{"id":105532,"date":"2021-09-12T14:30:00","date_gmt":"2021-09-12T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=105532"},"modified":"2026-11-13T00:45:54","modified_gmt":"2026-11-13T00:45:54","slug":"chiral-blog-3-overloading-and-tailing","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4620-ja\/chiral-blog-3-overloading-and-tailing","title":{"rendered":"GC\u30ad\u30e9\u30eb\u5206\u6790 3\uff1a\u30ad\u30e9\u30eb\u30ab\u30e9\u30e0\u306e\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u3068\u30c6\u30fc\u30ea\u30f3\u30b0"},"content":{"rendered":"\n<style data-wp-block-html=\"css\">\n<style>\n.rtk-article { line-height: 1.8; font-size: 16px; }\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n.rtk-article h2 {\n  margin-top: 5em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n.rtk-article h3 {\n  margin-top: 3em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n.rtk-article p {\n  font-size: 18px;\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n.rtk-article a {\n  font-size: inherit !important;\n}\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n.rtk-article .rtk-lead {\n  font-size: 18px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n.rtk-article blockquote.rtk-voc {\n  position: relative;\n  border-left: 4px solid #00265d;\n  background: #f7f8f9;\n  padding: 18px 22px 18px 30px;\n  margin: 2em 0;\n  font-style: italic;\n  color: #333;\n}\n.rtk-article blockquote.rtk-voc p { margin-bottom: 0.4em; }\n.rtk-article blockquote.rtk-voc cite {\n  display: block;\n  font-style: normal;\n  font-size: 13px;\n  color: #4a4a4a;\n}\n.rtk-article .rtk-coa-list {\n  list-style: none;\n  padding: 0;\n}\n.rtk-article .rtk-coa-list li {\n  background: #fafbfc;\n  border: 1px solid #e1e8ec;\n  border-radius: 6px;\n  padding: 14px 18px;\n  margin-bottom: 12px;\n}\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n\/* ===== v3 \u8ffd\u52a0\uff1a\u82f1\u8a9e\u7248\u306e\u898b\u3048\u65b9\u306b\u5408\u308f\u305b\u305f\u30b3\u30f3\u30dd\u30fc\u30cd\u30f3\u30c8 ===== *\/\n\n\/* \u756a\u53f7\u4ed8\u304d\u30b9\u30c6\u30c3\u30d7\u898b\u51fa\u3057\uff08\u82f1\u8a9e\u7248\u306e\u300c01 | \u898b\u51fa\u3057\u300d\u8868\u793a\uff09 *\/\n.rtk-article h3.rtk-step {\n  display: flex;\n  align-items: baseline;\n  padding-left: 0;\n  border-left: none;\n}\n.rtk-article .rtk-step-num {\n  flex-shrink: 0;\n  font-weight: 700;\n  font-size: 1.25em;\n  line-height: 1.1;\n  color: #0d7bc4;\n  padding-right: 0.55em;\n  margin-right: 0.55em;\n  border-right: 2px solid #cde3f2;\n  font-variant-numeric: tabular-nums;\n}\n\n\/* \u811a\u6ce8\u30fb\u6ce8\u8a18\uff08*NIST \u7b49\uff09 *\/\n.rtk-article .rtk-note {\n  font-size: 14px;\n  color: #4a4a4a;\n}\n\n\/* \u8a3c\u660e\u66f8\u30ab\u30fc\u30c9\u5185\u306e\u898b\u51fa\u3057\u3092\u6539\u884c\u3057\u3066\u5f37\u8abf *\/\n.rtk-article .rtk-coa-list li strong {\n  display: block;\n  margin-bottom: 0.3em;\n  color: #00265d;\n}\n\n\/* \u30bb\u30af\u30b7\u30e7\u30f3\u672b\u5c3e\u306e\u30dc\u30bf\u30f3\u578bCTA *\/\n.rtk-article .rtk-cta-links {\n  display: flex;\n  flex-wrap: wrap;\n  gap: 12px;\n  margin: 2em 0 1em;\n}\n.rtk-article a.rtk-button {\n  display: inline-block;\n  padding: 12px 22px;\n  border-radius: 6px;\n  background: #0d7bc4;\n  border: 2px solid #0d7bc4;\n  color: #fff;\n  font-weight: 700;\n  text-decoration: none;\n  line-height: 1.4;\n}\n.rtk-article a.rtk-button:hover {\n  background: #00265d;\n  border-color: #00265d;\n}\n.rtk-article a.rtk-button--ghost {\n  background: #fff;\n  color: #0d7bc4;\n}\n.rtk-article a.rtk-button--ghost:hover {\n  background: #eef6fc;\n  border-color: #0d7bc4;\n}\n\n\/* \u8a18\u4e8b\u672b\u5c3e\u306e\u76f8\u8ac7\u30dc\u30c3\u30af\u30b9\uff08\u82f1\u8a9e\u7248\u306e Need Help \u76f8\u5f53\uff09 *\/\n.rtk-article .rtk-help {\n  background: #00265d;\n  color: #fff;\n  border-radius: 6px;\n  padding: 24px 26px;\n  margin: 3em 0 1em;\n}\n.rtk-article .rtk-help p { color: #fff; }\n.rtk-article .rtk-help .rtk-help-title {\n  font-size: 20px;\n  font-weight: 700;\n  margin-bottom: 0.4em;\n}\n.rtk-article .rtk-help a.rtk-button {\n  background: #fff;\n  border-color: #fff;\n  color: #00265d;\n  margin-top: 0.6em;\n}\n.rtk-article .rtk-help a.rtk-button:hover {\n  background: #eef6fc;\n  border-color: #eef6fc;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 