{"id":3331,"date":"2025-07-31T14:13:54","date_gmt":"2025-07-31T14:13:54","guid":{"rendered":"https:\/\/discover.restek.com\/?p=3331"},"modified":"2025-12-09T00:49:59","modified_gmt":"2025-12-09T00:49:59","slug":"which-fittings-do-i-use-for-which-tubing","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq\/gnot5081\/which-fittings-do-i-use-for-which-tubing","title":{"rendered":"Which fittings do I use for which tubing?"},"content":{"rendered":"\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3395-13-1024x526.jpg\" alt=\"Diagram showing EXP nut, Titanium slotted end and PEEK end of EXP ferrule, and 10-32 female threaded port of column\" class=\"wp-image-3219\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Convention tells us to match fitting material to tubing material: use PEEK fittings with PEEK tubing and use stainless-steel fittings with stainless-steel tubing. The main reason for that is simply system pressure. However, some stainless-steel fittings can be used with PEEK tubing. For example,&nbsp;EXP fittings&nbsp;utilize a titanium\/PEEK hybrid construction and can be used with either PEEK or stainless-steel tubing. However, if inertness is a consideration, stainless-steel fittings should be avoided, and PEEK fittings are a better choice. Please note that PEEK is not recommended for use with some strong acid solutions, such as aqua regia, and it can be affected by halogenated solvents, as well as THF, under certain conditions. Stainless steel is safe for most mobile phase reagents and solvents, but it is less inert, particularly toward mineral acids, bases, and oxidizing agents.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">EXP fittings&nbsp;utilize a titanium\/PEEK hybrid construction and can be used with either PEEK or stainless-steel tubing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Other types of tubing, such as PTFE and Tygon tubing, work well with PEEK or polyethylene (PE) fittings, unions, and adaptors. Many of these fittings are not screw-threaded but rather slip-on because of their use in low-pressure applications. A great example of this is mobile phase delivery in HPLC from bottle\/reservoir to pump. This is a low-pressure delivery (HPLC and UHPLC systems hold high pressures from pumps to the end of the column), and PTFE tubing and PTFE or PE fittings are commonly used.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3395-14.jpg\" alt=\"PEEK union connector\" class=\"wp-image-3225\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">PEEK union connector&nbsp;(<a href=\"https:\/\/www.restek.com\/p\/27715\" target=\"_blank\" rel=\"noopener\">cat.# 27715<\/a>)<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3395-15.jpg\" alt=\"Bluestem glass solvent filter\" class=\"wp-image-3231\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Bluestem glass solvent filter (<a href=\"https:\/\/www.restek.com\/p\/26431\" target=\"_blank\" rel=\"noopener\">cat.# 26431<\/a>) <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Convention tells us to match fitting material to tubing material: use PEEK fittings with PEEK tubing and use stainless-steel fittings with stainless-steel tubing. The main reason for that is simply system pressure. However, some stainless-steel fittings can be used with PEEK tubing. For example,&nbsp;EXP fittings&nbsp;utilize a titanium\/PEEK hybrid construction and can be used with either&#8230;<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[23],"tags":[2682,2701],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-3331","post","type-post","status-publish","format-standard","hentry","category-faq","tag-faq-hplc-and-uhplc","tag-faq-lc-hardware"],"acf":[],"taxonomy_info":{"category":[{"value":23,"label":"FAQ"}],"post_tag":[{"value":2682,"label":"FAQ: HPLC and UHPLC"},{"value":2701,"label":"FAQ: LC Hardware"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":23,"name":"FAQ","slug":"faq","term_group":0,"term_taxonomy_id":23,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":23,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq","category_parent":0}],"tag_info":[{"term_id":2682,"name":"FAQ: HPLC and UHPLC","slug":"faq-hplc-and-uhplc","term_group":0,"term_taxonomy_id":2682,"taxonomy":"post_tag","description":"Browse frequently asked questions for HPLC and UHPLC products.","parent":0,"count":61,"filter":"raw"},{"term_id":2701,"name":"FAQ: LC Hardware","slug":"faq-lc-hardware","term_group":0,"term_taxonomy_id":2701,"taxonomy":"post_tag","description":"Browse frequently asked questions for LC hardware.","parent":0,"count":8,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/3331","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=3331"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/3331\/revisions"}],"predecessor-version":[{"id":71420,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/3331\/revisions\/71420"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=3331"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=3331"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=3331"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=3331"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=3331"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=3331"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=3331"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=3331"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=3331"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}