{"id":42153,"date":"2025-08-21T13:17:24","date_gmt":"2025-08-21T13:17:24","guid":{"rendered":"https:\/\/discover.restek.com\/?p=42153"},"modified":"2025-12-03T17:33:19","modified_gmt":"2025-12-03T17:33:19","slug":"restek-liquid-chromatography-lc-columns-usage-care-ja","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/instruction-sheets-ja\/700-02-002-ja\/restek-liquid-chromatography-lc-columns-usage-care-ja","title":{"rendered":"Restek\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc(LC)\u30ab\u30e9\u30e0 -\u4f7f\u7528\u65b9\u6cd5\u304a\u3088\u3073\u53d6\u6271\u3044"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">\u5206\u6790\u30ab\u30e9\u30e0\u8a66\u9a13\u6210\u7e3e\u66f8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc(LC)\u30ab\u30e9\u30e0\u306f\u3001\u500b\u5225\u306b\u5145\u586b\u3055\u308c\u3001\u512a\u308c\u305f\u6027\u80fd\u3092\u4fdd\u8a3c\u3059\u308b\u305f\u3081\u306b\u8a66\u9a13\u3055\u308c\u3066\u3044\u307e\u3059\u3002LC\u30ab\u30e9\u30e0\u306e\u8a66\u9a13\u6210\u7e3e\u66f8\u306f\u3001\u30ab\u30e9\u30e0 \u3054\u3068\u306b\u767a\u884c\u3055\u308c\u307e\u3059\u3002\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3060\u3051\u3067\u306a\u304f\u3001\u30ab\u30e9\u30e0\u30b7\u30ea\u30a2\u30eb\u756a\u53f7\u3084\u5145\u586b\u6750\u30ed\u30c3\u30c8\u756a\u53f7\u306a\u3069\u306e\u30ab\u30e9\u30e0\u56fa\u6709\u60c5\u5831\u3082\u542b\u307e\u308c\u307e\u3059\u3002www.restek.com\/documentation \u304b\u3089\u8a66\u9a13\u6210\u7e3e\u66f8\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3057\u3001\u5fc5\u8981\u306b\u5fdc\u3058\u3066\u3001\u8a18\u9332\u307e\u305f\u306f\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u306e\u305f\u3081\u306b\u4fdd\u7ba1\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30ab\u30e9\u30e0\u30cf\u30fc\u30c9\u30a6\u30a7\u30a2<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3059\u3079\u3066\u306eRestek\u30ab\u30e9\u30e0\u30cf\u30fc\u30c9\u30a6\u30a7\u30a2\u306f\u3001\u30b9\u30c6\u30f3\u30ec\u30b9SUS316\u3092\u7528\u3044\u3066\u3044\u307e\u3059\u3002\u7c92\u5b50\u5f842.7\u03bcm\u306eRaptor\u30ab\u30e9\u30e0\u304a\u3088\u3073\u7c92\u5b50\u5f843\u03bcm\u3088\u308a\u5927\u304d\u3044\u5145\u5861\u5264\u306e\u30ab\u30e9\u30e0\u306f\u3001 2\u03bcm\u306e\u30d5\u30ea\u30c3\u30c8\u3092\u63a1\u7528\u3057\u3066\u3044\u307e\u3059\u3002\u4ed6\u306e\u3059\u3079\u3066\u306e\u30ab\u30e9\u30e0\u306f0.5\u03bcm\u306e\u30d5\u30ea\u30c3\u30c8\u3092\u63a1\u7528\u3057\u3066\u3044\u307e\u3059\u3002Restek LC\u30ab\u30e9\u30e0\u30a8\u30f3\u30c9\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u306f\u3001Valco\u3001Parker\u3001Upchurch\u3001Swagelok\u3001\u304a\u3088\u3073\u4ed6\u306e\u30d6\u30e9\u30f3\u30c9\u306e10-32\u30b5\u30a4\u30ba\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u3068\u4e92\u63db\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u306b\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u3092\u5dee\u3057\u8fbc\u3080\u969b\u3001\u9069\u5207\u306a\u30d5\u30a3\u30c3\u30c8\u611f \u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u306b\u3001\u30ab\u30e9\u30e0\u306e\u5165\u53e3\u5074\u3068\u51fa\u53e3\u5074\u306e\u4e21\u65b9\u306e\u30ca\u30c3\u30c8\u3068\u30d5\u30a7\u30eb\u30fc\u30eb\u3092\u4ea4\u63db\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u30ab\u30e9\u30e0\u30b3\u30cd\u30af\u30bf\u30fc\u304c\u6b63\u3057\u304f\u53d6\u308a\u4ed8\u3051\u3089\u308c\u3066 \u3044\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u3066\u304b\u3089\u7de0\u3081\u4ed8\u3051\u3066\u304f\u3060\u3055\u3044\u3002\u6b63\u3057\u304f\u53d6\u308a\u4ed8\u3051\u3089\u308c\u3066\u3044\u306a\u3044\u3068\u3001\u30ab\u30e9\u30e0\u52b9\u7387\u306b\u60aa\u5f71\u97ff\u3092\u53ca\u307c\u3057\u3001\u30ab\u30e9\u30e0\u306e\u53d6\u308a\u5916\u3057\u304c\u56f0\u96e3\u306b\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e \u3059\u3002Restek\u30ab\u30e9\u30e0\u306f\u3001PEEK\u88fd\u30a8\u30f3\u30c9\u30d7\u30e9\u30b0\u304c\u4ed8\u5c5e\u3057\u307e\u3059\u3002\u53d6\u4ed8\u3051\u524d\u306b\u30d7\u30e9\u30b0\u3092\u7de9\u3081\u3001\u53d6\u308a\u5916\u3057\u3066\u304f\u3060\u3055\u3044\uff08\u30ab\u30e9\u30e0\u306e\u53d6\u308a\u4ed8\u3051\u306b\u95a2\u3059\u308b\u8ffd\u52a0\u4e8b\u9805\u306b\u3064\u3044\u3066\u306f\u3001LC\u30b7\u30b9\u30c6\u30e0\u306e\u30aa\u30da\u30ec\u30fc\u30b7\u30e7\u30f3\u30de\u30cb\u30e5\u30a2\u30eb\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\uff09\u3002\u30ab<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30ab\u30e9\u30e0\u306e\u53d6\u308a\u4ed8\u3051\u3068\u4f7f\u7528<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u79fb\u52d5\u76f8<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u51fa\u8377\u6642\u306e\u30ab\u30e9\u30e0\u306b\u306fLC\u8a66\u9a13\u6210\u7e3e\u66f8\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u4fdd\u7ba1\u6eb6\u5a92\u304c\u5c01\u5165\u3055\u308c\u3066\u3044\u307e\u3059\uff08www.restek.com\/documentation \u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3057\u3066\u304f\u3060\u3055\u3044)\u3002\u4f7f\u7528\u3059\u308b\u79fb\u52d5\u76f8\u304c\u3053\u306e\u6eb6\u5a92\u3068\u6df7\u548c\u6027\u304c\u3042\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u305d\u3046\u3067\u306a\u3044\u5834\u5408\u306f\u3001\u4fdd\u7ba1\u6eb6\u5a92\u3068\u4f7f\u7528\u3057\u305f\u3044\u79fb\u52d5\u76f8\u306e\u4e21\u65b9\u306b\u6df7\u548c\u3059\u308b\u4e2d\u9593\u6eb6\u5a92\u3067\u30ab\u30e9\u30e0\u3092\u7f6e\u63db\u3057\u307e\u3059\u3002\u6eb6\u5264\u306e\u6df7\u548c\u6027\u304c\u308f\u304b\u3089\u306a\u3044\u5834\u5408\u306f\u3001www.restek.com\/solvent-chart\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044 \u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001Restek \u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30fc\u30d3\u30b9\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002\u7de9\u885d\u6db2\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u306f\u7279\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u307b\u3068\u3093\u3069\u306e\u30ab\u30e9\u30e0\u306e\u4fdd\u7ba1\u6eb6\u5a92\u306b\u306f50%\u3092\u8d85\u3048\u308b\u6709\u6a5f\u6eb6\u5a92\u304c\u542b\u307e\u308c\u3066\u304a\u308a\u3001\u7de9\u885d\u6db2\u3068\u6df7\u3056\u308b\u3068\u6c88\u6bbf\u7269\u304c\u5f62\u6210\u3055\u308c\u3001\u30ab\u30e9\u30e0\u304c\u8a70\u307e\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u901a\u6db2\u65b9\u5411\u3068\u6d41\u91cf<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ab\u30e9\u30e0\u30e9\u30d9\u30eb\u4e0a\u306e\u77e2\u5370\u306f\u3001\u63a8\u5968\u3055\u308c\u308b\u901a\u6db2\u65b9\u5411\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u6700\u521d\u306b\u3001\u30ab\u30e9\u30e0\u306e\u5165\u53e3\u5074\u3092\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u307e\u305f\u306f\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u306b\u63a5\u7d9a\u3057\u3001\u30ab\u30e9\u30e0\u306e\u51fa\u53e3\u5074\u306f\u3001\u30d3\u30fc\u30ab\u30fc\u3067\u53d7\u3051\u79fb\u52d5\u76f8\u309210\uff5e15\u5206\u9593\u901a\u6db2\u3057\u307e\u3059\u3002\u6d41\u91cf\u3092\u5f90\u3005\u306b\u6700\u9069\u5024\u307e\u3067\u5897\u52a0\u3055\u305b\u307e\u3059(\u8868I)\u3002\u305d\u306e\u5f8c\u3001\u79fb\u52d5\u76f8\u306e\u901a\u6db2\u3092\u6b62\u3081\u3001\u30ab\u30e9\u30e0\u3092\u691c\u51fa\u5668\u306b\u63a5\u7d9a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7279\u306b\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u30e2\u30fc\u30c9\u3067\u4f7f\u7528\u3057\u305f\u5834\u5408\u3001\u5168\u3066\u306eLC\u30b7\u30b9\u30c6\u30e0\u306f\u56fa\u6709\u306e\u3082\u306e\u3067\u3042\u308b\u305f\u3081\u3001\u5f53\u793e\u306e\u30e9\u30dc\u3067\u5f97\u3089\u308c\u305f\u7d50\u679c\u3068\u306f\u7570\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002Restek Technical Service \u306f\u3001\u5206\u96e2\u306e\u6700\u9069\u5316\u3092\u652f\u63f4\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u304a\u554f\u5408\u305b\u306e\u524d\u306b\u306f\u3001\u5fc5\u305a\u30ab\u30e9\u30e0\u5727\u529b\u3092\u8a18\u9332\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> Optimal Flow Rates Based on Particle Diameter and Column ID<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><thead><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\"><strong>Column ID (mm)<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\"><strong>Optimal Flow Rate (mL\/min)<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>1.9 \u03bcm dp<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>3 \u03bcm dp<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>5 \u03bcm