{"id":102489,"date":"2026-06-11T16:47:46","date_gmt":"2026-06-11T16:47:46","guid":{"rendered":"https:\/\/discover.restek.com\/?p=102489"},"modified":"2026-10-02T03:12:34","modified_gmt":"2026-10-02T03:12:34","slug":"hot-topics-in-pesticides-analysis-cracking-the-toughest-food-matrices-with-advanced-gc-column-technology","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs\/fsbl5692-ja\/hot-topics-in-pesticides-analysis-cracking-the-toughest-food-matrices-with-advanced-gc-column-technology","title":{"rendered":"\u6b8b\u7559\u8fb2\u85ac\u5206\u6790\u306e\u6700\u524d\u7dda\uff5c\u9ad8\u5ea6\u306aGC\u30ab\u30e9\u30e0\u6280\u8853\u3067\u6311\u3080\u98df\u54c1\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u5206\u6790\u306e\u8ab2\u984c"},"content":{"rendered":"\n<style data-wp-block-html=\"css\">\n<style>\n\/* ===== \u30d9\u30fc\u30b9\uff1artk-article-style.css\uff08\u5171\u901a\uff09 ===== *\/\n.rtk-article { line-height: 1.8; font-size: 17px; }\n\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n\n.rtk-article h2 {\n  margin-top: 4em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n\n.rtk-article h3 {\n  margin-top: 2.4em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n\n.rtk-article p {\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n\n.rtk-article .rtk-lead {\n  font-size: 16px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n\n.rtk-article blockquote.rtk-voc {\n  position: relative;\n  border-left: 4px solid #00265d;\n  background: #f7f8f9;\n  padding: 18px 22px 18px 30px;\n  margin: 2em 0;\n  font-style: italic;\n  color: #333;\n}\n.rtk-article blockquote.rtk-voc p { margin-bottom: 0.4em; }\n.rtk-article blockquote.rtk-voc cite {\n  display: block;\n  font-style: normal;\n  font-size: 13px;\n  color: #4a4a4a;\n}\n\n.rtk-article .rtk-coa-list {\n  list-style: none;\n  padding: 0;\n}\n.rtk-article .rtk-coa-list li {\n  background: #fafbfc;\n  border: 1px solid #e1e8ec;\n  border-radius: 6px;\n  padding: 14px 18px;\n  margin-bottom: 12px;\n}\n\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 2.8em; }\n  .rtk-article h3 { margin-top: 1.8em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout,\n  .rtk-article blockquote.rtk-voc {\n    padding: 14px 16px;\n  }\n}\n.rtk-article.rtk-article .rtk-subtitle {\n  margin-top: -0.6em;\n  margin-bottom: 2em;\n  color: #5a6b78;\n  font-size: 15px;\n}\n\n.rtk-article.rtk-article .rtk-qa-block {\n  margin: 0 0 1.4em;\n}\n\n\/* Ramkumar\uff08\u9032\u884c\u5f79\uff09\u306e\u8cea\u554f\u30fb\u30b3\u30e1\u30f3\u30c8\uff1a\u67d4\u3089\u304b\u3044\u8584\u6c34\u8272\u306e\u30dc\u30c3\u30af\u30b9 *\/\n.rtk-article.rtk-article .rtk-qa-q {\n  background: #f5f9fc;\n  border-radius: 10px;\n  padding: 14px 20px 12px;\n  margin: 1.8em 0 1em;\n}\n.rtk-article.rtk-article .rtk-qa-q p {\n  margin: 4px 0 0;\n  font-style: italic;\n  color: #33475b;\n}\n\n\/* \u30b2\u30b9\u30c8\uff08Alexander \/ Laura\uff09\u306e\u56de\u7b54\uff1a\u5de6\u30ab\u30e9\u30fc\u30e9\u30a4\u30f3\u3067\u30b9\u30d4\u30fc\u30ab\u30fc\u3092\u533a\u5225 *\/\n.rtk-article.rtk-article .rtk-qa-a {\n  border-left: 4px solid #0d7bc4;\n  border-radius: 0 8px 8px 0;\n  padding: 2px 20px;\n  margin: 0 0 1.2em;\n}\n.rtk-article.rtk-article .rtk-qa-a-laura {\n  border-left-color: #1a8f7b;\n}\n.rtk-article.rtk-article .rtk-qa-a p {\n  margin: 4px 0 0.6em;\n}\n\n\/* \u30b9\u30d4\u30fc\u30ab\u30fc\u30e9\u30d9\u30eb\uff08\u30a2\u30d0\u30bf\u30fc\uff0b\u540d\u524d\uff09 *\/\n.rtk-article.rtk-article .rtk-qa-q-label,\n.rtk-article.rtk-article .rtk-qa-a-label {\n  display: inline-flex;\n  align-items: center;\n  gap: 8px;\n  font-weight: 700;\n  font-size: 14px;\n  color: #22314f;\n}\n.rtk-article.rtk-article .rtk-qa-avatar {\n  display: inline-flex;\n  align-items: center;\n  justify-content: center;\n  width: 26px;\n  height: 26px;\n  border-radius: 50%;\n  color: #fff;\n  font-size: 11px;\n  font-weight: 700;\n  flex: none;\n}\n.rtk-article.rtk-article .rtk-avatar-host { background: #6b7a90; }\n.rtk-article.rtk-article .rtk-avatar-alexander { background: #0d7bc4; }\n.rtk-article.rtk-article .rtk-avatar-laura { background: #1a8f7b; }\n\n\/* \u8a18\u4e8b\u672b\u5c3e\u306eCTA\u30ea\u30f3\u30af *\/\n.rtk-article.rtk-article .rtk-cta-list {\n  list-style: none;\n  padding: 0;\n  margin: 0;\n}\n.rtk-article.rtk-article .rtk-cta-list li {\n  margin-bottom: 10px;\n}\n.rtk-article.rtk-article .rtk-cta-list a {\n  font-weight: 700;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article.rtk-article .rtk-qa-q,\n  .rtk-article.rtk-article .rtk-qa-a {\n    padding-left: 14px;\n    padding-right: 14px;\n  }\n}\n<\/style>\n\n<div class=\"rtk-article\">\n\n\n<div class=\"rtk-intro\">\n<p class=\"rtk-lead\">\u98df\u54c1\u691c\u67fb\u30e9\u30dc\u306f\u3001\u3042\u3089\u3086\u308b\u65b9\u5411\u304b\u3089\u306e\u30d7\u30ec\u30c3\u30b7\u30e3\u30fc\u306b\u3055\u3089\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u898f\u5236\u5f53\u5c40\u306f\u6700\u5927\u6b8b\u7559\u57fa\u6e96\u5024\uff08MRL\uff09\u3092\u53b3\u683c\u5316\u3057\u3066\u304a\u308a\u3001\u5869\u7d20\u7cfb\u6eb6\u5a92\u306e\u4f7f\u7528\u7981\u6b62\u306b\u3088\u3063\u3066\u524d\u51e6\u7406\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3082\u898b\u76f4\u3057\u3092\u8feb\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u8fb2\u85ac\u5206\u6790\u5bfe\u8c61\u30ea\u30b9\u30c8\u306f700\u6210\u5206\u3092\u8d85\u3048\u308b\u898f\u6a21\u306b\u62e1\u5927\u3057\u307e\u3057\u305f\u3002\u305d\u306e\u4e00\u65b9\u3067\u3001\u7d0d\u671f\u306f\u65e5\u5358\u4f4d\u3067\u306f\u306a\u304f\u6642\u9593\u5358\u4f4d\u3067\u6c42\u3081\u3089\u308c\u308b\u3088\u3046\u306b\u306a\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<\/div>\n\n<p>\u3082\u306f\u3084\u554f\u984c\u306f\u3001GC-MS\/MS\u3067\u5fae\u91cf\u306e\u8fb2\u85ac\u3092\u691c\u51fa\u3067\u304d\u308b\u304b\u3069\u3046\u304b\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u6700\u65b0\u306e\u30c8\u30ea\u30d7\u30eb\u56db\u91cd\u6975\u578b\u88c5\u7f6e\u306b\u3088\u308a\u3001\u3053\u306e\u8ab2\u984c\u306f\u3059\u3067\u306b\u89e3\u6c7a\u6e08\u307f\u3068\u3044\u3048\u307e\u3059\u3002\u771f\u306e\u8ab2\u984c\u306f\u3001GC\u30ab\u30e9\u30e0\u3068\u6ce8\u5165\u53e3\u90e8\u6750\u304c\u3001\u6975\u3081\u3066\u593e\u96d1\u7269\u306e\u591a\u3044\u98df\u54c1\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3092\u5bfe\u8c61\u3068\u3057\u305f\u6570\u5343\u56de\u306e\u6ce8\u5165\u306b\u8010\u3048\u3089\u308c\u308b\u304b\u3069\u3046\u304b\u306b\u3042\u308a\u307e\u3059\u3002<\/p>\n\n<p>\u4eca\u56de\u306e\u5bfe\u8ac7\u3067\u306f\u3001Restek \u306e Ramkumar Dhandapani\uff08\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u91ce\u306723\u5e74\u4ee5\u4e0a\u306e\u7d4c\u9a13\u3092\u6301\u3064\u5206\u6790\u5316\u5b66\u535a\u58eb\u3001\u30d7\u30ed\u30c0\u30af\u30c8\u30de\u30cd\u30b8\u30e1\u30f3\u30c8\u90e8\u9580\u30c7\u30a3\u30ec\u30af\u30bf\u30fc\uff09\u304c\u3001\u30c9\u30a4\u30c4\u306e Eurofins \u793e\u30e9\u30dc\u306b\u6240\u5c5e\u3059\u308b Dr. Alexander Zahm \u6c0f\u304a\u3088\u3073 Laura Sch\u00fctz \u6c0f\u3068\u3068\u3082\u306b\u3001\u98df\u54c1\u5b89\u5168\u6027\u8a66\u9a13\u3092\u53d6\u308a\u5dfb\u304f\u5909\u5316\u3068\u73fe\u5728\u306e\u8ab2\u984c\u306b\u3064\u3044\u3066\u8a9e\u308a\u5408\u3044\u307e\u3057\u305f\u3002<\/p>\n\n<div style=\"margin-top: 5em;\"><\/div>\n\n<h2>\u30b2\u30b9\u30c8\u30a8\u30ad\u30b9\u30d1\u30fc\u30c8\u7d39\u4ecb\uff5cEurofins Dr. Specht Express Testing &amp; Inspection GmbH<\/h2><\/div>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-image102489_96113a-82 .kb-image-has-overlay:after{opacity:0.3;border-top-left-radius:20px;border-top-right-radius:20px;border-bottom-right-radius:20px;border-bottom-left-radius:20px;}.kb-image102489_96113a-82 img.kb-img, .kb-image102489_96113a-82 .kb-img img{border-top-left-radius:20px;border-top-right-radius:20px;border-bottom-right-radius:20px;border-bottom-left-radius:20px;}<\/style>\n<div class=\"wp-block-kadence-image kb-image102489_96113a-82\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"738\" height=\"353\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-hot-topics-in-pesticides-analysis-02.png\" alt=\"headshots of interviewees\" class=\"kb-img wp-image-96303\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-hot-topics-in-pesticides-analysis-02.png 738w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-hot-topics-in-pesticides-analysis-02-300x143.png 300w\" sizes=\"auto, (max-width: 738px) 100vw, 738px\" \/><\/figure><\/div>\n\n\n\n<style data-wp-block-html=\"css\">\n<style>\n\/* ===== \u30d9\u30fc\u30b9\uff1artk-article-style.css\uff08\u5171\u901a\uff09 ===== *\/\n.rtk-article { line-height: 1.8; font-size: 17px; }\n\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n\n.rtk-article h2 {\n  margin-top: 4em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n\n.rtk-article h3 {\n  margin-top: 2.4em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n\n.rtk-article p {\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n\n.rtk-article .rtk-lead {\n  font-size: 16px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n\n.rtk-article blockquote.rtk-voc {\n  position: relative;\n  border-left: 4px solid #00265d;\n  background: #f7f8f9;\n  padding: 18px 22px 18px 30px;\n  margin: 2em 0;\n  font-style: italic;\n  color: #333;\n}\n.rtk-article blockquote.rtk-voc p { margin-bottom: 0.4em; }\n.rtk-article blockquote.rtk-voc cite {\n  display: block;\n  font-style: normal;\n  font-size: 13px;\n  color: #4a4a4a;\n}\n\n.rtk-article .rtk-coa-list {\n  list-style: none;\n  padding: 0;\n}\n.rtk-article .rtk-coa-list li {\n  background: #fafbfc;\n  border: 1px solid #e1e8ec;\n  border-radius: 6px;\n  padding: 14px 18px;\n  margin-bottom: 12px;\n}\n\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 2.8em; }\n  .rtk-article h3 { margin-top: 1.8em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout,\n  .rtk-article blockquote.rtk-voc {\n    padding: 14px 16px;\n  }\n}\n\n\/* ===== \u3053\u306e\u8a18\u4e8b\u5c02\u7528\u306e\u8ffd\u52a0\u30b9\u30bf\u30a4\u30eb\uff08\u5bfe\u8ac7\u5f62\u5f0f\u306eQ&A\u8868\u793a\uff09 =====\n   \u30b9\u30b3\u30fc\u30d7\u306f .rtk-article.rtk-article \u3067\u4e8c\u91cd\u30af\u30e9\u30b9\u5316\u3057\u3001\n   \u5171\u901a\u30b9\u30bf\u30a4\u30eb\u30b7\u30fc\u30c8\uff08rtk-article-style.css\uff09\u306b\u306f\u5f71\u97ff\u3057\u306a\u3044\u5f62\u306b\u3057\u3066\u3044\u307e\u3059\u3002 *\/\n\n.rtk-article.rtk-article .rtk-subtitle {\n  margin-top: -0.6em;\n  margin-bottom: 2em;\n  color: #5a6b78;\n  font-size: 15px;\n}\n\n.rtk-article.rtk-article .rtk-qa-block {\n  margin: 0 0 1.4em;\n}\n\n\/* Ramkumar\uff08\u9032\u884c\u5f79\uff09\u306e\u8cea\u554f\u30fb\u30b3\u30e1\u30f3\u30c8\uff1a\u67d4\u3089\u304b\u3044\u8584\u6c34\u8272\u306e\u30dc\u30c3\u30af\u30b9 *\/\n.rtk-article.rtk-article .rtk-qa-q {\n  background: #f5f9fc;\n  border-radius: 10px;\n  padding: 14px 20px 12px;\n  margin: 1.8em 0 1em;\n}\n.rtk-article.rtk-article .rtk-qa-q p {\n  margin: 4px 0 0;\n  font-style: italic;\n  color: #33475b;\n}\n\n\/* \u30b2\u30b9\u30c8\uff08Alexander \/ Laura\uff09\u306e\u56de\u7b54\uff1a\u5de6\u30ab\u30e9\u30fc\u30e9\u30a4\u30f3\u3067\u30b9\u30d4\u30fc\u30ab\u30fc\u3092\u533a\u5225 *\/\n.rtk-article.rtk-article .rtk-qa-a {\n  border-left: 4px solid #0d7bc4;\n  border-radius: 0 8px 8px 0;\n  padding: 2px 20px;\n  margin: 0 0 1.2em;\n}\n.rtk-article.rtk-article .rtk-qa-a-laura {\n  border-left-color: #1a8f7b;\n}\n.rtk-article.rtk-article .rtk-qa-a p {\n  margin: 4px 0 0.6em;\n}\n\n\/* \u30b9\u30d4\u30fc\u30ab\u30fc\u30e9\u30d9\u30eb\uff08\u30a2\u30d0\u30bf\u30fc\uff0b\u540d\u524d\uff09 *\/\n.rtk-article.rtk-article .rtk-qa-q-label,\n.rtk-article.rtk-article .rtk-qa-a-label {\n  display: inline-flex;\n  align-items: center;\n  gap: 8px;\n  font-weight: 700;\n  font-size: 14px;\n  color: #22314f;\n}\n.rtk-article.rtk-article .rtk-qa-avatar {\n  display: inline-flex;\n  align-items: center;\n  justify-content: center;\n  width: 26px;\n  height: 26px;\n  border-radius: 50%;\n  color: #fff;\n  font-size: 11px;\n  font-weight: 700;\n  flex: none;\n}\n.rtk-article.rtk-article .rtk-avatar-host { background: #6b7a90; }\n.rtk-article.rtk-article .rtk-avatar-alexander { background: #0d7bc4; }\n.rtk-article.rtk-article .rtk-avatar-laura { background: #1a8f7b; }\n\n\/* \u8a18\u4e8b\u672b\u5c3e\u306eCTA\u30ea\u30f3\u30af *\/\n.rtk-article.rtk-article .rtk-cta-list {\n  list-style: none;\n  padding: 0;\n  margin: 0;\n}\n.rtk-article.rtk-article .rtk-cta-list li {\n  margin-bottom: 10px;\n}\n.rtk-article.rtk-article .rtk-cta-list a {\n  font-weight: 700;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article.rtk-article .rtk-qa-q,\n  .rtk-article.rtk-article .rtk-qa-a {\n    padding-left: 14px;\n    padding-right: 14px;\n  }\n}\n<\/style>\n\n<div class=\"rtk-article\">\n<h2>\u30e9\u30dc\u904b\u55b6\u3068\u30d9\u30f3\u30c1\u30ef\u30fc\u30af\u3001\u4e8c\u3064\u306e\u8996\u70b9<\/h2>\n\n<div class=\"rtk-qa-block\">\n  <div class=\"rtk-qa-q\">\n    <span class=\"rtk-qa-q-label\"><span class=\"rtk-qa-avatar rtk-avatar-host\">RD<\/span>Ramkumar<\/span>\n    <p>\u672c\u65e5\u306f\u3001\u6b8b\u7559\u8fb2\u85ac\u5206\u6790\u306b\u95a2\u3059\u308b\u77e5\u898b\u3092\u5171\u6709\u3057\u3066\u3044\u305f\u3060\u304d\u3001\u3042\u308a\u304c\u3068\u3046\u3054\u3056\u3044\u307e\u3059\u3002\u307e\u305a\u3001\u5fa1\u793e\u306e\u30e9\u30dc\u3068\u696d\u52d9\u5185\u5bb9\u306b\u3064\u3044\u3066\u6559\u3048\u3066\u3044\u305f\u3060\u3051\u307e\u3059\u304b\u3002<\/p>\n  <\/div>\n  <div class=\"rtk-qa-a rtk-qa-a-alexander\">\n    <span class=\"rtk-qa-a-label\"><span class=\"rtk-qa-avatar rtk-avatar-alexander\">AZ<\/span>Alexander<\/span>\n    <p>\u3082\u3061\u308d\u3093\u3067\u3059\u3002\u79c1\u306f\u30c9\u30a4\u30c4\u306e Eurofins Dr. Specht \u3067 Managing Director \u3092\u52d9\u3081\u3066\u3044\u307e\u3059\u3002\u5f53\u793e\u306f\u3001\u8907\u6570\u6b8b\u7559\u8fb2\u85ac\u306e\u4e00\u6589\u5206\u6790\u3092\u5c02\u9580\u3068\u3059\u308b\u3001\u9ad8\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u5bfe\u5fdc\u306e\u8a8d\u5b9a\u5951\u7d04\u8a66\u9a13\u6a5f\u95a2\u3067\u3059\u3002\u593e\u96d1\u7269\u306e\u591a\u3044\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u304b\u3089\u62bd\u51fa\u3057\u305f QuEChERS \u62bd\u51fa\u6db2\u3092\u3001\u6bce\u9031\u6570\u767e\u4ef6\u306e\u30da\u30fc\u30b9\u3067\u30bf\u30a4\u30c8\u306a\u7d0d\u671f\u306e\u306a\u304b\u5206\u6790\u3057\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u88c5\u7f6e\u306e\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u306f\u8a31\u3055\u308c\u307e\u305b\u3093\u3002<\/p>\n    <p>\u79c1\u306f\u3001\u6761\u4ef6\u3092\u6574\u3048\u305f\u30c7\u30e2\u30f3\u30b9\u30c8\u30ec\u30fc\u30b7\u30e7\u30f3\u3060\u3051\u3067\u306a\u304f\u3001\u5b9f\u969b\u306e\u73fe\u5834\u3067\u6a5f\u80fd\u3059\u308b\u6280\u8853\u3092\u6c42\u3081\u3066\u3044\u307e\u3059\u3002\u65b0\u3057\u3044 GC \u30ab\u30e9\u30e0\u3092\u8a55\u4fa1\u3059\u308b\u969b\u3001\u5e38\u306b\u554f\u308f\u308c\u308b\u306e\u306f\u300c\u5b9f\u969b\u306e\u5206\u6790\u6761\u4ef6\u4e0b\u3067\u6027\u80fd\u3092\u7dad\u6301\u3067\u304d\u308b\u304b\u300d\u3068\u3044\u3046\u70b9\u3067\u3059\u3002<\/p>\n  <\/div>\n  <div class=\"rtk-qa-a rtk-qa-a-laura\">\n    <span class=\"rtk-qa-a-label\"><span class=\"rtk-qa-avatar rtk-avatar-laura\">LS<\/span>Laura<\/span>\n    <p>Dr. Zahm \u304c\u30e9\u30dc\u904b\u55b6\u306e\u8996\u70b9\u3092\u62c5\u3046\u4e00\u65b9\u3067\u3001\u79c1\u306f\u30d9\u30f3\u30c1\u30ef\u30fc\u30af\u3092\u62c5\u5f53\u3057\u3066\u3044\u307e\u3059\u3002\u5177\u4f53\u7684\u306b\u306f\u3001\u5b9f\u9a13\u306e\u8a2d\u8a08\u3068\u5b9f\u65bd\u3001\u30c7\u30fc\u30bf\u89e3\u6790\u3001\u305d\u3057\u3066\u305d\u308c\u3089\u304c\u65e5\u5e38\u306e\u6b8b\u7559\u8fb2\u85ac\u5206\u6790\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306b\u3069\u306e\u3088\u3046\u306a\u610f\u5473\u3092\u6301\u3064\u306e\u304b\u3092\u691c\u8a0e\u3059\u308b\u5f79\u5272\u3067\u3059\u3002\u79c1\u306e\u4ed5\u4e8b\u306f\u3001GC \u30ab\u30e9\u30e0\u6280\u8853\u304c\u7ba1\u7406\u3055\u308c\u305f\u6761\u4ef6\u4e0b\u3067\u793a\u3059\u6027\u80fd\u3068\u3001\u5b9f\u969b\u306e\u30e9\u30dc\u306e\u53b3\u3057\u3044\u6761\u4ef6\u4e0b\u3067\u767a\u63ee\u3055\u308c\u308b\u6027\u80fd\u3068\u306e\u30ae\u30e3\u30c3\u30d7\u3092\u57cb\u3081\u308b\u3053\u3068\u306b\u3042\u308a\u307e\u3059\u3002<\/p>\n  <\/div>\n<\/div>\n\n<h2>\u696d\u754c\u304c\u62b1\u3048\u308b\u8ab2\u984c<\/h2>\n\n<div class=\"rtk-qa-block\">\n  <div class=\"rtk-qa-q\">\n    <span class=\"rtk-qa-q-label\"><span class=\"rtk-qa-avatar rtk-avatar-host\">RD<\/span>Ramkumar<\/span>\n    <p>\u304a\u4e8c\u4eba\u306f\u98df\u54c1\u5b89\u5168\u6027\u8a66\u9a13\u306e\u6700\u524d\u7dda\u306b\u3044\u3089\u3063\u3057\u3083\u3044\u307e\u3059\u3002\u73fe\u5728\u3001\u6b8b\u7559\u8fb2\u85ac\u5206\u6790\u306b\u304a\u3044\u3066\u6700\u3082\u5927\u304d\u306a\u5206\u6790\u4e0a\u306e\u8ab2\u984c\u306f\u4f55\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n  <\/div>\n  <div class=\"rtk-qa-a rtk-qa-a-alexander\">\n    <span class=\"rtk-qa-a-label\"><span class=\"rtk-qa-avatar rtk-avatar-alexander\">AZ<\/span>Alexander<\/span>\n    <p>\u6700\u3082\u6839\u672c\u7684\u306a\u8ab2\u984c\u306f\u3001\u691c\u51fa\u5bfe\u8c61\u306e\u7bc4\u56f2\u304c\u5e83\u3044\u3053\u3068\u3067\u3059\u3002\u73fe\u5728\u306e\u7d71\u5408\u6b8b\u7559\u8fb2\u85ac\u5206\u6790\u6cd5\u306f\u3001\u6975\u6027\u5316\u5408\u7269\u3001\u7121\u6975\u6027\u5316\u5408\u7269\u3001\u9178\u6027\u5316\u5408\u7269\u3001\u5869\u57fa\u6027\u5316\u5408\u7269\u3001\u4e2d\u6027\u5316\u5408\u7269\u3092\u542b\u3080700\u6210\u5206\u4ee5\u4e0a\u3092\u5bfe\u8c61\u3068\u3057\u3001\u3053\u308c\u3089\u3059\u3079\u3066\u30921\u56de\u306e\u5206\u6790\u3067\u6e2c\u5b9a\u3057\u307e\u3059\u3002GC\u5206\u6790\u306b\u9650\u3063\u3066\u3082\u3001\u5f53\u30e9\u30dc\u3067\u306f1\u30b7\u30fc\u30b1\u30f3\u30b9\u3042\u305f\u308a300\u6210\u5206\u3092\u8d85\u3048\u308b\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u6271\u3063\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u5316\u5408\u7269\u306e\u591a\u69d8\u6027\u306f\u3001\u5358\u4e00\u306eGC\u30ab\u30e9\u30e0\u306e\u5316\u5b66\u7684\u6027\u8cea\u3060\u3051\u3067\u306f\u5bfe\u5fdc\u3057\u304d\u308c\u306a\u3044\u307b\u3069\u904e\u9177\u3067\u3059\u3002<\/p>\n    <p>\u52a0\u3048\u3066\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u7531\u6765\u306e\u6c5a\u67d3\u3082\u5927\u304d\u306a\u61f8\u5ff5\u4e8b\u9805\u3067\u3059\u3002\u6c5a\u67d3\u306b\u3088\u3063\u3066\u6027\u80fd\u57fa\u6e96\u3092\u6e80\u305f\u305b\u306a\u304f\u306a\u308b\u3068\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u305f\u3081\u306e\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u304c\u767a\u751f\u3057\u3001\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u304c\u5b8c\u5168\u306b\u505c\u6b62\u3057\u3066\u3057\u307e\u3044\u307e\u3059\u3002\u6700\u65b0\u306eGC-MS\/MS\u88c5\u7f6e\u3067\u306f\u3001\u691c\u51fa\u611f\u5ea6\u306f\u3082\u306f\u3084\u4e3b\u8981\u306a\u61f8\u5ff5\u4e8b\u9805\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u65e5\u5e38\u306e\u6b8b\u7559\u8fb2\u85ac\u5206\u6790\u3067\u4eca\u3001\u672c\u5f53\u306e\u30dc\u30c8\u30eb\u30cd\u30c3\u30af\u3068\u306a\u3063\u3066\u3044\u308b\u306e\u306f\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u8010\u6027\u3067\u3059\u3002<\/p>\n  <\/div>\n  <div class=\"rtk-qa-a rtk-qa-a-laura\">\n    <span class=\"rtk-qa-a-label\"><span class=\"rtk-qa-avatar rtk-avatar-laura\">LS<\/span>Laura<\/span>\n    <p>\u904b\u7528\u9762\u306e\u8ab2\u984c\u3082\u4ed8\u3051\u52a0\u3048\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002\u5834\u5408\u306b\u3088\u3063\u3066\u306f\u3001\u6570\u6642\u9593\u4ee5\u5185\u3067\u306e\u7d50\u679c\u5831\u544a\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002\u88c5\u7f6e\u306e\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u306f\u6c7a\u3057\u3066\u8a31\u5bb9\u3055\u308c\u307e\u305b\u3093\u3002\u305d\u306e\u305f\u3081\u3001\u30ab\u30e9\u30e0\u304c\u60f3\u5b9a\u3088\u308a\u65e9\u304f\u52a3\u5316\u3057\u305f\u308a\u300180\u56de\u306e\u6ce8\u5165\u5f8c\u306b\u56de\u53ce\u7387\u304c\u8a31\u5bb9\u57fa\u6e96\u304b\u3089\u5916\u308c\u305f\u308a\u3059\u308b\u3068\u3001\u5358\u306a\u308b\u79d1\u5b66\u7684\u306a\u554f\u984c\u3067\u306f\u6e08\u307e\u306a\u304f\u306a\u308a\u307e\u3059\u3002\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb\u4e0a\u306e\u5371\u6a5f\u306b\u3064\u306a\u304c\u308b\u306e\u3067\u3059\u3002\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u60aa\u5316\u3084\u56de\u53ce\u7387\u306e\u4f4e\u4e0b\u306b\u3088\u308b\u518d\u5206\u6790\u306f\u3001\u305d\u306e\u305f\u3073\u306b\u8cb4\u91cd\u306a\u6642\u9593\u3092\u596a\u3044\u307e\u3059\u3002<\/p>\n  <\/div>\n<\/div>\n\n<div class=\"rtk-qa-block\">\n  <div class=\"rtk-qa-q\">\n    <span class=\"rtk-qa-q-label\"><span class=\"rtk-qa-avatar rtk-avatar-host\">RD<\/span>Ramkumar<\/span>\n    <p>\u5927\u5909\u8208\u5473\u6df1\u3044\u3067\u3059\u306d\u3002\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u8010\u6027\u304c\u306a\u305c\u3053\u308c\u307b\u3069\u5927\u304d\u306a\u554f\u984c\u3068\u306a\u308b\u306e\u304b\u3001\u8a73\u3057\u304f\u4f3a\u3048\u307e\u3059\u304b\u3002\u6700\u65b0\u306eGC-MS\/MS\u88c5\u7f6e\u306f\u6975\u3081\u3066\u9ad8\u3044\u691c\u51fa\u611f\u5ea6\u3092\u5099\u3048\u3066\u3044\u307e\u3059\u304c\u3001\u3069\u3053\u306b\u554f\u984c\u304c\u751f\u3058\u308b\u306e\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n  <\/div>\n  <div class=\"rtk-qa-a rtk-qa-a-alexander\">\n    <span class=\"rtk-qa-a-label\"><span class=\"rtk-qa-avatar rtk-avatar-alexander\">AZ<\/span>Alexander<\/span>\n    <p>10\u301c15\u5e74\u524d\u306e\u30b7\u30f3\u30b0\u30eb\u56db\u91cd\u6975\u578b\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u300110 ppb\u306eLOQ\u306b\u5230\u9054\u3059\u308b\u3053\u3068\u81ea\u4f53\u304c\u5927\u304d\u306a\u8ab2\u984c\u3067\u3057\u305f\u3002\u3057\u304b\u3057\u73fe\u5728\u306eGC\u30c8\u30ea\u30d7\u30eb\u56db\u91cd\u6975\u578b\u88c5\u7f6e\u3067\u306f\u3001\u691c\u51fa\u611f\u5ea6\u306e\u554f\u984c\u306f\u3059\u3067\u306b\u89e3\u6c7a\u3057\u3066\u3044\u307e\u3059\u3002\u73fe\u5728\u306e\u554f\u984c\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u30d0\u30a4\u30a2\u30eb\u304b\u3089\u30a4\u30aa\u30f3\u6e90\u306b\u81f3\u308b\u307e\u3067\u306e\u7d4c\u8def\u3067\u4f55\u304c\u8d77\u3053\u308b\u304b\u306b\u3042\u308a\u307e\u3059\u3002\u6ce8\u5165\u306e\u305f\u3073\u306b\u3001\u8102\u80aa\u9178\u3001\u8272\u7d20\u3001\u30ea\u30f3\u8102\u8cea\u3001\u7cd6\u985e\u306a\u3069\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u304c\u3001\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u3001\u30ab\u30e9\u30e0\u30d8\u30c3\u30c9\u3001\u305d\u3057\u3066\u6700\u7d42\u7684\u306b\u306f\u30a4\u30aa\u30f3\u6e90\u306b\u307e\u3067\u84c4\u7a4d\u3057\u3066\u3044\u304d\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u304c\u84c4\u7a4d\u3059\u308b\u3053\u3068\u3067\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u304c\u63a5\u89e6\u3059\u308b\u3042\u3089\u3086\u308b\u90e8\u5206\u306e\u8868\u9762\u5316\u5b66\u7684\u6027\u8cea\u304c\u5909\u5316\u3057\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u56de\u53ce\u7387\u304c\u5909\u52d5\u3057\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u3082\u60aa\u5316\u3057\u307e\u3059\u30021\u56de\u76ee\u306f\u6709\u52b9\u3060\u3063\u305f\u691c\u91cf\u7dda\u3082\u3001100\u56de\u76ee\u306b\u306f\u3082\u3046\u4f7f\u3048\u307e\u305b\u3093\u3002\u5384\u4ecb\u306a\u306e\u306f\u3001\u3053\u306e\u52a3\u5316\u304c\u3086\u3063\u304f\u308a\u9032\u3080\u3053\u3068\u3002\u6e2c\u5b9a\u5024\u304c\u8a31\u5bb9\u7bc4\u56f2\u3092\u5916\u308c\u3001\u9ad8\u30b3\u30b9\u30c8\u306a\u518d\u5206\u6790\u3092\u8feb\u3089\u308c\u3066\u521d\u3081\u3066\u3001\u7570\u5909\u306b\u6c17\u3065\u304f\u3053\u3068\u3082\u5c11\u306a\u304f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n  <\/div>\n  <div class=\"rtk-qa-a rtk-qa-a-laura\">\n    <span class=\"rtk-qa-a-label\"><span class=\"rtk-qa-avatar rtk-avatar-laura\">LS<\/span>Laura<\/span>\n    <p>\u3060\u304b\u3089\u3053\u305d\u3001\u79c1\u305f\u3061\u306fRMX-5Sil MS\u30ab\u30e9\u30e0\u3092\u81ea\u3089\u8a55\u4fa1\u3057\u305f\u3044\u3068\u8003\u3048\u307e\u3057\u305f\u3002TriMax\u4e0d\u6d3b\u6027\u5316\u6280\u8853\u3092\u63a1\u7528\u3057\u305f\u65b0\u3057\u3044RMX\u30ab\u30e9\u30e0\u3067\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u8010\u6027\u304c\u3069\u308c\u3060\u3051\u9ad8\u307e\u308b\u306e\u304b\u3092\u78ba\u304b\u3081\u305f\u304b\u3063\u305f\u306e\u3067\u3059\u3002<\/p>\n    <p>\u79c1\u305f\u3061\u306e\u5b9f\u9a13\u3067\u3001\u52a3\u5316\u304c\u6700\u3082\u9855\u8457\u306b\u73fe\u308c\u305f\u306e\u306f\u30c7\u30eb\u30bf\u30e1\u30c8\u30ea\u30f3\u3084\u30af\u30ed\u30eb\u30d4\u30ea\u30db\u30b9\u3068\u3044\u3063\u305f\u6d3b\u6027\u306e\u9ad8\u3044\u5316\u5408\u7269\u3067\u3057\u305f\u3002\u540c\u4e00\u30b7\u30fc\u30b1\u30f3\u30b9\u5185\u30676\u56de\u30e9\u30a4\u30ca\u30fc\u3092\u4ea4\u63db\u3057\u306a\u304c\u3089\u3001\u901a\u5e38\u4f7f\u7528\u3057\u3066\u3044\u308b\u30ab\u30e9\u30e0\u3067\u30c7\u30eb\u30bf\u30e1\u30c8\u30ea\u30f3\u306e\u56de\u53ce\u7387\u3092\u6bd4\u8f03\u3057\u305f\u3068\u3053\u308d\u3001\u5909\u52d5\u5e45\u306f30%\u3092\u8d85\u3048\u307e\u3057\u305f\u3002\u4e00\u65b9\u3001RMX\u30ab\u30e9\u30e0\u3067\u306f\u3001\u540c\u3058\u5316\u5408\u7269\u306b\u304a\u3051\u308b\u56de\u53ce\u7387\u306e\u5909\u52d5\u5e45\u304c\u306f\u308b\u304b\u306b\u72ed\u304f\u3001\u8a31\u5bb9\u7bc4\u56f2\u5185\u306b\u53ce\u307e\u308a\u307e\u3057\u305f\u3002\u30af\u30ed\u30eb\u30d4\u30ea\u30db\u30b9\u306b\u3064\u3044\u3066\u306f\u3001\u901a\u5e38\u306e\u30ab\u30e9\u30e0\u3067\u306f\u5c11\u306a\u304f\u3068\u30822\u4ef6\u306e\u7d50\u679c\u304cQC\u57fa\u6e96\u306b\u3088\u308a\u518d\u5206\u6790\u3092\u8981\u3059\u308b\u6c34\u6e96\u3067\u3057\u305f\u304c\u3001RMX\u30ab\u30e9\u30e0\u3067\u306f\u3059\u3079\u3066\u306e\u5024\u304c\u898f\u683c\u5185\u306b\u53ce\u307e\u308a\u307e\u3057\u305f\u3002\u518d\u5206\u6790\u30921\u4ef6\u3067\u3082\u56de\u907f\u3067\u304d\u308b\u3053\u3068\u306b\u306f\u3001\u5927\u304d\u306a\u6642\u9593\u3068\u30b3\u30b9\u30c8\u306e\u7bc0\u7d04\u3068\u3044\u3046\u610f\u5473\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n  <\/div>\n<\/div>\n\n<h2>\u5b9f\u969b\u306e\u5206\u6790\u7d50\u679c<\/h2>\n\n<div class=\"rtk-qa-block\">\n  <div class=\"rtk-qa-q\">\n    <span class=\"rtk-qa-q-label\"><span class=\"rtk-qa-avatar rtk-avatar-host\">RD<\/span>Ramkumar<\/span>\n    <p>\u5b9f\u9a13\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u3001\u3082\u3046\u5c11\u3057\u4f3a\u3048\u307e\u3059\u304b\u3002RMX\u306eGC\u30ab\u30e9\u30e0\u6280\u8853\u304c\u3001\u5b9f\u969b\u306e\u5206\u6790\u6761\u4ef6\u4e0b\u3067\u3069\u306e\u3088\u3046\u306a\u6027\u80fd\u3092\u793a\u3057\u305f\u306e\u304b\u8208\u5473\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n  <\/div>\n  <div class=\"rtk-qa-a rtk-qa-a-alexander\">\n    <span class=\"rtk-qa-a-label\"><span class=\"rtk-qa-avatar rtk-avatar-alexander\">AZ<\/span>Alexander<\/span>\n    <p>\u3082\u3061\u308d\u3093\u3067\u3059\u3002RMX-5Sil MS\u30ab\u30e9\u30e0\u3068\u901a\u5e38\u4f7f\u7528\u3057\u3066\u3044\u308b\u30ab\u30e9\u30e0\u3092\u3001\u540c\u4e00\u6761\u4ef6\u4e0b\u3067\u76f4\u63a5\u6bd4\u8f03\u3057\u307e\u3057\u305f\u3002GC-MS\/MS\u306e\u30c8\u30fc\u30bf\u30eb\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306b\u306f\u3001\u305d\u306e\u9055\u3044\u304c\u306f\u3063\u304d\u308a\u3068\u8868\u308c\u307e\u3057\u305f\u3002RMX\u30ab\u30e9\u30e0\u3067\u306f\u3001\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u304c\u3088\u308a\u5b89\u5b9a\u3057\u3066\u304a\u308a\u3001\u5206\u6790\u304c\u96e3\u3057\u3044\u9ad8\u6cb8\u70b9\u8fb2\u85ac\u304c\u6eb6\u51fa\u3059\u308b\u5f8c\u671f\u4fdd\u6301\u6642\u9593\u306b\u304a\u3044\u3066\u3082\u3001\u30ab\u30e9\u30e0\u30d6\u30ea\u30fc\u30c9\u304c\u5927\u5e45\u306b\u4f4e\u3044\u3053\u3068\u304c\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n    <p>\u3055\u3089\u306b\u3001\u30b9\u30df\u30b9\u30ea\u30f3\u306e\u3088\u3046\u306b\u03c0\u7d50\u5408\u3092\u542b\u307f\u3001\u6d3b\u6027\u30b5\u30a4\u30c8\u3068\u76f8\u4e92\u4f5c\u7528\u3057\u3084\u3059\u3044\u5316\u5408\u7269\u306e\u5834\u5408\u3001\u901a\u5e38\u306e\u30ab\u30e9\u30e0\u3067\u306f\u30d4\u30fc\u30af\u304c\u30d6\u30ed\u30fc\u30c9\u3067\u30c6\u30fc\u30ea\u30f3\u30b0\u3092\u8d77\u3053\u3057\u307e\u3057\u305f\u3002\u4e00\u65b9\u3001RMX\u30ab\u30e9\u30e0\u3067\u306f\u3001\u30e9\u30a4\u30ca\u30fc\u3092\u8907\u6570\u56de\u4ea4\u63db\u3057\u305f\u5f8c\u3067\u3082\u3001\u540c\u3058\u5316\u5408\u7269\u3067\u30d4\u30fc\u30af\u304c\u72ed\u304f\u30b7\u30e3\u30fc\u30d7\u3067\u5bfe\u79f0\u7684\u306a\u5f62\u72b6\u3092\u7dad\u6301\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u4e00\u8cab\u6027\u3053\u305d\u304c\u3001\u898f\u5236\u74b0\u5883\u4e0b\u3067\u306e\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u5b9a\u91cf\u3092\u53ef\u80fd\u306b\u3057\u307e\u3059\u3002<\/p>\n  <\/div>\n  <div class=\"rtk-qa-a rtk-qa-a-laura\">\n    <span class=\"rtk-qa-a-label\"><span class=\"rtk-qa-avatar rtk-avatar-laura\">LS<\/span>Laura<\/span>\n    <p>\u5b9f\u9a13\u5185\u5bb9\u3092\u88dc\u8db3\u3057\u307e\u3059\u3068\u3001\u5404\u30ab\u30e9\u30e0\u306b\u3064\u3044\u3066\u4e00\u9023\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u30b5\u30f3\u30d7\u30eb\u3068QC\u30c1\u30a7\u30c3\u30af\u3092\u5b9f\u65bd\u3057\u305f\u306e\u3061\u3001\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u3092\u4ea4\u63db\u3057\u3066\u30b7\u30fc\u30b1\u30f3\u30b9\u3092\u7d99\u7d9a\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u30926\u56de\u7e70\u308a\u8fd4\u3057\u3066\u3044\u307e\u3059\u3002\u30ab\u30e9\u30e0\u6027\u80fd\u306e\u5909\u5316\u3092\u691c\u51fa\u3059\u308b\u305f\u3081\u3001\u5404\u30e9\u30a4\u30ca\u30fc\u4ea4\u63db\u5f8c\u306e\u7d50\u679c\u3092\u6700\u521d\u306e\u30e9\u30a4\u30ca\u30fc\u3067\u306e\u7d50\u679c\u3068\u6bd4\u8f03\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u8a66\u9a13\u8a2d\u8a08\u306b\u3088\u308a\u3001\u65b0\u3057\u3044\u6280\u8853\u3092\u63a1\u7528\u3057\u305fRMX GC\u30ab\u30e9\u30e0\u304c\u3069\u308c\u3060\u3051\u9811\u5065\u304b\u3092\u8a55\u4fa1\u3057\u3001\u901a\u5e38\u306e\u30ab\u30e9\u30e0\u3068\u6bd4\u8f03\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3057\u305f\u3002<\/p>\n    <p>\u4eca\u56de\u306e\u691c\u8a0e\u5bfe\u8c61\u306f350\u7a2e\u985e\u3092\u8d85\u3048\u308b\u8fb2\u85ac\u3067\u3001\u5206\u6790\u304c\u96e3\u3057\u3044\u3053\u3068\u3067\u77e5\u3089\u308c\u308b\u5316\u5408\u7269\u3082\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u5b9f\u969b\u306e\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u3092\u60f3\u5b9a\u3057\u3001\u30b3\u30e1\u306e\u3088\u3046\u306a\u593e\u96d1\u7269\u306e\u591a\u3044\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3092\u3042\u3048\u3066\u9078\u629e\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u6761\u4ef6\u4e0b\u3067\u3001\u901a\u5e38\u4f7f\u7528\u3057\u3066\u3044\u308b\u30ab\u30e9\u30e0\u306e\u5bff\u547d\u306f\u7d043\u304b\u6708\u3001\u6ce8\u5165\u56de\u6570\u306b\u3057\u3066\u7d041000\u56de\u7a0b\u5ea6\u3067\u3042\u308a\u300180\u301c90\u56de\u3054\u3068\u306b\u30ab\u30e9\u30e0\u30c8\u30ea\u30df\u30f3\u30b0\u304c\u5fc5\u8981\u3068\u306a\u308a\u307e\u3059\u3002RMX\u30ab\u30e9\u30e0\u3067\u306f1500\u56de\u306e\u6ce8\u5165\u307e\u3067\u4f7f\u7528\u3067\u304d\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u9593\u9694\u308290\u301c100\u56de\u307e\u3067\u5ef6\u9577\u3067\u304d\u307e\u3057\u305f\u3002\u3053\u308c\u306f\u30e9\u30dc\u306e\u751f\u7523\u6027\u306b\u76f4\u7d50\u3059\u308b\u5927\u304d\u306a\u6539\u5584\u3067\u3059\u3002<\/p>\n  <\/div>\n<\/div>\n\n<div class=\"rtk-qa-block\">\n  <div class=\"rtk-qa-q\">\n    <span class=\"rtk-qa-q-label\"><span class=\"rtk-qa-avatar rtk-avatar-host\">RD<\/span>Ramkumar<\/span>\n    <p>\u30b3\u30e1\u3092\u7279\u306b\u96e3\u3057\u3044\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3068\u3057\u3066\u6319\u3052\u3089\u308c\u307e\u3057\u305f\u304c\u3001\u4f55\u304c\u305d\u308c\u307b\u3069\u96e3\u3057\u304f\u3057\u3066\u3044\u308b\u306e\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n  <\/div>\n  <div class=\"rtk-qa-a rtk-qa-a-alexander\">\n    <span class=\"rtk-qa-a-label\"><span class=\"rtk-qa-avatar rtk-avatar-alexander\">AZ<\/span>Alexander<\/span>\n    <p>\u30b3\u30e1\u306f\u4e00\u898b\u5358\u7d14\u306b\u898b\u3048\u307e\u3059\u304c\u3001\u5b9f\u969b\u306b\u306f\u975e\u5e38\u306b\u8907\u96d1\u3067\u3059\u3002\u7279\u306b\u7384\u7c73\u306b\u306f\u3001QuEChERS\u62bd\u51fa\u3060\u3051\u3067\u306f\u5b8c\u5168\u306b\u9664\u53bb\u3057\u304d\u308c\u306a\u3044\u8102\u8cea\u3001\u8272\u7d20\u3001\u6bbb\u7531\u6765\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u304c\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002\u30b3\u30e1\u306e\u4e3b\u6210\u5206\u3067\u3042\u308b\u30c7\u30f3\u30d7\u30f3\u306f\u3001\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u306b\u307b\u3068\u3093\u3069\u6eb6\u89e3\u3057\u306a\u3044\u305f\u3081\u62bd\u51fa\u6db2\u4e2d\u306b\u6b8b\u308a\u306b\u304f\u304f\u3001\u3053\u306e\u70b9\u306f\u3080\u3057\u308d\u6709\u5229\u3067\u3059\u3002\u3057\u304b\u3057\u672c\u5f53\u306e\u554f\u984c\u306f\u3001\u5b9f\u969b\u306b\u62bd\u51fa\u3055\u308c\u308b\u53ef\u6eb6\u6027\u753b\u5206\u306b\u542b\u307e\u308c\u308b\u70ad\u6c34\u5316\u7269\u3067\u3059\u3002\u3053\u308c\u304c\u6ce8\u5165\u53e3\u306e\u9ad8\u6e29\u4e0b\u3067\u30ab\u30e9\u30e1\u30eb\u5316\u3057\u3001\u30e9\u30a4\u30ca\u30fc\u3084\u30ab\u30e9\u30e0\u30d8\u30c3\u30c9\u306b\u30ab\u30fc\u30dc\u30f3\u3068\u3057\u3066\u84c4\u7a4d\u3057\u307e\u3059\u3002\u6642\u9593\u304c\u7d4c\u3064\u3068\u3001\u3053\u306e\u30ab\u30fc\u30dc\u30f3\u306e\u84c4\u7a4d\u306b\u3088\u3063\u3066\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u304c\u6700\u3082\u5f71\u97ff\u3092\u53d7\u3051\u3084\u3059\u3044\u90e8\u4f4d\u306b\u3001\u65b0\u305f\u306a\u6d3b\u6027\u30b5\u30a4\u30c8\u304c\u5f62\u6210\u3055\u308c\u3066\u3057\u307e\u3044\u307e\u3059\u3002\u3053\u306e\u5bfe\u7b56\u3068\u3057\u3066\u3001PSA\u5145\u586b\u5264\u306b\u3088\u308b\u5f37\u529b\u306a\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u3068\u3001\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u3092\u7d44\u307f\u8fbc\u3093\u3060\u30ab\u30e9\u30e0\u30b7\u30b9\u30c6\u30e0\u306e\u4f75\u7528\u304c\u6709\u52b9\u3067\u3059\u3002<\/p>\n  <\/div>\n  <div class=\"rtk-qa-a rtk-qa-a-laura\">\n    <span class=\"rtk-qa-a-label\"><span class=\"rtk-qa-avatar rtk-avatar-laura\">LS<\/span>Laura<\/span>\n    <p>\u79c1\u305f\u3061\u306e\u691c\u8a0e\u3067\u306f\u3001RMX-5Sil MS with Integra-Guard\u3092\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u304c\u5206\u6790\u30ab\u30e9\u30e0\u3068\u540c\u4e00\u306e\u30c1\u30e5\u30fc\u30d6\u5185\u306b\u4e00\u4f53\u5316\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u30ea\u30fc\u30af\u304c\u751f\u3058\u3084\u3059\u3044\u624b\u52d5\u63a5\u7d9a\u3092\u907f\u3051\u3089\u308c\u307e\u3059\u3002\u3053\u306e\u69cb\u6210\u3067\u3042\u308c\u3070\u3001\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u6e08\u307f\u306e\u4fdd\u6301\u6642\u9593\u30a6\u30a3\u30f3\u30c9\u30a6\u3092\u5d29\u3059\u3053\u3068\u306a\u304f\u3001\u6c5a\u67d3\u3057\u305f\u30ab\u30e9\u30e0\u30d8\u30c3\u30c9\u3092\u30c8\u30ea\u30df\u30f3\u30b0\u3067\u304d\u307e\u3059\u3002\u3055\u3089\u306b\u3001TriMax\u4e0d\u6d3b\u6027\u5316\u6280\u8853\u306b\u3088\u308a\u3001\u5f93\u6765\u306e\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3067\u306f\u5bfe\u5fdc\u3057\u304d\u308c\u306a\u3044\u6c34\u6e96\u307e\u3067\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u7531\u6765\u306e\u6c5a\u67d3\u7269\u8cea\u304c\u84c4\u7a4d\u3059\u308b\u306e\u3092\u6291\u3048\u3089\u308c\u308b\u70b9\u3082\u91cd\u8981\u3067\u3059\u3002<\/p>\n  <\/div>\n<\/div>\n\n<h2>\u6280\u8853\u304c\u3082\u305f\u3089\u3059\u52b9\u679c<\/h2>\n\n<div class=\"rtk-qa-block\">\n  <div class=\"rtk-qa-q\">\n    <span class=\"rtk-qa-q-label\"><span class=\"rtk-qa-avatar rtk-avatar-host\">RD<\/span>Ramkumar<\/span>\n    <p>TriMax\u6280\u8853\u306f\u3001\u5f93\u6765\u306e\u30ab\u30e9\u30e0\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3068\u6bd4\u3079\u3066\u3001\u3069\u306e\u3088\u3046\u306b\u6027\u80fd\u304c\u7570\u306a\u308b\u306e\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n  <\/div>\n  <div class=\"rtk-qa-a rtk-qa-a-alexander\">\n    <span class=\"rtk-qa-a-label\"><span class=\"rtk-qa-avatar rtk-avatar-alexander\">AZ<\/span>Alexander<\/span>\n    <p>\u5f93\u6765\u306e\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3067\u306f\u3001GC\u6761\u4ef6\u306b\u7279\u5316\u3057\u3066\u8a2d\u8a08\u3055\u308c\u305f\u3082\u306e\u3067\u306f\u306a\u3044\u3001\u6c4e\u7528\u306e\u5de5\u696d\u7528\u30b7\u30ea\u30eb\u5316\u5264\u304c\u4f7f\u308f\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u6d3b\u6027\u30b7\u30e9\u30ce\u30fc\u30eb\u57fa\u304c\u9732\u51fa\u3057\u305f\u307e\u307e\u6b8b\u308a\u3001\u5fae\u91cf\u6fc3\u5ea6\u3067\u6d3b\u6027\u30b5\u30a4\u30c8\u3068\u53cd\u5fdc\u3057\u3084\u3059\u3044\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u5438\u7740\u3092\u5f15\u304d\u8d77\u3053\u3057\u307e\u3059\u3002TriMax\u6280\u8853\u306f\u3001Restek\u304c\u72ec\u81ea\u306b\u958b\u767a\u3057\u305f\u8a66\u85ac\u3068\u30d7\u30ed\u30bb\u30b9\u3067\u3042\u308a\u3001GC\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306e\u4e0d\u6d3b\u6027\u5316\u306e\u305f\u3081\u306b\u4e00\u304b\u3089\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3059\u3079\u3066\u306eRMX\u30ab\u30e9\u30e0\u306b\u63a1\u7528\u3055\u308c\u3066\u304a\u308a\u3001\u5358\u306a\u308b\u8868\u9762\u51e6\u7406\u306b\u3068\u3069\u307e\u3089\u305a\u3001\u7d50\u5408\u30fb\u67b6\u6a4b\u7d50\u5408\u30fb\u4e0d\u6d3b\u6027\u5316\u3092\u540c\u6642\u306b\u9032\u884c\u3055\u305b\u308b\u3053\u3068\u3067\u3001\u30b7\u30fc\u30e0\u30ec\u30b9\u306a\u4e09\u6b21\u5143\u69cb\u9020\u3092\u5f62\u6210\u3057\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u6b8b\u7559\u7269\u304c\u5c11\u306a\u304f\u3001\u9732\u51fa\u3057\u305f\u53cd\u5fdc\u6027\u30b5\u30a4\u30c8\u306e\u306a\u3044\u7dfb\u5bc6\u306a\u8868\u9762\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/p>\n    <p>\u3055\u3089\u306b\u91cd\u8981\u306a\u70b9\u3068\u3057\u3066\u3001\u67b6\u6a4b\u7d50\u5408\u306b\u3088\u3063\u3066\u56fa\u5b9a\u76f8\u306e\u69cb\u9020\u7684\u306a\u8010\u4e45\u6027\u3082\u9ad8\u307e\u308a\u307e\u3059\u3002\u5f53\u30e9\u30dc\u3067\u306f\u3001\u6570\u5343\u56de\u306e\u6ce8\u5165\u306b\u308f\u305f\u3063\u3066\u9ad8\u3044\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u8ca0\u8377\u306b\u3055\u3089\u3055\u308c\u3066\u3082\u3001\u52a3\u5316\u306b\u5bfe\u3059\u308b\u8010\u6027\u304c\u78ba\u8a8d\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u52a0\u3048\u3066\u3001RMX\u30ab\u30e9\u30e0\u306f\u9178\u6027\u5316\u5408\u7269\u30fb\u5869\u57fa\u6027\u5316\u5408\u7269\u30fb\u4e2d\u6027\u5316\u5408\u7269\u306e\u3044\u305a\u308c\u306b\u5bfe\u3057\u3066\u3082\u504f\u308a\u306e\u306a\u3044\u6319\u52d5\u3092\u793a\u3059\u3053\u3068\u3082\u78ba\u8a8d\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306f\u3001300\u6210\u5206\u3092\u8d85\u3048\u308b\u5316\u5b66\u7684\u306b\u591a\u69d8\u306a\u8fb2\u85ac\u3092\u5bfe\u8c61\u3068\u3059\u308b\u5206\u6790\u6cd5\u306b\u304a\u3044\u3066\u3001\u307e\u3055\u306b\u5fc5\u8981\u3068\u3055\u308c\u308b\u7279\u6027\u3067\u3059\u3002<\/p>\n  <\/div>\n<\/div>\n\n<div class=\"rtk-qa-block\">\n  <div class=\"rtk-qa-q\">\n    <span class=\"rtk-qa-q-label\"><span class=\"rtk-qa-avatar rtk-avatar-host\">RD<\/span>Ramkumar<\/span>\n    <p>\u98df\u54c1\u691c\u67fb\u3067\u306f\u5316\u5b66\u7684\u306b\u591a\u69d8\u306a\u8fb2\u85ac\u304c\u5bfe\u8c61\u3068\u306a\u308b\u3068\u3044\u3046\u304a\u8a71\u304b\u3089\u3001\u30e1\u30bd\u30c3\u30c9\u7d71\u5408\u306b\u3064\u3044\u3066\u3082\u6c17\u306b\u306a\u308a\u307e\u3057\u305f\u3002\u30e1\u30bd\u30c3\u30c9\u7d71\u5408\u304c\u9032\u3080\u4e2d\u3067\u3001\u30e9\u30dc\u304cGC\u30ab\u30e9\u30e0\u6280\u8853\u306b\u6c42\u3081\u308b\u6761\u4ef6\u306f\u3001\u3069\u306e\u3088\u3046\u306b\u5909\u308f\u3063\u3066\u304d\u3066\u3044\u308b\u306e\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n  <\/div>\n  <div class=\"rtk-qa-a rtk-qa-a-alexander\">\n    <span class=\"rtk-qa-a-label\"><span class=\"rtk-qa-avatar rtk-avatar-alexander\">AZ<\/span>Alexander<\/span>\n    <p>20\u5e74\u524d\u3067\u3042\u308c\u3070\u3001\u6709\u6a5f\u30ea\u30f3\u7cfb\u8fb2\u85ac\u3001\u6709\u6a5f\u5869\u7d20\u7cfb\u8fb2\u85ac\u3001\u63ee\u767a\u6027\u8fb2\u85ac\u306f\u305d\u308c\u305e\u308c\u5225\u306e\u30ab\u30e9\u30e0\u3068\u30e1\u30bd\u30c3\u30c9\u3067\u306e\u5206\u6790\u304c\u4e00\u822c\u7684\u3067\u3057\u305f\u3002\u5404\u30e1\u30bd\u30c3\u30c9\u304c\u3001\u72ed\u3044\u5316\u5408\u7269\u30af\u30e9\u30b9\u306b\u6700\u9069\u5316\u3055\u308c\u3066\u3044\u305f\u306e\u3067\u3059\u3002\u30e1\u30bd\u30c3\u30c9\u7d71\u5408\u3068\u306f\u3001\u3053\u308c\u3089\u3059\u3079\u3066\u30921\u672c\u306e\u30ab\u30e9\u30e0\u306b\u307e\u3068\u3081\u3001300\u7a2e\u985e\u3092\u8d85\u3048\u308bGC\u5206\u6790\u5bfe\u8c61\u8fb2\u85ac\u30921\u56de\u306e\u30b7\u30fc\u30b1\u30f3\u30b9\u3067\u5206\u6790\u3059\u308b\u3053\u3068\u3092\u610f\u5473\u3057\u307e\u3059\u3002\u62bd\u51fa\u3082\u6ce8\u5165\u30821\u56de\u3067\u6e08\u307f\u3001\u7d50\u679c\u3082\u4e00\u62ec\u3057\u3066\u5f97\u3089\u308c\u308b\u305f\u3081\u3001\u52b9\u7387\u5316\u306e\u30e1\u30ea\u30c3\u30c8\u306f\u975e\u5e38\u306b\u5927\u304d\u3044\u3068\u3044\u3048\u307e\u3059\u3002<\/p>\n    <p>\u4e00\u65b9\u3067\u3001\u30ab\u30e9\u30e0\u306b\u306f\u3001\u6975\u6027\u5316\u5408\u7269\u3001\u7121\u6975\u6027\u5316\u5408\u7269\u3001\u71b1\u306b\u4e0d\u5b89\u5b9a\u306a\u5316\u5408\u7269\u306a\u3069\u3001\u5e45\u5e83\u3044\u6027\u8cea\u306e\u5316\u5408\u7269\u3092\u504f\u308a\u306a\u304f\u6271\u3046\u6027\u80fd\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002\u6709\u6a5f\u5869\u7d20\u7cfb\u8fb2\u85ac\u306b\u306f\u826f\u597d\u306a\u6027\u80fd\u3092\u793a\u3057\u3066\u3082\u3001\u6709\u6a5f\u30ea\u30f3\u9178\u30a8\u30b9\u30c6\u30eb\u7cfb\u8fb2\u85ac\u3067\u30c6\u30fc\u30ea\u30f3\u30b0\u3092\u8d77\u3053\u3059\u30ab\u30e9\u30e0\u306f\u3001\u7d71\u5408\u3055\u308c\u305f\u30e1\u30bd\u30c3\u30c9\u306b\u306f\u9069\u3057\u3066\u3044\u307e\u305b\u3093\u3002\u3060\u304b\u3089\u3053\u305d\u3001RMX\u30ab\u30e9\u30e0\u304c\u793a\u3059\u9178\u6027\u5316\u5408\u7269\u30fb\u5869\u57fa\u6027\u5316\u5408\u7269\u30fb\u4e2d\u6027\u5316\u5408\u7269\u9593\u3067\u540c\u7b49\u306e\u56de\u53ce\u7387\u3092\u5f97\u3089\u308c\u308b\u504f\u308a\u306e\u306a\u3044\u6027\u80fd\u306f\u3001\u73fe\u4ee3\u306e\u98df\u54c1\u691c\u67fb\u306b\u3068\u3063\u3066\u3001\u5358\u306b\u671b\u307e\u3057\u3044\u7279\u6027\u306b\u3068\u3069\u307e\u3089\u305a\u3001\u5fc5\u9808\u306e\u8981\u4ef6\u3068\u3044\u3048\u307e\u3059\u3002<\/p>\n  <\/div>\n  <div class=\"rtk-qa-a rtk-qa-a-laura\">\n    <span class=\"rtk-qa-a-label\"><span class=\"rtk-qa-avatar rtk-avatar-laura\">LS<\/span>Laura<\/span>\n    <p>\u5b9f\u4f8b\u3092\u6319\u3052\u307e\u3059\u3068\u3001\u5f53\u30e9\u30dc\u306eGC\u591a\u6210\u5206\u6b8b\u7559\u8fb2\u85ac\u5206\u6790\u6cd5\u306f\u3001350\u301c380\u7a2e\u985e\u306e\u8fb2\u85ac\u3092\u5bfe\u8c61\u3068\u3057\u3066\u304a\u308a\u3001\u975e\u5e38\u306b\u5e45\u5e83\u3044\u5316\u5408\u7269\u30bf\u30a4\u30d7\u3068\u591a\u304f\u306e\u96e3\u5206\u6790\u6027\u5316\u5408\u7269\u3092\u542b\u3093\u3067\u3044\u307e\u3059\u3002\u96e3\u3057\u3044\u306e\u306f\u3001\u305d\u308c\u3089\u3059\u3079\u3066\u3092\u5206\u6790\u3059\u308b\u3053\u3068\u81ea\u4f53\u3067\u306f\u306a\u304f\u3001\u96e3\u6613\u5ea6\u306e\u9ad8\u3044\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u4e2d\u3067\u3001\u6570\u767e\u56de\u306e\u6ce8\u5165\u306b\u308f\u305f\u3063\u3066\u3001\u3059\u3079\u3066\u306e\u5316\u5408\u7269\u3092\u4e00\u8cab\u3057\u3066\u5b9a\u91cf\u3057\u7d9a\u3051\u308b\u3053\u3068\u3067\u3059\u3002RMX-5Sil MS\u30ab\u30e9\u30e0\u304c\u305d\u306e\u5168\u7bc4\u56f2\u306b\u308f\u305f\u3063\u3066\u793a\u3059\u6027\u80fd\u306e\u5b89\u5b9a\u6027\u3053\u305d\u304c\u3001\u5927\u898f\u6a21\u306a\u30e1\u30bd\u30c3\u30c9\u7d71\u5408\u3092\u5b9f\u73fe\u53ef\u80fd\u306b\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n  <\/div>\n<\/div>\n\n<div class=\"rtk-qa-block\">\n  <div class=\"rtk-qa-q\">\n    <span class=\"rtk-qa-q-label\"><span class=\"rtk-qa-avatar rtk-avatar-host\">RD<\/span>Ramkumar<\/span>\n    <p>\u5148\u307b\u3069\u3001\u4e00\u4f53\u578b\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306b\u3064\u3044\u3066\u89e6\u308c\u3066\u3044\u305f\u3060\u304d\u307e\u3057\u305f\u304c\u3001\u304a\u4f7f\u3044\u306eRMX\u30ab\u30e9\u30e0\u306b\u306f\u4e00\u4f53\u578b\u306eMS\u30c8\u30e9\u30f3\u30b9\u30d5\u30a1\u30e9\u30a4\u30f3\u3082\u642d\u8f09\u3055\u308c\u3066\u3044\u308b\u3068\u4f3a\u3044\u307e\u3057\u305f\u3002\u3053\u306e\u30c7\u30e5\u30a2\u30eb\u5f62\u5f0f\u306b\u306f\u3001\u3069\u306e\u3088\u3046\u306a\u5229\u70b9\u304c\u3042\u308b\u306e\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n  <\/div>\n  <div class=\"rtk-qa-a rtk-qa-a-alexander\">\n    <span class=\"rtk-qa-a-label\"><span class=\"rtk-qa-avatar rtk-avatar-alexander\">AZ<\/span>Alexander<\/span>\n    <p>GC\u30ab\u30e9\u30e0\u306e\u69cb\u9020\u8a2d\u8a08\u306f\u3001\u30ab\u30e9\u30e0\u306e\u5316\u5b66\u7684\u6027\u8cea\u3068\u540c\u69d8\u306b\u91cd\u8981\u3067\u3059\u3002\u98df\u54c1\u6b8b\u7559\u8fb2\u85ac\u5206\u6790\u3067\u306f\u3001\u6ce8\u5165\u53e3\u3068\u30ab\u30e9\u30e0\u30d8\u30c3\u30c9\u304c\u6700\u3082\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6c5a\u67d3\u306e\u5f71\u97ff\u3092\u53d7\u3051\u3084\u3059\u3044\u90e8\u4f4d\u3067\u3059\u3002Integra-Guard\u5f62\u5f0f\u306f\u3001\u5206\u6790\u30ab\u30e9\u30e0\u3068\u540c\u4e00\u306e\u30c1\u30e5\u30fc\u30d6\u5185\u306b\u30b7\u30fc\u30e0\u30ec\u30b9\u306b\u4e00\u4f53\u5316\u3055\u308c\u305f\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u3067\u3042\u308a\u3001\u624b\u52d5\u63a5\u7d9a\u306f\u5fc5\u8981\u306a\u304f\u3001\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u3082\u751f\u3058\u305a\u3001\u30ea\u30fc\u30af\u306e\u61f8\u5ff5\u3082\u3042\u308a\u307e\u305b\u3093\u3002\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u304c\u6c5a\u67d3\u3055\u308c\u305f\u5834\u5408\u306f\u3001\u30c8\u30ea\u30df\u30f3\u30b0\u3059\u308b\u3060\u3051\u3067\u6e08\u307f\u307e\u3059\u3002\u91cd\u8981\u306a\u70b9\u3068\u3057\u3066\u3001\u30ab\u30e9\u30e0\u30c8\u30ea\u30df\u30f3\u30b0\u3092\u884c\u3063\u3066\u3082\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u4fdd\u6301\u6642\u9593\u30a6\u30a3\u30f3\u30c9\u30a6\u306f\u5909\u5316\u3057\u307e\u305b\u3093\u3002\u3064\u307e\u308a\u3001\u30e1\u30bd\u30c3\u30c9\u306e\u518d\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u3082\u518d\u6821\u6b63\u3082\u4e0d\u8981\u3067\u3059\u30021\u65e5\u306b\u6570\u5341\u30b5\u30f3\u30d7\u30eb\u3001200\u301c300\u6210\u5206\u3092\u5206\u6790\u3059\u308b\u30e9\u30dc\u306b\u3068\u3063\u3066\u3001\u3053\u308c\u306f\u975e\u5e38\u306b\u5927\u304d\u306a\u6642\u9593\u306e\u7bc0\u7d04\u306b\u3064\u306a\u304c\u308a\u307e\u3059\u3002<\/p>\n    <p>Integra-transfer