 10 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/19756\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 19756<\/a><\/td><td>Refinery Gas Standards<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/34441\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 34441\u201334443<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1309\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1309<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1310\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1310<\/a><\/td><\/tr><tr><td>UOP 539<\/td><td>Standard Practice for Analysis of Reformed Gas by Gas Chromatography<\/td><td>2abc Refinery Gas Packed Column Set<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/88000-875\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 88000-875<\/a> <em>or<\/em> MXT-Msieve 5A, Siltek-treated stainless steel<br>30 m x 0.53 mm x 50 \u00b5m<br>&#8211;&nbsp;cat.# <a href=\"https:\/\/www.restek.com\/p\/79723-273\" target=\"_blank\" rel=\"noopener\">79723-273<\/a> <em>and<\/em> MXT-Q-BOND, Siltek-treated stainless steel<br>30 m x 0.53 mm x 20 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/79716\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 79716<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1182\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1182<\/a><\/td><\/tr><tr><td colspan=\"5\"><strong>\u4e0d\u7d14\u7269<\/strong><\/td><\/tr><tr><td><strong>Method<\/strong><\/td><td><strong>Method\u540d<\/strong><\/td><td><strong>\u30ab\u30e9\u30e0<\/strong><\/td><td><strong>\u6a19\u6e96\u8a66\u85ac<\/strong><\/td><td><strong>\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0<\/strong><\/td><\/tr><tr><td>D2593<\/td><td>Standard Test Method for Butadiene Purity and Hydrocarbon Impurities by Gas Chromatography<\/td><td>Rt-Alumina BOND\/MAPD<br>50 m x 0.53 mm x 10 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/19778\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 19778<\/a><\/td><td>Refinery Gas Standard #5<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/34443\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 34443<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1202\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1202<\/a><\/td><\/tr><tr><td>D2712<\/td><td>Standard Test Method for Hydrocarbon Traces in Propylene Concentrates by Gas Chromatography<\/td><td>Rt-Alumina BOND\/KCl<br>50 m x 0.53 mm x 10 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/19760\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 19760<\/a><\/td><td>Refinery Gas Standard #5<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/34443\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 34443<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC01142\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC01142<\/a><\/td><\/tr><tr><td>D6159<\/td><td>Standard Test Method for Determination of Hydrocarbon Impurities in Ethylene by Gas Chromatography<\/td><td>Rt-Alumina BOND\/KCl<br>50 m x 0.53 mm x 10 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/19760\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 19760<\/a> <em>and<\/em> Rtx-1<br>30 m x 0.53 mm x 5.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10179\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10179<\/a><\/td><td>Refinery Gas Standard #5<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/34443\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 34443<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC01110\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC01110<\/a><\/td><\/tr><tr><td>D5441<\/td><td>Standard Test Method for Analysis of Methyl&nbsp;<em>Tert<\/em>-Butyl Ether (MTBE) by Gas Chromatography<\/td><td>Rtx-DHA-100<br>100 m x 0.25 mm x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10148\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10148<\/a> <em>or<\/em> Rtx-DHA-50<br>50 m x 0.20 mm x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10147\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10147<\/a> <em>or<\/em> Rtx-DHA-150<br>150 m x 0.25 mm x 1.0 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10149\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10149<\/a><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1268\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1268<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1270\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1270<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1269\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1269<\/a><\/td><\/tr><tr><td>D8311<\/td><td>Test Method for Impurities in Monoethylene Glycol by Gas Chromatography with Normalization<\/td><td>Rxi-624Sil MS<br>30 m x 0.32 mm ID x 1.80 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/13870\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 13870<\/a><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><\/td><\/tr><tr><td>E2409<\/td><td>Test Method for Glycol Impurities in Mono-, Di-, Tri- and Tetraethylene Glycol (Gas Chromatographic Method)<\/td><td>Rtx-Wax<br>15 m x 0.53 mm ID x 1.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/12452\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 12452<\/a><\/td><td><a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><\/td><\/tr><tr><td colspan=\"5\"><strong>\u786b\u9ec4<\/strong><\/td><\/tr><tr><td><strong>Method<\/strong><\/td><td><strong>Method\u540d<\/strong><\/td><td><strong>\u30ab\u30e9\u30e0<\/strong><\/td><td><strong>\u6a19\u6e96\u8a66\u85ac<\/strong><\/td><td><strong>\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0<\/strong><\/td><\/tr><tr><td>D6228<\/td><td>Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Flame Photometric Detection<\/td><td>Rtx-1<br>60 m x 0.53 mm x 7.