{"id":42381,"date":"2020-04-21T04:00:00","date_gmt":"2020-04-21T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-split-vs-splitless-injection\/"},"modified":"2026-01-13T22:35:45","modified_gmt":"2026-01-13T22:35:45","slug":"japanese-split-vs-splitless-injection","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3658-ja\/japanese-split-vs-splitless-injection","title":{"rendered":"\u30b9\u30d7\u30ea\u30c3\u30c8 vs. \u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Split vs. Splitless Injection\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/TaLOF_jVRno?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"512\" height=\"373\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1.png\" alt=\"\" class=\"wp-image-29853\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1.png 512w, https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1-300x219.png 300w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"447\" height=\"528\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12.png\" alt=\"\" class=\"wp-image-29859\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12.png 447w, https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12-254x300.png 254w\" sizes=\"auto, (max-width: 447px) 100vw, 447px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">YouTube\u753b\u9762\u53f3\u4e0b\u306b\u3042\u308b\u8a2d\u5b9a\u30dc\u30bf\u30f3\u2699\u304b\u3089Subtitles\/CC\u3092\u9078\u3073\u3001Japanese\u306b\u30c1\u30a7\u30c3\u30af\u3092\u5165\u308c\u308b\u3068\u65e5\u672c\u8a9e\u5b57\u5e55\u3042\u308a\u3067\u52d5\u753b\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u6982\u8981<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b9\u30d7\u30ea\u30c3\u30c8\u304a\u3088\u3073\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u306f\u3001\u6700\u3082\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u308bGC\u6ce8\u5165\u6280\u8853\u3067\u3059\u3002\u305d\u308c\u3089\u306f\u3044\u304f\u3064\u304b\u306e\u985e\u4f3c\u70b9\u3092\u5171\u6709\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u305d\u308c\u305e\u308c\u304c\u7279\u5b9a\u306e\u30bf\u30a4\u30d7\u306e\u5206\u6790\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u3069\u3061\u3089\u3092\u4f7f\u7528\u3059\u308b\u304b\u3092\u3069\u3046\u3084\u3063\u3066\u77e5\u308b\u306e\u3067\u3057\u3087\u3046\u304b\uff1f&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u30d3\u30c7\u30aa\u3067\u306f\u3001\u3053\u308c\u30892\u3064\u306e\u624b\u6cd5\u304c\u3069\u306e\u3088\u3046\u306b\u6a5f\u80fd\u3059\u308b\u306e\u304b\u3092\u63a2\u308a\u307e\u3059\u3002\u307e\u305a\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u304b\u3089\u59cb\u3081\u307e\u3057\u3087\u3046\u3002\u305d\u306e\u624b\u6cd5\u3092\u793a\u3057\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6bd4\u3068\u306f\u4f55\u304b\u3092\u8aac\u660e\u3057\u307e\u3059\u3002\u6b21\u306b\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u5207\u308a\u66ff\u3048\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30e2\u30fc\u30c9\u3068\u306e\u9055\u3044\u3092\u793a\u3057\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u30db\u30fc\u30eb\u30c9\u30bf\u30a4\u30e0\u3068\u306f\u4f55\u304b\u3001\u306a\u305c\u91cd\u8981\u306a\u306e\u304b\u3092\u8aac\u660e\u3057\u307e\u3059\u3002\u6700\u5f8c\u306b\u3001\u5404\u30e2\u30fc\u30c9\u306e\u9577\u6240\u3092\u78ba\u8a8d\u3057\u3001\u5206\u6790\u306b\u9069\u3057\u305f\u3082\u306e\u3092\u9078\u629e\u3067\u304d\u308b\u3088\u3046\u306b\u3057\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Restek\u63a8\u5968\u30c4\u30fc\u30eb\u3068\u90e8\u54c1<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1210\" target=\"_blank\" rel=\"noopener\">Restek&nbsp;Inlet&nbsp;Liners<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/p\/28500\" target=\"_blank\" rel=\"noopener\">Restek