{"id":39943,"date":"2025-10-07T19:03:30","date_gmt":"2025-10-07T19:03:30","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/method-development-guide-for-novel-psychoactive-substances\/"},"modified":"2026-08-31T09:26:26","modified_gmt":"2026-08-31T09:26:26","slug":"method-development-guide-for-novel-psychoactive-substances","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-zh\/cfar4168\/method-development-guide-for-novel-psychoactive-substances","title":{"rendered":"\u65b0\u7cbe\u795e\u6d3b\u6027\u7269\u8d28\uff08NPS\uff09\u65b9\u6cd5\u5f00\u53d1\u6307\u5357"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">\u5f15\u8a00<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u8fd1\u5e74\u6765\uff0c\u6bd2\u7406\u5b66\u5b9e\u9a8c\u5ba4\u9762\u4e34\u5927\u91cf\u65b0\u7cbe\u795e\u6d3b\u6027\u7269\u8d28\u5feb\u901f\u6d8c\u73b0\u7684\u68c0\u6d4b\u538b\u529b\u3002NPS\u662f\u4e00\u7c7b\u7edf\u79f0\uff0c\u6307\u4ee3\u5404\u7c7b\u672a\u53d7\u7ba1\u5236\u7684\u7269\u8d28\u6216\u5236\u5242\uff0c\u5176\u7814\u53d1\u76ee\u7684\u901a\u5e38\u4e3a\u6a21\u62df\u8fdd\u7981\u53ca\u7ba1\u5236\u836f\u7269\u7684\u836f\u7406\u4f5c\u7528\u3002\u8be5\u7c7b\u7269\u8d28\u56e0\u6682\u672a\u7eb3\u5165\u6cd5\u5f8b\u7ba1\u63a7\u8303\u7574\uff0c\u4e5f\u5e38\u88ab\u79f0\u4f5c \u201c\u5408\u6cd5\u5174\u594b\u5242\u201d\u3002NPS\u6db5\u76d6\u591a\u7c7b\u522b\u7cbe\u795e\u7c7b\u7269\u8d28\uff0c\u5305\u542b\u5174\u594b\u5242\u3001\u963f\u7247\u7c7b\u7269\u8d28\u3001\u5927\u9ebb\u7d20\u3001\u81f4\u5e7b\u5242\u7b49\u591a\u79cd\u54c1\u7c7b\u3002\u90e8\u5206\u6b64\u7c7b\u5316\u5408\u7269\u867d\u88ab\u51a0\u4ee5 \u201c\u65b0\u578b\u201d \u4e4b\u540d\uff0c\u5b9e\u5219\u5e76\u975e\u8fd1\u5e74\u5168\u65b0\u5408\u6210\u3002\u591a\u6570\u5316\u5408\u7269\u65e9\u5e74\u4fbf\u5df2\u5b8c\u6210\u5408\u6210\u5236\u5907\uff0c\u76f8\u5173\u7814\u7a76\u66fe\u63a2\u7d22\u5176\u6f5c\u5728\u836f\u7528\u4ef7\u503c\uff0c\u4f46\u53d7\u5404\u7c7b\u56e0\u7d20\u9650\u5236\u672a\u80fd\u83b7\u6279\u4e0a\u5e02\uff0c\u5982\u4eca\u5374\u518d\u5ea6\u6d41\u5165\u5e02\u573a\uff0c\u6210\u4e3a\u6ee5\u7528\u7c7b\u7269\u8d28\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5c3d\u7ba1NPS\u6682\u4e0d\u53d7\u6cd5\u5f8b\u7ba1\u5236\uff0c\u4f46\u88ab\u666e\u904d\u8ba4\u4e3a\u662f\u4e00\u79cd\u516c\u5171\u5065\u5eb7\u5a01\u80c1\u3002\u8be5\u7c7b\u7269\u8d28\u7684\u6ee5\u7528\u53ef\u5f15\u53d1\u5404\u7c7b\u5065\u5eb7\u635f\u4f24\uff0c\u751a\u81f3\u9020\u6210\u836f\u7269\u8fc7\u91cf\u4e2d\u6bd2\u3002\u7136\u800c\uff0c\u7531\u4e8eNPS\u66f4\u65b0\u8fed\u4ee3\u901f\u5ea6\u6781\u5feb\uff0c\u7edd\u5927\u591a\u6570\u6b64\u7c7b\u7269\u8d28\u7684\u836f\u7406\u4f5c\u7528\u3001\u5b89\u5168\u5242\u91cf\u53ca\u836f\u7269\u95f4\u76f8\u4e92\u4f5c\u7528\u5747\u7f3a\u4e4f\u5b8c\u5584\u7684\u7814\u7a76\u6570\u636e\u652f\u6491\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">NPS\u7684\u6cdb\u6ee5\uff0c\u7ed9\u5f00\u5c55\u6bd2\u7406\u5b66\u68c0\u6d4b\u4e0e\u67e5\u6263\u6bd2\u54c1\u68c0\u9a8c\u5de5\u4f5c\u7684\u5b9e\u9a8c\u5ba4\u5e26\u6765\u4e86\u7279\u6b8a\u96be\u9898\u3002\u4f34\u968fNPS\u79cd\u7c7b\u6301\u7eed\u589e\u52a0\uff0c\u5b9e\u73b0\u8be5\u7c7b\u7269\u8d28\u7684\u68c0\u51fa\u3001\u5b9a\u6027\u4e0e\u5b9a\u91cf\u5206\u6790\u5df2\u6210\u4e3a\u5b9e\u9a8c\u5ba4\u521a\u9700\u3002\u5c3d\u7ba1\u8be5\u76ee\u6807\u660e\u786e\u6e05\u6670\uff0c\u4f46\u591a\u79cd\u56e0\u7d20\u4f1a\u5927\u5e45\u589e\u52a0\u68c0\u6d4b\u5206\u6790\u5de5\u4f5c\u7684\u96be\u5ea6\u3002\u9996\u5148\uff0cNPS\u54c1\u7c7b\u6570\u91cf\u5e9e\u5927\uff0c\u76ee\u524d\u5df2\u9274\u5b9a\u51fa\u6570\u767e\u4e43\u81f3\u4e0a\u5343\u79cd\u76f8\u5173\u5316\u5408\u7269\uff0c\u7ed9\u7b5b\u67e5\u5de5\u4f5c\u9020\u6210\u963b\u788d\u3002\u5176\u6b21\uff0c\u5404\u7c7bNPS\u7684\u6d41\u884c\u5468\u671f\u66f4\u8fed\u901f\u5ea6\u6781\u5feb\uff0c\u5b9e\u9a8c\u5ba4\u96be\u4ee5\u5b9e\u65f6\u638c\u63e1\u5f53\u4e0b\u6d41\u901a\u6cdb\u6ee5\u7684\u76ee\u6807\u7269\u8d28\u3002\u9664\u6b64\u4e4b\u5916\uff0c\u591a\u6570\u8be5\u7c7b\u5316\u5408\u7269\u4e3a\u65b0\u8fd1\u51fa\u73b0\u7269\u8d28\uff0c\u6b64\u524d\u5e76\u672a\u4f5c\u4e3a\u6210\u763e\u6027\u6d88\u9063\u836f\u7269\u6d41\u901a\uff0c\u56e0\u6b64\u5728\u521d\u6b21\u9001\u68c0\u6837\u54c1\u65f6\u96be\u4ee5\u5feb\u901f\u8bc6\u522b\u3002\u5728\u5b9e\u9645\u6848\u4ef6\u6837\u672c\u4e2d\uff0c\u67d0\u79cd\u836f\u7269\u5f80\u5f80\u5728\u5b9e\u9a8c\u5ba4\u4eba\u5458\u5c1a\u672a\u5bdf\u89c9\u65f6\u4fbf\u5df2\u5b58\u5728\uff0c\u8fd9\u610f\u5473\u7740\u68c0\u6d4b\u5de5\u4f5c\u4ece\u4e00\u5f00\u59cb\u5c31\u51e0\u4e4e\u603b\u662f\u5904\u4e8e\u6ede\u540e\u72b6\u6001\u3002\u9488\u5bf9NPS\u5f00\u53d1\u5168\u65b0\u68c0\u6d4b\u65b9\u6cd5\uff0c\u8fd8\u5b58\u5728\u5468\u671f\u957f\u3001\u6280\u672f\u96be\u5ea6\u9ad8\u3001\u7814\u53d1\u6210\u672c\u9ad8\u6602\u7b49\u95ee\u9898\u3002\u7efc\u5408\u5404\u7c7b\u5236\u7ea6\u6761\u4ef6\uff0cNPS\u68c0\u6d4b\u65b9\u6cd5\u7684\u5f00\u53d1\u662f\u4e00\u9879\u7e41\u91cd\u8270\u5de8\u7684\u5de5\u4f5c\u3002\u5145\u5206\u660e\u6670NPS\u7ed9\u5b9e\u9a8c\u5ba4\u5e26\u6765\u7684\u5404\u7c7b\u96be\u70b9\uff0c\u6709\u52a9\u4e8e\u79d1\u7814\u4eba\u5458\u9488\u5bf9\u6027\u5f00\u5c55\u8be5\u7c7b\u7269\u8d28\u68c0\u6d4b\u65b9\u6cd5\u7684\u7814\u53d1\u5de5\u4f5c\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u6587\u5c06\u68b3\u7406NPS\u68c0\u6d4b\u8fc7\u7a0b\u4e2d\u9700\u517c\u987e\u7684\u5b9e\u64cd\u8981\u70b9\u4e0e\u5206\u6790\u6280\u672f\u8981\u70b9\uff0c\u5e76\u9488\u5bf9\u5176\u4e2d\u4e00\u7c7b\u963f\u7247\u7c7bNPS\u5c55\u5f00\u68c0\u6d4b\u65b9\u6cd5\u5f00\u53d1\u63a2\u8ba8\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>NPS \u7684\u5b9e\u7528\u4e0e\u5206\u6790\u6ce8\u610f\u4e8b\u9879<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><em><strong>\u5316\u5b66\u7ed3\u6784<\/strong><\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">NPS \u6db5\u76d6\u591a\u79cd\u6bd2\u54c1\u7c7b\u522b\u4e0b\u7684\u5927\u91cf\u5316\u5408\u7269\uff0c\u5404\u7c7b\u7269\u8d28\u5316\u5b66\u7ed3\u6784\u5dee\u5f02\u663e\u8457\uff0c\u5bf9\u5e94\u7684\u7406\u5316\u6027\u8d28\u4e5f\u56e0\u6b64\u5927\u76f8\u5f84\u5ead\u3002\u4e0e\u4e4b\u76f8\u5bf9\uff0c\u540c\u4e00\u4e9a\u7c7b\u4e0b\u7684\u6bd2\u54c1\u591a\u4e3a\u5f7c\u6b64\u7684\u5316\u5b66\u7c7b\u4f3c\u7269\uff0c\u5206\u5b50\u7ed3\u6784\u5177\u5907\u9ad8\u5ea6\u76f8\u4f3c\u6027\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u82ac\u592a\u5c3c\uff08Fentanyl\uff09\u4e8e 1960 \u5e74\u9996\u6b21\u4eba\u5de5\u5408\u6210\uff0c\u65e9\u671f\u5e7f\u6cdb\u5e94\u7528\u4e8e\u4e34\u5e8a\u9547\u75db\u6cbb\u7597\u3002\u4f46\u8be5\u7269\u8d28\u540e\u7eed\u9010\u6e10\u6cdb\u6ee5\u6210\u4e3a\u4e3b\u6d41\u6ee5\u7528\u6bd2\u54c1\uff0c\u5f15\u53d1\u5927\u91cf\u836f\u7269\u8fc7\u91cf\u81f4\u6b7b\u6848\u4f8b\u3002\u975e\u6cd5\u82ac\u592a\u5c3c\u5236\u9020\u8005\u5f00\u59cb\u5236\u9020\u7ed3\u6784\u7ecf\u8fc7\u4fee\u9970\u7684\u82ac\u592a\u5c3c\u7c7b\u4f3c\u7269\uff0c\u4ee5\u89c4\u907f\u7ba1\u5236\u3002\u4e59\u9170\u82ac\u592a\u5c3c\uff08Acetyl fentanyl\uff09\u5c31\u662f\u8fd9\u7c7b\u7c7b\u4f3c\u7269\u4e4b\u4e00\u3002\u82ac\u592a\u5c3c\u542b\u6709\u82ef\u4e19\u9170\u80fa\u57fa\u56e2\uff0c\u800c\u4e59\u9170\u82ac\u592a\u5c3c\u542b\u6709\u82ef\u4e59\u9170\u80fa\u57fa\u56e2\uff0c\u4e8c\u8005\u5206\u5c5e\u4e0d\u540c\u5316\u5408\u7269\uff0c\u4f46\u7ed3\u6784\u4e0a\u6781\u4e3a\u76f8\u4f3c\u3002\u8fd9\u5bf9\u4f9d\u8d56\u5316\u5b66\u4e0e\u7ed3\u6784\u5dee\u5f02\u6765\u6709\u6548\u9274\u522b\u548c\u5206\u79bb\u5316\u5408\u7269\u7684\u5206\u6790\u6280\u672f\uff08\u5982 LC-MS\/MS\uff09\u5177\u6709\u91cd\u8981\u5f71\u54cd\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728\u8fdb\u884c NPS \u65b9\u6cd5\u5f00\u53d1\u65f6\uff0c\u5173\u6ce8\u5f02\u6784\u4f53\u548c\u540c\u91cf\u5f02\u4f4d\u7d20\u7b49\u95ee\u9898\u81f3\u5173\u91cd\u8981\uff0c\u6709\u52a9\u4e8e\u4e3a\u6709\u6548\u5206\u6790\u9009\u62e9\u6700\u4f73\u5206\u6790\u6761\u4ef6\uff0c\u5305\u62ec\u8272\u8c31\u67f1\u3001\u6d41\u52a8\u76f8\u7ec4\u6210\u3001\u68c0\u6d4b\u5668\u3001\u6e29\u5ea6\u53ca\u5176\u4ed6\u56e0\u7d20\u7684\u9009\u62e9\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em><strong>\u6d41\u884c\u6001\u52bf<\/strong><\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f85\u7b5b\u67e5\u5316\u5408\u7269\u79cd\u7c7b\u7e41\u591a\uff0c\u4e14\u5404\u7c7bNPS\u5728\u975e\u6cd5\u6bd2\u54c1\u5e02\u573a\u4e2d\u7684\u6d41\u901a\u5360\u6bd4\u5b58\u5728\u4e0d\u786e\u5b9a\u6027\uff0c\u5b9e\u9a8c\u5ba4\u96be\u4ee5\u5224\u5b9a\u9700\u91cd\u70b9\u68c0\u6d4b\u7684NPS\uff0c\u76f8\u5173\u7b5b\u9009\u5de5\u4f5c\u5b58\u5728\u8f83\u5927\u76f2\u76ee\u6027\u3002\u76ee\u524d\u5df2\u6709\u6743\u5a01\u4fe1\u606f\u6e20\u9053\u53ef\u4e3a\u5b9e\u9a8c\u5ba4\u63d0\u4f9b\u53c2\u8003\uff0c\u4fbf\u4e8e\u79d1\u7814\u4eba\u5458\u660e\u786e\u5404\u9636\u6bb5\u4f18\u5148\u7b5b\u67e5\u7684\u76ee\u6807\u7269\u8d28\u3002\u6cd5\u533b\u79d1\u5b66\u7814\u7a76\u4e0e\u6559\u80b2\u4e2d\u5fc3\uff08CFSRE\uff09\u3001\u7f8e\u56fd\u7f09\u6bd2\u5c40\uff08DEA\uff09\u4ee5\u53ca\u56fd\u5bb6\u6cd5\u533b\u5b9e\u9a8c\u5ba4\u4fe1\u606f\u7cfb\u7edf\uff08NFLIS\uff09\u5747\u63d0\u4f9b\u6709\u5173\u65b0 NPS \u53d1\u73b0\u60c5\u51b5\u53ca\u7279\u5b9a\u5316\u5408\u7269\u68c0\u51fa\u9891\u7387\u7684\u4fe1\u606f\u3002\u5728\u5f00\u5c55 NPS \u65b9\u6cd5\u5f00\u53d1\u65f6\u67e5\u9605\u8fd9\u4e9b\u8d44\u6e90\uff0c\u6709\u52a9\u4e8e\u786e\u4fdd\u5c06\u6700\u91cd\u8981\u7684\u5316\u5408\u7269\u7eb3\u5165\u5206\u6790\u7269\u6e05\u5355\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em><strong>\u57fa\u8d28\u8003\u91cf<\/strong><\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0e\u6240\u6709\u6bd2\u7406\u5b66\u6216\u836f\u7269\u5316\u5b66\u5206\u6790\u4e00\u81f4\uff0c\u5728\u4e3a NPS \u5f00\u53d1\u65b9\u6cd5\u65f6\u5e94\u8003\u8651\u6837\u54c1\u7684\u57fa\u8d28\u3002\u5982\u679c\u5bf9\u751f\u7269\u4f53\u6db2\u8fdb\u884c\u6bd2\u7406\u5b66\u68c0\u6d4b\uff0c\u5219\u6bcd\u4f53\u5316\u5408\u7269\u4ee5\u53ca\u4efb\u4f55\u5df2\u77e5\u4ee3\u8c22\u7269\u90fd\u53ef\u80fd\u88ab\u7eb3\u5165\u5206\u6790\u7269\u6e05\u5355\u3002\u90e8\u5206\u4ee3\u8c22\u4ea7\u7269\u5728\u751f\u7269\u4f53\u5185\u7684\u7559\u5b58\u5468\u671f\u957f\u4e8e\u6bcd\u4f53\u836f\u7269\uff0c\u5373\u4fbf\u6837\u54c1\u4e2d\u5df2\u65e0\u6cd5\u68c0\u51fa\u6bcd\u4f53\u836f\u7269\uff0c\u4ecd\u53ef\u68c0\u51fa\u5bf9\u5e94\u4ee3\u8c22\u7269\u3002\u56e0\u6b64\u5728\u751f\u7269\u4f53\u6db2\u5206\u6790\u4e2d\uff0c\u4ee3\u8c22\u7269\u5bf9\u4e8e\u786e\u8ba4\u7528\u836f\u81f3\u5173\u91cd\u8981\u3002\u82e5\u68c0\u6d4b\u65b9\u6cd5\u5f00\u53d1\u9762\u5411\u67e5\u6263\u6bd2\u54c1\u7269\u8bc1\u5b9a\u6027\u573a\u666f\uff0c\u4ee3\u8c22\u4ea7\u7269\u7684\u68c0\u6d4b\u4ef7\u503c\u5219\u8fdc\u4f4e\u4e8e\u751f\u7269\u4f53\u6db2\u68c0\u9a8c\u573a\u666f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8bbe\u8ba1\u7c7b\u82ef\u4e8c\u6c2e\u44ec\u7c7b\u836f\u7269\u6c2f\u785d\u5511\u4ed1\u5c31\u662f\u4e00\u4e2a\u4f8b\u5b50\u3002\u8be5\u7269\u8d28\u4f5c\u4e3a\u4e00\u79cd\u65b0\u578b\u7cbe\u795e\u6d3b\u6027\u7269\u8d28\uff0c\u4e8e2014\u5e74\u9996\u6b21\u51fa\u73b0\u5728\u975e\u6cd5\u836f\u7269\u4f9b\u5e94\u4e2d\u3002\u76ee\u524d\u5df2\u77e5\u5176\u4ee3\u8c22\u7269\u4e3a8-\u6c28\u57fa\u6c2f\u785d\u5511\u4ed1\u3002\u5bf9\u4e8e\u7f34\u83b7\u7684\u836f\u7269\u7269\u8bc1\u9274\u5b9a\uff0c\u4ec5\u68c0\u6d4b\u6c2f\u785d\u5511\u4ed1\u7684\u6bcd\u4f53\u5316\u5408\u7269\u5373\u53ef\u6ee1\u8db3\u8981\u6c42\uff1b\u4f46\u5982\u679c\u662f\u5bf9\u6b7b\u540e\u8840\u6db2\u6837\u672c\u8fdb\u884c\u6bd2\u7406\u5b66\u5206\u6790\uff0c\u5219\u5fc5\u987b\u540c\u65f6\u68c0\u6d4b\u6c2f\u785d\u5511\u4ed1\u53ca\u5176\u4ee3\u8c22\u72698-\u6c28\u57fa\u6c2f\u785d\u5511\u4ed1\u3002\u7531\u6b64\u53ef\u89c1\uff0c\u5728\u6784\u5efa\u65b0\u578b\u7cbe\u795e\u6d3b\u6027\u7269\u8d28\u68c0\u6d4b\u6e05\u5355\u65f6\uff0c\u5145\u5206\u8003\u8651\u68c0\u6750\u57fa\u8d28\u4ee5\u53ca\u4ee3\u8c22\u7269\u5206\u6790\u7684\u5fc5\u8981\u6027\uff0c\u662f\u81f3\u5173\u91cd\u8981\u7684\u4e00\u73af\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u91c7\u7528 LC-MS\/MS \u5206\u6790\u5c3c\u79e6\u7c7b\uff08Nitazenes\uff09\u7684\u65b9\u6cd5\u5f00\u53d1<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><em><strong>\u80cc\u666f<\/strong><\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u82ef\u5e76\u54aa\u5511\u7c7b\u963f\u7247\uff08Benzimidazole-opioids\uff09\uff0c\u4fd7\u79f0\u5c3c\u79e6\u7c7b\uff08nitazenes\uff09\uff0c\u662f\u8fd1\u5e74\u975e\u6cd5\u6bd2\u54c1\u5e02\u573a\u4e2d\u65b0\u51fa\u73b0\u7684\u5408\u6210\u963f\u7247\u7c7b\u5b50\u7c7b\u3002\u8be5\u7c7b\u5316\u5408\u7269\u836f\u6548\u5f3a\u5ea6\u5b58\u5728\u5dee\u5f02\uff0c\u4f46\u836f\u7406\u6d3b\u6027\u4e0e\u5176\u4f59\u963f\u7247\u7c7b\u7269\u8d28\u76f8\u8fd1\uff0c\u80fd\u591f\u5f15\u53d1\u547c\u5438\u6291\u5236\u4f5c\u7528\u3002\u81ea\u8be5\u7c7b\u7269\u8d28\u91cd\u65b0\u6d41\u5165\u5e02\u9762\u540e\uff0c\u73b0\u5df2\u9274\u522b\u51fa\u591a\u79cd\u7ed3\u6784\u7c7b\u4f3c\u7269\u3002\u6b64\u7c7b\u5316\u5408\u7269\u4ee5\u82ef\u5e76\u54aa\u5511\u73af\u4e3a\u6838\u5fc3\u9aa8\u67b6\uff0c\u5176 1 \u53f7\u4f4d\u8fde\u63a5\u4e59\u80fa\u57fa\u56e2\uff0c2 \u53f7\u4f4d\u8fde\u63a5\u82c4\u57fa\uff1b\u5404\u7c7b\u5c3c\u79e6\u884d\u751f\u7269\u5747\u901a\u8fc7\u5bf9\u8be5\u57fa\u7840\u5206\u5b50\u9aa8\u67b6\u8fdb\u884c\u7ed3\u6784\u4fee\u9970\u5f97\u5230\uff0c\u4e14\u540e\u7eed\u4ecd\u4f1a\u4e0d\u65ad\u6d8c\u73b0\u5168\u65b0\u7ed3\u6784\u7c7b\u4f3c\u7269\u3002<\/p>\n\n\n\n<div class=\"wp-block-columns has-border-color is-layout-flex wp-container-core-columns-is-layout-f3249208 wp-block-columns-is-layout-flex\" style=\"border-color:#dee2e6;border-width:1px;padding-top:10px;padding-right:20px;padding-bottom:10px;padding-left:20px\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u56fe 1\uff1a\u5c3c\u79e6\u7c7b\u57fa\u672c\u7ed3\u6784\u4e0e\u5df2\u77e5\u7ed3\u6784\u7c7b\u4f3c\u7269 [1]<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-style:none;border-width:0px\"><tbody><tr><td rowspan=\"11\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-01.jpg\" alt=\"Basic nitazene structure\" title=\"-\"><\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;<\/td><td class=\"has-text-align-center\" data-align=\"center\">R<sub>1<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">R<sub>2<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">R<sub>3<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">R<sub>4<\/sub><\/td><\/tr><tr><td>metonitazene<\/td><td class=\"has-text-align-center\" data-align=\"center\">NO<sub>2<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">OCH<sub>3<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">CH<sub>2<\/sub>CH<sub>3<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">CH<sub>2<\/sub>CH<sub>3<\/sub><\/td><\/tr><tr><td>metodesnitazene<\/td><td class=\"has-text-align-center\" data-align=\"center\">H<\/td><td class=\"has-text-align-center\" data-align=\"center\">OCH<sub>3<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">CH<sub>2CH3<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">CH<sub>2CH3<\/sub><\/td><\/tr><tr><td>etonitazene<\/td><td class=\"has-text-align-center\" data-align=\"center\">NO<sub>2<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">OCH<sub>2CH3<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">CH<sub>2CH3<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">CH<sub>2CH3<\/sub><\/td><\/tr><tr><td>etodesnitazene<\/td><td class=\"has-text-align-center\" data-align=\"center\">H<\/td><td