3.5em; }\n  .rtk-article h3 { margin-top: 2.2em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout,\n  .rtk-article blockquote.rtk-voc {\n    padding: 14px 16px;\n  }\n  .rtk-article .rtk-cta-links { flex-direction: column; }\n  .rtk-article a.rtk-button { display: block; text-align: center; }\n  .rtk-article .rtk-help { padding: 18px 16px; }\n}\n<\/style>\n\n<div class=\"rtk-article\">\n<div class=\"rtk-intro\">\n<p class=\"rtk-lead\">\u30ad\u30e9\u30eb\u5316\u5408\u7269\u306e\u4e2d\u306b\u306f\u3001\u30a2\u30ad\u30e9\u30eb\u5316\u5408\u7269\u3088\u308a\u4f4e\u3044\u6fc3\u5ea6\u3067\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u3092\u8d77\u3053\u3059\u3082\u306e\u304c\u3042\u308a\u307e\u3059\u3002\u30ad\u30e9\u30eb\u30ab\u30e9\u30e0\u306e\u56fa\u5b9a\u76f8\u306f\u3001\u56fa\u5b9a\u76f8\u30dd\u30ea\u30de\u30fc\u306b\u30b7\u30af\u30ed\u30c7\u30ad\u30b9\u30c8\u30ea\u30f3\u3092\u6dfb\u52a0\u3057\u305f\u3082\u306e\u3067\u3001\u305d\u306e\u542b\u6709\u91cf\u306f\u30ab\u30e9\u30e0\u306b\u3088\u3063\u30665\uff5e50%\u3067\u3059\u3002\u30ad\u30e9\u30eb\u5316\u5408\u7269\u304c\u76f8\u4e92\u4f5c\u7528\u3067\u304d\u308b\u306e\u306f\u3001\u3053\u306e\u30b7\u30af\u30ed\u30c7\u30ad\u30b9\u30c8\u30ea\u30f3\u306e\u90e8\u5206\u306b\u9650\u3089\u308c\u307e\u3059\u3002\u3053\u308c\u304c\u3001\u4f4e\u3044\u6fc3\u5ea6\u3067\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u304c\u8d77\u304d\u308b\u4e00\u56e0\u3067\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u30ad\u30e9\u30eb\u5316\u5408\u7269\u3067\u306f\u3001\u30ab\u30e9\u30e0\u5168\u4f53\u306e\u8ca0\u8377\u5bb9\u91cf\u306b\u9054\u3057\u3066\u3044\u306a\u304f\u3066\u3082\u3001\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u306b\u3088\u3063\u3066\u93e1\u50cf\u7570\u6027\u4f53\u304c\u5206\u96e2\u3057\u306b\u304f\u304f\u306a\u308a\u307e\u3059\u3002\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u6642\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u306b\u3082\u9055\u3044\u304c\u3042\u308a\u307e\u3059\u3002\u901a\u5e38\u306e\u56fa\u5b9a\u76f8\u3067\u306f\u30d5\u30ed\u30f3\u30c6\u30a3\u30f3\u30b0\u30d4\u30fc\u30af\u306b\u306a\u308a\u307e\u3059\u304c\u3001\u30b7\u30af\u30ed\u30c7\u30ad\u30b9\u30c8\u30ea\u30f3\u56fa\u5b9a\u76f8\u3067\u306f\u30c6\u30fc\u30ea\u30f3\u30b0\u30d4\u30fc\u30af\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<\/div>\n\n<div style=\"margin-top: 5em;\"><\/div>\n\n<h2>Rt-\u03b2DEXsp\u3067\u306e\u30ea\u30ca\u30ed\u30fc\u30eb\u306e\u4f8b\uff5c\u30ab\u30e9\u30e0\u5c0e\u5165\u91cf200 ng\u304b\u3089\u30c6\u30fc\u30ea\u30f3\u30b0\u304c\u767a\u751f<\/h2>\n\n<p>1\u3064\u76ee\u306e\u4f8b\u306f\u3001Rt-\u03b2DEXsp\u3067\u306e\u30ea\u30ca\u30ed\u30fc\u30eb\u306e\u5206\u96e2\u3067\u3059\u3002<strong>Figure 1<\/strong>\u306b\u3001\u30ab\u30e9\u30e0\u5c0e\u5165\u91cf\u3092\u5909\u3048\u305f\u3068\u304d\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u3001\u93e1\u50cf\u7570\u6027\u4f53\u30d4\u30fc\u30af\u9593\u306e\u5206\u96e2\u306e\u7a0b\u5ea6\u3092\u793a\u3059Rs\u5024\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n\n<ul>\n<li><strong>A\uff0920 ng\uff1a<\/strong>Rs 1.82\u3002\u30d4\u30fc\u30af\u306f\u30b7\u30e3\u30fc\u30d7\u3067\u3001\u93e1\u50cf\u7570\u6027\u4f53\u304c\u826f\u597d\u306b\u5206\u96e2\u3057\u3066\u3044\u307e\u3059\u3002<\/li>\n<li><strong>B\uff09200 ng\uff1a<\/strong>Rs 1.62\u3002\u30d4\u30fc\u30af\u306b\u30c6\u30fc\u30ea\u30f3\u30b0\u304c\u73fe\u308c\u59cb\u3081\u3001\u5206\u96e2\u304c\u308f\u305a\u304b\u306b\u60aa\u304f\u306a\u3063\u3066\u3044\u307e\u3059\u3002<\/li>\n<li><strong>C\uff092 \u00b5g\uff1a<\/strong>Rs 1.46\u3002\u9855\u8457\u306a\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u306b\u3088\u308a\u8457\u3057\u3044\u30c6\u30fc\u30ea\u30f3\u30b0\u304c\u751f\u3058\u3001\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u5206\u96e2\u304c\u5931\u308f\u308c\u3066\u3044\u307e\u3059\u3002<\/li>\n<\/ul>\n\n<p>\u5185\u5f840.32 mm\u306e\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u3067\u306f\u3001\u6700\u5927\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u5bb9\u91cf\u306f\u901a\u5e381\u6210\u5206\u3042\u305f\u308a400\uff5e500 