Electronic Leak Detector<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Restek\u306b\u306f\u3053\u3061\u3089\u304b\u3089\u3082\u30a2\u30af\u30bb\u30b9\u3067\u304d\u307e\u3059<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">YouTube:&nbsp;<a href=\"https:\/\/www.youtube.com\/user\/RestekCorp\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.youtube.com\/user\/RestekCorp<\/a>&nbsp;<br>LinkedIn:&nbsp;<a href=\"https:\/\/www.linkedin.com\/company\/restek-corporation\/\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.linkedin.com\/company\/restek-corporation\/<\/a><br>Facebook:&nbsp;<a href=\"https:\/\/www.facebook.com\/RestekCorporation\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.facebook.com\/RestekCorporation<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b9\u30d7\u30ea\u30c3\u30c8 vs. \u30b9\u30d7\u30ea\u30c8\u30ec\u30b9\u6ce8\u5165<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b9\u30d7\u30ea\u30c3\u30c8\u3068\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u306f\u3001\u6700\u3082\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u308b2\u3064\u306eGC\u6ce8\u5165\u65b9\u6cd5\u3067\u3059\u3002\u305d\u308c\u3089\u306f\u3069\u3046\u9055\u3044\u307e\u3059\u304b\uff1f\u305d\u3057\u3066\u3001\u3042\u306a\u305f\u306e\u5206\u6790\u306e\u305f\u3081\u306b\u3069\u308c\u3092\u4f7f\u3046\u3079\u304d\u3067\u3059\u304b\uff1f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305a\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u304b\u3089\u59cb\u3081\u307e\u3057\u3087\u3046\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306f\u3001\u3055\u307e\u3056\u307e\u306f\u5206\u6790\u306b\u5bfe\u5fdc\u3067\u304d\u308b\u6c4e\u7528\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u6700\u3082\u4eba\u6c17\u304c\u3042\u308a\u307e\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\uff0f\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u53e3\u306e\u5185\u90e8\u306b\u306f\u3001\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u4f9b\u7d66\u3001\u30bb\u30d7\u30bf\u30e0\u3001\u30bb\u30d7\u30bf\u30e0\u30d1\u30fc\u30b8\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u3001\u30e9\u30a4\u30ca\u30fc\u3001\u304a\u3088\u3073\u30ab\u30e9\u30e0\u304c\u3042\u308a\u307e\u3059\u3002\u6b21\u306b\u30ac\u30b9\u3092\u6d41\u3057\u59cb\u3081\u3066\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3092\u30b7\u30df\u30e5\u30ec\u30fc\u30c8\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5dfb\u304d\u623b\u3057\u3066\u3001\u4f55\u304c\u8d77\u3053\u3063\u305f\u306e\u304b\u3092\u898b\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u6700\u521d\u306b\u3001\u30ac\u30b9\u306f104 mL\/min\u306e\u30c8\u30fc\u30bf\u30eb\u6d41\u91cf\u3067\u5165\u53e3\u306b\u5165\u308a\u307e\u3057\u305f\u3002\u5c11\u91cf\uff083 mL\/min\uff09\u3092\u30bb\u30d7\u30bf\u30e0\u30d1\u30fc\u30b8\u306b\u6d41\u3057\u3001\u30bb\u30d7\u30bf\u30e0\u304b\u3089\u306e\u6c5a\u67d3\u306e\u53ef\u80fd\u6027\u3092\u6e1b\u3089\u3057\u3001\u6b8b\u308a\u306f\u30e9\u30a4\u30ca\u30fc\u306b\u6d41\u308c\u3066\u3044\u304d\u307e\u3057\u305f\u3002\u30ac\u30b9\u306e\u4e00\u90e8\uff081 