{"id":42461,"date":"2018-11-20T05:00:00","date_gmt":"2018-11-20T05:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/gc-troubleshooting-the-problem-with-gas-leaks\/"},"modified":"2026-01-28T15:53:26","modified_gmt":"2026-01-28T15:53:26","slug":"gc-troubleshooting-the-problem-with-gas-leaks","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/videos\/gnav3603\/gc-troubleshooting-the-problem-with-gas-leaks","title":{"rendered":"GC Troubleshooting\u2014The Problem with Gas Leaks"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"GC Troubleshooting\u2014The Problem with Gas Leaks\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/2mOEk90sDkw?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Description<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Gas leaks are one of the most prevalent and troublesome problems when doing gas chromatography. They can negatively affect&nbsp;your chromatography in a number of ways, and we share some examples here. We also offer a few suggestions on when and how to leak check.&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Additional Resources<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/articles\/leak-checking-a-gc-system\" target=\"_blank\" rel=\"noopener\">Leak Checking a GC System<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Restek Recommended Tools &amp; Parts<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/p\/28500\" target=\"_blank\" rel=\"noopener\">Electronic Leak Detector<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transcript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hello, chromatographers, and welcome to another Restek Tip. Let\u2019s talk about the importance of leak checking our gas chromatographic system. It\u2019s advice that you\u2019re given all the time \u2013 to leak check, and leak check, and leak check again. But why? Why are we given this advice all the time? Well, the fact of the matter is with a high-pressure instrument and numerous seals and connections throughout, leaks can always crop up in a GC instrument. So, we want to be checking for them on a regular basis. But then the question is, well, so what? What\u2019s the big deal if I do have a leak? And the truth of the matter is it is a big deal. And in a few different ways.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">First, if we have a leak, we\u2019re disrupting our flow path. That can result in loss of sample, poor chromatography, or other issues. So, we certainly want to eliminate those in order to get the best chromatography possible. But there\u2019s another problem as well. Leaks can allow materials to get introduced into the system as well, especially compounds like oxygen. Why is oxygen a big deal? Well, oxygen is a pretty effective column killer and can damage many gas chromatographic columns. So, we certainly want to have a leak-tight system to get the most lifetime out of our GC columns.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">What do we do about all of this? Well, we leak check regularly. And ideally, we use an electronic leak detector. We want to avoid liquid leak detectors. Those liquid materials can get actually sucked into the instrument through those leaks and can contribute to contamination. So, that\u2019s a little bit of why leak checking is so important. And again, the idea of making sure that we use an electronic leak detector regularly to look for those leaks throughout our instrument. Thanks very much for joining us for this Restek Tip.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Watch out for gas leaks when doing gas chromatography. Find out about the problems they can cause in this Restek Tip video.<\/p>\n","protected":false},"author":11,"featured_media":41100,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[8],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[569],"product-library":[2372,2387],"resource-technique":[2294],"ppma_author":[414],"class_list":["post-42461","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos","resource-type-troubleshooting","product-library-gas-chromatography-products","product-library-instrument-supplies-tools","resource-technique-gas-chromatography-gc"],"acf":[],"taxonomy_info":{"category":[{"value":8,"label":"Videos"}],"resource-type":[{"value":569,"label":"Troubleshooting"}],"product-library":[{"value":2372,"label":"Gas Chromatography Products"},{"value":2387,"label":"Instrument Supplies &amp; Tools"}],"resource-technique":[{"value":2294,"label":"Gas Chromatography (GC)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3603-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"Videos","slug":"videos","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":8,"category_count":138,"category_description":"","cat_name":"Videos","category_nicename":"videos","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42461","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=42461"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42461\/revisions"}],"predecessor-version":[{"id":85317,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42461\/revisions\/85317"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/41100"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=42461"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=42461"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=42461"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=42461"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=42461"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=42461"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=42461"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=42461"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=42461"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}