{"id":105684,"date":"2022-08-14T14:30:00","date_gmt":"2022-08-14T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=105684"},"modified":"2026-11-13T01:48:12","modified_gmt":"2026-11-13T01:48:12","slug":"chiral-separations-8-essential-oils-and-fragrance-on-rt-bdexsa","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4625-ja\/chiral-separations-8-essential-oils-and-fragrance-on-rt-bdexsa","title":{"rendered":"GC\u30ad\u30e9\u30eb\u5206\u6790 8\uff1aRt-\u03b2DEXsa\u306b\u3088\u308b\u7cbe\u6cb9\u30fb\u9999\u6599\u306e\u5206\u6790"},"content":{"rendered":"\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"363\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-chiral-separations-8-essential-oils-and-fragrance-on-rt-bdexsaa-01-1024x363.jpg\" alt=\"bottles of liquids on a table with flower petals surrounding them\" class=\"wp-image-13402\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-chiral-separations-8-essential-oils-and-fragrance-on-rt-bdexsaa-01-1024x363.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-chiral-separations-8-essential-oils-and-fragrance-on-rt-bdexsaa-01-300x106.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-chiral-separations-8-essential-oils-and-fragrance-on-rt-bdexsaa-01-768x272.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-chiral-separations-8-essential-oils-and-fragrance-on-rt-bdexsaa-01-1536x545.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-chiral-separations-8-essential-oils-and-fragrance-on-rt-bdexsaa-01-2048x726.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<style data-wp-block-html=\"css\">\n<style>\n.rtk-article { line-height: 1.8; font-size: 16px; }\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n.rtk-article h2 {\n  margin-top: 5em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n.rtk-article h3 {\n  margin-top: 3em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n.rtk-article p {\n  font-size: 18px;\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n.rtk-article a {\n  font-size: inherit !important;\n}\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n.rtk-article .rtk-lead {\n  font-size: 18px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n.rtk-article blockquote.rtk-voc {\n  position: relative;\n  border-left: 4px solid #00265d;\n  background: #f7f8f9;\n  padding: 18px 22px 18px 30px;\n  margin: 2em 0;\n  font-style: italic;\n  color: #333;\n}\n.rtk-article blockquote.rtk-voc p { margin-bottom: 0.4em; }\n.rtk-article blockquote.rtk-voc cite {\n  display: block;\n  font-style: normal;\n  font-size: 13px;\n  color: #4a4a4a;\n}\n.rtk-article .rtk-coa-list {\n  list-style: none;\n  padding: 0;\n}\n.rtk-article .rtk-coa-list li {\n  background: #fafbfc;\n  border: 1px solid #e1e8ec;\n  border-radius: 6px;\n  padding: 14px 18px;\n  margin-bottom: 12px;\n}\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n\/* ===== v3 \u8ffd\u52a0\uff1a\u82f1\u8a9e\u7248\u306e\u898b\u3048\u65b9\u306b\u5408\u308f\u305b\u305f\u30b3\u30f3\u30dd\u30fc\u30cd\u30f3\u30c8 ===== *\/\n\n\/* \u756a\u53f7\u4ed8\u304d\u30b9\u30c6\u30c3\u30d7\u898b\u51fa\u3057\uff08\u82f1\u8a9e\u7248\u306e\u300c01 | \u898b\u51fa\u3057\u300d\u8868\u793a\uff09 *\/\n.rtk-article h3.rtk-step {\n  display: flex;\n  align-items: baseline;\n  padding-left: 0;\n  border-left: none;\n}\n.rtk-article .rtk-step-num {\n  flex-shrink: 0;\n  font-weight: 700;\n  font-size: 1.25em;\n  line-height: 1.1;\n  color: #0d7bc4;\n  padding-right: 0.55em;\n  margin-right: 0.55em;\n  border-right: 2px solid #cde3f2;\n  font-variant-numeric: tabular-nums;\n}\n\n\/* \u811a\u6ce8\u30fb\u6ce8\u8a18\uff08*NIST \u7b49\uff09 *\/\n.rtk-article .rtk-note {\n  font-size: 14px;\n  color: #4a4a4a;\n}\n\n\/* \u8a3c\u660e\u66f8\u30ab\u30fc\u30c9\u5185\u306e\u898b\u51fa\u3057\u3092\u6539\u884c\u3057\u3066\u5f37\u8abf *\/\n.rtk-article .rtk-coa-list li strong {\n  display: block;\n  margin-bottom: 0.3em;\n  color: #00265d;\n}\n\n\/* \u30bb\u30af\u30b7\u30e7\u30f3\u672b\u5c3e\u306e\u30dc\u30bf\u30f3\u578bCTA *\/\n.rtk-article .rtk-cta-links {\n  display: flex;\n  flex-wrap: wrap;\n  gap: 12px;\n  margin: 2em 0 1em;\n}\n.rtk-article a.rtk-button {\n  display: inline-block;\n  padding: 12px 22px;\n  border-radius: 6px;\n  background: #0d7bc4;\n  border: 2px solid #0d7bc4;\n  color: #fff;\n  font-weight: 700;\n  text-decoration: none;\n  line-height: 1.4;\n}\n.rtk-article a.rtk-button:hover {\n  background: #00265d;\n  border-color: #00265d;\n}\n.rtk-article a.rtk-button--ghost {\n  background: #fff;\n  color: #0d7bc4;\n}\n.rtk-article a.rtk-button--ghost:hover {\n  background: #eef6fc;\n  border-color: #0d7bc4;\n}\n\n\/* \u8a18\u4e8b\u672b\u5c3e\u306e\u76f8\u8ac7\u30dc\u30c3\u30af\u30b9\uff08\u82f1\u8a9e\u7248\u306e Need Help \u76f8\u5f53\uff09 *\/\n.rtk-article .rtk-help {\n  background: #00265d;\n  color: #fff;\n  border-radius: 6px;\n  padding: 24px 26px;\n  margin: 3em 0 1em;\n}\n.rtk-article .rtk-help p { color: #fff; }\n.rtk-article .rtk-help .rtk-help-title {\n  font-size: 20px;\n  font-weight: 700;\n  margin-bottom: 0.4em;\n}\n.rtk-article .rtk-help a.rtk-button {\n  background: #fff;\n  border-color: #fff;\n  color: #00265d;\n  margin-top: 0.6em;\n}\n.rtk-article .rtk-help a.rtk-button:hover {\n  background: #eef6fc;\n  border-color: #eef6fc;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 3.5em; }\n  .rtk-article h3 { margin-top: 2.2em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout,\n  .rtk-article blockquote.rtk-voc {\n    padding: 14px 16px;\n  }\n  .rtk-article .rtk-cta-links { flex-direction: column; }\n  .rtk-article a.rtk-button { display: block; text-align: center; }\n  .rtk-article .rtk-help { padding: 18px 16px; }\n}\n<\/style>\n<\/style>\n\n<div class=\"rtk-article\">\n<div class=\"rtk-intro\">\n<p