mL\/min\uff09\u304c\u30ab\u30e9\u30e0\u3078\u3068\u5165\u3063\u3066\u3044\u304d\u307e\u3057\u305f\u304c\u3001\u307b\u3068\u3093\u3069\uff08100 mL\/min\uff09\u306f\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u3092\u4ecb\u3057\u3066\u5410\u304d\u51fa\u3055\u308c\u307e\u3059\u3002&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u6bd4\u7387\u3001\u3064\u307e\u308a\u30b9\u30d7\u30ea\u30c3\u30c8\u6bd4\u306f\u3001\u5206\u6790\u3092\u958b\u59cb\u3059\u308b\u524d\u306b\u30e6\u30fc\u30b6\u30fc\u304c\u6c7a\u5b9a\u3057\u307e\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u6bd4\u306f\u901a\u5e385:1\u304b\u3089500:1\u306e\u9593\u3067\u8a2d\u5b9a\u3055\u308c\u3001\u305d\u306e\u6bd4\u7387\u304c\u9ad8\u3044\u307b\u3069\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u3092\u901a\u904e\u3059\u308b\u30b5\u30f3\u30d7\u30eb\u3068\u6bd4\u8f03\u3057\u3066\u30ab\u30e9\u30e0\u306b\u5165\u308b\u30b5\u30f3\u30d7\u30eb\u306b\u91cf\u304c\u5c11\u306a\u304f\u306a\u308a\u307e\u3059\u3002\u6ce8\u5165\u306e\u9593\u3001\u30b5\u30f3\u30d7\u30eb\u306f\u30e9\u30a4\u30ca\u30fc\u306b\u6ce8\u5165\u3055\u308c\u3001\u6c17\u5316\u3057\u307e\u3059\u3002\u3053\u306e\u4f8b\u3067\u306f\u30b9\u30d7\u30ea\u30c3\u30c8\u6bd4\u304c100:1\u3068\u9ad8\u3044\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u3046\u3061100\u304c\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u304b\u3089\u6392\u51fa\u3055\u308c\u308b\u9593\u306b\u30011\u304c\u30ab\u30e9\u30e0\u306b\u5165\u3063\u3066\u3044\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b21\u306b\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306e\u4f8b\u3092\u898b\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3067\u306f\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u306f\u6ce8\u5165\u524d\u306b\u9589\u3058\u3089\u308c\u3001\u6ce8\u5165\u4e2d\u3082\u9589\u3058\u305f\u307e\u307e\u306b\u306a\u308a\u307e\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u30d5\u30ed\u30fc\u304c\u306a\u3044\u305f\u3081\u3001\u30c8\u30fc\u30bf\u30eb\u6d41\u91cf\u306f\u5287\u7684\u306b\u6e1b\u5c11\u3057\u305f\u6d41\u91cf\u306b\u8a2d\u5b9a\u3055\u308c\u307e\u3059\u3002\u3053\u3053\u3067\u306f\u3001\u308f\u305a\u304b4 mL\/min\u3067\u3059\u30023 mL\/min\u304c\u30bb\u30d7\u30bf\u30e0\u30d1\u30fc\u30b8\u3092\u901a\u904e\u3057\u3001\u6b8b\u308a\u306e1 mL\/min\u304c\u30ab\u30e9\u30e0\u306b\u5165\u308a\u307e\u3057\u305f\u3002\u6ce8\u5165\u306e\u9593\u3001\u6d41\u91cf\u304c\u5c11\u306a\u3044\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u306f\u30ab\u30e9\u30e0\u306b\u5165\u308b\u524d\u306b\u30e9\u30a4\u30ca\u30fc\u5185\u306b\u9577\u304f\u7559\u307e\u308a\u307e\u3059\u3002\u6ce8\u5165\u5f8c\u5341\u5206\u306a\u6642\u9593\u304c\u7d4c\u904e\u3059\u308b\u3068\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u304c\u958b\u3044\u3066\u6ce8\u5165\u53e3\u304c\u30d1\u30fc\u30b8\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u6301\u7d9a\u6642\u9593\u306f\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u30db\u30fc\u30eb\u30c9\u30bf\u30a4\u30e0\u3068\u3082\u547c\u3070\u308c\u3001\u5206\u6790\u7a2e\u306e\u6c17\u5316\u3068\u30ab\u30e9\u30e0\u3078\u306e\u79fb\u52d5\u304c\u6700\u5927\u9650\u306b\u304a\u3053\u306a\u308f\u308c\u308b\u306e\u306b\u5341\u5206\u306a\u9577\u3055\u3068\u306a\u308b\u3088\u3046\u306b\u8a08\u7b97\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3067\u306f\u3001\u3069\u3061\u3089\u306