line\u306f\u3001\u5225\u306e\u8ab2\u984c\u3092\u89e3\u6c7a\u3057\u307e\u3059\u3002\u305d\u308c\u306f\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a1\u30e9\u30a4\u30f3\u81ea\u4f53\u304b\u3089\u30a4\u30aa\u30f3\u6e90\u3078\u306e\u6f0f\u51fa\u3001\u3044\u308f\u3086\u308b\u30d6\u30ea\u30fc\u30c9\u3067\u3059\u3002\u30c8\u30e9\u30f3\u30b9\u30d5\u30a1\u30e9\u30a4\u30f3\u306f300\u301c310\u00b0C\u306b\u4fdd\u305f\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u6e29\u5ea6\u3067\u56fa\u5b9a\u76f8\u304c\u5b58\u5728\u3059\u308b\u3068\u3001\u8cea\u91cf\u5206\u6790\u8a08\u306e\u30a4\u30aa\u30f3\u6e90\u3078\u7d99\u7d9a\u7684\u306b\u30d6\u30ea\u30fc\u30c9\u304c\u751f\u3058\u307e\u3059\u3002Integra-transfer line\u306f\u3001\u56fa\u5b9a\u76f8\u3092\u542b\u307e\u306a\u3044TriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u6e08\u307f\u306e\u30c1\u30e5\u30fc\u30d6\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u305f\u3081\u3001\u30d6\u30ea\u30fc\u30c9\u3092\u5927\u5e45\u306b\u4f4e\u6e1b\u3067\u304d\u307e\u3059\u3002\u30a4\u30aa\u30f3\u6e90\u306e\u6c5a\u67d3\u304c\u6e1b\u308b\u3053\u3068\u3067\u3001\u30a4\u30aa\u30f3\u6e90\u306e\u6d17\u6d44\u983b\u5ea6\u304c\u4e0b\u304c\u308a\u3001\u5316\u5b66\u7684\u30ce\u30a4\u30ba\u304c\u6e1b\u5c11\u3057\u3001\u5fae\u91cf\u6210\u5206\u306b\u5bfe\u3059\u308bSN\u6bd4\u304c\u5411\u4e0a\u3057\u307e\u3059\u3002<\/p>\n    <p>Integra-Guard\u3068Integra-transfer line\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u30c7\u30e5\u30a2\u30eb\u5f62\u5f0f\u306eRMX-5Sil MS\u30ab\u30e9\u30e0\u306f\u3001\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u3068\u30c8\u30e9\u30f3\u30b9\u30d5\u30a1\u30e9\u30a4\u30f3\u306e\u4e21\u65b9\u306e\u6a5f\u80fd\u30921\u672c\u306e\u30ab\u30e9\u30e0\u306b\u96c6\u7d04\u3057\u3066\u304a\u308a\u3001\u6d41\u8def\u306e\u3069\u3053\u306b\u3082\u5916\u90e8\u63a5\u7d9a\u3092\u6301\u3061\u307e\u305b\u3093\u3002\u54c1\u756a\u30821\u3064\u306b\u307e\u3068\u307e\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n  <\/div>\n<\/div>\n\n<div class=\"rtk-qa-block\">\n  <div class=\"rtk-qa-q\">\n    <span class=\"rtk-qa-q-label\"><span class=\"rtk-qa-avatar rtk-avatar-host\">RD<\/span>Ramkumar<\/span>\n    <p>\u3053\u3053\u307e\u3067GC\u30ab\u30e9\u30e0\u6280\u8853\u306e\u91cd\u8981\u6027\u306b\u3064\u3044\u3066\u8a73\u3057\u304f\u4f3a\u3044\u307e\u3057\u305f\u304c\u3001\u6ce8\u5165\u53e3\u306b\u3064\u3044\u3066\u3082\u89e6\u308c\u3066\u3044\u305f\u3060\u304d\u307e\u3057\u305f\u306e\u3067\u3001\u6700\u5f8c\u306b\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306b\u3064\u3044\u3066\u4f3a\u3044\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002\u30e9\u30a4\u30ca\u30fc\u306f\u6b8b\u7559\u8fb2\u85ac\u5206\u6790\u306b\u3069\u306e\u3088\u3046\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u306e\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n  <\/div>\n  <div class=\"rtk-qa-a rtk-qa-a-alexander\">\n    <span class=\"rtk-qa-a-label\"><span class=\"rtk-qa-avatar rtk-avatar-alexander\">AZ<\/span>Alexander<\/span>\n    <p>\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306f\u975e\u5e38\u306b\u91cd\u8981\u306a\u90e8\u6750\u3067\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u304c\u5206\u6790\u30b7\u30b9\u30c6\u30e0\u306b\u6700\u521d\u306b\u63a5\u89e6\u3059\u308b\u5834\u6240\u3067\u3042\u308a\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u8fb2\u85ac\u5206\u6790\u3067\u306f\u901a\u5e38250\u301c280\u00b0C\u3068\u3044\u3046\u9ad8\u6e29\u306b\u4fdd\u305f\u308c\u3066\u3044\u307e\u3059\u3002\u9ad8\u6e29\u306b\u52a0\u3048\u3066\u8868\u9762\u306e\u53cd\u5fdc\u6027\u307e\u3067\u9ad8\u3044\u3068\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u4e2d\u3067\u3082\u6700\u3082\u6d3b\u6027\u306e\u9ad8\u3044\u5316\u5408\u7269\u306f\u3001\u30ab\u30e9\u30e0\u306b\u5230\u9054\u3059\u308b\u524d\u306b\u5206\u89e3\u3057\u3066\u3057\u307e\u3044\u307e\u3059\u3002\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u304c\u4e0d\u5341\u5206\u306a\u30e9\u30a4\u30ca\u30fc\u3067\u306f\u3001\u6d3b\u6027\u30b7\u30e9\u30ce\u30fc\u30eb\u57fa\u304c\u30d5\u30a7\u30ce\u30fc\u30eb\u7cfb\u8fb2\u85ac\u3068\u6c34\u7d20\u7d50\u5408\u3092\u5f62\u6210\u3057\u307e\u3059\u3002\u30d9\u30f3\u30ba\u30a4\u30df\u30c0\u30be\u30fc\u30eb\u985e\u306e\u3088\u3046\u306a\u5869\u57fa\u6027\u5316\u5408\u7269\u306f\u3001\u4e0d\u53ef\u9006\u7684\u306b\u5438\u7740\u3059\u308b\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002\u65e2\u77e5\u306e\u6fc3\u5ea6\u3092\u6ce8\u5165\u3057\u305f\u3064\u3082\u308a\u3067\u3082\u3001\u305d\u306e\u4e00\u90e8\u304c\u6ce8\u5165\u53e3\u3092\u901a\u904e\u3067\u304d\u305a\u306b\u5931\u308f\u308c\u3066\u3057\u307e\u3046\u306e\u3067\u3059\u3002<\/p>\n    <p>\u3053\u306e\u3088\u3046\u306a\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u5206\u89e3\u3092\u9632\u3050\u305f\u3081\u3001\u79c1\u305f\u3061\u306fTopaz\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3057\u3066\u3044\u307e\u3059\u3002\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u304c\u5b9f\u8a3c\u3055\u308c\u3066\u304a\u308a\u3001\u30b0\u30e9\u30b9\u30a6\u30fc\u30eb\u90e8\u5206\u306b\u307e\u3067\u53ca\u3076\u30d7\u30ec\u30df\u30a2\u30e0\u306a\u30b7\u30ea\u30b3\u30f3\u7cfb\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u304c\u65bd\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3067\u3059\u3002Topaz\u30e9\u30a4\u30ca\u30fc\u3067\u306f\u3001\u6ce8\u5165\u53e3\u306e\u4e0d\u6d3b\u6027\u5ea6\u3092\u8a55\u4fa1\u3059\u308b\u969b\u306e\u6307\u6a19\u5316\u5408\u7269\u3068\u3057\u3066\u5e83\u304f\u4f7f\u308f\u308c\u308b\u30a8\u30f3\u30c9\u30ea\u30f3\u3068DDT\u306b\u3064\u3044\u3066\u3001\u5206\u89e3\u306e\u6c34\u6e96\u304c\u975e\u5e38\u306b\u4f4e\u304f\u6291\u3048\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u306b\u52a0\u3048\u3066\u3001\u30e9\u30a4\u30ca\u30fc\u5f62\u72b6\u306f\u6ce8\u5165\u30e2\u30fc\u30c9\u306b\u5fdc\u3058\u3066\u9078\u629e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3067\u306f\u4e2d\u592e\u306b\u30b0\u30e9\u30b9\u30a6\u30fc\u30eb\u3092\u914d\u7f6e\u3057\u305f\u30e9\u30a4\u30ca\u30fc\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3067\u306f\u30d0\u30c3\u30d5\u30eb\u5f62\u72b6\u306e\u30e9\u30a4\u30ca\u30fc\u3092\u7528\u3044\u308b\u3053\u3068\u3067\u3001\u6c17\u5316\u3057\u305f\u30ac\u30b9\u3092\u9069\u5207\u306b\u96c6\u675f\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n  <\/div>\n  <div class=\"rtk-qa-a rtk-qa-a-laura\">\n    <span class=\"rtk-qa-a-label\"><span class=\"rtk-qa-avatar rtk-avatar-laura\">LS<\/span>Laura<\/span>\n    <p>\u4eca\u56de\u306e\u691c\u8a0e\u3067\u306f\u3001Topaz\u30d0\u30c3\u30d5\u30eb\u30e9\u30a4\u30ca\u30fc\u3092RMX-5Sil MS\u30ab\u30e9\u30e0\u3068\u7d44\u307f\u5408\u308f\u305b\u3066\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002\u30e9\u30a4\u30ca\u30fc\u306e\u30c7\u30fc\u30bf\u304b\u3089\u660e\u3089\u304b\u306b\u306a\u3063\u305f\u306e\u306f\u3001\u30e9\u30a4\u30ca\u30fc\u306e\u4f7f\u7528\u671f\u9593\u5168\u4f53\u3092\u901a\u3058\u3066\u3001\u6700\u3082\u6d3b\u6027\u306e\u9ad8\u3044\u5316\u5408\u7269\u304c\u4e00\u8cab\u3057\u3066\u4fdd\u8b77\u3055\u308c\u3066\u3044\u305f\u3053\u3068\u3067\u3059\u3002\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u9593\u9694\u30926\u672c\u304b\u30898\u672c\u306e\u30e9\u30a4\u30ca\u30fc\u307e\u3067\u5ef6\u9577\u3057\u3001\u30b7\u30b9\u30c6\u30e0\u306b\u5927\u304d\u306a\u8ca0\u8377\u3092\u304b\u3051\u305f\u5834\u5408\u3067\u3082\u3001RMX\u30ab\u30e9\u30e0\u3068\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3092\u6301\u3064Topaz\u30e9\u30a4\u30ca\u30fc\u306e\u7d44\u307f\u5408\u308f\u305b\u306b\u3088\u308a\u3001\u5bfe\u8c61\u8fb2\u85ac\u306e\u5927\u90e8\u5206\u306b\u3064\u3044\u3066\u3001\u8a31\u5bb9\u7bc4\u56f2\u5185\u306e\u56de\u53ce\u7387\u3092\u7dad\u6301\u3067\u304d\u307e\u3057\u305f\u3002<\/p>\n    <p>\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u3068GC\u30ab\u30e9\u30e0\u306f\u3001\u307e\u3055\u306b\u4e00\u4f53\u3068\u306a\u3063\u3066\u6a5f\u80fd\u3057\u307e\u3059\u3002\u512a\u308c\u305f\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u3066\u3044\u3066\u3082\u6700\u3082\u6d3b\u6027\u306e\u9ad8\u3044\u5316\u5408\u7269\u304c\u30ab\u30e9\u30e0\u306b\u5230\u9054\u3059\u308b\u524d\u306b\u30e9\u30a4\u30ca\u30fc\u306b\u3088\u3063\u3066\u5206\u89e3\u3055\u308c\u3066\u3057\u307e\u3063\u305f\u3089\u3001\u30c7\u30fc\u30bf\u306e\u54c1\u8cea\u306f\u640d\u306a\u308f\u308c\u307e\u3059\u3002GC\u30ab\u30e9\u30e0\u3068\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u56de\u53ce\u7387\u306b\u5171\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u305f\u3081\u3001\u30b7\u30b9\u30c6\u30e0\u3068\u3057\u3066\u6700\u9069\u5316\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n  <\/div>\n<\/div>\n\n<div class=\"rtk-qa-block\">\n  <div class=\"rtk-qa-q\">\n    <span class=\"rtk-qa-q-label\"><span class=\"rtk-qa-avatar rtk-avatar-host\">RD<\/span>Ramkumar<\/span>\n    <p>\u672c\u65e5\u306f\u5927\u5909\u8208\u5473\u6df1\u3044\u304a\u8a71\u3092\u3042\u308a\u304c\u3068\u3046\u3054\u3056\u3044\u307e\u3057\u305f\u3002<\/p>\n  <\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<style data-wp-block-html=\"css\">\n<style>\n\/* ===== \u30d9\u30fc\u30b9\uff1artk-article-style.css\uff08\u5171\u901a\uff09 ===== *\/\n.rtk-article { line-height: 1.8; font-size: 17px; }\n\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n\n.rtk-article h2 {\n  margin-top: 4em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n\n.rtk-article h3 {\n  margin-top: 2.4em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n\n.rtk-article p {\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n\n.rtk-article .rtk-lead {\n  font-size: 