class=\"rtk-lead\">\u4eca\u56de\u306f\u518d\u3073Rt-\u03b2DEXsa\u30ab\u30e9\u30e0\u3092\u53d6\u308a\u4e0a\u3052\u3001\u30ed\u30fc\u30ba\u6cb9\u3068\u9999\u6599\u3078\u306e\u9069\u7528\u4f8b\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002Rt-\u03b2DEXsa\u306f\u3001\u307b\u304b\u306e\u30ad\u30e9\u30eb\u30ab\u30e9\u30e0\u3068\u9078\u629e\u6027\u304c\u5927\u304d\u304f\u7570\u306a\u308a\u307e\u3059\u30021-\u30aa\u30af\u30c6\u30f3-3-\u30aa\u30fc\u30eb\u3001\u30ab\u30eb\u30dc\u30f3\u3001\u30ab\u30f3\u30d5\u30a1\u30fc\u3001\u03b2-\u30b7\u30c8\u30ed\u30cd\u30ed\u30fc\u30eb\u3001\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u3067\u6700\u3082\u826f\u597d\u306a\u5206\u96e2\u304c\u5f97\u3089\u308c\u308b\u305f\u3081\u3001\u7279\u5b9a\u306e\u7cbe\u6cb9\u306e\u5206\u6790\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u3053\u3067\u306f\u3001\u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u3001\u7d14\u6b63\u30ed\u30fc\u30ba\u6cb9\u3001\u30ed\u30fc\u30ba\u9999\u6599\u3092\u53d6\u308a\u4e0a\u3052\u307e\u3059\u3002<\/p>\n<\/div>\n\n<div style=\"margin-top: 5em;\"><\/div>\n\n<h2>\u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\uff5c\u30e9\u30bb\u30df\u4f53\u306e\u691c\u51fa\u306b\u3088\u308b\u771f\u6b63\u6027\u306e\u5224\u5225<\/h2>\n\n<p>\u30bc\u30e9\u30cb\u30a6\u30e0\u306f\u30d0\u30e9\u985e\uff08Rosids\uff09\u306b\u5c5e\u3059\u308b\u690d\u7269\u3067\u3042\u308a\u3001\u305d\u306e\u7cbe\u6cb9\u306e\u7d44\u6210\u306f\u30ed\u30fc\u30ba\u6cb9\u3068\u985e\u4f3c\u3057\u3066\u3044\u307e\u3059\u3002\u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u306e\u30ad\u30e9\u30eb\u6210\u5206\u306b\u306f\u3001cis-\u304a\u3088\u3073trans-\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u3001\u30e1\u30f3\u30c8\u30f3\u3001\u30ea\u30ca\u30ed\u30fc\u30eb\u3001\u03b2-\u30b7\u30c8\u30ed\u30cd\u30ed\u30fc\u30eb\u304c\u3042\u308a\u307e\u3059\u3002Rt-\u03b2DEXsa\u30ab\u30e9\u30e0\u3067\u306f\u3001\u3053\u308c\u3089\u3059\u3079\u3066\u306e\u5316\u5408\u7269\u3067\u30ad\u30e9\u30eb\u5206\u96e2\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/p>\n\n<p>\u771f\u6b63\u306a\u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u3067\u306f\u3001cis-\u304a\u3088\u3073trans-\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u306e(\u2212)-(4R)\u914d\u7f6e\u306e\u30b8\u30a2\u30b9\u30c6\u30ec\u30aa\u30de\u30fc\u304c\u3001(+)-\u93e1\u50cf\u7570\u6027\u4f53\u3088\u308a\u591a\u304f\u542b\u307e\u308c\u307e\u3059\u3002\u307e\u305f\u3001\u03b2-\u30b7\u30c8\u30ed\u30cd\u30ed\u30fc\u30eb\u306e\u93e1\u50cf\u7570\u6027\u4f53\u6bd4\u306f\u3001(\u2212)-(S)\u4f53\u304c74\uff5e80%\u3068\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n<p><strong>Figure 1<\/strong>\u306b\u793a\u3059\u3068\u304a\u308a\u3001\u4eca\u56de\u306e\u5e02\u8ca9\u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u3067\u306f\u3001cis-\u304a\u3088\u3073trans-\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u3068\u03b2-\u30b7\u30c8\u30ed\u30cd\u30ed\u30fc\u30eb\u304c\u30e9\u30bb\u30df\u4f53\u3068\u306a\u3063\u3066\u3044\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u30e9\u30bb\u30df\u4f53\u306e\u5b58\u5728\u304b\u3089\u3001\u672c\u7cbe\u6cb9\u306f\u771f\u6b63\u54c1\u3067\u306f\u306a\u3044\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1372.png\" alt=\"Geranium Oil on Rt-\u03b2DEXsa\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1372<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> 1<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> 2<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> 3<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> 4<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Rose oxides\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/16409-43-1\/Rose oxides\" target=\"_blank\" rel=\"noopener\">Rose oxides<\/a><\/td><td class=\"oth\">22.701<\/td><td class=\"oth\">22.931<\/td><td class=\"oth\">23.370<\/td><td class=\"oth\">23.616<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (-) Menthone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/89-80-5\/(-) Menthone\" target=\"_blank\" rel=\"noopener\">(-) Menthone<\/a><\/td><td class=\"oth\">28.420<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Linalool (\u00b1)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78-70-6\/Linalool\" target=\"_blank\" rel=\"noopener\">Linalool (\u00b1)<\/a><\/td><td class=\"oth\">30.919<\/td><td class=\"oth\">31.298<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b2-Citronellol (\u00b1)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-22-9\/\u03b2-Citronellol\" target=\"_blank\" rel=\"noopener\">\u03b2-Citronellol (\u00b1)<\/a><\/td><td class=\"oth\">37.090<\/td><td class=\"oth\">37.245<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Geraniol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-24-1\/Geraniol\" target=\"_blank\" rel=\"noopener\">Geraniol<\/a><\/td><td class=\"oth\">39.494<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>13108<\/li><li>23305<\/li><li>21143<\/li><li>24495<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Chiral<\/li><li>rose<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1372.