e\u6ce8\u5165\u624b\u6cd5\u3092\u4f7f\u7528\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u304b\uff1f\u3053\u308c\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u5185\u306e\u76ee\u7684\u306e\u5206\u6790\u7a2e\u306e\u6fc3\u5ea6\u3001\u691c\u51fa\u5668\u306e\u611f\u5ea6\u304a\u3088\u3073\u30e1\u30bd\u30c3\u30c9\u8981\u4ef6\u306b\u3088\u3063\u3066\u7570\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306f\u3001\u5206\u6790\u7a2e\u306e\u6fc3\u5ea6\u304c\u5341\u5206\u306b\u9ad8\u304f\u3001\u305d\u308c\u304c\u6a5f\u5668\u306b\u3088\u308b\u5e0c\u91c8\u304c\u8a31\u5bb9\u3067\u304d\u308b\u3046\u3048\u3001\u691c\u51fa\u9650\u754c\u3092\u6e80\u305f\u3059\u5834\u5408\u306b\u7406\u60f3\u7684\u3067\u3059\u3002\u6ce8\u5165\u53e3\u3092\u901a\u904e\u3059\u308b\u6d41\u91cf\u304c\u591a\u3044\u3068\u3001\u30d4\u30fc\u30af\u304c\u30b7\u30e3\u30fc\u30d7\u306b\u306a\u308b\u3068\u540c\u6642\u306b\u3001\u6709\u5bb3\u306a\u76f8\u4e92\u4f5c\u7528\u304c\u767a\u751f\u3059\u308b\u6642\u9593\u304c\u77ed\u7e2e\u3055\u308c\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u307b\u3068\u3093\u3069\u304c\u30d9\u30f3\u30c8\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u691c\u51fa\u9650\u754c\u306f\u306f\u308b\u304b\u306b\u9ad8\u304f\u306a\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u611f\u5ea6\u306e\u4f4e\u3044\u691c\u51fa\u5668\u3067\u306f\u554f\u984c\u306b\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u9ad8\u611f\u5ea6\u306e\u691c\u51fa\u5668\u3001\u3059\u306a\u308f\u3061\u3001ECD\u3084MS\/MS\u306a\u3069\u306f\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3092\u53ef\u80fd\u306b\u3057\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u5206\u6790\u7a2e\u306e\u6fc3\u5ea6\u304c\u975e\u5e38\u306b\u4f4e\u3044\u5834\u5408\u306f\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3092\u5b9f\u884c\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306f\u3001\u5fae\u91cf\u5206\u6790\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u3059\u3079\u3066\u306e\u6d41\u91cf\u304c\u30ab\u30e9\u30e0\u306b\u5165\u3063\u3066\u3044\u304f\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u5927\u90e8\u5206\u3092\u79fb\u9001\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u305f\u3060\u3057\u3001\u5206\u6790\u7a2e\u306e\u6fc3\u5ea6\u304c\u975e\u5e38\u306b\u4f4e\u3044\u5834\u5408\u306f\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3092\u5b9f\u884c\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306f\u3001\u5fae\u91cf\u5206\u6790\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u3059\u3079\u3066\u306e\u6d41\u91cf\u304c\u30ab\u30e9\u30e0\u306b\u5165\u3063\u3066\u3044\u304f\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u5927\u90e8\u5206\u3092\u79fb\u9001\u3067\u304d\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u30ab\u30e9\u30e0\u3078\u306e\u6d41\u91cf\u304c\u4f4e\u3044\u3068\u3001\u5438\u7740\u3068\u5206\u89e3\u306b\u3088\u3063\u3066\u6d3b\u6027\u306e\u3042\u308b\u5206\u6790\u7a2e\u304c\u5206\u89e3\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u62e1\u6563\u304c\u5897\u52a0\u3057\u3001\u30d0\u30f3\u30c9\u5e45\u304c\u5e83\u304c\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u63ee\u767a\u6027\u306e\u9ad8\u3044\u5206\u6790\u7a2e\u3067\u7279\u306b\u9855\u8457\u3067\u3042\u308a\u3001\u30d4\u30fc\u30af\u5e45\u304c\u5e83\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5206\u6790\u306b\u9069\u5207\u306a\u6ce8\u5165\u65b9\u6cd5\