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10193\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10193<\/a> <em>or<\/em> MXT-1, Siltek-treated stainless steel<br>60 m x 0.53 mm x 7.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/70193\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 70193<\/a> <em>or<\/em> Rtx-1<br>60 m x 0.32 mm x 5.0 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10180\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10180<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1223\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1223<\/a><\/td><\/tr><tr><td>D5623<\/td><td>Standard Test Method for Sulfur Compounds in Light Petroleum Liquids by Gas Chromatography and Sulfur Selective Detection<\/td><td>Rtx-1<br>30 m x 0.32 mm x 4.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10198\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10198<\/a><\/td><td>Request today<br>(<a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noopener\">gas<\/a>,&nbsp;<a href=\"https:\/\/standards.restek.com\/forms\/custom-reference-standards-form-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">liquid<\/a>)<\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1271\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1271<\/a> <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC00198\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC00198<\/a><\/td><\/tr><tr><td colspan=\"5\"><strong>\u5de5\u696d\u7528\u5316\u5b66\u7269\u8cea<\/strong><\/td><\/tr><tr><td><strong>Method<\/strong><\/td><td><strong>Method\u540d<\/strong><\/td><td><strong>\u30ab\u30e9\u30e0<\/strong><\/td><td><strong>\u6a19\u6e96\u8a66\u85ac<\/strong><\/td><td><strong>\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0<\/strong><\/td><\/tr><tr><td>D5917<\/td><td>Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and External Calibration<\/td><td>Stabilwax<br>60 m x 0.32 mm x 0.25 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10627\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10627<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1355\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1355<\/a><br><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1352\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1352<\/a><br><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1353\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1353<\/a><br><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1354\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1354<\/a><\/td><\/tr><tr><td>D7266<\/td><td>Standard Test Method for Analysis of Cyclohexane by Gas Chromatography (External Standard)<\/td><td>Rtx-DHA-100<br>100 m x 0.25 mm x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10148\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10148<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1356\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1356<\/a><\/td><\/tr><tr><td>D7504<\/td><td>Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and Effective Carbon Number<\/td><td>Stabilwax<br>60 m x 0.32 mm x 0.25 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10627\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10627<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1352\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1352<\/a><br><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1353\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1353<\/a><br><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1354\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1354<\/a><br><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1355\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1355<\/a><\/td><\/tr><tr><td>D7871<\/td><td>Standard Test Method for Analysis of Cyclohexane by Gas Chromatography (Effective Carbon Number)<\/td><td>Rtx-DHA-100<br>100 m x 0.25 mm x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10148\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 10148<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1356\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1356<\/a><\/td><\/tr><tr><td>D7011<\/td><td>Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography and Sulfur Selective Detection<\/td><td>Rtx-WAX<br>30 m x 0.32 mm x 1.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/12454\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 12454<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1357\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1357<\/a><\/td><\/tr><tr><td>D6144<\/td><td>Standard Test Method for Analysis of AMS (a-Methylstyrene) by Capillary Gas Chromatography<\/td><td>Rtx-1<br>60 m x 0.32 mm x 1.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10157\" target=\"_blank\" rel=\"noopener\">cat.# 10157<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1351\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1351<\/a><\/td><\/tr><tr><td>D7057<\/td><td>Standard Test Method for Analysis of Isopropylbenzene (Cumene) by Gas Chromatography (External Standard)<\/td><td>Rtx-1<br>60 m x 0.32 mm x 1.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10157\" target=\"_blank\" rel=\"noopener\">cat.