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\"><em><strong>Figure 1\uff1a<\/strong>Rt-\u03b2DEXsa\u306b\u3088\u308b\u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u306e\u5206\u6790\uff08GC_FF1372\uff09<\/em><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<style data-wp-block-html=\"css\">\n<style>\n.rtk-article { line-height: 1.8; font-size: 16px; }\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n.rtk-article h2 {\n  margin-top: 5em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n.rtk-article h3 {\n  margin-top: 3em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n.rtk-article p {\n  font-size: 18px;\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n.rtk-article a {\n  font-size: inherit !important;\n}\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n.rtk-article .rtk-lead {\n  font-size: 18px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n.rtk-article blockquote.rtk-voc {\n  position: relative;\n  border-left: 4px solid #00265d;\n  background: #f7f8f9;\n  padding: 18px 22px 18px 30px;\n  margin: 2em 0;\n  font-style: italic;\n  color: #333;\n}\n.rtk-article blockquote.rtk-voc p { margin-bottom: 0.4em; }\n.rtk-article blockquote.rtk-voc cite {\n  display: block;\n  font-style: normal;\n  font-size: 13px;\n  color: #4a4a4a;\n}\n.rtk-article .rtk-coa-list {\n  list-style: none;\n  padding: 0;\n}\n.rtk-article .rtk-coa-list li {\n  background: #fafbfc;\n  border: 1px solid #e1e8ec;\n  border-radius: 6px;\n  padding: 14px 18px;\n  margin-bottom: 12px;\n}\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n\/* ===== v3 \u8ffd\u52a0\uff1a\u82f1\u8a9e\u7248\u306e\u898b\u3048\u65b9\u306b\u5408\u308f\u305b\u305f\u30b3\u30f3\u30dd\u30fc\u30cd\u30f3\u30c8 ===== *\/\n\n\/* \u756a\u53f7\u4ed8\u304d\u30b9\u30c6\u30c3\u30d7\u898b\u51fa\u3057\uff08\u82f1\u8a9e\u7248\u306e\u300c01 | \u898b\u51fa\u3057\u300d\u8868\u793a\uff09 *\/\n.rtk-article h3.rtk-step {\n  display: flex;\n  align-items: baseline;\n  padding-left: 0;\n  border-left: none;\n}\n.rtk-article .rtk-step-num {\n  flex-shrink: 0;\n  font-weight: 700;\n  font-size: 1.25em;\n  line-height: 1.1;\n  color: #0d7bc4;\n  padding-right: 0.55em;\n  margin-right: 0.55em;\n  border-right: 2px solid #cde3f2;\n  font-variant-numeric: tabular-nums;\n}\n\n\/* \u811a\u6ce8\u30fb\u6ce8\u8a18\uff08*NIST \u7b49\uff09 *\/\n.rtk-article .rtk-note {\n  font-size: 14px;\n  color: #4a4a4a;\n}\n\n\/* \u8a3c\u660e\u66f8\u30ab\u30fc\u30c9\u5185\u306e\u898b\u51fa\u3057\u3092\u6539\u884c\u3057\u3066\u5f37\u8abf *\/\n.rtk-article .rtk-coa-list li strong {\n  display: block;\n  margin-bottom: 0.3em;\n  color: #00265d;\n}\n\n\/* \u30bb\u30af\u30b7\u30e7\u30f3\u672b\u5c3e\u306e\u30dc\u30bf\u30f3\u578bCTA *\/\n.rtk-article .rtk-cta-links {\n  display: flex;\n  flex-wrap: wrap;\n  gap: 12px;\n  margin: 2em 0 1em;\n}\n.rtk-article a.rtk-button {\n  display: inline-block;\n  padding: 12px 22px;\n  border-radius: 6px;\n  background: #0d7bc4;\n  border: 2px solid #0d7bc4;\n  color: #fff;\n  font-weight: 700;\n  text-decoration: none;\n  line-height: 1.4;\n}\n.rtk-article a.rtk-button:hover {\n  background: #00265d;\n  border-color: #00265d;\n}\n.rtk-article a.rtk-button--ghost {\n  background: #fff;\n  color: #0d7bc4;\n}\n.rtk-article a.rtk-button--ghost:hover {\n  background: #eef6fc;\n  border-color: #0d7bc4;\n}\n\n\/* \u8a18\u4e8b\u672b\u5c3e\u306e\u76f8\u8ac7\u30dc\u30c3\u30af\u30b9\uff08\u82f1\u8a9e\u7248\u306e Need Help \u76f8\u5f53\uff09 *\/\n.rtk-article .rtk-help {\n  background: #00265d;\n  color: #fff;\n  border-radius: 6px;\n  padding: 24px 26px;\n  margin: 3em 0 1em;\n}\n.rtk-article .rtk-help p { color: #fff; }\n.rtk-article .rtk-help .rtk-help-title {\n  font-size: 20px;\n  font-weight: 700;\n  margin-bottom: 0.4em;\n}\n.rtk-article .rtk-help a.rtk-button {\n  background: #fff;\n  border-color: #fff;\n  color: #00265d;\n  margin-top: 0.6em;\n}\n.rtk-article .rtk-help a.rtk-button:hover {\n  background: #eef6fc;\n  border-color: #eef6fc;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 3.5em; }\n  .rtk-article h3 { margin-top: 2.2em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout,\n  .rtk-article blockquote.rtk-voc {\n    padding: 14px 16px;\n  }\n  .rtk-article .rtk-cta-links { flex-direction: column; }\n  .rtk-article a.rtk-button { display: block; text-align: center; }\n  .rtk-article .rtk-help { padding: 18px 16px; }\n}\n<\/style>\n<\/style>\n\n<div class=\"rtk-article\">\n<h2>\u30ed\u30fc\u30ba\u6cb9\u3068\u30ed\u30fc\u30ba\u9999\u6599\uff5c\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u306e\u6709\u7121\u3068\u93e1\u50cf\u7570\u6027\u4f53\u6bd4\u306b\u3088\u308b\u5224\u5225<\/h2>\n\n<p>\u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u3068\u540c\u69d8\u306b\u3001\u30ed\u30fc\u30ba\u6cb9\u306b\u3082\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u3068\u03b2-\u30b7\u30c8\u30ed\u30cd\u30ed\u30fc\u30eb\u304c\u542b\u307e\u308c\u307e\u3059\uff08<strong>Figure 2<\/strong>\uff09\u3002\u30e1\u30f3\u30c8\u30f3\u3082\u542b\u307e\u308c\u307e\u3059\u304c\u3001\u305d\u306e\u91cf\u306f\u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u3088\u308a\u5c11\u306a\u304f\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u306e\u30ed\u30fc\u30ba\u6cb9\u30b5\u30f3\u30d7\u30eb\u3067\u306f\u3001\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u306e\u91cf\u3082\u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u3088\u308a\u306f\u308b\u304b\u306b\u5c11\u306a\u304f\u30014\u7a2e\u306e\u7570\u6027\u4f53\u304c\u3059\u3079\u3066\u691c\u51fa\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n<p>4\u7a2e\u306e\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u7570\u6027\u4f53\u304c\u3059\u3079\u3066\u691c\u51fa\u3055\u308c\u3001\u3055\u3089\u306b\u03b2-\u30b7\u30c8\u30ed\u30cd\u30ed\u30fc\u30eb\u306e\u4e21\u93e1\u50cf\u7570\u6027\u4f53\u304c\u307b\u307c\u540c\u91cf\u5b58\u5728\u3059\u308b\u3053\u3068\u304b\u3089\u3001\u672c\u30b5\u30f3\u30d7\u30eb\u306f\u771f\u6b63\u54c1\u3067\u306f\u306a\u3044\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1373.png\" alt=\"Rose Oil on Rt-\u03b2DEXsa\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1373<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> 1<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> 2<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> 3<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> 4<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Rose