{"id":42447,"date":"2020-10-13T18:30:00","date_gmt":"2020-10-13T18:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/gc-particle-traps-japan\/"},"modified":"2026-04-07T01:40:24","modified_gmt":"2026-04-07T01:40:24","slug":"gc-particle-traps-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3592-ja\/gc-particle-traps-japan","title":{"rendered":"PLOT\u30ab\u30e9\u30e0\u306e\u6d41\u51fa\u7c92\u5b50\u5bfe\u7b56\u3068\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u63a5\u7d9a\u6cd5"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"GC Particle Traps\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/Yt6Nciq1lEE?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"512\" height=\"373\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1.png\" alt=\"\" class=\"wp-image-29853\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1.png 512w, https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1-300x219.png 300w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"447\" height=\"528\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12.png\" alt=\"\" class=\"wp-image-29859\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12.png 447w, https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12-254x300.png 254w\" sizes=\"auto, (max-width: 447px) 100vw, 447px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">YouTube\u753b\u9762\u53f3\u4e0b\u306b\u3042\u308b\u8a2d\u5b9a\u30dc\u30bf\u30f3\u2699\u304b\u3089Subtitles\/CC\u3092\u9078\u3073\u3001Japanese\u306b\u30c1\u30a7\u30c3\u30af\u3092\u5165\u308c\u308b\u3068\u65e5\u672c\u8a9e\u5b57\u5e55\u3042\u308a\u3067\u52d5\u753b\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u6982\u8981<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6700\u65b0\u306ePLOT\u30ab\u30e9\u30e0\u306f\u975e\u5e38\u306b\u5b89\u5b9a\u3057\u3066\u304a\u308a\u3001\u7c92\u5b50\u306e\u6d41\u51fa\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u8f38\u9001\u4e2d\u3084\u30ac\u30b9\u6d41\u91cf\u306e\u5909\u5316\u3001\u30d0\u30eb\u30d6\u306e\u5207\u308a\u66ff\u3048\u6642\u306b\u306f\u3001\u30ab\u30e9\u30e0\u304b\u3089\u7c92\u5b50\u304c\u5916\u308c\u6d41\u51fa\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u306f\u3001PLOT\u30ab\u30e9\u30e0\u304b\u3089\u6d41\u51fa\u3057\u305f\u7c92\u5b50\u3092\u6355\u6349\u3059\u308b\u305f\u3081\u306b\u8a2d\u8a08\u3055\u308c\u305fPDMS\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u30ab\u30e9\u30e0\u3067\u3059\u3002\u3053\u306eRestek Tip\u3067\u306f\u3001Press-Tight\u30b3\u30cd\u30af\u30bf\u3092\u4f7f\u3063\u3066\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u3092PLOT\u30ab\u30e9\u30e0\u306b\u63a5\u7d9a\u3059\u308b\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Restek\u63a8\u5968\u30c4\u30fc\u30eb\u3068\u90e8\u54c1<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1179\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/search?Ntt=PLOT+column+particle+trap&amp;Ns=bestMatch\" rel=\"noreferrer noopener\">Restek&#8217;s PLOT Column Particle Trap<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/pcss1163-ja\/resteks-plot-column-family-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/pcss1163-ja\/resteks-plot-column-family-japan\">Restek&#8217;s PLOT Column Family<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1571\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/c\/1571\" rel=\"noreferrer noopener\">Universal Press-Tight Connectors<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/p\/20445\" target=\"_blank\" rel=\"noreferrer noopener\">Polyimide