ng\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u30ad\u30e9\u30eb\u5316\u5408\u7269\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u304b\u3089\u306f\u3001\u305d\u306e\u7d043\u5206\u306e1\u306e\u91cf\u3067\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u304c\u751f\u3058\u3066\u3044\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002\u3053\u3053\u3067\u3082\u3001\u901a\u5e38\u306e\u30ab\u30e9\u30e0\u3068\u6bd4\u3079\u3066\u3001\u30ad\u30e9\u30eb\u5316\u5408\u7269\u3068\u76f8\u4e92\u4f5c\u7528\u3067\u304d\u308b\u30b7\u30af\u30ed\u30c7\u30ad\u30b9\u30c8\u30ea\u30f3\u306e\u91cf\u304c\u306f\u308b\u304b\u306b\u5c11\u306a\u3044\u3053\u3068\u304c\u8981\u56e0\u3067\u3059\u3002<\/p><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-chiral-blog-3-overloading-and-tailing-01.png\" alt=\"decorative\" title=\"-\"><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\"><strong>Figure 1\uff1a<\/strong>Rt-\u03b2DEXsp\u306b\u304a\u3051\u308b\u30ea\u30ca\u30ed\u30fc\u30eb\u306e\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\uff08A\u30fbB\u306f\u62e1\u5927\u8868\u793a\uff09<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<style data-wp-block-html=\"css\">\n<style>\n.rtk-article { line-height: 1.8; font-size: 16px; }\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n.rtk-article h2 {\n  margin-top: 5em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n.rtk-article h3 {\n  margin-top: 3em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n.rtk-article p {\n  font-size: 18px;\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n.rtk-article a {\n  font-size: inherit !important;\n}\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n.rtk-article .rtk-lead {\n  font-size: 18px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n.rtk-article blockquote.rtk-voc {\n  position: relative;\n  border-left: 4px solid #00265d;\n  background: #f7f8f9;\n  padding: 18px 22px 18px 30px;\n  margin: 2em 0;\n  font-style: italic;\n  color: #333;\n}\n.rtk-article blockquote.rtk-voc p { margin-bottom: 0.4em; }\n.rtk-article blockquote.rtk-voc cite {\n  display: block;\n  font-style: normal;\n  font-size: 13px;\n  color: #4a4a4a;\n}\n.rtk-article .rtk-coa-list {\n  list-style: none;\n  padding: 0;\n}\n.rtk-article .rtk-coa-list li {\n  background: #fafbfc;\n  border: 1px solid #e1e8ec;\n  border-radius: 6px;\n  padding: 14px 18px;\n  margin-bottom: 12px;\n}\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n\/* ===== v3 \u8ffd\u52a0\uff1a\u82f1\u8a9e\u7248\u306e\u898b\u3048\u65b9\u306b\u5408\u308f\u305b\u305f\u30b3\u30f3\u30dd\u30fc\u30cd\u30f3\u30c8 ===== *\/\n\n\/* \u756a\u53f7\u4ed8\u304d\u30b9\u30c6\u30c3\u30d7\u898b\u51fa\u3057\uff08\u82f1\u8a9e\u7248\u306e\u300c01 | \u898b\u51fa\u3057\u300d\u8868\u793a\uff09 *\/\n.rtk-article h3.rtk-step {\n  display: flex;\n  align-items: baseline;\n  padding-left: 0;\n  border-left: none;\n}\n.rtk-article .rtk-step-num {\n  flex-shrink: 0;\n  font-weight: 700;\n  font-size: 1.25em;\n  line-height: 1.1;\n  color: #0d7bc4;\n  padding-right: 0.55em;\n  margin-right: 0.55em;\n  border-right: 2px solid #cde3f2;\n  font-variant-numeric: tabular-nums;\n}\n\n\/* \u811a\u6ce8\u30fb\u6ce8\u8a18\uff08*NIST \u7b49\uff09 *\/\n.rtk-article .rtk-note {\n  font-size: 14px;\n  color: #4a4a4a;\n}\n\n\/* \u8a3c\u660e\u66f8\u30ab\u30fc\u30c9\u5185\u306e\u898b\u51fa\u3057\u3092\u6539\u884c\u3057\u3066\u5f37\u8abf *\/\n.rtk-article .rtk-coa-list li strong {\n  display: block;\n  margin-bottom: 0.3em;\n  color: #00265d;\n}\n\n\/* \u30bb\u30af\u30b7\u30e7\u30f3\u672b\u5c3e\u306e\u30dc\u30bf\u30f3\u578bCTA *\/\n.rtk-article .rtk-cta-links {\n  display: flex;\n  flex-wrap: wrap;\n  gap: 12px;\n  margin: 2em 0 1em;\n}\n.rtk-article a.rtk-button {\n  display: inline-block;\n  padding: 12px 22px;\n  border-radius: 6px;\n  background: #0d7bc4;\n  border: 2px solid #0d7bc4;\n  color: #fff;\n  font-weight: 700;\n  text-decoration: none;\n  line-height: 1.4;\n}\n.rtk-article a.rtk-button:hover {\n  background: #00265d;\n  border-color: #00265d;\n}\n.rtk-article a.rtk-button--ghost {\n  background: #fff;\n  color: #0d7bc4;\n}\n.rtk-article a.rtk-button--ghost:hover {\n  background: #eef6fc;\n  border-color: #0d7bc4;\n}\n\n\/* \u8a18\u4e8b\u672b\u5c3e\u306e\u76f8\u8ac7\u30dc\u30c3\u30af\u30b9\uff08\u82f1\u8a9e\u7248\u306e Need Help \u76f8\u5f53\uff09 *\/\n.rtk-article .rtk-help {\n  background: #00265d;\n  color: #fff;\n  border-radius: 6px;\n  padding: 24px 26px;\n  margin: 3em 0 1em;\n}\n.rtk-article .rtk-help p { color: #fff; }\n.rtk-article .rtk-help .rtk-help-title {\n  font-size: 20px;\n  font-weight: 700;\n  margin-bottom: 0.4em;\n}\n.rtk-article .rtk-help a.rtk-button {\n  background: #fff;\n  border-color: #fff;\n  color: #00265d;\n  margin-top: 0.6em;\n}\n.rtk-article .rtk-help a.rtk-button:hover {\n  background: #eef6fc;\n  border-color: #eef6fc;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 3.5em; }\n  .rtk-article h3 { margin-top: 2.2em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout,\n  .rtk-article blockquote.rtk-voc {\n    padding: 14px 16px;\n  }\n  .rtk-article .rtk-cta-links { flex-direction: column; }\n  .rtk-article a.rtk-button { display: block; text-align: center; }\n  .rtk-article .rtk-help { padding: 18px 16px; }\n}\n<\/style>\n\n<div class=\"rtk-article\">\n\n<div style=\"margin-top: 5em;\"><\/div>\n\n<h2>Rt-\u03b2DEXsm\u3067\u306e2,3-\u30d6\u30bf\u30f3\u30b8\u30aa\u30fc\u30eb\u306e\u4f8b\uff5c\u5206\u96e2\u304c\u826f\u597d\u306a\u5834\u5408\u306e\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9<\/h2>\n\n<p>2\u3064\u76ee\u306e\u4f8b\u306f\u3001Rt-\u03b2DEXsm\u3067\u306e2,3-\u30d6\u30bf\u30f3\u30b8\u30aa\u30fc\u30eb\u306e\u5206\u96e2\u3067\u3059\u3002<strong>Figure 2<\/strong>\u306b\u3001\u30ab\u30e9\u30e0\u5c0e\u5165\u91cf500 ng\u306825 ng\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u793a\u3057\u307e\u3059\u30022,3-\u30d6\u30bf\u30f3\u30b8\u30aa\u30fc\u30eb\u306b\u306f3\u7a2e\u306e\u7acb\u4f53\u7570\u6027\u4f53\uff081\u5bfe\u306e\u93e1\u50cf\u7570\u6027\u4f53\u3068\u30e1\u30bd\u4f53\uff09\u304c\u3042\u308a\u30013\u672c\u306e\u30d4\u30fc\u30af\u3068\u3057\u3066\u73fe\u308c\u307e\u3059\u3002<\/p>\n\n<ul>\n<li><strong>A\uff09500 ng\uff1a<\/strong>3\u672c\u306e\u30d4\u30fc\u30af\u3059\u3079\u3066\u306b\u30c6\u30fc\u30ea\u30f3\u30b0\u304c\u898b\u3089\u308c\u3001\u6eb6\u51fa\u3082\u308f\u305a\u304b\u306b\u65e9\u307e\u3063\u3066\u3044\u307e\u3059\u3002<\/li>\n<li><strong>B\uff0925 ng\uff1a<\/strong>\u30d4\u30fc\u30af\u306f\u30b7\u30e3\u30fc\u30d7\u3067\u3001\u30c6\u30fc\u30ea\u30f3\u30b0\u306f\u307b\u3068\u3093\u3069\u898b\u3089\u308c\u307e\u305b\u3093\u3002<\/li>\n<\/ul>\n\n<p>\u30ea\u30ca\u30ed\u30fc\u30eb\u306e\u4f8b\u3068\u540c\u69d8\u306b\u3001\u5c0e\u5165\u91cf\u304c\u591a\u3044\u3068\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u306b\u3088\u308b\u30c6\u30fc\u30ea\u30f3\u30b0\u304c\u751f\u3058\u307e\u3059\u3002\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u306e\u7a0b\u5ea6\u306f\u30ea\u30ca\u30ed\u30fc\u30eb\u306e\u4f8b\u3088\u308a\u5927\u304d\u3044\u3082\u306e\u306e\u3001\u3053\u306e\u5316\u5408\u7269\u3067\u306f\u7570\u6027\u4f53\u540c\u58eb\u304c\u5927\u304d\u304f\u96e2\u308c\u3066\u6eb6\u51fa\u3057\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001500 ng\u3067\u3082\u5404\u30d4\u30fc\u30af\u306f\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u307e\u3067\u5206\u96e2\u3057\u3066\u304a\u308a\u3001\u5206\u96e2\u306e\u60aa\u5316\u306f\u305d\u308c\u307b\u3069\u76ee\u7acb\u3061\u307e\u305b\u3093\u3002<\/p><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-chiral-blog-3-overloading-and-tailing-02.png\" alt=\"decorative\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\"><strong>Figure 2<\/strong>\uff1aRt-\u03b2DEXsm\u306b\u304a\u3051\u308b\u30d6\u30bf\u30f3\u30b8\u30aa\u30fc\u30eb\u306e\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<style data-wp-block-html=\"css\">\n<style>\n.rtk-article { line-height: 1.8; font-size: 16px; }\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n.rtk-article h2 {\n  margin-top: 5em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n.rtk-article h3 {\n  margin-top: 3em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n.rtk-article p {\n  font-size: 18px;\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n.rtk-article a {\n  font-size: inherit !important;\n}\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n.rtk-article .rtk-lead {\n  font-size: 18px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n.rtk-article blockquote.rtk-voc {\n  position: relative;\n  border-left: 4px solid #00265d;\n  background: #f7f8f9;\n  padding: 18px 22px 18px 30px;\n  margin: 2em 0;\n  font-style: italic;\n  color: #333;\n}\n.rtk-article blockquote.rtk-voc p { margin-bottom: 0.4em; }\n.rtk-article blockquote.rtk-voc