dp<\/strong><\/td><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">4.6<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u2014<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.50<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.00<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">3.2<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u2014<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.73<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.50<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">3.0<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.12<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.65<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.40<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">2.1<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.55<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.31<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.20<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">1.0<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u2014<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.07<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.05<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u5e73\u8861\u5316<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f7f\u7528\u524d\u306b\u3001\u6700\u521d\u306e\u8a66\u9a13\u6761\u4ef6\u306e\u79fb\u52d5\u76f8\u3067\u3001\u30ab\u30e9\u30e0\u3092\u5c11\u306a\u304f\u3068\u30825\uff5e10\u30ab\u30e9\u30e0\u5bb9\u91cf\u3092\u901a\u6db2\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u307e\u3059\u3002\u7279\u5b9a\u306e\u30ab\u30e9\u30e0\u30bf\u30a4\u30d7\u306e\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u306b\u63a8\u5968\u3055\u308c\u308b\u30ea\u30bd\u30fc\u30b9\u306b\u3064\u3044\u3066\u306f\u3001\u4ee5\u4e0b\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30ab\u30e9\u30e0\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001Restek Technical Service \u306b\u304a\u554f\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u9006\u76f8\u30ab\u30e9\u30e0\u306e\u6761\u4ef6\u8a2d\u5b9a\u3068\u5e73\u8861\u5316\u306b\u95a2\u3059\u308b\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001www.restek.com\/reversephaseconditioning \u3092\u3054\u89a7\u304f\u3060\u3055\u3044<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">HILIC\u30ab\u30e9\u30e0\u306e\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3068\u5e73\u8861\u5316\u306b\u95a2\u3059\u308b\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001www.restek.com\/HILICconditioning\u3092\u3054\u89a7\u304f\u3060\u3055\u3044<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Raptor EtG\/EtS\u30ab\u30e9\u30e0\u306e\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3068\u5e73\u8861\u5316\u306b\u95a2\u3059\u308b\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001www.restek.com\/EtGEtSconditioning\u3092\u3054\u89a7\u304f\u3060\u3055\u3044<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30ab\u30e9\u30e0\u306e\u4fdd\u5b88<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b7\u30b9\u30c6\u30e0\u5727\u529b\u3092\u7d99\u7d9a\u7684\u306b\u30e2\u30cb\u30bf\u30fc\u3059\u308b\u3053\u3068\u3067\u3001\u30ab\u30e9\u30e0\u306e\u6d17\u6d44\u3001\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u307e\u305f\u306f\u30d5\u30a3\u30eb\u30bf\u30fc\u306e\u4ea4\u63db\u3001\u6ce8\u5165\u53e3\u30d5\u30ea\u30c3\u30c8\u306e\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306a\u3069\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u5fc5\u8981\u6027\u304b\u3069\u3046\u304b\u5224\u65ad\u3067\u304d\u307e\u3059\u3002\u30ab\u30e9\u30e0\u306e\u80cc\u5727\u306e\u5897\u52a0\u306f\u3001\u5165\u53e3\u5074\u30d5\u30ea\u30c3\u30c8\u304c\u8a70\u307e\u3063\u3066\u3044\u308b\u304b\u3001\u305d\u306e\u4ed6\u306e\u554f\u984c\u3092\u793a\u3057\u307e\u3059\u3002\u30ab\u30e9\u30e0\u306e\u4f7f\u7528\u4e2d\u306b\u30b7\u30b9\u30c6\u30e0\u306e\u80cc\u5727\u304c\u4e0a\u6607\u3057\u59cb\u3081\u305f\u5834\u5408\u3001\u30ab\u30e9\u30e0\u3092\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\uff08\u9006\u6d17\u6d44\uff09\u3059\u308b\u3068\u3001\u30ab\u30e9\u30e0\u5165\u53e3\u5074\u306e\u30d5\u30ea\u30c3\u30c8\u306b\u84c4\u7a4d\u3057\u305f\u593e\u96d1\u7269\u3092\u9664\u53bb\u3057\u3066\u5727\u529b\u304c\u4f4e\u4e0b\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059(\u9006\u6d17\u6d44\u306f\u30011.8\u03bcm \u307e\u305f\u306f1.9\u03bcm Force \u307e\u305f\u306fPinnacle DB \u30ab\u30e9\u30e0\u3067\u306f\u63a8\u5968\u3055\u308c\u307e\u305b\u3093\u3002\u3053\u308c\u3089\u306e\u30ab\u30e9\u30e0\u30bf\u30a4\u30d7\u3067\u306e\u80cc\u5727\u306e\u5897\u52a0\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u306f\u3001Restek Technical Service \u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002)\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u9006\u6d17\u6d44\u304c\u9069\u5207\u306a\u5834\u5408\u306f\u3001\u6700\u521d\u306b\u6d41\u91cf\u3092\u30aa\u30d5\u306b\u3057\u3001\u6b21\u306b\u30ab\u30e9\u30e0\u3092\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u3068\u691c\u51fa\u5668\u304b\u3089\u53d6\u308a\u5916\u3057\u307e\u3059\u3002\u30ab\u30e9\u30e0\u306e\u51fa\u53e3\u5074\u3092\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u307e\u305f\u306f\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u5074\u306b\u63a5\u7d9a\u3057\u3066\u3001\u30ab\u30e9\u30e0\u306e\u901a\u6db2\u65b9\u5411\u3092\u53cd\u8ee2\u3055\u305b\u307e\u3059\u3002\u5206\u96e2\u30e2\u30fc\u30c9\u306b\u9069\u5408\u3057\u305f\u6eb6\u5a92\u3092\u4f7f\u7528\u3057\u3066\u3001\u30ab\u30e9\u30e0\u3092\u4f4e\u6d41\u91cf(\u30ab\u30e9\u30e0\u306e\u6700\u9069\u6d41\u91cf\u306e\u7d041\/4\uff5e1\/2)\u3067\u9006\u6d17\u6d44\u3057\u307e\u3059\u3002\u30ab\u30e9\u30e0\u306e\u5165\u53e3\u5074\u304b\u3089\u6d41\u308c\u51fa\u3066\u304f\u308b\u6eb6\u5a92\u3092\u30d3\u30fc\u30ab\u30fc\u3067\u53d7\u3051\u307e\u3059\u3002\u30ab\u30e9\u30e0\u3092\u691c\u51fa\u5668\u306b\u306f\u3001\u6d41\u3055\u306a\u3044\u3067\u304f\u3060\u3055\u3044\u3002\u6d17\u6d44\u5f8c\u3001\u901a\u5e38\u306e\u901a\u6db2\u65b9\u5411\u306b\u623b\u3057\u3001\u79fb\u52d5\u76f8\u3067\u30ab\u30e9\u30e0\u3092\u518d\u5e73\u8861\u5316\u3057\u307e\u3059\u3002\u80cc\u5727\u304c\u4f4e\u4e0b\u3059\u308b\u5834\u5408\u306f\u3001\u4eca\u5f8c\u306e\u5206\u6790\u306b\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u307e\u305f\u306f\u30d7\u30ec\u30ab\u30e9\u30e0\u30d5\u30a3\u30eb\u30bf\u30fc\u306e\u4f7f\u7528\u3092\u691c\u8a0e\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6c5a\u67d3\u306e\u7591\u3044\u304c\u3042\u308a\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u60aa\u5316\u3057\u305f\u5834\u5408\u306f\u3001\u6c34\u6bd4\u7387\u306e\u9ad8\u3044\u6761\u4ef6\u3067\u958b\u59cb\u3057\u3001\u9577\u3044\u6642\u9593\u3092\u304b\u3051\u3066\u6709\u6a5f\u6eb6\u5a92\u6bd4\u7387\u3092\u9ad8\u304f\u3059\u308b\u3088\u3046\u306a\u30b0\u30e9\u30b8\u30a8\u30f3\u30c9\u52fe\u914d\u3067\u30ab\u30e9\u30e0\u3092\u6d17\u6d44\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30ab\u30e9\u30e0\u3092\u6d17\u6d44\u3057\u305f\u5f8c\u3001\u79fb\u52d5\u76f8\u3067\u30ab\u30e9\u30e0\u3092\u518d\u5e73\u8861\u5316\u3057\u3001\u6027\u80fd\u306e\u5411\u4e0a\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002\u554f\u984c\u304c\u7d99\u7d9a\u3059\u308b\u5834\u5408\u306f\u3001\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306e\u4f7f\u7528\u3092\u691c\u8a0e\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6d17\u6d44\u6eb6\u5a92\u306e\u9078\u629e\u3084\u30ab\u30e9\u30e0\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306b\u95a2\u3059\u308b\u8a73\u7d30\u60c5\u5831\u304c\u5fc5\u8981\u306a\u5834\u5408\u306f\u3001Restek Technical Service\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30ab\u30e9\u30e0\u306e\u6d17\u6d44\u3068\u4fdd\u7ba1<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ab\u30e9\u30e0\u306f\u3001\u4fdd\u7ba1\u524d\u306b\u7de9\u885d\u5869\u3001\u9178\u3001\u307e\u305f\u306f\u5869\u57fa\u3092\u9664\u53bb\u3059\u308b\u305f\u3081\u306b\u5c11\u306a\u304f\u3068\u308210\uff5e20\u30ab\u30e9\u30e0\u5bb9\u91cf\u306e\u6eb6\u6db2\u3067\u6d17\u6d44\u3092\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u77ed\u671f\u9593\u306e\u4fdd\u7ba1\u3067\u306f\u3001\u7de9\u885d\u6db2\u3001\u9178\u6027\u307e\u305f\u306f\u5869\u57fa\u6027\u6210\u5206\u3092\u9664\u3044\u305f\u3001\u76f4\u8fd1\u306b\u4f7f\u7528\u3057\u305f\u79fb\u52d5\u76f8\u3068\u540c\u3058\u7d44\u6210\u306e\u6eb6\u5a92\u3067\u3001\u30ab\u30e9\u30e0\u3092\u6d17\u6d44\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u9577\u671f\u4fdd\u7ba1\u306e\u5834\u5408\u3001\u9006\u76f8\u30ab\u30e9\u30e0\u306f50%\u6c34\/50%\u6709\u6a5f\u6eb6\u5a92(\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u3084\u30e1\u30bf\u30ce\u30fc\u30eb\u306a\u3069)\u3067\u4fdd\u7ba1\u3057\u3001\u9806\u76f8\u30ab\u30e9\u30e0\u306f\u975e\u6975\u6027\u6eb6\u5a92(\u30d8\u30ad\u30b5\u30f3\u306a\u3069)\u3067\u4fdd\u7ba1\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u9577\u671f\u4fdd\u7ba1\u6eb6\u5a92\u304c\u76f4\u8fd1\u3067\u4f7f\u7528\u3057\u305f\u79fb\u52d5\u76f8\u3068\u6df7\u548c\u3057\u306a\u3044\u5834\u5408\u3001\u76f4\u8fd1\u3067\u4f7f\u7528\u3057\u305f\u79fb\u52d5\u76f8\u304a\u3088\u3073\u4fdd\u7ba1\u6eb6\u5a92\u306e\u4e21\u65b9\u3068\u6df7\u548c\u3059\u308b\u4e2d\u9593\u6eb6\u5a92\u3067\u30ab\u30e9\u30e0\u3092\u6d17\u6d44\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30a8\u30f3\u30c9\u30d7\u30e9\u30