Resin<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Restek\u306b\u306f\u3053\u3061\u3089\u304b\u3089\u3082\u30a2\u30af\u30bb\u30b9\u3067\u304d\u307e\u3059<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">YouTube:&nbsp;<a href=\"https:\/\/www.youtube.com\/user\/RestekCorp\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.youtube.com\/user\/RestekCorp<\/a>&nbsp;<br>LinkedIn:&nbsp;<a href=\"https:\/\/www.linkedin.com\/company\/restek-corporation\/\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.linkedin.com\/company\/restek-corporation\/<\/a><br>Facebook:&nbsp;<a href=\"https:\/\/www.facebook.com\/RestekCorporation\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.facebook.com\/RestekCorporation<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u73fe\u5728\u306e\u30dd\u30fc\u30e9\u30b9\u30ec\u30a4\u30e4\u30fc\u30aa\u30fc\u30d7\u30f3\u30c1\u30e5\u30fc\u30d6\u30e9\u30fc\u30ab\u30e9\u30e0\u2014\u307e\u305f\u306fPLOT\u30ab\u30e9\u30e0\u2014\u306f\u3001\u7c92\u5b50\u306e\u653e\u51fa\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u9a5a\u304f\u3079\u304d\u5b89\u5b9a\u6027\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002\u305d\u308c\u306b\u3082\u304b\u304b\u308f\u3089\u305a\u3001\u8f38\u9001\u4e2d\u3001\u30ac\u30b9\u6d41\u91cf\u306e\u5909\u5316\u3001\u307e\u305f\u306f\u30d0\u30eb\u30d6\u306e\u5207\u308a\u66ff\u3048\u3068\u3044\u3063\u305f\u3053\u3068\u3067\u3001\u4e00\u90e8\u306e\u7c92\u5b50\u306f\u3001\u30ab\u30e9\u30e0\u304b\u3089\u5916\u308c\u3066\u653e\u51fa\u3055\u308c\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u7c92\u5b50\u306f\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306b\u30b9\u30d1\u30a4\u30af\u30ce\u30a4\u30ba\u3092\u5f15\u304d\u8d77\u3053\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u3001\u5834\u5408\u306b\u3088\u3063\u3066\u306f\u5207\u308a\u66ff\u3048\u30d0\u30eb\u30d6\u306b\u640d\u50b7\u3092\u4e0e\u3048\u3001\u6642\u9593\u3068\u8cbb\u7528\u306e\u304b\u304b\u308b\u88ab\u5bb3\u3092\u5f15\u304d\u8d77\u3053\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306eRestek Tip\u3067\u306f\u3001GC PLOT\u30ab\u30e9\u30e0\u3092\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u306b\u63a5\u7d9a\u3059\u308b\u65b9\u6cd5\u3092\u898b\u3066\u3044\u304d\u307e\u3059\u3002\u3053\u3053\u3067\u306fPress-Tight\u30b3\u30cd\u30af\u30bf\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002\u307e\u305a\u3001\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u3068\u306f\u4f55\u304b\u3001\u305d\u3057\u3066\u3069\u306e\u3088\u3046\u306b\u6a5f\u80fd\u3059\u308b\u304b\u3092\u898b\u3066\u307f\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u306f\u3001PDMS\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u30ab\u30e9\u30e0\u3067\u3001\u3042\u3089\u3086\u308b\u7c92\u5b50\u3092\u6355\u6349\u3059\u308b\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u7c92\u5b50\u306f\u3001PLOT\u30ab\u30e9\u30e0\u304b\u3089\u6d41\u51fa\u3057\u3066\u304d\u307e\u3059\u3002\u30d0\u30eb\u30d6\u306a\u3069\u306e\u5927\u6c17\u5727\u51fa\u53e3\u3084\u3001\u30d5\u30ed\u30fc\u30b9\u30a4\u30c3\u30c1\u30f3\u30b0\u30c7\u30d0\u30a4\u30b9\u3001\u3055\u3089\u306b\u306fFID\u304a\u3088\u3073TCD\u691c\u51fa\u5668\u306e\u5834\u5408\u3001PLOT\u30ab\u30e9\u30e0\u3068\u540c\u3058\u5185\u5f84\u306e0.5 m\u304b\u30892 