class=\"has-text-align-center\" data-align=\"center\">OCH<sub>2<\/sub>CH<sub>3<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">CH<sub>2<\/sub>CH<sub>3<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">CH<sub>2<\/sub>CH<sub>3<\/sub><\/td><\/tr><tr><td>protonitazene<\/td><td class=\"has-text-align-center\" data-align=\"center\">NO<sub>2<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">OCH<sub>2<\/sub>CH<sub>2<\/sub>CH<sub>3<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">CH<sub>2<\/sub>CH<sub>3<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">CH<sub>2<\/sub>CH<sub>3<\/sub><\/td><\/tr><tr><td>butonitazene<\/td><td class=\"has-text-align-center\" data-align=\"center\">NO<sub>2<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">OCH<sub>2<\/sub>CH<sub>2<\/sub>CH<sub>2<\/sub>CH<sub>3<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">CH<sub>2<\/sub>CH<sub>3<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">CH<sub>2<\/sub>CH<sub>3<\/sub><\/td><\/tr><tr><td>isotonitazene<\/td><td class=\"has-text-align-center\" data-align=\"center\">NO<sub>2<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">OCH(CH<sub>3<\/sub>)<sub>2<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">CH<sub>2<\/sub>CH<sub>3<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">CH<sub>2<\/sub>CH<sub>3<\/sub><\/td><\/tr><tr><td>clonitazene<\/td><td class=\"has-text-align-center\" data-align=\"center\">NO<sub>2<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">CI<\/td><td class=\"has-text-align-center\" data-align=\"center\">CH<sub>2<\/sub>CH<sub>3<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">CH<sub>2<\/sub>CH<sub>3<\/sub><\/td><\/tr><tr><td>flunitazene<\/td><td class=\"has-text-align-center\" data-align=\"center\">NO<sub>2<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">F<\/td><td class=\"has-text-align-center\" data-align=\"center\">CH<sub>2<\/sub>CH<sub>3<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">CH<sub>2<\/sub>CH<sub>3<\/sub><\/td><\/tr><tr><td>etonitazepyne<\/td><td class=\"has-text-align-center\" data-align=\"center\">NO<sub>2<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">OCH<sub>2<\/sub>CH<sub>3<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">-CH<sub>2<\/sub>CH<sub>2<\/sub>CH<sub>2<\/sub>CH<sub>2<\/sub>&#8211;<\/td><\/tr><tr><td>&nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">etonitazepipne<\/td><td class=\"has-text-align-center\" data-align=\"center\">NO<sub>2<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\">OCH<sub>2<\/sub>CH<sub>3<\/sub><\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">-CH<sub>2<\/sub>CH<sub>2<\/sub>CH<sub>2<\/sub>CH<sub>2<\/sub>CH<sub>2<\/sub>&#8211;<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><br>\u8be5\u7c7b\u7ed3\u6784\u836f\u7269\u7684\u9996\u6b21\u5408\u6210\u53ef\u8ffd\u6eaf\u81f3 20 \u4e16\u7eaa 50 \u5e74\u4ee3\uff0c\u76f8\u5173\u5408\u6210\u521d\u8877\u4e3a\u63a2\u7a76\u5176\u9547\u75db\u836f\u7406\u4f5c\u7528\uff0c\u5f7c\u65f6\u8be5\u7c7b\u836f\u7269\u5c1a\u672a\u83b7\u6279\u5e94\u7528\u4e8e\u4eba\u4f53\u4e34\u5e8a \u00a0[1]\u3002\u5728\u6b64\u540e\u7684\u6570\u5341\u5e74\u95f4\uff0c\u5176\u4e2d\u4e00\u4e9b\u5316\u5408\u7269\u51fa\u73b0\u5728\u975e\u6cd5\u836f\u7269\u5e02\u573a\uff0c<strong>\u5f02\u4e19\u6258\u5c3c\u79e6<\/strong>\u4e8e 2019 \u5e74\u521d\u5728\u7f8e\u56fd\u5883\u5185\u88ab\u53d1\u73b0 [2]\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2020 \u5e74\uff0cDEA \u5ba3\u5e03\u8ba1\u5212\u5c06 <strong>\u5f02\u4e19\u6258\u5c3c\u79e6<\/strong>\u5217\u5165\u300a\u53d7\u7ba1\u5236\u7269\u8d28\u6cd5\u300b\u9644\u8868 I\uff0c\u4ee5\u51cf\u5c11\u76f8\u5173\u7528\u836f\u8fc7\u91cf\u6b7b\u4ea1\u4eba\u6570 [2]\u3002\u5c3d\u7ba1\u5982\u6b64\uff0c\u8fd1\u5e74\u6765\u65b0\u7684\u5c3c\u79e6\u7c7b\u4f3c\u7269\u4ecd\u4e0d\u65ad\u6e17\u5165\u975e\u6cd5\u836f\u7269\u5e02\u573a\u3002\u76f4\u5230\u8fd1\u671f\uff0c\u88ab\u9274\u5b9a\u51fa\u7684\u5927\u591a\u6570\u7c7b\u4f3c\u7269\u4ecd\u5c5e\u4e8e\u539f\u59cb\u4e13\u5229\u6587\u732e\u6240\u8bb0\u8f7d\u7684\u8303\u56f4\u3002\u8bf8\u5982 <strong>N-\u5421\u54af\u70f7\u57fa\u4f9d\u6258\u5c3c\u79e6<\/strong> \u7b49\u5c3c\u79e6\u7c7b\u4f3c\u7269\u7684\u51fa\u73b0\u6807\u5fd7\u7740\u8be5\u5b50\u7c7b\u8fdb\u5165\u4e86\u65b0\u9636\u6bb5\u3002\u6b64\u7c7b\u7269\u8d28\u5e76\u672a\u88ab\u65e9\u671f\u7814\u7a76\u6587\u732e\u6536\u5f55\uff0c\u5c5e\u4e8e\u771f\u6b63\u610f\u4e49\u4e0a\u65b0\u8fd1\u5408\u6210\u7684NPS [2]\u3002\u8fd9\u4e00\u73b0\u8c61\u8868\u660e\uff0c\u8be5\u7c7b\u836f\u7269\u5e76\u4e0d\u4f1a\u5728\u77ed\u671f\u5185\u88ab\u53d6\u7f14\u6d88\u4ea1\uff0c\u53cd\u800c\u4f1a\u6301\u7eed\u53d1\u751f\u7ed3\u6784\u6f14\u53d8\u5e76\u6108\u53d1\u6cdb\u6ee5\u3002\u8fd9\u7c7b\u5316\u5408\u7269\u4e5f\u5370\u8bc1\u4e86\u65e2\u5f80\u5408\u6210\u836f\u7269\u53ef\u4f9d\u6258NPS\u7684\u5f62\u5f0f\u518d\u5ea6\u6d41\u901a\uff0c\u5e76\u4e0d\u65ad\u884d\u751f\u51fa\u7ed3\u6784\u540c\u6e90\u7684\u65b0\u578b\u7c7b\u4f3c\u7269\u3002<\/p>\n\n\n\n<div class=\"wp-block-columns has-border-color is-layout-flex wp-container-core-columns-is-layout-f3249208 wp-block-columns-is-layout-flex\" style=\"border-color:#dee2e6;border-width:1px;padding-top:10px;padding-right:20px;padding-bottom:10px;padding-left:20px\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><em><strong>\u56fe 2\uff1a\u5c3c\u79e6\u7c7b\u51fa\u73b0\u7684\u65f6\u95f4\u7ebf<\/strong><\/em><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"309\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-02-1024x309.jpg\" alt=\"\" class=\"wp-image-19264\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-02-1024x309.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-02-300x91.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-02-768x232.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-02-1536x463.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-02.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u7814\u7a76\u5f3a\u70c8\u5efa\u8bae\uff0c\u5f00\u5c55\u6bd2\u7406\u5b66\u4e0e\u836f\u7269\u5316\u5b66\u5206\u6790\u7684\u5b9e\u9a8c\u5ba4\u5c06\u5c3c\u79e6\u7c7b\u5316\u5408\u7269\u7eb3\u5165\u5e38\u89c4\u68c0\u6d4b\u7b5b\u67e5\u8303\u56f4\u3002\u672c\u6587\u540e\u7eed\u90e8\u5206\u5c06\u8ba8\u8bba\u4e00\u7ec4\u5c3c\u79e6\u7c7b\u5316\u5408\u7269\u7684\u65b9\u6cd5\u5f00\u53d1\u8fc7\u7a0b\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em><strong>\u5236\u5b9a\u5206\u6790\u7269\u6e05\u5355<\/strong><\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u76ee\u524d\u5df2\u77e5\u7684\u5c3c\u79e6\u7c7b\uff08nitazene\uff09\u7c7b\u4f3c\u7269\u6570\u91cf\u76f8\u5f53\u53ef\u89c2\uff0c\u4f46\u5e76\u975e\u6240\u6709\u7c7b\u4f3c\u7269\u90fd\u5df2\u5728\u975e\u6cd5\u836f\u7269\u5e02\u573a\u4e2d\u5e7f\u6cdb\u6d41\u901a\u3002\u4e00\u79cd\u7b56\u7565\u662f\u5efa\u7acb\u80fd\u8986\u76d6\u6240\u6709\u5df2\u77e5\u5c3c\u79e6\u7c7b\u5316\u5408\u7269\u7684\u68c0\u6d4b\u65b9\u6cd5\uff0c\u4f46\u8fd9\u6837\u4f1a\u5bfc\u81f4\u5206\u6790\u65f6\u95f4\u5ef6\u957f\uff0c\u5e76\u4e14\u9700\u4e3a\u6807\u51c6\u54c1\u6295\u5165\u66f4\u591a\u7ecf\u8d39\uff0c\u800c\u5176\u4e2d\u5f88\u591a\u5316\u5408\u7269\u5728\u5b9e\u9645\u6848\u4ef6\u6837\u54c1\u4e2d\u51fa\u73b0\u7684\u53ef\u80fd\u6027\u6781\u4f4e\u3002\u66f4\u9ad8\u6548\u7684\u505a\u6cd5\u662f\u53c2\u8003\u524d\u8ff0\u6587\u732e\u8d44\u6e90\uff0c\u4e86\u89e3\u5f53\u524d\u54ea\u4e9b\u5c3c\u79e6\u7c7b\u5316\u5408\u7269\u6700\u4e3a\u5e38\u89c1\uff0c\u6709\u9488\u5bf9\u6027\u5730\u5efa\u7acb\u65b9\u6cd5\u3002\u622a\u81f3\u672c\u6587\u64b0\u5199\u65f6\uff0c\u4ee5\u4e0b\u5c3c\u79e6\u7c7b\u88ab\u5217\u4e3a\u68c0\u6d4b\u8303\u56f4\u63a8\u8350\u9879\uff1aN-\u53bb\u4e59\u57fa\u5f02\u6258\u5c3c\u79e6\u3001\u5f02\u4e19\u6258\u5c3c\u79e6\u3001N-\u5421\u54af\u70f7\u57fa\u4f9d\u6258\u5c3c\u79e6\u3001N-\u5421\u54af\u70f7\u57fa\u4e19\u6258\u5c3c\u79e6\u3001N-\u5421\u54af\u70f7\u57fa\u7532\u6258\u5c3c\u79e6\u3001\u4e19\u6258\u5c3c\u79e6\u548c\u5f02\u4e01\u6258\u5c3c\u79e6[3]\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6240\u5f00\u53d1\u65b9\u6cd5\u7684\u9884\u671f\u7528\u9014\u662f\u5c3f\u6db2\u6837\u54c1\u7684\u6bd2\u7406\u5b66\u5206\u6790\u3002\u591a\u79cd\u5c3c\u79e6\u7c7b\u836f\u7269\u7684\u901a\u7528\u4ee3\u8c22\u7269 <strong>4-\u7f9f\u57fa\u5c3c\u79e6<\/strong>\u5df2\u5728\u5305\u62ec\u8840\u6db2\u548c\u5c3f\u6db2\u5728\u5185\u7684\u591a\u79cd\u4f53\u6db2\u4e2d\u88ab\u68c0\u51fa [2]\u3002\u68c0\u51fa\u8be5\u4ee3\u8c22\u7269\u53ef\u6307\u793a\u5c3c\u79e6\u7c7b\u7684\u4f7f\u7528\uff0c\u56e0\u6b64\u4e5f\u88ab\u52a0\u5165\u5206\u6790\u7269\u6e05\u5355\u3002<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-border-color is-layout-flow wp-block-column-is-layout-flow\" style=\"border-color:#dee2e6;border-width:1px;padding-top:10px;padding-right:20px;padding-bottom:10px;padding-left:20px\">\n<p class=\"wp-block-paragraph\"><strong>\u56fe 3\uff1a\u7528\u4e8e\u65b9\u6cd5\u5f00\u53d1\u7684\u5c3c\u79e6\u7c7b\u6e05\u5355<\/strong><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03a.jpg\" alt=\"\" class=\"wp-image-19270\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03a.jpg 500w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03a-300x300.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03a-150x150.jpg 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Isotonitazene<br>(410.5 g\/mol)<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03e.jpg\" alt=\"\" class=\"wp-image-19294\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03e.jpg 500w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03e-300x300.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03e-150x150.jpg 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>N<\/em>-Pyrrolidino etonitazepyne<br>(394.5 g\/mol)<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03b.jpg\" alt=\"\" class=\"wp-image-19276\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03b.jpg 500w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03b-300x300.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03b-150x150.jpg 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Protonitazene<br>(410.5 g\/mol)<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03f.jpg\" alt=\"\" class=\"wp-image-19300\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03f.jpg 500w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03f-300x300.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03f-150x150.jpg 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>N<\/em>-Pyrrolidino metonitazene<br>(380.4 g\/mol)<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03c.jpg\" alt=\"\" class=\"wp-image-19282\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03c.jpg 500w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03c-300x300.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03c-150x150.jpg 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>iso<\/em>-Butonitazene<br>(424.5 g\/mol)<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03g.jpg\" alt=\"\" class=\"wp-image-19306\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03g.jpg 500w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03g-300x300.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03g-150x150.jpg 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>N<\/em>-Pyrrolidino protonitazene<br>(408.5 g\/mol)<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03d.jpg\" alt=\"\" class=\"wp-image-19288\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03d.jpg 500w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03d-300x300.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03d-150x150.jpg 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>N<\/em>-Desethyl-isotonitazene<br>(382.5 g\/mol)<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03h.jpg\" alt=\"\" class=\"wp-image-19312\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03h.jpg 500w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03h-300x300.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-03h-150x150.jpg 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">4\u2032-hydroxy Nitazene<br>(368.4 g\/mol)<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><em><br><strong>HPLC \u8272\u8c31\u67f1\u4e0e\u6d41\u52a8\u76f8\u9009\u62e9<\/strong><\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">HPLC \u8272\u8c31\u67f1\u54c1\u7c7b\u7e41\u591a\uff0c\u7b5b\u9009\u9002\u914d\u65b0\u5206\u6790\u65b9\u6cd5\u7684\u8272\u8c31\u67f1\u5b58\u5728\u8f83\u5927\u9009\u62e9\u96be\u5ea6\u3002C18 \u4e0e\u8054\u82ef\uff08Biphenyl\uff09\u56fa\u5b9a\u76f8\u4e3a\u836f\u7269\u68c0\u6d4b\u5b9e\u9a8c\u5ba4\u7684\u4e3b\u6d41\u9009\u578b\uff0c\u53ef\u4f5c\u4e3a\u8be5\u7c7b\u5206\u6790\u573a\u666f\u7684\u4f18\u5148\u56fa\u5b9a\u76f8\u3002\u7edd\u5927\u591a\u6570\u7ba1\u5236\u7cbe\u795e\u836f\u54c1\u5747\u53ef\u901a\u8fc7 C18\u3001\u8054\u82ef\u578b\u8272\u8c31\u67f1\u9ad8\u6548\u5206\u6790\uff0c\u4e8c\u8005\u5404\u5177\u4f18\u52bf\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u56fa\u5b9a\u76f8\u7b5b\u9009\u8fc7\u7a0b\u4e2d\u9700\u7efc\u5408\u8003\u91cf\u76ee\u6807\u5316\u5408\u7269\u7684\u5206\u5b50\u7ed3\u6784\u4e0e\u7406\u5316\u6027\u8d28\u3002\u82e5\u5f85\u6d4b\u7ec4\u5206\u5305\u542b\u540c\u5206\u5f02\u6784\u4f53\uff0c\u5408\u9002\u7684\u8272\u8c31\u67f1\u662f\u5b9e\u73b0\u5f02\u6784\u4f53\u5bf9\u6709\u6548\u5206\u79bb\u3001\u907f\u514d\u4e8c\u8005\u5171\u6d41\u51fa\u7684\u5173\u952e\u3002\u5c31\u672c\u6b21\u65b9\u6cd5\u5f00\u53d1\u6240\u9009\u7684\u5c3c\u79e6\u7c7b\u800c\u8a00\uff0c\u5168\u90e8\u516b\u79cd\u5316\u5408\u7269\u7ed3\u6784\u6781\u4e3a\u76f8\u4f3c\uff0c\u5e76\u5305\u542b\u4e00\u5bf9\u5f02\u6784\u4f53\u3002\u5f02\u4e19\u6258\u5c3c\u79e6\u548c\u4e19\u6258\u5c3c\u79e6 \u4e92\u4e3a\u5f02\u6784\u4f53\uff0c\u4e8c\u8005\u4ec5\u5728\u82c4\u57fa\u90e8\u5206\u5bf9\u4f4d\u7684\u53d6\u4ee3\u4e0a\u5b58\u5728\u7ed3\u6784\u5dee\u5f02\u3002\u9274\u4e8e\u5404\u76ee\u6807\u5f85\u6d4b\u7269\u7ed3\u6784\u76f8\u4f3c\u5ea6\u6781\u9ad8\uff0c\u9009\u7528\u53ef\u63d0\u4f9b\u5145\u8db3\u5206\u79bb\u5ea6\u7684\u8272\u8c31\u67f1\u5177\u6709\u91cd\u8981\u610f\u4e49\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Raptor Biphenyl \u8272\u8c31\u67f1\u662f\u5206\u79bb\u6b64\u7c7b\u96be\u5206\u79bb\u5316\u5408\u7269\u7684\u7406\u60f3\u9009\u62e9\u3002\u8be5\u67f1\u91c7\u7528\u6838\u58f3\u9897\u7c92\u6280\u672f\u4ee5\u83b7\u5f97\u9ad8\u67f1\u6548\uff0c\u5e76\u56e0\u589e\u5f3a\u7684 \u03c0-\u03c0 \u76f8\u4e92\u4f5c\u7528\u800c\u5728\u96be\u5206\u79bb\u573a\u5408\u63d0\u4f9b\u66f4\u9ad8\u7684\u9009\u62e9\u6027\u3002\u672c\u65b9\u6cd5\u5f00\u53d1\u9009\u7528\u4e86 Raptor Biphenyl 50 x 2.1 mm, 2.7 \u00b5m \u8272\u8c31\u67f1\uff08\u8d27\u53f79309A52\uff09\u3002\u4e3a\u4fdd\u62a4\u8272\u8c31\u67f1\u514d\u53d7\u5c3f\u6db2\u57fa\u8d28\u4e2d\u9897\u7c92\u7269\u6216\u6c61\u67d3\u7269\u7684\u5f71\u54cd\uff0c\u4f7f\u7528\u4e86 Raptor Biphenyl EXP \u4fdd\u62a4\u67f1\u82af 5 x 2.1 mm, 2.7 \u00b5m\uff08\u8d27\u53f7 9309A0252\uff0c\u9700\u642d\u914dEXP\u4fdd\u62a4\u67f1\u5957\u4f7f\u7528\uff0c\u67f1\u5957\u8d27\u53f725808\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7532\u9187\u548c\u4e59\u8148\u90fd\u662f HPLC \u4e2d\u5e38\u7528\u7684\u6709\u673a\u76f8\uff0c\u672c\u65b9\u6cd5\u5bf9\u4e8c\u8005\u5747\u8fdb\u884c\u4e86\u8003\u5bdf\u3002\u5982\u524d\u6240\u8ff0\uff0c\u03c0-\u03c0 \u76f8\u4e92\u4f5c\u7528\u6709\u52a9\u4e8e\u8054\u82ef\u76f8\u5b9e\u73b0\u66f4\u4f73\u7684\u5206\u79bb\u3002\u7532\u9187\u7ed3\u6784\u4e2d\u4e0d\u542b \u03c0 \u7535\u5b50\uff0c\u56e0\u6b64\u5f53\u5176\u4f5c\u4e3a\u6709\u673a\u6d41\u52a8\u76f8\u4e0e\u8054\u82ef\u56fa\u5b9a\u76f8\u8272\u8c31\u67f1\u914d\u5408\u4f7f\u7528\u65f6\uff0c\u53ef\u4f7f\u56fa\u5b9a\u76f8\u7684 \u03c0-\u03c0 \u76f8\u4e92\u4f5c\u7528\u5f97\u4ee5\u53d1\u751f\uff0c\u4ece\u800c\u589e\u5f3a\u5206\u79bb\uff1b\u76f8\u53cd\uff0c\u4e59\u8148\u7ed3\u6784\u4e2d\u542b\u6709\u5e26 \u03c0 \u7535\u5b50\u7684<strong>\u2014CN<\/strong>\uff0c\u4f1a\u524a\u5f31\u8054\u82ef\u56fa\u5b9a\u76f8\u7684 \u03c0-\u03c0 \u76f8\u4e92\u4f5c\u7528\u3002\u4e3a\u6b64\uff0c\u6d41\u52a8\u76f8 A \u9009\u7528\u6c34\u3001\u6d41\u52a8\u76f8 B \u9009\u7528\u7532\u9187\uff0c\u4e8c\u8005\u5747\u4ee5 0.1% \u7532\u9178\u9178\u5316\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em><strong>\u65b9\u6cd5\u5f00\u53d1\u4e0e\u4f18\u5316<\/strong><\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728 Shimadzu 8045 LC-MS\/MS \u4e0a\u5bf9\u6bcf\u79cd\u5206\u6790\u7269\u7684 MRM \u79bb\u5b50\u5bf9\u8fdb\u884c\u4e86\u4f18\u5316\uff0c\u8be6\u89c1\u4e0b\u8868\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8868 I\uff1a\u5c3c\u79e6\u7c7b\u5316\u5408\u7269\u7684 MRM \u79bb\u5b50\u5bf9\uff08ESI+\uff09<\/strong><\/p>\n\n\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td class=\"has-text-align-center\" style=\"text-align: left;\" data-align=\"center\"><strong>Peak<\/strong><\/td>\n<td class=\"has-text-align-center\" data-align=\"center\"><strong>Ion Mode<\/strong><\/td>\n<td class=\"has-text-align-center\" data-align=\"center\"><strong>Precursor<\/strong><\/td>\n<td class=\"has-text-align-center\" data-align=\"center\"><strong>Product Ion<\/strong><\/td>\n<td class=\"has-text-align-center\" data-align=\"center\"><strong>Product Ion<\/strong><\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td class=\"has-text-align-center\" style=\"text-align: left;\" data-align=\"center\">4\u2032-hydroxy Nitazene<\/td>\n<td class=\"has-text-align-center\" style=\"background-color: #ecf0f1;\" rowspan=\"8\" data-align=\"center\">ESI+<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">369.1<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">100.2<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">72.3<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" style=\"text-align: left;\" data-align=\"center\"><em>iso<\/em>-Butonitazene<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">425.2<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">100.3<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">72.2<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td class=\"has-text-align-center\" style=\"text-align: left;\" data-align=\"center\">Isotonitazene<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">411.0<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">100.2<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">72.2<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" style=\"text-align: left;\" data-align=\"center\"><em>N<\/em>-Desethyl isotonitazene<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">383.0<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">72.3<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">312.2<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td class=\"has-text-align-center\" style=\"text-align: left;\" data-align=\"center\"><em>N<\/em>-Pyrrolidino etonitazene<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">395.0<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">98.3<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">56.1<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" style=\"text-align: left;\" data-align=\"center\"><em>N<\/em>-Pyrrolidino metonitazene<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">381.0<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">98.2<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">121.2<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td class=\"has-text-align-center\" style=\"text-align: left;\" data-align=\"center\"><em>N<\/em>-Pyrrolidino protonitazene<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">409.0<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">98.3<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">56.2<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" style=\"text-align: left;\" data-align=\"center\">Protonitazene<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">411.0<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">100.2<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">72.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<p class=\"wp-block-paragraph\"><br>\u4f7f\u7528\u4e0a\u8ff0\u8272\u8c31\u67f1\u3001\u6d41\u52a8\u76f8\u548c MRM \u79bb\u5b50\u5bf9\u5f00\u53d1\u4e86\u4e00\u79cd LC-MS\/MS \u65b9\u6cd5\u3002\u5bf9\u6d17\u8131\u68af\u5ea6\u3001\u6d41\u901f\u548c\u67f1\u6e29\u8fdb\u884c\u4e86\u4f18\u5316\uff0c\u4ee5\u83b7\u5f97\u5206\u6790\u7269\u7684\u6700\u4f73\u5206\u79bb\u3002\u65b9\u6cd5\u4f18\u5316\u5b8c\u6210\u540e\uff0c\u5c06\u5206\u6790\u7269\u52a0\u6807\u4e8e\u7a7a\u767d\u5c3f\u6db2\u4e2d\uff0c\u4ee5\u786e\u8ba4\u4e0d\u5b58\u5728\u57fa\u8d28\u5e72\u6270\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em><strong>\u6700\u7ec8\u65b9\u6cd5<\/strong><\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u6700\u7ec8\u65b9\u6cd5\u53c2\u6570\u3001\u4ee3\u8868\u6027\u8c31\u56fe\u548c\u5206\u6790\u7269\u4fdd\u7559\u65f6\u95f4\u5982\u4e0b\u6240\u793a\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8868 II\uff1a\u5c3c\u79e6\u7c7b LC-MS\/MS \u65b9\u6cd5\u53c2\u6570<\/strong><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<p class=\"wp-block-paragraph\"><strong>\u8272\u8c31\u67f1:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4fdd\u62a4\u67f1:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6d41\u52a8\u76f8 A:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6d41\u52a8\u76f8 B:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6d41\u901f:<\/strong><\/p>\n\n\n\n<div style=\"height:2px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u68af\u5ea6\u7a0b\u5e8f:<\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"wp-block-paragraph\">Raptor Biphenyl 50 x 2.1 mm, 2.7 \u00b5m (cat.# 9309A52)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Raptor Biphenyl EXP \u4fdd\u62a4\u67f1\u82af 5 x 2.1 mm, 2.7 \u00b5m\uff08cat.# 9309A0252\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6c34\u4e2d 0.1% \u7532\u9178<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7532\u9187\u4e2d 0.1% \u7532\u9178<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"padding-bottom:0px\">1.0 mL\/min<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-6b01c2ec wp-block-columns-is-layout-flex\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:20%\">\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>\u65f6\u95f4 (min)<\/strong><\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">0.00<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">3.50<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">4.25<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">5.00<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">5.50<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">6.00<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:20%\">\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>%A<\/strong><\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">72<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">50<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">0<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">0<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">72<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">72<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:20%\">\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>%B<\/strong><\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">28<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">50<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">100<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">100<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">28<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">28<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<p