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u304c\u3001\u6ce8\u5165\u30d1\u30e9\u30e1\u30fc\u30bf\u3092\u6700\u9069\u5316\u3059\u308b\u3053\u3068\u3082\u91cd\u8981\u3067\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u5206\u6790\u7a2e\u306e\u79fb\u52d5\u3068\u6ce8\u5165\u9593\u306e\u518d\u73fe\u6027\u306e\u4e21\u65b9\u3092\u6700\u5927\u5316\u3067\u304d\u307e\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u304a\u3088\u3073\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306e\u6700\u9069\u5316\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001\u4ee5\u4e0b\u306e\u30ea\u30bd\u30fc\u30b9\u306b\u30a2\u30af\u30bb\u30b9\u3059\u308b\u304b\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\" target=\"_blank\" rel=\"noreferrer noopener\">restek.com<\/a>\u306b\u30a2\u30af\u30bb\u30b9\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u30b9\u30d7\u30ea\u30c3\u30c8\u3068\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u306f\u3069\u3061\u3089\u3082\u6700\u3082\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u308bGC\u6ce8\u5165\u6cd5\u3067\u3059\u3002\u3067\u3082\u3001\u3069\u3061\u3089\u3092\u9078\u3076\u3079\u304d\u3067\u3057\u3087\u3046\u304b\uff1f\u3053\u306e\u52d5\u753b\u3092\u3054\u89a7\u3044\u305f\u3060\u304d\u3001\u3053\u306e\u4e8c\u3064\u306e\u6ce8\u5165\u6cd5\u306e\u52d5\u4f5c\u3092\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002<\/p>\n","protected":false},"author":11,"featured_media":41285,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[774],"tags":[2800],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[2814,2814],"class_list":["post-42381","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-ja","tag-topaz-liners"],"acf":[],"taxonomy_info":{"category":[{"value":774,"label":"\u52d5\u753b"}],"post_tag":[{"value":2800,"label":"Topaz Liners"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3658-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":774,"name":"\u52d5\u753b","slug":"videos-ja","term_group":0,"term_taxonomy_id":774,"taxonomy":"category","description":"","parent":0,"count":139,"filter":"raw","cat_ID":774,"category_count":139,"category_description":"","cat_name":"\u52d5\u753b","category_nicename":"videos-ja","category_parent":0}],"tag_info":[{"term_id":2800,"name":"Topaz Liners","slug":"topaz-liners","term_group":0,"term_taxonomy_id":2800,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw"}],"authors":[{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""},{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42381","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=42381"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42381\/revisions"}],"predecessor-version":[{"id":81032,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42381\/revisions\/81032"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/41285"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=42381"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=42381"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=42381"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=42381"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=42381"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=42381"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=42381"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=42381"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=42381"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}