b0\u3092\u3057\u3063\u304b\u308a\u3068\u56fa\u5b9a\u3057\u3066\u30ab\u30e9\u30e0\u3092\u4fdd\u7ba1\u3057\u3001\u4fdd\u7ba1\u6eb6\u5a92\u306e\u8a18\u9332\u3092\u5fc5\u305a\u6dfb\u4ed8\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30ab\u30e9\u30e0\u306e\u5bff\u547d\u3092\u5ef6\u3070\u3059\u305f\u3081\u306e\u6700\u9069\u306a\u65b9\u6cd5<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5b9a\u671f\u7684\u306a\u30ab\u30e9\u30e0\u6d17\u6d44\u306f\u3001\u30ab\u30e9\u30e0\u306e\u5bff\u547d\u3092\u5927\u5e45\u306b\u5ef6\u3070\u3059\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u7406\u60f3\u7684\u306a\u6d17\u6d44\u6eb6\u5a92\u306f\u3001\u7de9\u885d\u5869\u3001\u9178\u6027\u3001\u307e\u305f\u306f\u5869\u57fa\u6027\u6210\u5206\u3092\u542b\u307e\u306a\u3044\u6700\u3082\u76f4\u8fd1\u3067\u4f7f\u7528\u3057\u305f\u79fb\u52d5\u76f8\u3068\u7d44\u6210\u304c\u540c\u4e00\u306e\u6eb6\u5a92\u3067\u3059\u3002\u30ab\u30e9\u30e0\u3092\u6d17\u6d44\u3059\u308b\u3068\u304d\u306f\u3001\u5c11\u306a\u304f\u3068\u308210\uff5e20\u30ab\u30e9\u30e0\u5bb9\u91cf\u306e\u6d17\u6d44\u6eb6\u6db2\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u307e\u3059\u3002&nbsp;<\/li>\n\n\n\n<li>\u6975\u7aef\u306apH\u5024\u3067\u306e\u9577\u6642\u9593\u306e\u4f7f\u7528\u306f\u63a8\u5968\u3055\u308c\u307e\u305b\u3093\u3002\u5404\u30ab\u30e9\u30e0\u306e\u4f7f\u7528pH\u30ec\u30f3\u30b8\u306e\u8a73\u7d30\u306f\u3001restek.com\u3067\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002&nbsp;<\/li>\n\n\n\n<li>\u6e29\u5ea6\u304c\u4e0a\u6607\u3059\u308b\u3068\u30ab\u30e9\u30e0\u306e\u5bff\u547d\u304c\u640d\u306a\u308f\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u30ab\u30e9\u30e0\u306e\u4e0a\u9650\u6e29\u5ea680 \u00b0C \u3092\u8d85\u3048\u306a\u3044\u3088\u3046\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002&nbsp;<\/li>\n\n\n\n<li>\u4f7f\u7528\u524d\u306b\u308d\u904e\u30fb\u8131\u6c17\u3057\u305f\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u7528\u306b\u7279\u5225\u306b\u8abf\u88fd\u3057\u305f\u6eb6\u5a92\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3092\u5f37\u304f\u304a\u52e7\u3081\u3057\u307e\u3059\u3002&nbsp;<\/li>\n\n\n\n<li>\u30ab\u30e9\u30e0\u5bff\u547d\u306f\u56fa\u5b9a\u76f8\u306e\u7a2e\u985e\u306b\u5de6\u53f3\u3055\u308c\u307e\u3059\u3002C18\u306a\u3069\u306e\u70ad\u5316\u6c34\u7d20\u7cfb\u306e\u56fa\u5b9a\u76f8\u306f\u3001\u6bd4\u8f03\u7684\u5316\u5b66\u7684\u306b\u5b89\u5b9a\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u30a2\u30df\u30ce\u57fa\u306e\u3088\u3046\u306a\u6975\u6027\u56fa\u5b9a\u76f8\u306f\u5316\u5b66\u7684\u306b\u6d3b\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u7279\u5225\u306a\u6ce8\u610f\u304c\u5fc5\u8981\u306b\u306a\u308a\u307e\u3059\u3002\u30a2\u30eb\u30c7\u30d2\u30c9\u307e\u305f\u306f\u30b1\u30c8\u30f3(\u4f8b\u3048\u3070\u3001\u30a2\u30bb\u30c8\u30f3)\u3092\u542b\u3080\u79fb\u52d5\u76f8\u306f\u3001\u30a2\u30df\u30ce\u57fa\u306e\u4fdd\u6301\u3092\u5909\u5316\u3055\u305b\u3001\u6ce8\u5165\u3092\u7e70\u308a\u8fd4\u3059\u3068\u6642\u9593\u306e\u7d4c\u904e\u3068\u3068\u3082\u306b\u56fa\u5b9a\u76f8\u3092\u5909\u8cea\u3055\u305b\u307e\u3059\u3002\u3044\u305a\u308c\u306epH\u3067\u3082\u5909\u8cea\u3057\u307e\u3059\u304c\u3001pH 4.5\uff5epH5.5\u3067\u306f\u30a2\u30df\u30ce\u57fa\u306e\u5909\u8cea\u304c\u3088\u308a\u901f\u304f\u9032\u884c\u3057\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">LC\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u30b7\u30b9\u30c6\u30e0<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u7c92\u5b50\u72b6\u7269\u8cea\u304a\u3088\u3073\u8a66\u6599\u6c5a\u67d3\u7269\u8cea\u306b\u5bfe\u3059\u308b\u6700\u5927\u9650\u306e\u4fdd\u8b77\u306e\u305f\u3081\u306b\u3001\u30ab\u30e9\u30e0\u306e\u524d\u306b\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u307e\u305f\u306f\u30d7\u30ec\u30ab\u30e9\u30e0\u30d5\u30a3\u30eb\u30bf\u30fc\u3092\u88c5\u7740\u3059\u308b\u3053\u3068\u3092\u691c\u8a0e\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001www.restek.com\/LC-guard \u3092\u3054\u89a7\u3044\u305f\u3060\u304f\u304b\u3001\u6700\u5bc4\u308a\u306eRestek \u62c5\u5f53\u8005\u3078\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Raptor Polar X<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306eRaptor Polar X