class=\"wp-block-paragraph\"><strong>\u67f1\u6e29:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8fdb\u6837\u4f53\u79ef:<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u7a00\u91ca\u5242:<\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"wp-block-paragraph\">40 \u00b0C<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">10 \u00b5L<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6c34\u4e2d 0.1% \u7532\u9178\uff08MPA\uff09<\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><em><strong>\u56fe 4\uff1a\u6240\u5f00\u53d1\u7684\u5c3c\u79e6\u7c7b\u5206\u6790\u65b9\u6cd5\u2014\u2014\u5c3f\u6db2\u57fa\u8d28\u4e2d\u7684\u4ee3\u8868\u6027\u8c31\u56fe<\/strong><\/em><\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0805.png\" alt=\"Nitazenes in Urine on Raptor Biphenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0805<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A0252<\/li><li>9309A52<\/li><li>21143<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>biphenyl column<\/li><li>nitazenes<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0805.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><strong><br>\u8868 III\uff1a\u5206\u6790\u7269\u4fdd\u7559\u65f6\u95f4<\/strong><\/p>\n\n\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td class=\"has-text-align-center\" style=\"text-align: left;\" data-align=\"center\"><strong>Analyte #<\/strong><\/td>\n<td class=\"has-text-align-center\" style=\"text-align: center;\" data-align=\"center\"><strong>Analyte<\/strong><\/td>\n<td class=\"has-text-align-center\" data-align=\"center\"><strong>Retention Time (min)<\/strong><\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td class=\"has-text-align-center\" style=\"text-align: center;\" data-align=\"center\">1<\/td>\n<td class=\"has-text-align-center\" style=\"text-align: center;\" data-align=\"center\">4\u2032-hydroxy Nitazene<\/td>\n<td class=\"has-text-align-center\" style=\"text-align: center;\" data-align=\"center\">0.94<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" style=\"text-align: center;\" data-align=\"center\">2<\/td>\n<td class=\"has-text-align-center\" style=\"text-align: center;\" data-align=\"center\"><em>N<\/em>-Pyrrolidino metonitazene<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">2.03<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td class=\"has-text-align-center\" style=\"text-align: center;\" data-align=\"center\">3<\/td>\n<td class=\"has-text-align-center\" style=\"text-align: center;\" data-align=\"center\"><em>N<\/em>-Pyrrolidino etonitazene<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">2.69<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" style=\"text-align: center;\" data-align=\"center\">4<\/td>\n<td class=\"has-text-align-center\" style=\"text-align: center;\" data-align=\"center\"><em>N<\/em>-Desethyl isotonitazene<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">2.94<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td class=\"has-text-align-center\" style=\"text-align: center;\" data-align=\"center\">5<\/td>\n<td class=\"has-text-align-center\" style=\"text-align: center;\" data-align=\"center\">Isotonitazene<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">3.36<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" style=\"text-align: center;\" data-align=\"center\">6<\/td>\n<td class=\"has-text-align-center\" style=\"text-align: center;\" data-align=\"center\"><em>N<\/em>-Pyrrolidino protonitazene<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">3.53<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td class=\"has-text-align-center\" style=\"text-align: center;\" data-align=\"center\">7<\/td>\n<td class=\"has-text-align-center\" style=\"text-align: center;\" data-align=\"center\">Protonitazene<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">3.67<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" style=\"text-align: center;\" data-align=\"center\">8<\/td>\n<td class=\"has-text-align-center\" style=\"text-align: center;\" data-align=\"center\"><em>iso<\/em>-Butonitazene<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">\u00a04.12<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<p class=\"wp-block-paragraph\"><br>\u672c\u7814\u7a76\u6240\u5efa\u7acb\u7684\u6700\u7ec8\u68c0\u6d4b\u65b9\u6cd5\u603b\u8fd0\u884c\u65f6\u957f\u4e3a\u516d\u5206\u949f\u3002\u8be5\u65b9\u6cd5\u6210\u529f\u5206\u79bb\u4e86\u5168\u90e8\u516b\u79cd\u5c3c\u79e6\u7c7b\u5316\u5408\u7269\uff0c\u5305\u62ec\u90a3\u5bf9\u5f02\u6784\u4f53\u3002\u867d\u7136\u9274\u5b9a\u51fa\u4e00\u5904\u5c3f\u6db2\u5e72\u6270\uff0c\u4f46\u5176\u4e0e\u6240\u6709\u76ee\u6807\u5206\u6790\u7269\u5747\u5b9e\u73b0\u4e86\u826f\u597d\u5206\u79bb\u3002\u6240\u6709\u5206\u6790\u7269\u5747\u5728\u4e94\u5206\u949f\u5185\u6d17\u8131\uff0c\u672b\u5c3e\u53e6\u6709\u4e00\u5206\u949f\u7684\u67f1\u518d\u5e73\u8861\u65f6\u95f4\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6240\u5f00\u53d1\u7684\u65b9\u6cd5\u5feb\u901f\u6709\u6548\uff0c\u53ef\u5728\u516d\u5206\u949f\u5185\u5b8c\u6210\u516b\u79cd\u5c3c\u79e6\u7c7b\u5316\u5408\u7269\u7684\u5206\u6790\u3002\u6240\u6709\u5206\u6790\u7269\uff08\u5305\u62ec\u4e00\u5bf9\u5173\u952e\u7ec4\u5206\uff09\u5747\u5f97\u5230\u5145\u5206\u5206\u79bb\u3002\u8be5\u65b9\u6cd5\u975e\u5e38\u9002\u5408\u542b\u5c3c\u79e6\u7c7b\u5316\u5408\u7269\u6837\u54c1\u7684\u6bd2\u7406\u5b66\u6216\u836f\u7269\u5316\u5b66\u5206\u6790\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u501f\u52a9 Pro EZLC \u8c31\u56fe\u6a21\u62df\u8f6f\u4ef6\u7cbe\u7b80 NPS \u65b9\u6cd5\u5f00\u53d1<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u65b9\u6cd5\u5f00\u53d1\u5de5\u4f5c\u8017\u65f6\u957f\u3001\u6210\u672c\u9ad8\uff0c\u8fd8\u4f1a\u5360\u7528\u4eea\u5668\u673a\u65f6\u4e0e\u4eba\u529b\u7b49\u8d44\u6e90\u3002\u518d\u52a0\u4e0a NPS \u5316\u5408\u7269\u6240\u5e26\u6765\u7684\u7d27\u8feb\u6027\u548c\u4e0d\u786e\u5b9a\u6027\uff0c\u65b9\u6cd5\u5f00\u53d1\u5c24\u4e3a\u7e41\u91cd\u3002Pro EZLC \u662f\u4e00\u6b3e\u865a\u62df\u6db2\u76f8\u8272\u8c31\u6a21\u62df\u8f6f\u4ef6\uff0c\u53ef\u7528\u4e8e\u5f00\u53d1\u548c\u4f18\u5316\u6db2\u76f8\u65b9\u6cd5\uff0c\u800c\u65e0\u9700\u5728\u5b9e\u9a8c\u5ba4\u6295\u5165\u5b9e\u9645\u64cd\u4f5c\u65f6\u95f4\u3002Pro EZLC \u8f6f\u4ef6\u53ef\u7528\u4e8e\u6bd4\u8f83\u56fa\u5b9a\u76f8\u3001\u8272\u8c31\u67f1\u5c3a\u5bf8\u3001\u6d41\u52a8\u76f8\u53ca\u5176\u4ed6\u5f71\u54cd\u5206\u79bb\u7684\u53c2\u6570 [4]\u3002\u5176\u201cDrugs of Abuse\u201d\uff08\u6ee5\u7528\u836f\u7269\uff09\u5316\u5408\u7269\u5e93\u5305\u542b\u6700\u65b0\u7684 NPS \u6e05\u5355\uff0c\u5176\u4e2d\u5c31\u6709\u4e0a\u6587\u8ba8\u8bba\u7684\u5c3c\u79e6\u7c7b\u5316\u5408\u7269\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5c3d\u7ba1\u4e0d\u540c\u4eea\u5668\u4e4b\u95f4\u7684\u4fdd\u7559\u65f6\u95f4\u9884\u8ba1\u4f1a\u5b58\u5728\u4e00\u4e9b\u5dee\u5f02\uff0c\u4f46 Pro EZLC \u8f6f\u4ef6\u80fd\u591f\u51c6\u786e\u9884\u6d4b\u4fdd\u7559\u65f6\u95f4\u3002\u4e3a\u5c55\u793a\u9884\u6d4b\u503c\u4e0e\u5b9e\u6d4b\u503c\u7684\u63a5\u8fd1\u7a0b\u5ea6\uff0c\u5bf9\u6240\u5f00\u53d1\u7684\u5c3c\u79e6\u7c7b\u65b9\u6cd5\u8fdb\u884c\u4e86\u6a21\u62df\uff0c\u5e76\u5c06\u5b9e\u6d4b\u4fdd\u7559\u65f6\u95f4\u4e0e\u9884\u671f\u4fdd\u7559\u65f6\u95f4\u8fdb\u884c\u4e86\u6bd4\u8f83\u3002<\/p>\n\n\n\n<div class=\"wp-block-columns has-border-color is-layout-flex wp-container-core-columns-is-layout-b6d01450 wp-block-columns-is-layout-flex\" style=\"border-color:#dee2e6;border-width:1px;padding-top:10px;padding-right:20px;padding-bottom:10px;padding-left:20px\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><em><strong>\u56fe 5\uff1a\u7531 Pro EZLC \u8f6f\u4ef6\u751f\u6210\u7684\u5c3c\u79e6\u7c7b\u65b9\u6cd5\u6a21\u62df\u8c31\u56fe<\/strong><\/em><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"381\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-05-1024x381.jpg\" alt=\"\" class=\"wp-image-19318\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-05-1024x381.