m\u306e\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u30ab\u30e9\u30e0\u3067\u5341\u5206\u3067\u3059\u3002\u4e00\u65b9\u3001\u8cea\u91cf\u5206\u6790\u691c\u51fa\u5668\u306e\u5834\u5408\u3001\u30ab\u30e9\u30e0\u9577\u3055\u306f5\u30e1\u30fc\u30c8\u30eb\u3067\u3001\u5185\u5f84\u306f0.18\u307e\u305f\u306f0.25\u30df\u30ea\u30e1\u30fc\u30c8\u30eb\u306e\u3082\u306e\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u7c92\u5b50\u306e\u6355\u6349\u306b\u5f79\u7acb\u3064\u3060\u3051\u3067\u306a\u304f\u3001MS\u3078\u306e\u6d41\u91cf\u306e\u7ba1\u7406\u306b\u3082\u5f79\u7acb\u3061\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u3092\u53d6\u308a\u4ed8\u3051\u308b\u524d\u306b\u3001PLOT\u30ab\u30e9\u30e0\u3092\u691c\u51fa\u5668\u304b\u3089\u5916\u3057\u3066\u304a\u304d\u3001\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u304c\u63a8\u5968\u3059\u308b\u3088\u308a\u30823\u500d\u9ad8\u3044\u6d41\u91cf\u3067PLOT\u30ab\u30e9\u30e0\u3092\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3057\u307e\u3059\u30025\u00b0C\/min\u3067\u6607\u6e29\u3059\u308b\u3088\u3046\u306bGC\u30aa\u30fc\u30d6\u30f3\u3092\u30d7\u30ed\u30b0\u30e9\u30df\u30f3\u30b0\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u305d\u3057\u3066\u30ab\u30e9\u30e0\u306e\u6700\u9ad8\u6e29\u5ea6\u307e\u3067\u4e0a\u3052\u307e\u3059\u3002\u5230\u9054\u3057\u305f\u3089\u3001\u3053\u306e\u6e29\u5ea6\u3092\u5c11\u306a\u304f\u3068\u30821\u6642\u9593\u4fdd\u6301\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u7de9\u3044\u7c92\u5b50\u304c\u30ab\u30e9\u30e0\u304b\u3089\u6d41\u51fa\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u304c\u5b8c\u4e86\u3057\u305f\u306e\u3067\u3001PLOT\u30ab\u30e9\u30e0\u3068\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u30ab\u30e9\u30e0\u306e\u7aef\u3092\u30ab\u30c3\u30c8\u3057\u307e\u3059\u3002\u307e\u3063\u3059\u3050\u306a\u30b9\u30af\u30a8\u30a2\u30ab\u30c3\u30c8\u3092\u5b9f\u73fe\u3059\u308b\u305f\u3081\u306b\u3001\u30bb\u30e9\u30df\u30c3\u30af\u30ab\u30c3\u30bf\u30fc\u3092\u4f7f\u7528\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u3001Press-Tight\u30b3\u30cd\u30af\u30bf\u3092\u6b63\u3057\u304f\u63a5\u7d9a\u3059\u308b\u305f\u3081\u306b\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u6b21\u306b\u3001PLOT\u30ab\u30e9\u30e0\u3092\u8efd\u304f\u305f\u305f\u304f\u304b\u3001\u307e\u305f\u306f\u3001\u30ab\u30e9\u30e0\u306e\u7aef\u3092\u6307\u3067\u5f3e\u3044\u3066\u3001\u7de9\u3093\u3060\u7c92\u5b50\u3092\u53d6\u308a\u9664\u304d\u307e\u3059\u3002\u7cf8\u304f\u305a\u306e\u51fa\u306a\u3044\u5e03\u3067PLOT\u30ab\u30e9\u30e0\u3068\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u306e\u7aef\u3092\u3075\u304d\u53d6\u308a\u307e\u3059\u304c\u3001\u6307\u306e\u6cb9\u3084\u305d\u306e\u4ed6\u306e\u4e0d\u7d14\u7269\u3092\u53d6\u308a\u9664\u304f\u305f\u3081\u306b\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\u307e\u305f\u306f\u30a4\u30bd\u30d7\u30ed\u30d1\u30ce\u30fc\u30eb\u3067\u6e7f\u3089\u305b\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b21\u306b\u3001Press-Tight\u30b3\u30cd\u30af\u30bf\u3092\u4f7f\u7528\u3057\u3066\u30ab\u30e9\u30e0\u3092\u63a5\u7d9a\u3057\u307e\u3059\u3002\u30b3\u30cd\u30af\u30bf\u3092\u7247\u624b\u3067\u6301\u3061\u306a\u304c\u3089\u3001PLOT\u30ab\u30e9\u30e0\u306e\u7aef\u304c\u3057\u3063\u304b\u308a\u3068\u56fa\u5b9a\u3055\u308c\u308b\u307e\u3067\u3001\u30b3\u30cd\u30af\u30bf\u306b\u3086\u3063\u304f\u308a\u3068\u633f\u5165\u3057\u307e\u3059\u3002\u5f37\u304f\u62bc\u3057\u3059\u304e\u308b\u3068\u3001\u30ab\u30e9\u30e0\u306e\u7aef\u304c\u3064\u3076\u308c\u308b\u306e\u3067\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u6b21\u306b\u3001\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u3092\u4f7f\u7528\u3057\u3066\u3053\u306e\u30d7\u30ed\u30bb\u30b9\u3092\u7e70\u308a\u8fd4\u3059\u3060\u3051\u3067\u3059\u3002\u30b3\u30cd\u30af\u30bf\u306e\u3082\u3046\u4e00\u65b9\u306e\u7aef\u306b\u305d\u3063\u3068\u633f\u5165\u3057\u307e\u3059\u3002\u30ab\u30e9\u30e0\u306e\u7aef\u304c\u5727\u7e2e\u3055\u308c\u3066