cite {\n  display: block;\n  font-style: normal;\n  font-size: 13px;\n  color: #4a4a4a;\n}\n.rtk-article .rtk-coa-list {\n  list-style: none;\n  padding: 0;\n}\n.rtk-article .rtk-coa-list li {\n  background: #fafbfc;\n  border: 1px solid #e1e8ec;\n  border-radius: 6px;\n  padding: 14px 18px;\n  margin-bottom: 12px;\n}\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n\/* ===== v3 \u8ffd\u52a0\uff1a\u82f1\u8a9e\u7248\u306e\u898b\u3048\u65b9\u306b\u5408\u308f\u305b\u305f\u30b3\u30f3\u30dd\u30fc\u30cd\u30f3\u30c8 ===== *\/\n\n\/* \u756a\u53f7\u4ed8\u304d\u30b9\u30c6\u30c3\u30d7\u898b\u51fa\u3057\uff08\u82f1\u8a9e\u7248\u306e\u300c01 | \u898b\u51fa\u3057\u300d\u8868\u793a\uff09 *\/\n.rtk-article h3.rtk-step {\n  display: flex;\n  align-items: baseline;\n  padding-left: 0;\n  border-left: none;\n}\n.rtk-article .rtk-step-num {\n  flex-shrink: 0;\n  font-weight: 700;\n  font-size: 1.25em;\n  line-height: 1.1;\n  color: #0d7bc4;\n  padding-right: 0.55em;\n  margin-right: 0.55em;\n  border-right: 2px solid #cde3f2;\n  font-variant-numeric: tabular-nums;\n}\n\n\/* \u811a\u6ce8\u30fb\u6ce8\u8a18\uff08*NIST \u7b49\uff09 *\/\n.rtk-article .rtk-note {\n  font-size: 14px;\n  color: #4a4a4a;\n}\n\n\/* \u8a3c\u660e\u66f8\u30ab\u30fc\u30c9\u5185\u306e\u898b\u51fa\u3057\u3092\u6539\u884c\u3057\u3066\u5f37\u8abf *\/\n.rtk-article .rtk-coa-list li strong {\n  display: block;\n  margin-bottom: 0.3em;\n  color: #00265d;\n}\n\n\/* \u30bb\u30af\u30b7\u30e7\u30f3\u672b\u5c3e\u306e\u30dc\u30bf\u30f3\u578bCTA *\/\n.rtk-article .rtk-cta-links {\n  display: flex;\n  flex-wrap: wrap;\n  gap: 12px;\n  margin: 2em 0 1em;\n}\n.rtk-article a.rtk-button {\n  display: inline-block;\n  padding: 12px 22px;\n  border-radius: 6px;\n  background: #0d7bc4;\n  border: 2px solid #0d7bc4;\n  color: #fff;\n  font-weight: 700;\n  text-decoration: none;\n  line-height: 1.4;\n}\n.rtk-article a.rtk-button:hover {\n  background: #00265d;\n  border-color: #00265d;\n}\n.rtk-article a.rtk-button--ghost {\n  background: #fff;\n  color: #0d7bc4;\n}\n.rtk-article a.rtk-button--ghost:hover {\n  background: #eef6fc;\n  border-color: #0d7bc4;\n}\n\n\/* \u8a18\u4e8b\u672b\u5c3e\u306e\u76f8\u8ac7\u30dc\u30c3\u30af\u30b9\uff08\u82f1\u8a9e\u7248\u306e Need Help \u76f8\u5f53\uff09 *\/\n.rtk-article .rtk-help {\n  background: #00265d;\n  color: #fff;\n  border-radius: 6px;\n  padding: 24px 26px;\n  margin: 3em 0 1em;\n}\n.rtk-article .rtk-help p { color: #fff; }\n.rtk-article .rtk-help .rtk-help-title {\n  font-size: 20px;\n  font-weight: 700;\n  margin-bottom: 0.4em;\n}\n.rtk-article .rtk-help a.rtk-button {\n  background: #fff;\n  border-color: #fff;\n  color: #00265d;\n  margin-top: 0.6em;\n}\n.rtk-article .rtk-help a.rtk-button:hover {\n  background: #eef6fc;\n  border-color: #eef6fc;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 3.5em; }\n  .rtk-article h3 { margin-top: 2.2em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout,\n  .rtk-article blockquote.rtk-voc {\n    padding: 14px 16px;\n  }\n  .rtk-article .rtk-cta-links { flex-direction: column; }\n  .rtk-article a.rtk-button { display: block; text-align: center; }\n  .rtk-article .rtk-help { padding: 18px 16px; }\n}\n<\/style>\n\n<div class=\"rtk-article\">\n<h2>\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n\n<details class=\"rtk-faq\">\n<summary><h3>\u30ad\u30e9\u30eb\u30ab\u30e9\u30e0\u3067\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u3059\u308b\u3068\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u306f\u3069\u3046\u306a\u308a\u307e\u3059\u304b\uff1f<\/h3><\/summary>\n<p>\u901a\u5e38\u306e\u56fa\u5b9a\u76f8\u3067\u306f\u30d5\u30ed\u30f3\u30c6\u30a3\u30f3\u30b0\u30d4\u30fc\u30af\u306b\u306a\u308a\u307e\u3059\u304c\u3001\u30b7\u30af\u30ed\u30c7\u30ad\u30b9\u30c8\u30ea\u30f3\u56fa\u5b9a\u76f8\u3067\u306f\u30c6\u30fc\u30ea\u30f3\u30b0\u30d4\u30fc\u30af\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<\/details>\n\n<details class=\"rtk-faq\">\n<summary><h3>\u30ad\u30e9\u30eb\u30ab\u30e9\u30e0\u3067\u306f\u3001\u3069\u306e\u304f\u3089\u3044\u306e\u91cf\u304b\u3089\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u304c\u8d77\u304d\u307e\u3059\u304b\uff1f<\/h3><\/summary>\n<p>\u5185\u5f840.32 mm\u306e\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306e\u8ca0\u8377\u5bb9\u91cf\u306f\u901a\u5e381\u6210\u5206\u3042\u305f\u308a400\uff5e500 