LC\u30ab\u30e9\u30e0\u306b\u306f\u3001\u6700\u9ad8\u306e\u6027\u80fd\u3068\u5bff\u547d\u3092\u5f97\u308b\u305f\u3081\u306b\u7279\u5225\u306b\u8003\u616e\u3059\u3079\u304d\u4e8b\u9805\u304c\u3044\u304f\u3064\u304b\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u4e0d\u52d5\u614b\u5316:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u30ad\u30ec\u30fc\u30c8\u5316\u5408\u7269\u3092\u5206\u6790\u3059\u308b\u5834\u5408\u3001\u30b5\u30f3\u30d7\u30eb\u6d41\u8def\u5185\u306b\u304a\u3051\u308b\u91d1\u5c5e\u6210\u5206\u3092\u4e0d\u52d5\u614b\u5316\u51e6\u7406\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002&nbsp;<\/li>\n\n\n\n<li>\u30ab\u30e9\u30e0\u306f\u3001Restek\u306b\u3088\u3063\u3066\u4e0d\u52d5\u614b\u5316\u3055\u308c\u305f\u72b6\u614b\u3067\u7d0d\u54c1\u3055\u308c\u307e\u3059\u304c\u3001\u30ad\u30ec\u30fc\u30c8\u5316\u5408\u7269\u306e\u4fdd\u6301\u304c\u6e1b\u5c11\u3057\u59cb\u3081\u308b\u5834\u5408\u306f\u3001\u8ffd\u52a0\u306e\u4e0d\u52d5\u614b\u5316\u51e6\u7406\u3092\u884c\u3046\u5fc5\u8981\u304c\u3042\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002&nbsp;<\/li>\n\n\n\n<li>www.restek.com\/LCpassivation\u3067\u3001\u30b7\u30b9\u30c6\u30e0\u304a\u3088\u3073\u30ab\u30e9\u30e0\u4e0d\u52d5\u614b\u5316\u306b\u95a2\u3059\u308b\u30ac\u30a4\u30c0\u30f3\u30b9\u3068Restek\u306eLC\u4e0d\u52d5\u614b\u5316\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u304a\u3088\u3073\u624b\u9806\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044 \u3002<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u4f7f\u7528\u65b9\u6cd5:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5206\u6790\u524d\u306b\u30ab\u30e9\u30e0\u30785\uff5e10\u56de\u3001\u30d6\u30e9\u30f3\u30af\u30b5\u30f3\u30d7\u30eb\u3092\u6ce8\u5165\u3057\u307e\u3059\u3002&nbsp;<\/li>\n\n\n\n<li>\u6c34\u6bd4\u738790%\u3092\u8d85\u3048\u308b\u79fb\u52d5\u76f8\u6761\u4ef6\u306f\u907f\u3051\u3066\u304f\u3060\u3055\u3044\u3002\u6c34\u6bd4\u738790%\u3092\u8d85\u3048\u308b\u79fb\u52d5\u76f8\u3092\u4f7f\u7528\u3059\u308b\u3068\u30ab\u30e9\u30e0\u306e\u5bff\u547d\u304c\u77ed\u304f\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002&nbsp;<\/li>\n\n\n\n<li>\u9162\u9178\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0\u306f\u907f\u3051\u3066\u304f\u3060\u3055\u3044\u3002\u9162\u9178\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0\u306e\u4f7f\u7528\u306f\u3001\u4fdd\u6301\u306e\u6e1b\u5c11\u3092\u3082\u305f\u3089\u3057\u307e\u3059\u3002\u4ee3\u308f\u308a\u306b\u30ae\u9178\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002&nbsp;<\/li>\n\n\n\n<li>\u904e\u9177\u306a\u6761\u4ef6\u3067\u306f\u5bff\u547d\u304c\u77ed\u304f\u306a\u308a\u307e\u3059\u30020.5%\u4ee5\u4e0b\u306e\u9178\u304a\u3088\u307350\u2103\u4ee5\u4e0b\u306e\u30ab\u30e9\u30e0\u6e29\u5ea6\u306e\u4f7f\u7528\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u6d17\u6d44\u304a\u3088\u3073\u4fdd\u7ba1:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u6700\u826f\u306e\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306b\u3001\u5206\u6790\u7d42\u4e86\u524d\u306b\u3001\u5206\u6790\u6761\u4ef6\u306e\u6709\u6a5f\u6eb6\u5a92\u3092\u7528\u3044\u3066\u30ab\u30e9\u30e0\u3092\u6d17\u6d44\u3057\u307e\u3059\u3002&nbsp;<\/li>\n\n\n\n<li>\u4f7f\u7528\u5f8c\u306f\u3001\u30ab\u30e9\u30e0\u3092100% \u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u3067\u4fdd\u5b58\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u307e\u3059\u3002&nbsp;<\/li>\n\n\n\n<li>\u7de9\u885d\u6db2\u307e\u305f\u306f\u9178\u304c\u542b\u307e\u308c\u308b\u79fb\u52d5\u76f8\u3067\u306e\u4fdd\u5b58\u306f\u63a8\u5968\u3055\u308c\u307e\u305b\u3093\u3002&nbsp;<\/li>\n\n\n\n<li>\u7de9\u885d\u6db2\u304a\u3088\u3073\/\u307e\u305f\u306f\u9178\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u30015\uff5e10\u30ab\u30e9\u30e0\u5bb9\u91cf\u306b\u5bfe\u3057\u3066\u7de9\u885d\u6db2\u3092\u542b\u307e\u306a\u304450:50\u306eH2 O\/ACN\u3067\u30ab\u30e9\u30e0\u3092\u6d17\u6d44\u3057\u3001\u7d9a\u3044\u3066\u3001\u4fdd\u7ba1\u524d\u306b5\uff5e10\u30ab\u30e9\u30e0\u5bb9\u91cf\u306e\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u3067\u30ab\u30e9\u30e0\u3092\u6d17\u6d44\u3059\u308b\u3053\u3068\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/discover.restek.com\/wp-content\/uploads\/700-02-002JP.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"Embed of 700-02-002JP.\"><\/object><a id=\"wp-block-file--media-aa8589da-ae49-48c0-b72b-39573fa61322\" href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/700-02-002JP.pdf\">700-02-002JP<\/a><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/700-02-002JP.