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-05-300x112.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-05-768x286.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-05-1536x572.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAR4168-05.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><br>\u8868 IV\uff1aPro EZLC \u9884\u6d4b\u7684\u5c3c\u79e6\u7c7b\u65b9\u6cd5\u4fdd\u7559\u65f6\u95f4\u4e0e\u5cf0\u6807\u6ce8<\/strong><\/p>\n\n\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td>\u00a0<\/td>\n<td><strong>Analyte<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>t<sub>R<\/sub> (min)<\/strong><\/td>\n<td><strong>R<sub>S<\/sub><\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Peak Width (min)<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Exit %B<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Mode<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Precursor Ion<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Quantifier Product Ion<\/strong><\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>1<\/td>\n<td>4\u2032-hydroxy Nitazene<\/td>\n<td style=\"text-align: center;\">0.90<\/td>\n<td>\u00a0<\/td>\n<td style=\"text-align: center;\">0.064<\/td>\n<td style=\"text-align: center;\">30.5<\/td>\n<td style=\"text-align: center;\">+<\/td>\n<td style=\"text-align: center;\">369.1<\/td>\n<td style=\"text-align: center;\">100.2<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td><em>N<\/em>-Pyrrolidino metonitazene<\/td>\n<td style=\"text-align: center;\">2.14<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">0.076<\/td>\n<td style=\"text-align: center;\">38.2<\/td>\n<td style=\"text-align: center;\">+<\/td>\n<td style=\"text-align: center;\">381.0<\/td>\n<td style=\"text-align: center;\">98.2<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>3<\/td>\n<td><em>N<\/em>-Pyrrolidino etonitazene<\/td>\n<td style=\"text-align: center;\">2.81<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">0.077<\/td>\n<td style=\"text-align: center;\">42.4<\/td>\n<td style=\"text-align: center;\">+<\/td>\n<td style=\"text-align: center;\">395.0<\/td>\n<td style=\"text-align: center;\">98.3<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td><em>N<\/em>-Desethyl isotonitazene<\/td>\n<td style=\"text-align: center;\">3.09<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">0.076<\/td>\n<td style=\"text-align: center;\">44.1<\/td>\n<td style=\"text-align: center;\">+<\/td>\n<td style=\"text-align: center;\">383.0<\/td>\n<td style=\"text-align: center;\">72.3<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>5<\/td>\n<td>Isotonitazene<\/td>\n<td style=\"text-align: center;\">3.58<\/td>\n<td style=\"text-align: center;\">4.7<\/td>\n<td style=\"text-align: center;\">0.074<\/td>\n<td style=\"text-align: center;\">47.2<\/td>\n<td style=\"text-align: center;\">+<\/td>\n<td style=\"text-align: center;\">411.0<\/td>\n<td style=\"text-align: center;\">100.2<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td><em>N<\/em>-Pyrrolidino protonitazene<\/td>\n<td style=\"text-align: center;\">3.70<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">0.075<\/td>\n<td style=\"text-align: center;\">48.0<\/td>\n<td style=\"text-align: center;\">+<\/td>\n<td style=\"text-align: center;\">409.0<\/td>\n<td style=\"text-align: center;\">98.3<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>7<\/td>\n<td>Protonitazene<\/td>\n<td style=\"text-align: center;\">3.92<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">0.072<\/td>\n<td style=\"text-align: center;\">49.3<\/td>\n<td style=\"text-align: center;\">+<\/td>\n<td style=\"text-align: center;\">411.1<\/td>\n<td style=\"text-align: center;\">100.3<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td><em>iso<\/em>-Butonitazene<\/td>\n<td style=\"text-align: center;\">4.23<\/td>\n<td style=\"text-align: center;\">\u00a0<\/td>\n<td style=\"text-align: center;\">0.036<\/td>\n<td style=\"text-align: center;\">62.4<\/td>\n<td style=\"text-align: center;\">+<\/td>\n<td style=\"text-align: center;\">425.2<\/td>\n<td style=\"text-align: center;\">100.3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<p class=\"wp-block-paragraph\"><strong><br>\u8868 V\uff1aPro EZLC \u8f6f\u4ef6\u9884\u6d4b\uff08\u9884\u671f\uff09\u4fdd\u7559\u65f6\u95f4\u4e0e\u89c2\u6d4b\u4fdd\u7559\u65f6\u95f4\u7684\u6bd4\u8f83<\/strong><\/p>\n\n\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td style=\"text-align: center;\"><strong>Peak #<\/strong><\/td>\n<td style=\"text-align: left;\"><strong>Analyte<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Expected t<sub>R<\/sub> (min)<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Observed t<sub>R<\/sub> (min)<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Difference (sec)<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>% Difference<\/strong><\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td><strong>1<\/strong><\/td>\n<td>4\u2032-hydroxy Nitazene<\/td>\n<td style=\"text-align: center;\">0.90<\/td>\n<td style=\"text-align: center;\">0.94<\/td>\n<td style=\"text-align: center;\">2.4<\/td>\n<td style=\"text-align: center;\">4.44%<\/td>\n<\/tr>\n<tr>\n<td><strong>2<\/strong><\/td>\n<td><em>N<\/em>-Pyrrolidino metonitazene<\/td>\n<td style=\"text-align: center;\">2.14<\/td>\n<td style=\"text-align: center;\">2.03<\/td>\n<td style=\"text-align: center;\">6.6<\/td>\n<td style=\"text-align: center;\">5.14%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td><strong>3<\/strong><\/td>\n<td><em>N<\/em>-Pyrrolidino etonitazene<\/td>\n<td style=\"text-align: center;\">2.81<\/td>\n<td style=\"text-align: center;\">2.69<\/td>\n<td style=\"text-align: center;\">7.2<\/td>\n<td style=\"text-align: center;\">4.27%<\/td>\n<\/tr>\n<tr>\n<td><strong>4<\/strong><\/td>\n<td><em>N<\/em>-Desethyl isotonitazene<\/td>\n<td style=\"text-align: center;\">3.09<\/td>\n<td style=\"text-align: center;\">2.94<\/td>\n<td style=\"text-align: center;\">9.0<\/td>\n<td style=\"text-align: center;\">4.85%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td><strong>5<\/strong><\/td>\n<td>Isotonitazene<\/td>\n<td style=\"text-align: center;\">3.58<\/td>\n<td style=\"text-align: center;\">3.36<\/td>\n<td style=\"text-align: center;\">13.2<\/td>\n<td style=\"text-align: center;\">6.14%<\/td>\n<\/tr>\n<tr>\n<td><strong>6<\/strong><\/td>\n<td style=\"text-align: left;\"><em>N<\/em>-Pyrrolidino protonitazene<\/td>\n<td style=\"text-align: center;\">3.70<\/td>\n<td style=\"text-align: center;\">3.53<\/td>\n<td style=\"text-align: center;\">10.2<\/td>\n<td style=\"text-align: center;\">4.59%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td><strong>7<\/strong><\/td>\n<td>Protonitazene<\/td>\n<td style=\"text-align: center;\">3.92<\/td>\n<td style=\"text-align: center;\">3.67<\/td>\n<td style=\"text-align: center;\">15.0<\/td>\n<td style=\"text-align: center;\">6.37%<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>8<\/strong><\/td>\n<td style=\"text-align: left;\"><em>iso<\/em>-Butonitazene<\/td>\n<td style=\"text-align: center;\">4.23<\/td>\n<td style=\"text-align: center;\">4.12<\/td>\n<td style=\"text-align: center;\">6.6<\/td>\n<td style=\"text-align: center;\">2.60%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<p class=\"wp-block-paragraph\">\u5bf9\u6bd4\u7ed3\u679c\u663e\u793a\uff0cPro EZLC \u8f6f\u4ef6\u751f\u6210\u7684\u8c31\u56fe\u4e0e\u5b9e\u9a8c\u6570\u636e\u9ad8\u5ea6\u543b\u5408\u3002\u6240\u6709\u5206\u6790\u7269\u7684\u4fdd\u7559\u65f6\u95f4\u5dee\u503c\u5747\u226415 s\uff0c\u5e73\u5747\u76f8\u5bf9\u504f\u5dee\u4e3a 4.80%\u3002\u8f6f\u4ef6\u6a21\u62df\u7ed3\u679c\u4e0e\u4eea\u5668\u5b9e\u6d4b\u7ed3\u679c\u7684\u7ec4\u5206\u51fa\u5cf0\u987a\u5e8f\u3001\u5206\u79bb\u5ea6\uff08\u542b\u540c\u5206\u5f02\u6784\u4f53\u5206\u79bb\u6548\u679c\uff09\u4fdd\u6301\u4e00\u81f4\u3002Pro EZLC \u8272\u8c31\u6a21\u62df\u8f6f\u4ef6\u5b9e\u7528\u6027\u8f83\u5f3a\uff0c\u53ef\u7f29\u77edNPS\u68c0\u6d4b\u65b9\u6cd5\u7684\u5f00\u53d1\u5468\u671f\uff0c\u5e76\u7b80\u5316\u76f8\u5173\u7814\u53d1\u6d41\u7a0b\u3002<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u53c2\u8003\u6587\u732e<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Drug Enforcement Administration, Drug &amp; Chemical Evaluation Section, Benzimidazole-opioids, (November 2022)&nbsp;<a href=\"https:\/\/www.deadiversion.usdoj.gov\/drug_chem_info\/benzimidazole-opioids.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.deadiversion.usdoj.gov\/drug_chem_info\/benzimidazole-opioids.pdf<\/a><\/li>\n\n\n\n<li>S. Walton, et al., A forward-thinking approach to addressing the new synthetic opioid 2-benzylbenzimidazole nitazene analogs by liquid chromatography\u2013tandem quadrupole mass spec\u00adtrometry (LC\u2013QQQ-MS), J. Toxicol. 46 (3), Oxford UP (2021) 221\u201331. <a href=\"https:\/\/doi.org\/10.1093\/jat\/bkab117\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1093\/jat\/bkab117<\/a>.<\/li>\n\n\n\n<li>Center of Forensic Science Research &amp; Education, Recommended scope for NPS testing in the United States: Q2 2022 (2022) <a href=\"https:\/\/www.cfsre.org\/images\/scoperecommendations\/Q2-2022-NPS-Scope-Recommendations-NPS-Discovery-072522.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.cfsre.org\/images\/scoperecommendations\/Q2-2022-NPS-Scope-Recommendations-NPS-Discovery-072522.pdf<\/a>.<\/li>\n\n\n\n<li>Restek Corporation, Pro EZLC software simplifies LC method development, Video,&nbsp;<a href=\"https:\/\/www.restek.com\/videos\/pro-ezlc-software-simplifies-lc-method-development\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.restek.com\/videos\/pro-ezlc-software-simplifies-lc-method-development<\/a>.<\/li>\n<\/ol>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A52\">                                \u30ab\u30bf\u30ed\u30b0No. 9309A52                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Biphenyl, 2.7 \u00b5m, 50 x 2.1 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A52\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A0252\">                                \u30ab\u30bf\u30ed\u30b0No. 9309A0252                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Biphenyl EXP Guard Column Cartridge, 2.7 \u00b5m, 5 x 2.1 mm, 3-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A0252\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25808\">                                \u30ab\u30bf\u30ed\u30b0No. 25808                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">EXP Direct Connect Holder for EXP Guard Cartridges, Includes Fitting &amp; Ferrules<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25808\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>The rise of novel psychoactive substances (NPS) has created a unique challenge for laboratories performing toxicology or seized drug analysis. In this article, consideration will be outlined, both practical and analytical, when working with NPS.<\/p>\n","protected":false},"author":13,"featured_media":6457,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[786],"tags":[],"industries-application":[2194,2195],"post-badge":[],"resource-type":[],"product-library":[2427,2409,2434],"resource-technique":[2310,2361],"ppma_author":[432],"class_list":["post-39943","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-zh","industries-application-forensics-zh","industries-application-forensics-toxicology-zh","product-library-lc-columns-zh","product-library-liquid-chromatography-products-zh","product-library-tools-organization-zh","resource-technique-liquid-chromatography-zh","resource-technique-ms-ms-zh"],"acf":[],"taxonomy_info":{"category":[{"value":786,"label":"\u6587\u7ae0"}],"industries-application":[{"value":2194,"label":"\u53f8\u6cd5\u9274\u5b9a"},{"value":2195,"label":"\u6cd5\u533b\u6bd2\u7406\u5b66"}],"product-library":[{"value":2427,"label":"LC\u8272\u8c31\u67f1"},{"value":2409,"label":"\u6db2\u76f8\u8272\u8c31\u76f8\u5173\u4ea7\u54c1"},{"value":2434,"label":"\u5de5\u5177\u548c\u6536\u7eb3"}],"resource-technique":[{"value":2310,"label":"\u6db2\u76f8\u8272\u8c31"},{"value":2361,"label":"MS\/MS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-CFAR4168-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Haley Berkland, MS","author_link":"https:\/\/discover.restek.com\/ja\/author\/haley-berkland-ms\/"},"comment_info":0,"category_info":[{"term_id":786,"name":"\u6587\u7ae0","slug":"articles-zh","term_group":0,"term_taxonomy_id":786,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":786,"category_count":510,"category_description":"","cat_name":"\u6587\u7ae0","category_nicename":"articles-zh","category_parent":0}],"tag_info":false,"authors":[{"term_id":432,"user_id":13,"is_guest":0,"slug":"haley-berkland-ms","display_name":"Haley Berkland, MS","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg"},"author_category":"1","first_name":"Haley","last_name":"Berkland","user_url":"https:\/\/www.linkedin.com\/in\/haley-berkland-60b66517b\/","job_title":"LC Applications Scientist","description":"Haley is an LC applications scientist at Restek. She attended Duquesne University, receiving her bachelor's degree in biochemistry and a master's degree in forensic science and law. As a graduate student, she performed research on the detection of drugs of abuse in vitreous humor by LC-MS\/MS. Before joining Restek in 2023, Haley spent four years working as a forensic toxicologist. While in this role, she performed analysis of postmortem toxicology casework, identification of seized drug evidence, and development\/validation of new assays by LC-MS\/MS, GC-MS, and GC-FID."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/39943","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=39943"}],"version-history":[{"count":24,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/39943\/revisions"}],"predecessor-version":[{"id":102388,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/39943\/revisions\/102388"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/6457"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=39943"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=39943"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=39943"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=39943"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=39943"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=39943"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=39943"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=39943"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=39943"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}