ng\u3067\u3059\u304c\u3001\u30ad\u30e9\u30eb\u5316\u5408\u7269\u3067\u306f\u305d\u306e\u7d043\u5206\u306e1\u306e\u91cf\u3067\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u304c\u751f\u3058\u307e\u3059\u3002Rt-\u03b2DEXsp\u3067\u306e\u30ea\u30ca\u30ed\u30fc\u30eb\u306e\u4f8b\u3067\u306f\u3001200 ng\u3067\u30c6\u30fc\u30ea\u30f3\u30b0\u304c\u73fe\u308c\u59cb\u3081\u307e\u3057\u305f\u3002<\/p>\n<\/details>\n\n<h2>\u307e\u3068\u3081<\/h2>\n\n<p>\u30b7\u30af\u30ed\u30c7\u30ad\u30b9\u30c8\u30ea\u30f3\u56fa\u5b9a\u76f8\u3067\u306f\u3001\u30ad\u30e9\u30eb\u5316\u5408\u7269\u3068\u76f8\u4e92\u4f5c\u7528\u3067\u304d\u308b\u30b7\u30af\u30ed\u30c7\u30ad\u30b9\u30c8\u30ea\u30f3\u306e\u91cf\u304c\u9650\u3089\u308c\u308b\u305f\u3081\u3001\u901a\u5e38\u306e\u30ab\u30e9\u30e0\u3088\u308a\u5c11\u306a\u3044\u5c0e\u5165\u91cf\u3067\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u304c\u8d77\u3053\u308a\u3001\u30c6\u30fc\u30ea\u30f3\u30b0\u304c\u751f\u3058\u307e\u3059\u3002\u826f\u597d\u306a\u30ad\u30e9\u30eb\u5206\u96e2\u3092\u5f97\u308b\u306b\u306f\u3001\u30ab\u30e9\u30e0\u5c0e\u5165\u91cf\u3092\u6291\u3048\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002<\/p>\n\n<div class=\"rtk-callout\">\n<p>\u6b21\u56de\u304b\u3089\u306f\u3001\u500b\u3005\u306e\u30ab\u30e9\u30e0\u3068\u5177\u4f53\u7684\u306a\u5206\u96e2\u4f8b\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u307e\u305a\u306fRt-\u03b2DEXm\u3001Rt-\u03b2DEXsm\u3001Rt-\u03b2DEXse\u3092\u53d6\u308a\u4e0a\u3052\u307e\u3059\u3002<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4621-ja\/chiral-separation-4-separation-with-rt-dexm-rt-dexsm-and-rt-dexse\">GC\u30ad\u30e9\u30eb\u5206\u67904\uff1aRt-\u03b2DEXm\u3001Rt-\u03b2DEXsm\u3001Rt-\u03b2DEXse\u306b\u3088\u308b\u5206\u96e2<\/a>\u3092\u8aad\u3080<\/p>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u30ad\u30e9\u30eb\u5316\u5408\u7269\u306e\u4e2d\u306b\u306f\u3001\u30a2\u30ad\u30e9\u30eb\u5316\u5408\u7269\u3088\u308a\u4f4e\u3044\u6fc3\u5ea6\u3067\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u3092\u8d77\u3053\u3059\u3082\u306e\u304c\u3042\u308a\u307e\u3059\u3002\u30ad\u30e9\u30eb\u30ab\u30e9\u30e0\u306e\u56fa\u5b9a\u76f8\u306f\u3001\u56fa\u5b9a\u76f8\u30dd\u30ea\u30de\u30fc\u306b\u30b7\u30af\u30ed\u30c7\u30ad\u30b9\u30c8\u30ea\u30f3\u3092\u6dfb\u52a0\u3057\u305f\u3082\u306e\u3067\u3001\u305d\u306e\u542b\u6709\u91cf\u306f\u30ab\u30e9\u30e0\u306b\u3088\u3063\u30665\uff5e50%\u3067\u3059\u3002\u30ad\u30e9\u30eb\u5316\u5408\u7269\u304c\u76f8\u4e92\u4f5c\u7528\u3067\u304d\u308b\u306e\u306f\u3001\u3053\u306e\u30b7\u30af\u30ed\u30c7\u30ad\u30b9\u30c8\u30ea\u30f3\u306e\u90e8\u5206\u306b\u9650\u3089\u308c\u307e\u3059\u3002\u3053\u308c\u304c\u3001\u4f4e\u3044\u6fc3\u5ea6\u3067\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u304c\u8d77\u304d\u308b\u4e00\u56e0\u3067\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u30ad\u30e9\u30eb\u5316\u5408\u7269\u3067\u306f\u3001\u30ab\u30e9\u30e0\u5168\u4f53\u306e\u8ca0\u8377\u5bb9\u91cf\u306b\u9054\u3057\u3066\u3044\u306a\u304f\u3066\u3082\u3001\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u306b\u3088\u3063\u3066\u93e1\u50cf\u7570\u6027\u4f53\u304c\u5206\u96e2\u3057\u306b\u304f\u304f\u306a\u308a\u307e\u3059\u3002\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u6642\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u306b\u3082\u9055\u3044\u304c\u3042\u308a\u307e\u3059\u3002\u901a\u5e38\u306e\u56fa\u5b9a\u76f8\u3067\u306f\u30d5\u30ed\u30f3\u30c6\u30a3\u30f3\u30b0\u30d4\u30fc\u30af\u306b\u306a\u308a\u307e\u3059\u304c\u3001\u30b7\u30af\u30ed\u30c7\u30ad\u30b9\u30c8\u30ea\u30f3\u56fa\u5b9a\u76f8\u3067\u306f\u30c6\u30fc\u30ea\u30f3\u30b0\u30d4\u30fc\u30af\u306b\u306a\u308a\u307e\u3059\u3002 Rt-\u03b2DEXsp\u3067\u306e\u30ea\u30ca\u30ed\u30fc\u30eb\u306e\u4f8b\uff5c\u30ab\u30e9\u30e0\u5c0e\u5165\u91cf200 ng\u304b\u3089\u30c6\u30fc\u30ea\u30f3\u30b0\u304c\u767a\u751f 1\u3064\u76ee\u306e\u4f8b\u306f\u3001Rt-\u03b2DEXsp\u3067\u306e\u30ea\u30ca\u30ed\u30fc\u30eb\u306e\u5206\u96e2\u3067\u3059\u3002Figure 1\u306b\u3001\u30ab\u30e9\u30e0\u5c0e\u5165\u91cf\u3092\u5909\u3048\u305f\u3068\u304d\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u3001\u93e1\u50cf\u7570\u6027\u4f53\u30d4\u30fc\u30af\u9593\u306e\u5206\u96e2\u306e\u7a0b\u5ea6\u3092\u793a\u3059Rs\u5024\u3092\u793a\u3057\u307e\u3059\u3002 