oxides\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/16409-43-1\/Rose oxides\" target=\"_blank\" rel=\"noopener\">Rose oxides<\/a><\/td><td class=\"oth\">22.700<\/td><td class=\"oth\">22.920<\/td><td class=\"oth\">23.360<\/td><td class=\"oth\">23.610<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (-) Menthone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/89-80-5\/(-) Menthone\" target=\"_blank\" rel=\"noopener\">(-) Menthone<\/a><\/td><td class=\"oth\">28.416<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b2-Citronellol (\u00b1)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-22-9\/\u03b2-Citronellol\" target=\"_blank\" rel=\"noopener\">\u03b2-Citronellol (\u00b1)<\/a><\/td><td class=\"oth\">37.066<\/td><td class=\"oth\">37.230<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Geraniol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-24-1\/Geraniol\" target=\"_blank\" rel=\"noopener\">Geraniol<\/a><\/td><td class=\"oth\">39.805<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>13108<\/li><li>23305<\/li><li>21143<\/li><li>24495<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Chiral<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1373.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\"><em><strong>Figure 2\uff1a<\/strong>Rt-\u03b2DEXsa\u306b\u3088\u308b\u30ed\u30fc\u30ba\u6cb9\u306e\u5206\u6790\uff08GC_FF1373\uff09<\/em><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<style data-wp-block-html=\"css\">\n<style>\n.rtk-article { line-height: 1.8; font-size: 16px; }\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n.rtk-article h2 {\n  margin-top: 5em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n.rtk-article h3 {\n  margin-top: 3em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n.rtk-article p {\n  font-size: 18px;\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n.rtk-article a {\n  font-size: inherit !important;\n}\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n.rtk-article .rtk-lead {\n  font-size: 18px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n.rtk-article blockquote.rtk-voc {\n  position: relative;\n  border-left: 4px solid #00265d;\n  background: #f7f8f9;\n  padding: 18px 22px 18px 30px;\n  margin: 2em 0;\n  font-style: italic;\n  color: #333;\n}\n.rtk-article blockquote.rtk-voc p { margin-bottom: 0.4em; }\n.rtk-article blockquote.rtk-voc cite {\n  display: block;\n  font-style: normal;\n  font-size: 13px;\n  color: #4a4a4a;\n}\n.rtk-article .rtk-coa-list {\n  list-style: none;\n  padding: 0;\n}\n.rtk-article .rtk-coa-list li {\n  background: #fafbfc;\n  border: 1px solid #e1e8ec;\n  border-radius: 6px;\n  padding: 14px 18px;\n  margin-bottom: 12px;\n}\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n\/* ===== v3 \u8ffd\u52a0\uff1a\u82f1\u8a9e\u7248\u306e\u898b\u3048\u65b9\u306b\u5408\u308f\u305b\u305f\u30b3\u30f3\u30dd\u30fc\u30cd\u30f3\u30c8 ===== *\/\n\n\/* \u756a\u53f7\u4ed8\u304d\u30b9\u30c6\u30c3\u30d7\u898b\u51fa\u3057\uff08\u82f1\u8a9e\u7248\u306e\u300c01 | \u898b\u51fa\u3057\u300d\u8868\u793a\uff09 *\/\n.rtk-article h3.rtk-step {\n  display: flex;\n  align-items: baseline;\n  padding-left: 0;\n  border-left: none;\n}\n.rtk-article .rtk-step-num {\n  flex-shrink: 0;\n  font-weight: 700;\n  font-size: 1.25em;\n  line-height: 1.1;\n  color: #0d7bc4;\n  padding-right: 0.55em;\n  margin-right: 0.55em;\n  border-right: 2px solid #cde3f2;\n  font-variant-numeric: tabular-nums;\n}\n\n\/* \u811a\u6ce8\u30fb\u6ce8\u8a18\uff08*NIST \u7b49\uff09 *\/\n.rtk-article .rtk-note {\n  font-size: 14px;\n  color: #4a4a4a;\n}\n\n\/* \u8a3c\u660e\u66f8\u30ab\u30fc\u30c9\u5185\u306e\u898b\u51fa\u3057\u3092\u6539\u884c\u3057\u3066\u5f37\u8abf *\/\n.rtk-article .rtk-coa-list li strong {\n  display: block;\n  margin-bottom: 0.3em;\n  color: #00265d;\n}\n\n\/* \u30bb\u30af\u30b7\u30e7\u30f3\u672b\u5c3e\u306e\u30dc\u30bf\u30f3\u578bCTA *\/\n.rtk-article .rtk-cta-links {\n  display: flex;\n  flex-wrap: wrap;\n  gap: 12px;\n  margin: 2em 0 1em;\n}\n.rtk-article a.rtk-button {\n  display: inline-block;\n  padding: 12px 22px;\n  border-radius: 6px;\n  background: #0d7bc4;\n  border: 2px solid #0d7bc4;\n  color: #fff;\n  font-weight: 700;\n  text-decoration: none;\n  line-height: 1.4;\n}\n.rtk-article a.rtk-button:hover {\n  background: #00265d;\n  border-color: #00265d;\n}\n.rtk-article a.rtk-button--ghost {\n  background: #fff;\n  color: #0d7bc4;\n}\n.rtk-article a.rtk-button--ghost:hover {\n  background: #eef6fc;\n  border-color: #0d7bc4;\n}\n\n\/* \u8a18\u4e8b\u672b\u5c3e\u306e\u76f8\u8ac7\u30dc\u30c3\u30af\u30b9\uff08\u82f1\u8a9e\u7248\u306e Need Help \u76f8\u5f53\uff09 *\/\n.rtk-article .rtk-help {\n  background: #00265d;\n  color: #fff;\n  border-radius: 6px;\n  padding: 24px 26px;\n  margin: 3em 0 1em;\n}\n.rtk-article .rtk-help p { color: #fff; }\n.rtk-article .rtk-help .rtk-help-title {\n  font-size: 20px;\n  font-weight: 700;\n  margin-bottom: 0.4em;\n}\n.rtk-article .rtk-help a.rtk-button {\n  background: #fff;\n  border-color: #fff;\n  color: #00265d;\n  margin-top: 0.6em;\n}\n.rtk-article .rtk-help a.rtk-button:hover {\n  background: #eef6fc;\n  border-color: #eef6fc;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 3.5em; }\n  .rtk-article h3 { margin-top: 2.2em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout,\n  .rtk-article blockquote.rtk-voc {\n    padding: 14px 16px;\n  }\n  .rtk-article .rtk-cta-links { flex-direction: column; }\n  .rtk-article a.rtk-button { display: block; text-align: center; }\n  .rtk-article .rtk-help { padding: 18px 16px; }\n}\n<\/style>\n\n<div