16px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n\n.rtk-article blockquote.rtk-voc {\n  position: relative;\n  border-left: 4px solid #00265d;\n  background: #f7f8f9;\n  padding: 18px 22px 18px 30px;\n  margin: 2em 0;\n  font-style: italic;\n  color: #333;\n}\n.rtk-article blockquote.rtk-voc p { margin-bottom: 0.4em; }\n.rtk-article blockquote.rtk-voc cite {\n  display: block;\n  font-style: normal;\n  font-size: 13px;\n  color: #4a4a4a;\n}\n\n.rtk-article .rtk-coa-list {\n  list-style: none;\n  padding: 0;\n}\n.rtk-article .rtk-coa-list li {\n  background: #fafbfc;\n  border: 1px solid #e1e8ec;\n  border-radius: 6px;\n  padding: 14px 18px;\n  margin-bottom: 12px;\n}\n\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 2.8em; }\n  .rtk-article h3 { margin-top: 1.8em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout,\n  .rtk-article blockquote.rtk-voc {\n    padding: 14px 16px;\n  }\n}\n\n\/* ===== \u3053\u306e\u8a18\u4e8b\u5c02\u7528\u306e\u8ffd\u52a0\u30b9\u30bf\u30a4\u30eb\uff08\u5bfe\u8ac7\u5f62\u5f0f\u306eQ&A\u8868\u793a\uff09 =====\n   \u30b9\u30b3\u30fc\u30d7\u306f .rtk-article.rtk-article \u3067\u4e8c\u91cd\u30af\u30e9\u30b9\u5316\u3057\u3001\n   \u5171\u901a\u30b9\u30bf\u30a4\u30eb\u30b7\u30fc\u30c8\uff08rtk-article-style.css\uff09\u306b\u306f\u5f71\u97ff\u3057\u306a\u3044\u5f62\u306b\u3057\u3066\u3044\u307e\u3059\u3002 *\/\n\n.rtk-article.rtk-article .rtk-subtitle {\n  margin-top: -0.6em;\n  margin-bottom: 2em;\n  color: #5a6b78;\n  font-size: 15px;\n}\n\n.rtk-article.rtk-article .rtk-qa-block {\n  margin: 0 0 1.4em;\n}\n\n\/* Ramkumar\uff08\u9032\u884c\u5f79\uff09\u306e\u8cea\u554f\u30fb\u30b3\u30e1\u30f3\u30c8\uff1a\u67d4\u3089\u304b\u3044\u8584\u6c34\u8272\u306e\u30dc\u30c3\u30af\u30b9 *\/\n.rtk-article.rtk-article .rtk-qa-q {\n  background: #f5f9fc;\n  border-radius: 10px;\n  padding: 14px 20px 12px;\n  margin: 1.8em 0 1em;\n}\n.rtk-article.rtk-article .rtk-qa-q p {\n  margin: 4px 0 0;\n  font-style: italic;\n  color: #33475b;\n}\n\n\/* \u30b2\u30b9\u30c8\uff08Alexander \/ Laura\uff09\u306e\u56de\u7b54\uff1a\u5de6\u30ab\u30e9\u30fc\u30e9\u30a4\u30f3\u3067\u30b9\u30d4\u30fc\u30ab\u30fc\u3092\u533a\u5225 *\/\n.rtk-article.rtk-article .rtk-qa-a {\n  border-left: 4px solid #0d7bc4;\n  border-radius: 0 8px 8px 0;\n  padding: 2px 20px;\n  margin: 0 0 1.2em;\n}\n.rtk-article.rtk-article .rtk-qa-a-laura {\n  border-left-color: #1a8f7b;\n}\n.rtk-article.rtk-article .rtk-qa-a p {\n  margin: 4px 0 0.6em;\n}\n\n\/* \u30b9\u30d4\u30fc\u30ab\u30fc\u30e9\u30d9\u30eb\uff08\u30a2\u30d0\u30bf\u30fc\uff0b\u540d\u524d\uff09 *\/\n.rtk-article.rtk-article .rtk-qa-q-label,\n.rtk-article.rtk-article .rtk-qa-a-label {\n  display: inline-flex;\n  align-items: center;\n  gap: 8px;\n  font-weight: 700;\n  font-size: 14px;\n  color: #22314f;\n}\n.rtk-article.rtk-article .rtk-qa-avatar {\n  display: inline-flex;\n  align-items: center;\n  justify-content: center;\n  width: 26px;\n  height: 26px;\n  border-radius: 50%;\n  color: #fff;\n  font-size: 11px;\n  font-weight: 700;\n  flex: none;\n}\n.rtk-article.rtk-article .rtk-avatar-host { background: #6b7a90; }\n.rtk-article.rtk-article .rtk-avatar-alexander { background: #0d7bc4; }\n.rtk-article.rtk-article .rtk-avatar-laura { background: #1a8f7b; }\n\n\/* \u8a18\u4e8b\u672b\u5c3e\u306eCTA\u30ea\u30f3\u30af *\/\n.rtk-article.rtk-article .rtk-cta-list {\n  list-style: none;\n  padding: 0;\n  margin: 0;\n}\n.rtk-article.rtk-article .rtk-cta-list li {\n  margin-bottom: 10px;\n}\n.rtk-article.rtk-article .rtk-cta-list a {\n  font-weight: 700;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article.rtk-article .rtk-qa-q,\n  .rtk-article.rtk-article .rtk-qa-a {\n    padding-left: 14px;\n    padding-right: 14px;\n  }\n}\n<\/style>\n<\/style>\n\n<div class=\"rtk-article\">\n<h2>RMX\u30ab\u30e9\u30e0\u304c\u3082\u305f\u3089\u3059\u53ef\u80fd\u6027\u306b\u3064\u3044\u3066\u3001\u3082\u3063\u3068\u77e5\u308a\u305f\u3044\u65b9\u3078<\/h2>\n\n<p>\u4eca\u56de\u3054\u7d39\u4ecb\u3057\u305fRMX\u30ab\u30e9\u30e0\uff08TriMax\u6280\u8853\u63a1\u7528\uff09\u3001Topaz\u30e9\u30a4\u30ca\u30fc\u3001Integra-Guard\u5f62\u5f0f\u304c\u3001\u5b9f\u969b\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3092\u3069\u306e\u3088\u3046\u306b\u6539\u5584\u3067\u304d\u308b\u304b\u3001\u305c\u3072\u4ee5\u4e0b\u306e\u30ea\u30bd\u30fc\u30b9\u304b\u3089\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/ja\/rmx\/\">Explore RMX<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/rmx?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noopener\">Order RMX GC Columns<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1484\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/c\/1484\" target=\"_blank\" rel=\"noopener\">Order Topaz Inlet Liners<\/a> <\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/contact-us\" target=\"_blank\" rel=\"noopener\">Questions? Contact Us<\/a> <\/li>\n<\/ul>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u95a2\u9023\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323\">                                \u30ab\u30bf\u30ed\u30b0No. 17323                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">RMX-5Sil MS GC\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0, 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323-124\">                                \u30ab\u30bf\u30ed\u30b0No. 17323-124                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">RMX-5Sil MS GC\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0, 30 m, 0.25 mm ID, 0.25 \u00b5m, 5 m Integra-Guard\u4ed8\u304d<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323-124\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323-124177\">                                \u30ab\u30bf\u30ed\u30b0No. 17323-124177                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">RMX-5Sil MS GC\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0, 30 m, 0.25 mm ID, 0.25 \u00b5m, 5 m Integra-Guard &amp; Integra-Transfer Line\u4ed8\u304d<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323-124177\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">                                \u30ab\u30bf\u30ed\u30b0No. 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Restek \u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22656\">                                \u30ab\u30bf\u30ed\u30b0No. 22656                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Restek ProFLOW 6000 \u6d41\u91cf\u8a08<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22656\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u98df\u54c1\u691c\u67fb\u30e9\u30dc\u306f\u3001\u3042\u3089\u3086\u308b\u65b9\u5411\u304b\u3089\u306e\u30d7\u30ec\u30c3\u30b7\u30e3\u30fc\u306b\u3055\u3089\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u898f\u5236\u5f53\u5c40\u306f\u6700\u5927\u6b8b\u7559\u57fa\u6e96\u5024\uff08MRL\uff09\u3092\u53b3\u683c\u5316\u3057\u3066\u304a\u308a\u3001\u5869\u7d20\u7cfb\u6eb6\u5a92\u306e\u4f7f\u7528\u7981\u6b62\u306b\u3088\u3063\u3066\u524d\u51e6\u7406\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3082\u898b\u76f4\u3057\u3092\u8feb\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u8fb2\u85ac\u5206\u6790\u5bfe\u8c61\u30ea\u30b9\u30c8\u306f700\u6210\u5206\u3092\u8d85\u3048\u308b\u898f\u6a21\u306b\u62e1\u5927\u3057\u307e\u3057\u305f\u3002\u305d\u306e\u4e00\u65b9\u3067\u3001\u7d0d\u671f\u306f\u65e5\u5358\u4f4d\u3067\u306f\u306a\u304f\u6642\u9593\u5358\u4f4d\u3067\u6c42\u3081\u3089\u308c\u308b\u3088\u3046\u306b\u306a\u3063\u3066\u3044\u307e\u3059\u3002 \u3082\u306f\u3084\u554f\u984c\u306f\u3001GC-MS\/MS\u3067\u5fae\u91cf\u306e\u8fb2\u85ac\u3092\u691c\u51fa\u3067\u304d\u308b\u304b\u3069\u3046\u304b\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u6700\u65b0\u306e\u30c8\u30ea\u30d7\u30eb\u56db\u91cd\u6975\u578b\u88c5\u7f6e\u306b\u3088\u308a\u3001\u3053\u306e\u8ab2\u984c\u306f\u3059\u3067\u306b\u89e3\u6c7a\u6e08\u307f\u3068\u3044\u3048\u307e\u3059\u3002\u771f\u306e\u8ab2\u984c\u306f\u3001GC\u30ab\u30e9\u30e0\u3068\u6ce8\u5165\u53e3\u90e8\u6750\u304c\u3001\u6975\u3081\u3066\u593e\u96d1\u7269\u306e\u591a\u3044\u98df\u54c1\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3092\u5bfe\u8c61\u3068\u3057\u305f\u6570\u5343\u56de\u306e\u6ce8\u5165\u306b\u8010\u3048\u3089\u308c\u308b\u304b\u3069\u3046\u304b\u306b\u3042\u308a\u307e\u3059\u3002 \u4eca\u56de\u306e\u5bfe\u8ac7\u3067\u306f\u3001Restek \u306e Ramkumar Dhandapani\uff08\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u91ce\u306723\u5e74\u4ee5\u4e0a\u306e\u7d4c\u9a13\u3092\u6301\u3064\u5206\u6790\u5316\u5b66\u535a\u58eb\u3001\u30d7\u30ed\u30c0\u30af\u30c8\u30de\u30cd\u30b8\u30e1\u30f3\u30c8\u90e8\u9580\u30c7\u30a3\u30ec\u30af\u30bf\u30fc\uff09\u304c\u3001\u30c9\u30a4\u30c4\u306e Eurofins \u793e\u30e9\u30dc\u306b\u6240\u5c5e\u3059\u308b Dr. Alexander Zahm \u6c0f\u304a\u3088\u3073 Laura Sch\u00fctz \u6c0f\u3068\u3068\u3082\u306b\u3001\u98df\u54c1\u5b89\u5168\u6027\u8a66\u9a13\u3092\u53d6\u308a\u5dfb\u304f\u5909\u5316\u3068\u73fe\u5728\u306e\u8ab2\u984c\u306b\u3064\u3044\u3066\u8a9e\u308a\u5408\u3044\u307e\u3057\u305f\u3002 \u30b2\u30b9\u30c8\u30a8\u30ad\u30b9\u30d1\u30fc\u30c8\u7d39\u4ecb\uff5cEurofins Dr. Specht Express Testing &amp; Inspection GmbH \u30e9\u30dc\u904b\u55b6\u3068\u30d9\u30f3\u30c1\u30ef\u30fc\u30af\u3001\u4e8c\u3064\u306e\u8996\u70b9 RDRamkumar \u672c\u65e5\u306f\u3001\u6b8b\u7559\u8fb2\u85ac\u5206\u6790\u306b\u95a2\u3059\u308b\u77e5\u898b\u3092\u5171\u6709\u3057\u3066\u3044\u305f\u3060\u304d\u3001\u3042\u308a\u304c\u3068\u3046\u3054\u3056\u3044\u307e\u3059\u3002\u307e\u305a\u3001\u5fa1\u793e\u306e\u30e9\u30dc\u3068\u696d\u52d9\u5185\u5bb9\u306b\u3064\u3044\u3066\u6559\u3048\u3066\u3044\u305f\u3060\u3051\u307e\u3059\u304b\u3002 AZAlexander \u3082\u3061\u308d\u3093\u3067\u3059\u3002\u79c1\u306f\u30c9\u30a4\u30c4\u306e Eurofins Dr. Specht \u3067 Managing Director \u3092\u52d9\u3081\u3066\u3044\u307e\u3059\u3002\u5f53\u793e\u306f\u3001\u8907\u6570\u6b8b\u7559\u8fb2\u85ac\u306e\u4e00\u6589\u5206\u6790\u3092\u5c02\u9580\u3068\u3059\u308b\u3001\u9ad8\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u5bfe\u5fdc\u306e\u8a8d\u5b9a\u5951\u7d04\u8a66\u9a13\u6a5f\u95a2\u3067\u3059\u3002\u593e\u96d1\u7269\u306e\u591a\u3044\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u304b\u3089\u62bd\u51fa\u3057\u305f QuEChERS \u62bd\u51fa\u6db2\u3092\u3001\u6bce\u9031\u6570\u767e\u4ef6\u306e\u30da\u30fc\u30b9\u3067\u30bf\u30a4\u30c8\u306a\u7d0d\u671f\u306e\u306a\u304b\u5206\u6790\u3057\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u88c5\u7f6e\u306e\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u306f\u8a31\u3055\u308c\u307e\u305b\u3093\u3002 \u79c1\u306f\u3001\u6761\u4ef6\u3092\u6574\u3048\u305f\u30c7\u30e2\u30f3\u30b9\u30c8\u30ec\u30fc\u30b7\u30e7\u30f3\u3060\u3051\u3067\u306a\u304f\u3001\u5b9f\u969b\u306e\u73fe\u5834\u3067\u6a5f\u80fd\u3059\u308b\u6280\u8853\u3092\u6c42\u3081\u3066\u3044\u307e\u3059\u3002\u65b0\u3057\u3044 GC \u30ab\u30e9\u30e0\u3092\u8a55\u4fa1\u3059\u308b\u969b\u3001\u5e38\u306b\u554f\u308f\u308c\u308b\u306e\u306f\u300c\u5b9f\u969b\u306e\u5206\u6790\u6761\u4ef6\u4e0b\u3067\u6027\u80fd\u3092\u7dad\u6301\u3067\u304d\u308b\u304b\u300d\u3068\u3044\u3046\u70b9\u3067\u3059\u3002 LSLaura Dr. Zahm \u304c\u30e9\u30dc\u904b\u55b6\u306e\u8996\u70b9\u3092\u62c5\u3046\u4e00\u65b9\u3067\u3001\u79c1\u306f\u30d9\u30f3\u30c1\u30ef\u30fc\u30af\u3092\u62c5\u5f53\u3057\u3066\u3044\u307e\u3059\u3002\u5177\u4f53\u7684\u306b\u306f\u3001\u5b9f\u9a13\u306e\u8a2d\u8a08\u3068\u5b9f\u65bd\u3001\u30c7\u30fc\u30bf\u89e3\u6790\u3001\u305d\u3057\u3066\u305d\u308c\u3089\u304c\u65e5\u5e38\u306e\u6b8b\u7559\u8fb2\u85ac\u5206\u6790\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306b\u3069\u306e\u3088\u3046\u306a\u610f\u5473\u3092\u6301\u3064\u306e\u304b\u3092\u691c\u8a0e\u3059\u308b\u5f79\u5272\u3067\u3059\u3002\u79c1\u306e\u4ed5\u4e8b\u306f\u3001GC \u30ab\u30e9\u30e0\u6280\u8853\u304c\u7ba1\u7406\u3055\u308c\u305f\u6761\u4ef6\u4e0b\u3067\u793a\u3059\u6027\u80fd\u3068\u3001\u5b9f\u969b\u306e\u30e9\u30dc\u306e\u53b3\u3057\u3044\u6761\u4ef6\u4e0b\u3067\u767a\u63ee\u3055\u308c\u308b\u6027\u80fd\u3068\u306e\u30ae\u30e3\u30c3\u30d7\u3092\u57cb\u3081\u308b\u3053\u3068\u306b\u3042\u308a\u307e\u3059\u3002 \u696d\u754c\u304c\u62b1\u3048\u308b\u8ab2\u984c RDRamkumar \u304a\u4e8c\u4eba\u306f\u98df\u54c1\u5b89\u5168\u6027\u8a66\u9a13\u306e\u6700\u524d\u7dda\u306b\u3044\u3089\u3063\u3057\u3083\u3044\u307e\u3059\u3002\u73fe\u5728\u3001\u6b8b\u7559\u8fb2\u85ac\u5206\u6790\u306b\u304a\u3044\u3066\u6700\u3082\u5927\u304d\u306a\u5206\u6790\u4e0a\u306e\u8ab2\u984c\u306f\u4f55\u3067\u3057\u3087\u3046\u304b\u3002 AZAlexander \u6700\u3082\u6839\u672c\u7684\u306a\u8ab2\u984c\u306f\u3001\u691c\u51fa\u5bfe\u8c61\u306e\u7bc4\u56f2\u304c\u5e83\u3044\u3053\u3068\u3067\u3059\u3002\u73fe\u5728\u306e\u7d71\u5408\u6b8b\u7559\u8fb2\u85ac\u5206\u6790\u6cd5\u306f\u3001\u6975\u6027\u5316\u5408\u7269\u3001\u7121\u6975\u6027\u5316\u5408\u7269\u3001\u9178\u6027\u5316\u5408\u7269\u3001\u5869\u57fa\u6027\u5316\u5408\u7269\u3001\u4e2d\u6027\u5316\u5408\u7269\u3092\u542b\u3080700\u6210\u5206\u4ee5\u4e0a\u3092\u5bfe\u8c61\u3068\u3057\u3001\u3053\u308c\u3089\u3059\u3079\u3066\u30921\u56de\u306e\u5206\u6790\u3067\u6e2c\u5b9a\u3057\u307e\u3059\u3002GC\u5206\u6790\u306b\u9650\u3063\u3066\u3082\u3001\u5f53\u30e9\u30dc\u3067\u306f1\u30b7\u30fc\u30b1\u30f3\u30b9\u3042\u305f\u308a300\u6210\u5206\u3092\u8d85\u3048\u308b\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u6271\u3063\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u5316\u5408\u7269\u306e\u591a\u69d8\u6027\u306f\u3001\u5358\u4e00\u306eGC\u30ab\u30e9\u30e0\u306e\u5316\u5b66\u7684\u6027\u8cea\u3060\u3051\u3067\u306f\u5bfe\u5fdc\u3057\u304d\u308c\u306a\u3044\u307b\u3069\u904e\u9177\u3067\u3059\u3002 \u52a0\u3048\u3066\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u7531\u6765\u306e\u6c5a\u67d3\u3082\u5927\u304d\u306a\u61f8\u5ff5\u4e8b\u9805\u3067\u3059\u3002\u6c5a\u67d3\u306b\u3088\u3063\u3066\u6027\u80fd\u57fa\u6e96\u3092\u6e80\u305f\u305b\u306a\u304f\u306a\u308b\u3068\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u305f\u3081\u306e\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u304c\u767a\u751f\u3057\u3001\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u304c\u5b8c\u5168\u306b\u505c\u6b62\u3057\u3066\u3057\u307e\u3044\u307e\u3059\u3002\u6700\u65b0\u306eGC-MS\/MS\u88c5\u7f6e\u3067\u306f\u3001\u691c\u51fa\u611f\u5ea6\u306f\u3082\u306f\u3084\u4e3b\u8981\u306a\u61f8\u5ff5\u4e8b\u9805\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u65e5\u5e38\u306e\u6b8b\u7559\u8fb2\u85ac\u5206\u6790\u3067\u4eca\u3001\u672c\u5f53\u306e\u30dc\u30c8\u30eb\u30cd\u30c3\u30af\u3068\u306a\u3063\u3066\u3044\u308b\u306e\u306f\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u8010\u6027\u3067\u3059\u3002 LSLaura \u904b\u7528\u9762\u306e\u8ab2\u984c\u3082\u4ed8\u3051\u52a0\u3048\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002\u5834\u5408\u306b\u3088\u3063\u3066\u306f\u3001\u6570\u6642\u9593\u4ee5\u5185\u3067\u306e\u7d50\u679c\u5831\u544a\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002\u88c5\u7f6e\u306e\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u306f\u6c7a\u3057\u3066\u8a31\u5bb9\u3055\u308c\u307e\u305b\u3093\u3002\u305d\u306e\u305f\u3081\u3001\u30ab\u30e9\u30e0\u304c\u60f3\u5b9a\u3088\u308a\u65e9\u304f\u52a3\u5316\u3057\u305f\u308a\u300180\u56de\u306e\u6ce8\u5165\u5f8c\u306b\u56de\u53ce\u7387\u304c\u8a31\u5bb9\u57fa\u6e96\u304b\u3089\u5916\u308c\u305f\u308a\u3059\u308b\u3068\u3001\u5358\u306a\u308b\u79d1\u5b66\u7684\u306a\u554f\u984c\u3067\u306f\u6e08\u307e\u306a\u304f\u306a\u308a\u307e\u3059\u3002\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb\u4e0a\u306e\u5371\u6a5f\u306b\u3064\u306a\u304c\u308b\u306e\u3067\u3059\u3002\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u60aa\u5316\u3084\u56de\u53ce\u7387\u306e\u4f4e\u4e0b\u306b\u3088\u308b\u518d\u5206\u6790\u306f\u3001\u305d\u306e\u305f\u3073\u306b\u8cb4\u91cd\u306a\u6642\u9593\u3092\u596a\u3044\u307e\u3059\u3002 RDRamkumar \u5927\u5909\u8208\u5473\u6df1\u3044\u3067\u3059\u306d\u3002\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u8010\u6027\u304c\u306a\u305c\u3053\u308c\u307b\u3069\u5927\u304d\u306a\u554f\u984c\u3068\u306a\u308b\u306e\u304b\u3001\u8a73\u3057\u304f\u4f3a\u3048\u307e\u3059\u304b\u3002\u6700\u65b0\u306eGC-MS\/MS\u88c5\u7f6e\u306f\u6975\u3081\u3066\u9ad8\u3044\u691c\u51fa\u611f\u5ea6\u3092\u5099\u3048\u3066\u3044\u307e\u3059\u304c\u3001\u3069\u3053\u306b\u554f\u984c\u304c\u751f\u3058\u308b\u306e\u3067\u3057\u3087\u3046\u304b\u3002&#8230;<\/p>\n","protected":false},"author":73,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[2738],"industries-application":[2169,2167],"post-badge":[],"resource-type":[],"product-library":[2384,2372],"resource-technique":[],"ppma_author":[414],"class_list":["post-102489","post","type-post","status-publish","format-standard","hentry","category-blogs","tag-rmx-resources","industries-application-food-safety","industries-application-food-beverage","product-library-gc-columns","product-library-gas-chromatography-products"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}],"post_tag":[{"value":2738,"label":"RMX Resources"}],"industries-application":[{"value":2169,"label":"Food Safety"},{"value":2167,"label":"Food &amp; Beverage"}],"product-library":[{"value":2384,"label":"GC Columns"},{"value":2372,"label":"Gas Chromatography Products"}]},"featured_image_src_large":false,"author_info":{"display_name":"Ayumi Suzuki","author_link":"https:\/\/discover.restek.com\/ja\/author\/ayumi-suzuki\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":9,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":[{"term_id":2738,"name":"RMX Resources","slug":"rmx-resources","term_group":0,"term_taxonomy_id":2738,"taxonomy":"post_tag","description":"Explore RMX Resources Now","parent":0,"count":23,"filter":"raw"}],"authors":[{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/102489","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/73"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=102489"}],"version-history":[{"count":60,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/102489\/revisions"}],"predecessor-version":[{"id":104949,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/102489\/revisions\/104949"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=102489"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=102489"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=102489"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=102489"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=102489"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=102489"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=102489"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=102489"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=102489"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}