A\uff0920 ng\uff1aRs 1.82\u3002\u30d4\u30fc\u30af\u306f\u30b7\u30e3\u30fc\u30d7\u3067\u3001\u93e1\u50cf\u7570\u6027\u4f53\u304c\u826f\u597d\u306b\u5206\u96e2\u3057\u3066\u3044\u307e\u3059\u3002 B\uff09200 ng\uff1aRs 1.62\u3002\u30d4\u30fc\u30af\u306b\u30c6\u30fc\u30ea\u30f3\u30b0\u304c\u73fe\u308c\u59cb\u3081\u3001\u5206\u96e2\u304c\u308f\u305a\u304b\u306b\u60aa\u304f\u306a\u3063\u3066\u3044\u307e\u3059\u3002 C\uff092 \u00b5g\uff1aRs 1.46\u3002\u9855\u8457\u306a\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u306b\u3088\u308a\u8457\u3057\u3044\u30c6\u30fc\u30ea\u30f3\u30b0\u304c\u751f\u3058\u3001\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u5206\u96e2\u304c\u5931\u308f\u308c\u3066\u3044\u307e\u3059\u3002 \u5185\u5f840.32 mm\u306e\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u3067\u306f\u3001\u6700\u5927\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u5bb9\u91cf\u306f\u901a\u5e381\u6210\u5206\u3042\u305f\u308a400\uff5e500 ng\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u30ad\u30e9\u30eb\u5316\u5408\u7269\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u304b\u3089\u306f\u3001\u305d\u306e\u7d043\u5206\u306e1\u306e\u91cf\u3067\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u304c\u751f\u3058\u3066\u3044\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002\u3053\u3053\u3067\u3082\u3001\u901a\u5e38\u306e\u30ab\u30e9\u30e0\u3068\u6bd4\u3079\u3066\u3001\u30ad\u30e9\u30eb\u5316\u5408\u7269\u3068\u76f8\u4e92\u4f5c\u7528\u3067\u304d\u308b\u30b7\u30af\u30ed\u30c7\u30ad\u30b9\u30c8\u30ea\u30f3\u306e\u91cf\u304c\u306f\u308b\u304b\u306b\u5c11\u306a\u3044\u3053\u3068\u304c\u8981\u56e0\u3067\u3059\u3002 Figure 1\uff1aRt-\u03b2DEXsp\u306b\u304a\u3051\u308b\u30ea\u30ca\u30ed\u30fc\u30eb\u306e\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\uff08A\u30fbB\u306f\u62e1\u5927\u8868\u793a\uff09 Rt-\u03b2DEXsm\u3067\u306e2,3-\u30d6\u30bf\u30f3\u30b8\u30aa\u30fc\u30eb\u306e\u4f8b\uff5c\u5206\u96e2\u304c\u826f\u597d\u306a\u5834\u5408\u306e\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9 2\u3064\u76ee\u306e\u4f8b\u306f\u3001Rt-\u03b2DEXsm\u3067\u306e2,3-\u30d6\u30bf\u30f3\u30b8\u30aa\u30fc\u30eb\u306e\u5206\u96e2\u3067\u3059\u3002Figure 2\u306b\u3001\u30ab\u30e9\u30e0\u5c0e\u5165\u91cf500 ng\u306825 ng\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u793a\u3057\u307e\u3059\u30022,3-\u30d6\u30bf\u30f3\u30b8\u30aa\u30fc\u30eb\u306b\u306f3\u7a2e\u306e\u7acb\u4f53\u7570\u6027\u4f53\uff081\u5bfe\u306e\u93e1\u50cf\u7570\u6027\u4f53\u3068\u30e1\u30bd\u4f53\uff09\u304c\u3042\u308a\u30013\u672c\u306e\u30d4\u30fc\u30af\u3068\u3057\u3066\u73fe\u308c\u307e\u3059\u3002 A\uff09500 ng\uff1a3\u672c\u306e\u30d4\u30fc\u30af\u3059\u3079\u3066\u306b\u30c6\u30fc\u30ea\u30f3\u30b0\u304c\u898b\u3089\u308c\u3001\u6eb6\u51fa\u3082\u308f\u305a\u304b\u306b\u65e9\u307e\u3063\u3066\u3044\u307e\u3059\u3002 B\uff0925 ng\uff1a\u30d4\u30fc\u30af\u306f\u30b7\u30e3\u30fc\u30d7\u3067\u3001\u30c6\u30fc\u30ea\u30f3\u30b0\u306f\u307b\u3068\u3093\u3069\u898b\u3089\u308c\u307e\u305b\u3093\u3002 \u30ea\u30ca\u30ed\u30fc\u30eb\u306e\u4f8b\u3068\u540c\u69d8\u306b\u3001\u5c0e\u5165\u91cf\u304c\u591a\u3044\u3068\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u306b\u3088\u308b\u30c6\u30fc\u30ea\u30f3\u30b0\u304c\u751f\u3058\u307e\u3059\u3002\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u306e\u7a0b\u5ea6\u306f\u30ea\u30ca\u30ed\u30fc\u30eb\u306e\u4f8b\u3088\u308a\u5927\u304d\u3044\u3082\u306e\u306e\u3001\u3053\u306e\u5316\u5408\u7269\u3067\u306f\u7570\u6027\u4f53\u540c\u58eb\u304c\u5927\u304d\u304f\u96e2\u308c\u3066\u6eb6\u51fa\u3057\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001500 ng\u3067\u3082\u5404\u30d4\u30fc\u30af\u306f\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u307e\u3067\u5206\u96e2\u3057\u3066\u304a\u308a\u3001\u5206\u96e2\u306e\u60aa\u5316\u306f\u305d\u308c\u307b\u3069\u76ee\u7acb\u3061\u307e\u305b\u3093\u3002 Figure 2\uff1aRt-\u03b2DEXsm\u306b\u304a\u3051\u308b\u30d6\u30bf\u30f3\u30b8\u30aa\u30fc\u30eb\u306e\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9 \u3088\u304f\u3042\u308b\u8cea\u554f \u30ad\u30e9\u30eb\u30ab\u30e9\u30e0\u3067\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u3059\u308b\u3068\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u306f\u3069\u3046\u306a\u308a\u307e\u3059\u304b\uff1f \u901a\u5e38\u306e\u56fa\u5b9a\u76f8\u3067\u306f\u30d5\u30ed\u30f3\u30c6\u30a3\u30f3\u30b0\u30d4\u30fc\u30af\u306b\u306a\u308a\u307e\u3059\u304c\u3001\u30b7\u30af\u30ed\u30c7\u30ad\u30b9\u30c8\u30ea\u30f3\u56fa\u5b9a\u76f8\u3067\u306f\u30c6\u30fc\u30ea\u30f3\u30b0\u30d4\u30fc\u30af\u306b\u306a\u308a\u307e\u3059\u3002 \u30ad\u30e9\u30eb\u30ab\u30e9\u30e0\u3067\u306f\u3001\u3069\u306e\u304f\u3089\u3044\u306e\u91cf\u304b\u3089\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u304c\u8d77\u304d\u307e\u3059\u304b\uff1f \u5185\u5f840.32 mm\u306e\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306e\u8ca0\u8377\u5bb9\u91cf\u306f\u901a\u5e381\u6210\u5206\u3042\u305f\u308a400\uff5e500 ng\u3067\u3059\u304c\u3001\u30ad\u30e9\u30eb\u5316\u5408\u7269\u3067\u306f\u305d\u306e\u7d043\u5206\u306e1\u306e\u91cf\u3067\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u304c\u751f\u3058\u307e\u3059\u3002Rt-\u03b2DEXsp\u3067\u306e\u30ea\u30ca\u30ed\u30fc\u30eb\u306e\u4f8b\u3067\u306f\u3001200 ng\u3067\u30c6\u30fc\u30ea\u30f3\u30b0\u304c\u73fe\u308c\u59cb\u3081\u307e\u3057\u305f\u3002 \u307e\u3068\u3081 \u30b7\u30af\u30ed\u30c7\u30ad\u30b9\u30c8\u30ea\u30f3\u56fa\u5b9a\u76f8\u3067\u306f\u3001\u30ad\u30e9\u30eb\u5316\u5408\u7269\u3068\u76f8\u4e92\u4f5c\u7528\u3067\u304d\u308b\u30b7\u30af\u30ed\u30c7\u30ad\u30b9\u30c8\u30ea\u30f3\u306e\u91cf\u304c\u9650\u3089\u308c\u308b\u305f\u3081\u3001\u901a\u5e38\u306e\u30ab\u30e9\u30e0\u3088\u308a\u5c11\u306a\u3044\u5c0e\u5165\u91cf\u3067\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u304c\u8d77\u3053\u308a\u3001\u30c6\u30fc\u30ea\u30f3\u30b0\u304c\u751f\u3058\u307e\u3059\u3002\u826f\u597d\u306a\u30ad\u30e9\u30eb\u5206\u96e2\u3092\u5f97\u308b\u306b\u306f\u3001\u30ab\u30e9\u30e0\u5c0e\u5165\u91cf\u3092\u6291\u3048\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002 \u6b21\u56de\u304b\u3089\u306f\u3001\u500b\u3005\u306e\u30ab\u30e9\u30e0\u3068\u5177\u4f53\u7684\u306a\u5206\u96e2\u4f8b\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u307e\u305a\u306fRt-\u03b2DEXm\u3001Rt-\u03b2DEXsm\u3001Rt-\u03b2DEXse\u3092\u53d6\u308a\u4e0a\u3052\u307e\u3059\u3002GC\u30ad\u30e9\u30eb\u5206\u67904\uff1aRt-\u03b2DEXm\u3001Rt-\u03b2DEXsm\u3001Rt-\u03b2DEXse\u306b\u3088\u308b\u5206\u96e2\u3092\u8aad\u3080<\/p>\n","protected":false},"author":50,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[2816],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[591],"class_list":["post-105532","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","tag-gc"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"post_tag":[{"value":2816,"label":"GC"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jana Hepner, PhD","author_link":"https:\/\/discover.restek.com\/ja\/author\/jana-hepner-phd\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":[{"term_id":2816,"name":"GC","slug":"gc","term_group":0,"term_taxonomy_id":2816,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw"}],"authors":[{"term_id":591,"user_id":50,"is_guest":0,"slug":"jana-hepner-phd","display_name":"Jana Hepner, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hepner-jana.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hepner-jana.jpg"},"author_category":"1","first_name":"Jana","last_name":"Hepner","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/105532","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/50"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=105532"}],"version-history":[{"count":12,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/105532\/revisions"}],"predecessor-version":[{"id":106670,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/105532\/revisions\/106670"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=105532"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=105532"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=105532"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=105532"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=105532"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=105532"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=105532"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=105532"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=105532"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}