class=\"rtk-article\">\n<p>\u30ed\u30fc\u30ba\u9999\u6599\u3067\u306f\u3001\u30ed\u30fc\u30ba\u6cb9\u306e\u4ee3\u8868\u7684\u306a\u6210\u5206\u306e\u4e00\u90e8\u304c\u691c\u51fa\u3055\u308c\u307e\u3057\u305f\u304c\u3001\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u306f\u307e\u3063\u305f\u304f\u691c\u51fa\u3055\u308c\u307e\u305b\u3093\u3067\u3057\u305f\uff08<strong>Figure 3<\/strong>\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1375.png\" alt=\"Rose Fragrance on Rt-\u03b2DEXsa\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1375<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> 1<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (-) Menthone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/89-80-5\/(-) Menthone\" target=\"_blank\" rel=\"noopener\">(-) Menthone<\/a><\/td><td class=\"oth\">28.416<\/td><td class=\"oth\">-<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b2-Citronellol (\u00b1)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-22-9\/\u03b2-Citronellol\" target=\"_blank\" rel=\"noopener\">\u03b2-Citronellol (\u00b1)<\/a><\/td><td class=\"oth\">37.066<\/td><td class=\"oth\">37.230<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Geraniol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-24-1\/Geraniol\" target=\"_blank\" rel=\"noopener\">Geraniol<\/a><\/td><td class=\"oth\">39.805<\/td><td class=\"oth\">-<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>13108<\/li><li>23305<\/li><li>21143<\/li><li>24495<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Chiral<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1375.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\"><em><strong>Figure 3\uff1a<\/strong>Rt-\u03b2DEXsa\u306b\u3088\u308b\u30ed\u30fc\u30ba\u9999\u6599\u306e\u5206\u6790\uff08GC_FF1375\uff09<\/em><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<style data-wp-block-html=\"css\">\n<style>\n.rtk-article { line-height: 1.8; font-size: 16px; }\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n.rtk-article h2 {\n  margin-top: 5em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n.rtk-article h3 {\n  margin-top: 3em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n.rtk-article p {\n  font-size: 18px;\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n.rtk-article a {\n  font-size: inherit !important;\n}\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n.rtk-article .rtk-lead {\n  font-size: 18px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n.rtk-article blockquote.rtk-voc {\n  position: relative;\n  border-left: 4px solid #00265d;\n  background: #f7f8f9;\n  padding: 18px 22px 18px 30px;\n  margin: 2em 0;\n  font-style: italic;\n  color: #333;\n}\n.rtk-article blockquote.rtk-voc p { margin-bottom: 0.4em; }\n.rtk-article blockquote.rtk-voc cite {\n  display: block;\n  font-style: normal;\n  font-size: 13px;\n  color: #4a4a4a;\n}\n.rtk-article .rtk-coa-list {\n  list-style: none;\n  padding: 0;\n}\n.rtk-article .rtk-coa-list li {\n  background: #fafbfc;\n  border: 1px solid #e1e8ec;\n  border-radius: 6px;\n  padding: 14px 18px;\n  margin-bottom: 12px;\n}\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n\/* ===== v3 \u8ffd\u52a0\uff1a\u82f1\u8a9e\u7248\u306e\u898b\u3048\u65b9\u306b\u5408\u308f\u305b\u305f\u30b3\u30f3\u30dd\u30fc\u30cd\u30f3\u30c8 ===== *\/\n\n\/* \u756a\u53f7\u4ed8\u304d\u30b9\u30c6\u30c3\u30d7\u898b\u51fa\u3057\uff08\u82f1\u8a9e\u7248\u306e\u300c01 | \u898b\u51fa\u3057\u300d\u8868\u793a\uff09 *\/\n.rtk-article h3.rtk-step {\n  display: flex;\n  align-items: baseline;\n  padding-left: 0;\n  border-left: none;\n}\n.rtk-article .rtk-step-num {\n  flex-shrink: 0;\n  font-weight: 700;\n  font-size: 1.25em;\n  line-height: 1.1;\n  color: #0d7bc4;\n  padding-right: 0.55em;\n  margin-right: 0.55em;\n  border-right: 2px solid #cde3f2;\n  font-variant-numeric: tabular-nums;\n}\n\n\/* \u811a\u6ce8\u30fb\u6ce8\u8a18\uff08*NIST \u7b49\uff09 *\/\n.rtk-article .rtk-note {\n  font-size: 14px;\n  color: #4a4a4a;\n}\n\n\/* \u8a3c\u660e\u66f8\u30ab\u30fc\u30c9\u5185\u306e\u898b\u51fa\u3057\u3092\u6539\u884c\u3057\u3066\u5f37\u8abf *\/\n.rtk-article .rtk-coa-list li strong {\n  display: block;\n  margin-bottom: 0.3em;\n  color: #00265d;\n}\n\n\/* \u30bb\u30af\u30b7\u30e7\u30f3\u672b\u5c3e\u306e\u30dc\u30bf\u30f3\u578bCTA *\/\n.rtk-article .rtk-cta-links {\n  display: flex;\n  flex-wrap: wrap;\n  gap: 12px;\n  margin: 2em 0 1em;\n}\n.rtk-article a.rtk-button {\n  display: inline-block;\n  padding: 12px 22px;\n  border-radius: 6px;\n  background: #0d7bc4;\n  border: 2px solid #0d7bc4;\n  color: #fff;\n  font-weight: 700;\n  text-decoration: none;\n  line-height: 1.4;\n}\n.rtk-article a.rtk-button:hover {\n  background: #00265d;\n  border-color: #00265d;\n}\n.rtk-article a.rtk-button--ghost {\n  background: #fff;\n  color: #0d7bc4;\n}\n.rtk-article a.rtk-button--ghost:hover {\n  background: #eef6fc;\n  border-color: #0d7bc4;\n}\n\n\/* \u8a18\u4e8b\u672b\u5c3e\u306e\u76f8\u8ac7\u30dc\u30c3\u30af\u30b9\uff08\u82f1\u8a9e\u7248\u306e Need Help \u76f8\u5f53\uff09 *\/\n.rtk-article .rtk-help {\n  background: #00265d;\n  color: #fff;\n  border-radius: 6px;\n  padding: 24px 26px;\n  margin: 3em 0 1em;\n}\n.rtk-article .rtk-help p { color: #fff; }\n.rtk-article .rtk-help .rtk-help-title {\n  font-size: 20px;\n  font-weight: 700;\n  margin-bottom: 0.4em;\n}\n.rtk-article .rtk-help a.rtk-button {\n  background: #fff;\n  border-color: #fff;\n  color: #00265d;\n  margin-top: 0.6em;\n}\n.rtk-article .rtk-help a.rtk-button:hover {\n  background: #eef6fc;\n  border-color: #eef6fc;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 3.5em; }\n  .rtk-article h3 { margin-top: 2.2em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout,\n  .rtk-article blockquote.rtk-voc {\n    padding: 14px 16px;\n  }\n  .rtk-article .rtk-cta-links { flex-direction: column; }\n  .rtk-article a.rtk-button { display: block; text-align: center; }\n  .rtk-article .rtk-help { padding: 18px 16px; }\n}\n<\/style>\n\n<div class=\"rtk-article\">\n<h2>\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n\n<details class=\"rtk-faq\">\n<summary><h3>\u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u304c\u771f\u6b63\u54c1\u304b\u3069\u3046\u304b\u306f\u3001\u4f55\u3092\u898b\u3066\u5224\u65ad\u3057\u307e\u3059\u304b\uff1f<\/h3><\/summary>\n<p>\u771f\u6b63\u306a\u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u3067\u306f\u3001\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u306e(\u2212)-(4R)\u914d\u7f6e\u306e\u30b8\u30a2\u30b9\u30c6\u30ec\u30aa\u30de\u30fc\u304c(+)-\u93e1\u50cf\u7570\u6027\u4f53\u3088\u308a\u591a\u304f\u542b\u307e\u308c\u3001\u03b2-\u30b7\u30c8\u30ed\u30cd\u30ed\u30fc\u30eb\u306f(\u2212)-(S)\u4f53\u304c74\uff5e80%\u3092\u5360\u3081\u308b\u3068\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u3089\u304c\u30e9\u30bb\u30df\u4f53\u306b\u306a\u3063\u3066\u3044\u308b\u5834\u5408\u306f\u3001\u771f\u6b63\u54c1\u3067\u306f\u306a\u3044\u3068\u5224\u65ad\u3067\u304d\u307e\u3059\u3002<\/p>\n<\/details>\n\n<details class=\"rtk-faq\">\n<summary><h3>\u30ed\u30fc\u30ba\u6cb9\u3068\u30ed\u30fc\u30ba\u9999\u6599\u3067\u306f\u3001\u5206\u6790\u7d50\u679c\u306b\u3069\u306e\u3088\u3046\u306a\u9055\u3044\u304c\u3042\u308a\u307e\u3057\u305f\u304b\uff1f<\/h3><\/summary>\n<p>\u4eca\u56de\u306e\u30ed\u30fc\u30ba\u6cb9\u3067\u306f4\u7a2e\u306e\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u7570\u6027\u4f53\u304c\u3059\u3079\u3066\u691c\u51fa\u3055\u308c\u307e\u3057\u305f\u304c\u3001\u30ed\u30fc\u30ba\u9999\u6599\u3067\u306f\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u306f\u307e\u3063\u305f\u304f\u691c\u51fa\u3055\u308c\u307e\u305b\u3093\u3067\u3057\u305f\u3002<\/p>\n<\/details>\n\n<h2>\u307e\u3068\u3081<\/h2>\n\n<p>Rt-\u03b2DEXsa\u306f\u307b\u304b\u306e\u30ad\u30e9\u30eb\u30ab\u30e9\u30e0\u3068\u9078\u629e\u6027\u304c\u5927\u304d\u304f\u7570\u306a\u308a\u3001\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u3084\u03b2-\u30b7\u30c8\u30ed\u30cd\u30ed\u30fc\u30eb\u306e\u93e1\u50cf\u7570\u6027\u4f53\u3092\u5206\u96e2\u3067\u304d\u307e\u3059\u3002\u30e9\u30bb\u30df\u4f53\u306e\u6709\u7121\u3084\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u306e\u691c\u51fa\u7d50\u679c\u304b\u3089\u3001\u7cbe\u6cb9\u306e\u771f\u6b63\u6027\u3092\u8a55\u4fa1\u3059\u308b\u624b\u304c\u304b\u308a\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/p>\n\n<div class=\"rtk-callout\">\n<p>\u6b21\u56de\u306f\u3001\u30ad\u30e9\u30eb\u30ab\u30e9\u30e0\u3092500\u56de\u6ce8\u5165\u307e\u3067\u4f7f\u7528\u3057\u305f\u969b\u306e\u6027\u80fd\u306e\u63a8\u79fb\u3092\u691c\u8a3c\u3057\u307e\u3059\u3002<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4626-ja\/chiral-separations-9-lifetime-of-a-chiral-column\">GC\u30ad\u30e9\u30eb\u5206\u67909\uff1a\u30ad\u30e9\u30eb\u30ab\u30e9\u30e0\u306e\u5bff\u547d<\/a>\u3092\u8aad\u3080<\/p>\n<\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u53d6\u308a\u4e0a\u3052\u3066\u307b\u3057\u3044\u30c6\u30fc\u30de\u306a\u3069\u306e\u3054\u8981\u671b\u304c\u3042\u308a\u307e\u3057\u305f\u3089\u3001\u304a\u6c17\u8efd\u306b\u304a\u77e5\u3089\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u30ad\u30e9\u30eb\u30ab\u30e9\u30e0\u306e\u30e9\u30a4\u30f3\u30a2\u30c3\u30d7\uff1a<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13108\">                                \u30ab\u30bf\u30ed\u30b0No. 13108                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Chiral GC Capillary Column, Rt-bDEXsa 30 m, 0.32 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13108\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13109\">                                \u30ab\u30bf\u30ed\u30b0No. 13109                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Chiral GC Capillary Column, Rt-bDEXsa 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13109\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13102\">                                \u30ab\u30bf\u30ed\u30b0No. 13102                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Chiral GC Capillary Column, Rt-bDEXcst 30 m, 0.32 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13102\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13103\">                                \u30ab\u30bf\u30ed\u30b0No. 13103                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Chiral GC Capillary Column, Rt-bDEXcst 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13103\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13100\">                                \u30ab\u30bf\u30ed\u30b0No. 13100                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Chiral GC Capillary Column, Rt-\u03b2DEXm 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13100\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13101\">                                \u30ab\u30bf\u30ed\u30b0No. 13101                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Chiral GC Capillary Column, Rt-\u03b2DEXm 30 m, 0.32 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13101\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13106\">                                \u30ab\u30bf\u30ed\u30b0No. 13106                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Chiral GC Capillary Column, Rt-\u03b2DEXse 30 m, 0.32 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13106\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13107\">                                \u30ab\u30bf\u30ed\u30b0No. 13107                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Chiral GC Capillary Column, Rt-\u03b2DEXse 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13107\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13104\">                                \u30ab\u30bf\u30ed\u30b0No. 13104                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Chiral GC Capillary Column, Rt-\u03b2DEXsm 30 m, 0.32 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13104\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13105\">                                \u30ab\u30bf\u30ed\u30b0No. 13105                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Chiral GC Capillary Column, Rt-\u03b2DEXsm 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13105\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13112\">                                \u30ab\u30bf\u30ed\u30b0No. 13112                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Chiral GC Capillary Column, Rt-gDEXsa 30 m, 0.32 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13112\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13113\">                                \u30ab\u30bf\u30ed\u30b0No. 13113                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Chiral GC Capillary Column, Rt-gDEXsa 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13113\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u4eca\u56de\u306f\u518d\u3073Rt-\u03b2DEXsa\u30ab\u30e9\u30e0\u3092\u53d6\u308a\u4e0a\u3052\u3001\u30ed\u30fc\u30ba\u6cb9\u3068\u9999\u6599\u3078\u306e\u9069\u7528\u4f8b\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002Rt-\u03b2DEXsa\u306f\u3001\u307b\u304b\u306e\u30ad\u30e9\u30eb\u30ab\u30e9\u30e0\u3068\u9078\u629e\u6027\u304c\u5927\u304d\u304f\u7570\u306a\u308a\u307e\u3059\u30021-\u30aa\u30af\u30c6\u30f3-3-\u30aa\u30fc\u30eb\u3001\u30ab\u30eb\u30dc\u30f3\u3001\u30ab\u30f3\u30d5\u30a1\u30fc\u3001\u03b2-\u30b7\u30c8\u30ed\u30cd\u30ed\u30fc\u30eb\u3001\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u3067\u6700\u3082\u826f\u597d\u306a\u5206\u96e2\u304c\u5f97\u3089\u308c\u308b\u305f\u3081\u3001\u7279\u5b9a\u306e\u7cbe\u6cb9\u306e\u5206\u6790\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u3053\u3067\u306f\u3001\u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u3001\u7d14\u6b63\u30ed\u30fc\u30ba\u6cb9\u3001\u30ed\u30fc\u30ba\u9999\u6599\u3092\u53d6\u308a\u4e0a\u3052\u307e\u3059\u3002 \u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\uff5c\u30e9\u30bb\u30df\u4f53\u306e\u691c\u51fa\u306b\u3088\u308b\u771f\u6b63\u6027\u306e\u5224\u5225 \u30bc\u30e9\u30cb\u30a6\u30e0\u306f\u30d0\u30e9\u985e\uff08Rosids\uff09\u306b\u5c5e\u3059\u308b\u690d\u7269\u3067\u3042\u308a\u3001\u305d\u306e\u7cbe\u6cb9\u306e\u7d44\u6210\u306f\u30ed\u30fc\u30ba\u6cb9\u3068\u985e\u4f3c\u3057\u3066\u3044\u307e\u3059\u3002\u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u306e\u30ad\u30e9\u30eb\u6210\u5206\u306b\u306f\u3001cis-\u304a\u3088\u3073trans-\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u3001\u30e1\u30f3\u30c8\u30f3\u3001\u30ea\u30ca\u30ed\u30fc\u30eb\u3001\u03b2-\u30b7\u30c8\u30ed\u30cd\u30ed\u30fc\u30eb\u304c\u3042\u308a\u307e\u3059\u3002Rt-\u03b2DEXsa\u30ab\u30e9\u30e0\u3067\u306f\u3001\u3053\u308c\u3089\u3059\u3079\u3066\u306e\u5316\u5408\u7269\u3067\u30ad\u30e9\u30eb\u5206\u96e2\u304c\u5f97\u3089\u308c\u307e\u3059\u3002 \u771f\u6b63\u306a\u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u3067\u306f\u3001cis-\u304a\u3088\u3073trans-\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u306e(\u2212)-(4R)\u914d\u7f6e\u306e\u30b8\u30a2\u30b9\u30c6\u30ec\u30aa\u30de\u30fc\u304c\u3001(+)-\u93e1\u50cf\u7570\u6027\u4f53\u3088\u308a\u591a\u304f\u542b\u307e\u308c\u307e\u3059\u3002\u307e\u305f\u3001\u03b2-\u30b7\u30c8\u30ed\u30cd\u30ed\u30fc\u30eb\u306e\u93e1\u50cf\u7570\u6027\u4f53\u6bd4\u306f\u3001(\u2212)-(S)\u4f53\u304c74\uff5e80%\u3068\u3055\u308c\u3066\u3044\u307e\u3059\u3002 Figure 1\u306b\u793a\u3059\u3068\u304a\u308a\u3001\u4eca\u56de\u306e\u5e02\u8ca9\u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u3067\u306f\u3001cis-\u304a\u3088\u3073trans-\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u3068\u03b2-\u30b7\u30c8\u30ed\u30cd\u30ed\u30fc\u30eb\u304c\u30e9\u30bb\u30df\u4f53\u3068\u306a\u3063\u3066\u3044\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u30e9\u30bb\u30df\u4f53\u306e\u5b58\u5728\u304b\u3089\u3001\u672c\u7cbe\u6cb9\u306f\u771f\u6b63\u54c1\u3067\u306f\u306a\u3044\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002 Figure 1\uff1aRt-\u03b2DEXsa\u306b\u3088\u308b\u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u306e\u5206\u6790\uff08GC_FF1372\uff09 \u30ed\u30fc\u30ba\u6cb9\u3068\u30ed\u30fc\u30ba\u9999\u6599\uff5c\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u306e\u6709\u7121\u3068\u93e1\u50cf\u7570\u6027\u4f53\u6bd4\u306b\u3088\u308b\u5224\u5225 \u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u3068\u540c\u69d8\u306b\u3001\u30ed\u30fc\u30ba\u6cb9\u306b\u3082\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u3068\u03b2-\u30b7\u30c8\u30ed\u30cd\u30ed\u30fc\u30eb\u304c\u542b\u307e\u308c\u307e\u3059\uff08Figure 2\uff09\u3002\u30e1\u30f3\u30c8\u30f3\u3082\u542b\u307e\u308c\u307e\u3059\u304c\u3001\u305d\u306e\u91cf\u306f\u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u3088\u308a\u5c11\u306a\u304f\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u306e\u30ed\u30fc\u30ba\u6cb9\u30b5\u30f3\u30d7\u30eb\u3067\u306f\u3001\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u306e\u91cf\u3082\u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u3088\u308a\u306f\u308b\u304b\u306b\u5c11\u306a\u304f\u30014\u7a2e\u306e\u7570\u6027\u4f53\u304c\u3059\u3079\u3066\u691c\u51fa\u3055\u308c\u307e\u3057\u305f\u3002 