{"id":42390,"date":"2020-07-08T05:00:00","date_gmt":"2020-07-08T05:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-coated-blade-spray-tandem-ms-for-rapid-screening-and-quantitation-of-drugs-in-oral-fluids\/"},"modified":"2026-01-13T21:55:52","modified_gmt":"2026-01-13T21:55:52","slug":"japanese-coated-blade-spray-tandem-ms-for-rapid-screening-and-quantitation-of-drugs-in-oral-fluids","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/videos-ja\/cfav3571-ja\/japanese-coated-blade-spray-tandem-ms-for-rapid-screening-and-quantitation-of-drugs-in-oral-fluids","title":{"rendered":"Coated Blade Spray-\u30bf\u30f3\u30c7\u30e0\u8cea\u91cf\u5206\u6790\u8a08\u306b\u3088\u308b\u53e3\u8154\u6db2\u4e2d\u85ac\u7269\u306e\u8fc5\u901f\u306a\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3068\u5b9a\u91cf"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Coated Blade Spray-Tandem MS for Rapid Screening &amp; Quantitation of Drugs in Oral Fluids\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/-8IKhC4WFF4?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u65e5\u672c\u8a9e\u5b57\u5e55\u3092\u8868\u793a\u3067\u304d\u307e\u3059<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u5185\u5bb9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Coated Blade Spray\u306f\u3001\u8fc5\u901f\u306a\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3068\u5b9a\u91cf\u3092\u76ee\u7684\u3068\u3057\u3066\u8cea\u91cf\u5206\u6790\u8a08\u306b\u76f4\u63a5\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9\u3067\u304d\u308b\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u30c7\u30d0\u30a4\u30b9\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">CBS\u306f\u3001\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u3055\u308c\u305f\u5c0f\u3055\u306a\u5200\u306e\u5f62\u72b6\u3092\u3057\u305f\u30b9\u30c6\u30f3\u30ec\u30b9\u92fc\u677f\u3067\u3059\u3002\u3053\u306eCBS\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u4e2d\u306b\u5b58\u5728\u3059\u308b\u4f4e\u5206\u5b50\u5316\u5408\u7269\u3092\u8fc5\u901f\u306b\u6fc3\u7e2e\u3067\u304d\u308b\u975e\u5e38\u306b\u8584\u3044SPME\u88ab\u819c\u3092\u6709\u3057\u3066\u304a\u308a\u3001\u7d50\u679c\u3068\u3057\u3066\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u306b\u3088\u308b\u30b5\u30f3\u30d7\u30eb\u306e\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u304c\u3082\u305f\u3089\u3055\u308c\u3001\u6a5f\u5668\u306e\u6c5a\u67d3\u3092\u5f15\u304d\u8d77\u3053\u3059\u53ef\u80fd\u6027\u306e\u3042\u308b\u5869\u3084\u9ad8\u5206\u5b50\u306e\u62bd\u51fa\u3092\u9632\u3050\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u30dd\u30b9\u30bf\u30fc\u30d3\u30c7\u30aa\u3067\u306f\u3001\u30bf\u30f3\u30c7\u30e0\u8cea\u91cf\u5206\u6790\u8a08\u3068CBS\u306e\u7d44\u5408\u305b\u306b\u3088\u308b\u3001\u53e3\u8154\u6db2\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u8907\u6570\u306e\u898f\u5236\u85ac\u7269\u3068\u30da\u30a4\u30f3\u30de\u30cd\u30b8\u30e1\u30f3\u30c8\u7528\u306e\u85ac\u306e\u8fc5\u901f\u306a\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3068\u5b9a\u91cf\u306e\u53ef\u80fd\u6027\u306b\u3064\u3044\u3066\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u79c1\u305f\u3061\u3068\u3064\u306a\u304c\u308a\u307e\u3057\u3087\u3046<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">YouTube:&nbsp;<a href=\"https:\/\/www.youtube.com\/user\/RestekCorp\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.youtube.com\/user\/RestekCorp<\/a>&nbsp;<br>LinkedIn:&nbsp;<a href=\"https:\/\/www.linkedin.com\/company\/restek-corporation\/\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.linkedin.com\/company\/restek-corporation\/<\/a><br>Facebook:&nbsp;<a href=\"https:\/\/www.facebook.com\/RestekCorporation\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.facebook.com\/RestekCorporation<\/a>&nbsp;<br>Twitter:&nbsp;<a href=\"https:\/\/www.twitter.com\/Restek\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.twitter.com\/Restek<\/a>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Coated Blade Spray\u306f\u3001\u8fc5\u901f\u306a\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3068\u5b9a\u91cf\u3092\u76ee\u7684\u306b\u8cea\u91cf\u5206\u6790\u8a08\u306b\u76f4\u63a5\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9\u53ef\u80fd\u306a\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u30c7\u30d0\u30a4\u30b9\u3067\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":40919,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[774],"tags":[],"industries-application":[2266],"post-badge":[],"resource-type":[],"product-library":[2586,2555],"resource-technique":[],"ppma_author":[414],"class_list":["post-42390","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-ja","industries-application-clinical-ja","product-library-coated-blade-spray-ja","product-library-sample-preparation-products-ja"],"acf":[],"taxonomy_info":{"category":[{"value":774,"label":"\u52d5\u753b"}],"industries-application":[{"value":2266,"label":"\u81e8\u5e8a"}],"product-library":[{"value":2586,"label":"\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u30d6\u30ec\u30fc\u30c9\u30b9\u30d7\u30ec\u30fc"},{"value":2555,"label":"\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-CFAV3571-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":774,"name":"\u52d5\u753b","slug":"videos-ja","term_group":0,"term_taxonomy_id":774,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":774,"category_count":138,"category_description":"","cat_name":"\u52d5\u753b","category_nicename":"videos-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42390","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=42390"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42390\/revisions"}],"predecessor-version":[{"id":81025,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42390\/revisions\/81025"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/40919"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=42390"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=42390"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=42390"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=42390"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=42390"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=42390"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=42390"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=42390"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=42390"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}