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-aa8589da-ae49-48c0-b72b-39573fa61322\">Download<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u5206\u6790\u30ab\u30e9\u30e0\u8a66\u9a13\u6210\u7e3e\u66f8 Restek\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc(LC)\u30ab\u30e9\u30e0\u306f\u3001\u500b\u5225\u306b\u5145\u586b\u3055\u308c\u3001\u512a\u308c\u305f\u6027\u80fd\u3092\u4fdd\u8a3c\u3059\u308b\u305f\u3081\u306b\u8a66\u9a13\u3055\u308c\u3066\u3044\u307e\u3059\u3002LC\u30ab\u30e9\u30e0\u306e\u8a66\u9a13\u6210\u7e3e\u66f8\u306f\u3001\u30ab\u30e9\u30e0 \u3054\u3068\u306b\u767a\u884c\u3055\u308c\u307e\u3059\u3002\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3060\u3051\u3067\u306a\u304f\u3001\u30ab\u30e9\u30e0\u30b7\u30ea\u30a2\u30eb\u756a\u53f7\u3084\u5145\u586b\u6750\u30ed\u30c3\u30c8\u756a\u53f7\u306a\u3069\u306e\u30ab\u30e9\u30e0\u56fa\u6709\u60c5\u5831\u3082\u542b\u307e\u308c\u307e\u3059\u3002www.restek.com\/documentation \u304b\u3089\u8a66\u9a13\u6210\u7e3e\u66f8\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3057\u3001\u5fc5\u8981\u306b\u5fdc\u3058\u3066\u3001\u8a18\u9332\u307e\u305f\u306f\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u306e\u305f\u3081\u306b\u4fdd\u7ba1\u3057\u3066\u304f\u3060\u3055\u3044\u3002 \u30ab\u30e9\u30e0\u30cf\u30fc\u30c9\u30a6\u30a7\u30a2 \u3059\u3079\u3066\u306eRestek\u30ab\u30e9\u30e0\u30cf\u30fc\u30c9\u30a6\u30a7\u30a2\u306f\u3001\u30b9\u30c6\u30f3\u30ec\u30b9SUS316\u3092\u7528\u3044\u3066\u3044\u307e\u3059\u3002\u7c92\u5b50\u5f842.7\u03bcm\u306eRaptor\u30ab\u30e9\u30e0\u304a\u3088\u3073\u7c92\u5b50\u5f843\u03bcm\u3088\u308a\u5927\u304d\u3044\u5145\u5861\u5264\u306e\u30ab\u30e9\u30e0\u306f\u3001 2\u03bcm\u306e\u30d5\u30ea\u30c3\u30c8\u3092\u63a1\u7528\u3057\u3066\u3044\u307e\u3059\u3002\u4ed6\u306e\u3059\u3079\u3066\u306e\u30ab\u30e9\u30e0\u306f0.5\u03bcm\u306e\u30d5\u30ea\u30c3\u30c8\u3092\u63a1\u7528\u3057\u3066\u3044\u307e\u3059\u3002Restek LC\u30ab\u30e9\u30e0\u30a8\u30f3\u30c9\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u306f\u3001Valco\u3001Parker\u3001Upchurch\u3001Swagelok\u3001\u304a\u3088\u3073\u4ed6\u306e\u30d6\u30e9\u30f3\u30c9\u306e10-32\u30b5\u30a4\u30ba\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u3068\u4e92\u63db\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u306b\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u3092\u5dee\u3057\u8fbc\u3080\u969b\u3001\u9069\u5207\u306a\u30d5\u30a3\u30c3\u30c8\u611f \u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u306b\u3001\u30ab\u30e9\u30e0\u306e\u5165\u53e3\u5074\u3068\u51fa\u53e3\u5074\u306e\u4e21\u65b9\u306e\u30ca\u30c3\u30c8\u3068\u30d5\u30a7\u30eb\u30fc\u30eb\u3092\u4ea4\u63db\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u30ab\u30e9\u30e0\u30b3\u30cd\u30af\u30bf\u30fc\u304c\u6b63\u3057\u304f\u53d6\u308a\u4ed8\u3051\u3089\u308c\u3066 \u3044\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u3066\u304b\u3089\u7de0\u3081\u4ed8\u3051\u3066\u304f\u3060\u3055\u3044\u3002\u6b63\u3057\u304f\u53d6\u308a\u4ed8\u3051\u3089\u308c\u3066\u3044\u306a\u3044\u3068\u3001\u30ab\u30e9\u30e0\u52b9\u7387\u306b\u60aa\u5f71\u97ff\u3092\u53ca\u307c\u3057\u3001\u30ab\u30e9\u30e0\u306e\u53d6\u308a\u5916\u3057\u304c\u56f0\u96e3\u306b\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e \u3059\u3002Restek\u30ab\u30e9\u30e0\u306f\u3001PEEK\u88fd\u30a8\u30f3\u30c9\u30d7\u30e9\u30b0\u304c\u4ed8\u5c5e\u3057\u307e\u3059\u3002\u53d6\u4ed8\u3051\u524d\u306b\u30d7\u30e9\u30b0\u3092\u7de9\u3081\u3001\u53d6\u308a\u5916\u3057\u3066\u304f\u3060\u3055\u3044\uff08\u30ab\u30e9\u30e0\u306e\u53d6\u308a\u4ed8\u3051\u306b\u95a2\u3059\u308b\u8ffd\u52a0\u4e8b\u9805\u306b\u3064\u3044\u3066\u306f\u3001LC\u30b7\u30b9\u30c6\u30e0\u306e\u30aa\u30da\u30ec\u30fc\u30b7\u30e7\u30f3\u30de\u30cb\u30e5\u30a2\u30eb\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\uff09\u3002\u30ab \u30ab\u30e9\u30e0\u306e\u53d6\u308a\u4ed8\u3051\u3068\u4f7f\u7528 \u79fb\u52d5\u76f8 \u51fa\u8377\u6642\u306e\u30ab\u30e9\u30e0\u306b\u306fLC\u8a66\u9a13\u6210\u7e3e\u66f8\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u4fdd\u7ba1\u6eb6\u5a92\u304c\u5c01\u5165\u3055\u308c\u3066\u3044\u307e\u3059\uff08www.restek.com\/documentation \u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3057\u3066\u304f\u3060\u3055\u3044)\u3002\u4f7f\u7528\u3059\u308b\u79fb\u52d5\u76f8\u304c\u3053\u306e\u6eb6\u5a92\u3068\u6df7\u548c\u6027\u304c\u3042\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u305d\u3046\u3067\u306a\u3044\u5834\u5408\u306f\u3001\u4fdd\u7ba1\u6eb6\u5a92\u3068\u4f7f\u7528\u3057\u305f\u3044\u79fb\u52d5\u76f8\u306e\u4e21\u65b9\u306b\u6df7\u548c\u3059\u308b\u4e2d\u9593\u6eb6\u5a92\u3067\u30ab\u30e9\u30e0\u3092\u7f6e\u63db\u3057\u307e\u3059\u3002\u6eb6\u5264\u306e\u6df7\u548c\u6027\u304c\u308f\u304b\u3089\u306a\u3044\u5834\u5408\u306f\u3001www.restek.com\/solvent-chart\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044 \u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001Restek \u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30fc\u30d3\u30b9\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002\u7de9\u885d\u6db2\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u306f\u7279\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u307b\u3068\u3093\u3069\u306e\u30ab\u30e9\u30e0\u306e\u4fdd\u7ba1\u6eb6\u5a92\u306b\u306f50%\u3092\u8d85\u3048\u308b\u6709\u6a5f\u6eb6\u5a92\u304c\u542b\u307e\u308c\u3066\u304a\u308a\u3001\u7de9\u885d\u6db2\u3068\u6df7\u3056\u308b\u3068\u6c88\u6bbf\u7269\u304c\u5f62\u6210\u3055\u308c\u3001\u30ab\u30e9\u30e0\u304c\u8a70\u307e\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002 \u901a\u6db2\u65b9\u5411\u3068\u6d41\u91cf \u30ab\u30e9\u30e0\u30e9\u30d9\u30eb\u4e0a\u306e\u77e2\u5370\u306f\u3001\u63a8\u5968\u3055\u308c\u308b\u901a\u6db2\u65b9\u5411\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u6700\u521d\u306b\u3001\u30ab\u30e9\u30e0\u306e\u5165\u53e3\u5074\u3092\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u307e\u305f\u306f\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u306b\u63a5\u7d9a\u3057\u3001\u30ab\u30e9\u30e0\u306e\u51fa\u53e3\u5074\u306f\u3001\u30d3\u30fc\u30ab\u30fc\u3067\u53d7\u3051\u79fb\u52d5\u76f8\u309210\uff5e15\u5206\u9593\u901a\u6db2\u3057\u307e\u3059\u3002\u6d41\u91cf\u3092\u5f90\u3005\u306b\u6700\u9069\u5024\u307e\u3067\u5897\u52a0\u3055\u305b\u307e\u3059(\u8868I)\u3002\u305d\u306e\u5f8c\u3001\u79fb\u52d5\u76f8\u306e\u901a\u6db2\u3092\u6b62\u3081\u3001\u30ab\u30e9\u30e0\u3092\u691c\u51fa\u5668\u306b\u63a5\u7d9a\u3057\u307e\u3059\u3002 \u7279\u306b\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u30e2\u30fc\u30c9\u3067\u4f7f\u7528\u3057\u305f\u5834\u5408\u3001\u5168\u3066\u306eLC\u30b7\u30b9\u30c6\u30e0\u306f\u56fa\u6709\u306e\u3082\u306e\u3067\u3042\u308b\u305f\u3081\u3001\u5f53\u793e\u306e\u30e9\u30dc\u3067\u5f97\u3089\u308c\u305f\u7d50\u679c\u3068\u306f\u7570\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002Restek Technical Service \u306f\u3001\u5206\u96e2\u306e\u6700\u9069\u5316\u3092\u652f\u63f4\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u304a\u554f\u5408\u305b\u306e\u524d\u306b\u306f\u3001\u5fc5\u305a\u30ab\u30e9\u30e0\u5727\u529b\u3092\u8a18\u9332\u3057\u3066\u304f\u3060\u3055\u3044\u3002 Table I: Optimal Flow Rates Based on Particle Diameter and Column ID Column ID (mm) Optimal Flow Rate (mL\/min) 1.9 \u03bcm dp 3 \u03bcm dp 5 \u03bcm dp 4.6 \u2014 1.50 1.00&#8230;<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[809],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2343],"ppma_author":[2814],"class_list":["post-42153","post","type-post","status-publish","format-standard","hentry","category-instruction-sheets-ja","resource-technique-liquid-chromatography-ja"],"acf":[],"taxonomy_info":{"category":[{"value":809,"label":"Instruction Sheets"}],"resource-technique":[{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":809,"name":"Instruction Sheets","slug":"instruction-sheets-ja","term_group":0,"term_taxonomy_id":809,"taxonomy":"category","description":"","parent":0,"count":204,"filter":"raw","cat_ID":809,"category_count":204,"category_description":"","cat_name":"Instruction Sheets","category_nicename":"instruction-sheets-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42153","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=42153"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42153\/revisions"}],"predecessor-version":[{"id":70692,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42153\/revisions\/70692"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=42153"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=42153"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=42153"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=42153"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=42153"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=42153"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=42153"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=42153"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=42153"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}