\u3067\u304d\u308b\u5207\u308c\u76ee\u306e\u306a\u3044\u8336\u8272\u306e\u30ea\u30f3\u30b0\u304c\u3001\u30b3\u30cd\u30af\u30bf\u5185\u90e8\u3067\u306e\u9069\u5207\u306a\u63a5\u7d9a\u306e\u6307\u6a19\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e21\u65b9\u306e\u30b7\u30fc\u30eb\u3092\u76ee\u8996\u691c\u67fb\u3057\u3001\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3092\u4f7f\u7528\u3057\u3066\u3001\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u3092\u304a\u3053\u306a\u3044\u307e\u3059\u3002\u6f0f\u308c\u306b\u6c17\u3065\u3044\u305f\u5834\u5408\u306f\u3001\u554f\u984c\u306e\u30ab\u30e9\u30e0\u3092\u5c11\u3057\u5207\u308a\u3001\u518d\u5ea6\u63a5\u7d9a\u3057\u307e\u3059\u3002\u3053\u308c\u3067\u5b8c\u4e86\u3067\u3059\u3002\u6e96\u5099\u304c\u6574\u3044\u307e\u3057\u305f\u3002\u30ab\u30e9\u30e0\u6d41\u91cf\u3092\u901a\u5e38\u306b\u623b\u3059\u3068\u3001\u5206\u6790\u3092\u958b\u59cb\u3059\u308b\u6e96\u5099\u304c\u6574\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u304a\u5f79\u306b\u7acb\u3066\u305f\u3089\u3001\u3044\u3044\u306d\u3068\u30c1\u30e3\u30f3\u30cd\u30eb\u767b\u9332\u3092\u3088\u308d\u3057\u304f\u304a\u9858\u3044\u3057\u307e\u3059\u3002\u3053\u306eRestek Tip\u306b\u3054\u53c2\u52a0\u3044\u305f\u3060\u304d\u3042\u308a\u304c\u3068\u3046\u3054\u3056\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>PLOT\u30ab\u30e9\u30e0\u304b\u3089\u306e\u7c92\u5b50\u6d41\u51fa\u3092\u9632\u3050\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u306e\u5f79\u5272\u3068\u3001Press-Tight\u30b3\u30cd\u30af\u30bf\u3092\u7528\u3044\u305f\u63a5\u7d9a\u624b\u9806\u3092\u8a73\u3057\u304f\u89e3\u8aac\u3057\u307e\u3059\u3002\u8f38\u9001\u6642\u3084\u30d0\u30eb\u30d6\u5207\u308a\u66ff\u3048\u6642\u306e\u7c92\u5b50\u30ea\u30b9\u30af\u5bfe\u7b56\u3084GC\/MS\u63a5\u7d9a\u6642\u306e\u6700\u9069\u306a\u30ab\u30e9\u30e0\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u65b9\u6cd5\u3082\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":41051,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[774],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[2814],"class_list":["post-42447","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-ja"],"acf":[],"taxonomy_info":{"category":[{"value":774,"label":"\u52d5\u753b"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3592-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":774,"name":"\u52d5\u753b","slug":"videos-ja","term_group":0,"term_taxonomy_id":774,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":774,"category_count":138,"category_description":"","cat_name":"\u52d5\u753b","category_nicename":"videos-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42447","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=42447"}],"version-history":[{"count":7,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42447\/revisions"}],"predecessor-version":[{"id":86574,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42447\/revisions\/86574"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/41051"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=42447"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=42447"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=42447"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=42447"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=42447"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=42447"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=42447"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=42447"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=42447"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}