# 10157<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1350\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1350<\/a><\/td><\/tr><tr><td>D5310<\/td><td>Standard Test Method for Tar Acid Composition by Capillary Gas Chromatography<\/td><td>Rxi 5MS<br>30 m x 0.53 mm x 1.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/13423\" target=\"_blank\" rel=\"noopener\">cat.# 13423<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1371\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1371<\/a><\/td><\/tr><tr><td>D3329<\/td><td>Standard Test Method for Purity of Methyl Isobutyl Ketone by Gas Chromatography<\/td><td>Stabilwax<br>30 m x 0.25 mm x 1.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10655\" target=\"_blank\" rel=\"noreferrer noopener\">cat. #10655<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1373\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1373<\/a><\/td><\/tr><tr><td>D7090<\/td><td>Standard Test Method for Purity of Isophorone by Capillary Gas Chromatography<\/td><td>Rtx &#8211; WAX<br>30 m x 0.32 mm x 0.5 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/12439\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 12439<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_PC1369\" target=\"_blank\" rel=\"noreferrer noopener\">GC_PC1369<\/a><\/td><\/tr><tr><td>D3893<\/td><td>Standard Test Method for Purity of Methyl Amyl Ketone and Methyl Isoamyl Ketone by Gas Chromatography<\/td><td>Stabilwax<br>30 m x 0.53 mm x 1.00 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/10655\" target=\"_blank\" rel=\"noreferrer noopener\">cat. #10655<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td>&nbsp;<\/td><\/tr><tr><td>D6142<\/td><td>Test Method Analysis of Phenol by Capillary Gas Chromatography<\/td><td>Stabilwax-DA<br>50 m x 0.32 mm ID x 0.50 \u00b5m<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/11042-105\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 11042-105<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><\/td><\/tr><tr><td>D8266<\/td><td>Test Method for Analysis of Bisphenol A (4,4&#8242;-Isopropylidenediphenol)<\/td><td>Ultra C18<br>5 \u00b5m x 250 x 4.6 mm<br>&#8211;&nbsp;<a href=\"https:\/\/www.restek.com\/p\/9174575\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 9174575<\/a><\/td><td><a href=\"https:\/\/forms.restek.com\/220966034742052\" target=\"_blank\" rel=\"noreferrer noopener\">Request today<\/a><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Restek\u306f\u3001\u77f3\u6cb9\u5316\u5b66\u5206\u6790\u306b\u304a\u3051\u308b\u7dcf\u5408\u7684\u306a\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002SimDist\u3001DHA\u3001\u30ac\u30bd\u30ea\u30f3\u7d44\u6210\u5206\u6790\u306a\u3069\u3001\u4ee3\u8868\u7684\u306a\u77f3\u6cb9\u5206\u6790\u306b\u5bfe\u5fdc\u3057\u305fASTM Method\u6e96\u62e0\u306e\u88fd\u54c1\u30ac\u30a4\u30c9\u3092\u3053\u3061\u3089\u3067\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u76ee\u7684\u306b\u5fdc\u3058\u3066\u3001\u6700\u9069\u306aGC\u30ab\u30e9\u30e0\u3068\u6a19\u6e96\u8a66\u85ac\u3092\u7c21\u5358\u306b\u898b\u3064\u3051\u3066\u3044\u305f\u3060\u3051\u307e\u3059\u3002 \u8a73\u3057\u3044\u60c5\u5831\u3092\u3054\u5e0c\u671b\u306e\u5834\u5408\u306f\u3001\u77f3\u6cb9\u5316\u5b66\u5206\u6790\u306b\u7cbe\u901a\u3057\u305f\u5f0a\u793e\u306e\u5c02\u9580\u30b9\u30bf\u30c3\u30d5\u307e\u3067\u304a\u554f\u5408\u305b\u304f\u3060\u3055\u3044\u3002 SimDist\u3000\uff08(\u9ad8\u6e29) \u7591\u4f3c\u84b8\u7559\uff09 Method Method\u540d \u30ab\u30e9\u30e0 \u6a19\u6e96\u8a66\u85ac \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0 D2887 Standard Test Method for Boiling Range Distribution of Petroleum Fractions by Gas Chromatography (C5\u2013C44) MXT-2887, Siltek-treated stainless steel10 m x 0.53 mm x 2.65 \u00b5m&#8211;&nbsp;cat.# 70199 or MXT-1HT SimDist, Siltek-treated stainless steel10 m x 0.53 mm x 2.65 \u00b5m&#8211;&nbsp;cat.# 70132 or Rtx-2887 Column10 m&#8230;<\/p>\n","protected":false},"author":73,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[7],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[567],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-101920","post","type-post","status-publish","format-standard","hentry","category-articles","resource-type-selection-guides"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"}],"resource-type":[{"value":567,"label":"Selection Guides"}]},"featured_image_src_large":false,"author_info":{"display_name":"Ayumi Suzuki","author_link":"https:\/\/discover.restek.com\/ja\/author\/ayumi-suzuki\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":7,"category_count":511,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/101920","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/73"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=101920"}],"version-history":[{"count":7,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/101920\/revisions"}],"predecessor-version":[{"id":101927,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/101920\/revisions\/101927"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=101920"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=101920"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=101920"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=101920"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=101920"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=101920"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=101920"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=101920"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=101920"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}