4\u7a2e\u306e\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u7570\u6027\u4f53\u304c\u3059\u3079\u3066\u691c\u51fa\u3055\u308c\u3001\u3055\u3089\u306b\u03b2-\u30b7\u30c8\u30ed\u30cd\u30ed\u30fc\u30eb\u306e\u4e21\u93e1\u50cf\u7570\u6027\u4f53\u304c\u307b\u307c\u540c\u91cf\u5b58\u5728\u3059\u308b\u3053\u3068\u304b\u3089\u3001\u672c\u30b5\u30f3\u30d7\u30eb\u306f\u771f\u6b63\u54c1\u3067\u306f\u306a\u3044\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002 Figure 2\uff1aRt-\u03b2DEXsa\u306b\u3088\u308b\u30ed\u30fc\u30ba\u6cb9\u306e\u5206\u6790\uff08GC_FF1373\uff09 \u30ed\u30fc\u30ba\u9999\u6599\u3067\u306f\u3001\u30ed\u30fc\u30ba\u6cb9\u306e\u4ee3\u8868\u7684\u306a\u6210\u5206\u306e\u4e00\u90e8\u304c\u691c\u51fa\u3055\u308c\u307e\u3057\u305f\u304c\u3001\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u306f\u307e\u3063\u305f\u304f\u691c\u51fa\u3055\u308c\u307e\u305b\u3093\u3067\u3057\u305f\uff08Figure 3\uff09\u3002 Figure 3\uff1aRt-\u03b2DEXsa\u306b\u3088\u308b\u30ed\u30fc\u30ba\u9999\u6599\u306e\u5206\u6790\uff08GC_FF1375\uff09 \u3088\u304f\u3042\u308b\u8cea\u554f \u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u304c\u771f\u6b63\u54c1\u304b\u3069\u3046\u304b\u306f\u3001\u4f55\u3092\u898b\u3066\u5224\u65ad\u3057\u307e\u3059\u304b\uff1f \u771f\u6b63\u306a\u30bc\u30e9\u30cb\u30a6\u30e0\u6cb9\u3067\u306f\u3001\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u306e(\u2212)-(4R)\u914d\u7f6e\u306e\u30b8\u30a2\u30b9\u30c6\u30ec\u30aa\u30de\u30fc\u304c(+)-\u93e1\u50cf\u7570\u6027\u4f53\u3088\u308a\u591a\u304f\u542b\u307e\u308c\u3001\u03b2-\u30b7\u30c8\u30ed\u30cd\u30ed\u30fc\u30eb\u306f(\u2212)-(S)\u4f53\u304c74\uff5e80%\u3092\u5360\u3081\u308b\u3068\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u3089\u304c\u30e9\u30bb\u30df\u4f53\u306b\u306a\u3063\u3066\u3044\u308b\u5834\u5408\u306f\u3001\u771f\u6b63\u54c1\u3067\u306f\u306a\u3044\u3068\u5224\u65ad\u3067\u304d\u307e\u3059\u3002 \u30ed\u30fc\u30ba\u6cb9\u3068\u30ed\u30fc\u30ba\u9999\u6599\u3067\u306f\u3001\u5206\u6790\u7d50\u679c\u306b\u3069\u306e\u3088\u3046\u306a\u9055\u3044\u304c\u3042\u308a\u307e\u3057\u305f\u304b\uff1f \u4eca\u56de\u306e\u30ed\u30fc\u30ba\u6cb9\u3067\u306f4\u7a2e\u306e\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u7570\u6027\u4f53\u304c\u3059\u3079\u3066\u691c\u51fa\u3055\u308c\u307e\u3057\u305f\u304c\u3001\u30ed\u30fc\u30ba\u9999\u6599\u3067\u306f\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u306f\u307e\u3063\u305f\u304f\u691c\u51fa\u3055\u308c\u307e\u305b\u3093\u3067\u3057\u305f\u3002 \u307e\u3068\u3081 Rt-\u03b2DEXsa\u306f\u307b\u304b\u306e\u30ad\u30e9\u30eb\u30ab\u30e9\u30e0\u3068\u9078\u629e\u6027\u304c\u5927\u304d\u304f\u7570\u306a\u308a\u3001\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u3084\u03b2-\u30b7\u30c8\u30ed\u30cd\u30ed\u30fc\u30eb\u306e\u93e1\u50cf\u7570\u6027\u4f53\u3092\u5206\u96e2\u3067\u304d\u307e\u3059\u3002\u30e9\u30bb\u30df\u4f53\u306e\u6709\u7121\u3084\u30ed\u30fc\u30ba\u30aa\u30ad\u30b7\u30c9\u306e\u691c\u51fa\u7d50\u679c\u304b\u3089\u3001\u7cbe\u6cb9\u306e\u771f\u6b63\u6027\u3092\u8a55\u4fa1\u3059\u308b\u624b\u304c\u304b\u308a\u304c\u5f97\u3089\u308c\u307e\u3059\u3002 \u6b21\u56de\u306f\u3001\u30ad\u30e9\u30eb\u30ab\u30e9\u30e0\u3092500\u56de\u6ce8\u5165\u307e\u3067\u4f7f\u7528\u3057\u305f\u969b\u306e\u6027\u80fd\u306e\u63a8\u79fb\u3092\u691c\u8a3c\u3057\u307e\u3059\u3002GC\u30ad\u30e9\u30eb\u5206\u67909\uff1a\u30ad\u30e9\u30eb\u30ab\u30e9\u30e0\u306e\u5bff\u547d\u3092\u8aad\u3080 \u53d6\u308a\u4e0a\u3052\u3066\u307b\u3057\u3044\u30c6\u30fc\u30de\u306a\u3069\u306e\u3054\u8981\u671b\u304c\u3042\u308a\u307e\u3057\u305f\u3089\u3001\u304a\u6c17\u8efd\u306b\u304a\u77e5\u3089\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n","protected":false},"author":50,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[2816],"industries-application":[2263,2274],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2340],"ppma_author":[591],"class_list":["post-105684","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","tag-gc","industries-application-cannabis-ja","industries-application-food-beverage-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"post_tag":[{"value":2816,"label":"GC"}],"industries-application":[{"value":2263,"label":"\u30ab\u30f3\u30ca\u30d3\u30b9"},{"value":2274,"label":"\u98df\u54c1\uff5c\u98f2\u6599"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jana Hepner, PhD","author_link":"https:\/\/discover.restek.com\/ja\/author\/jana-hepner-phd\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":[{"term_id":2816,"name":"GC","slug":"gc","term_group":0,"term_taxonomy_id":2816,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw"}],"authors":[{"term_id":591,"user_id":50,"is_guest":0,"slug":"jana-hepner-phd","display_name":"Jana Hepner, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hepner-jana.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hepner-jana.jpg"},"author_category":"1","first_name":"Jana","last_name":"Hepner","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/105684","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/50"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=105684"}],"version-history":[{"count":25,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/105684\/revisions"}],"predecessor-version":[{"id":106685,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/105684\/revisions\/106685"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=105684"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=105684"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=105684"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=105684"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=105684"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=105684"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=105684"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=105684"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=105684"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}