{"id":42465,"date":"2018-02-22T05:00:00","date_gmt":"2018-02-22T05:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/how-to-get-equivalent-gc-ms-results-faster-japan\/"},"modified":"2025-12-31T14:54:35","modified_gmt":"2025-12-31T14:54:35","slug":"how-to-get-equivalent-gc-ms-results-faster-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3608-ja\/how-to-get-equivalent-gc-ms-results-faster-japan","title":{"rendered":"GC\u5206\u6790\u3092\u9ad8\u901f\u5316\u3059\u308b\u9769\u65b0\u7684\u306a\u65b9\u6cd5<br><em>EZ<\/em>GC Method Translator\u3068GC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u30ad\u30c3\u30c8\u306e\u6709\u52b9\u6d3b\u7528"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"How to Get Equivalent GC-MS Results Faster Using the EZGC Method Translator and GC Accelerator Kit\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/qRUciio48WE?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"512\" height=\"373\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1.png\" alt=\"\" class=\"wp-image-29853\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1.png 512w, https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1-300x219.png 300w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"447\" height=\"528\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12.png\" alt=\"\" class=\"wp-image-29859\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12.png 447w, https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12-254x300.png 254w\" sizes=\"auto, (max-width: 447px) 100vw, 447px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">YouTube\u753b\u9762\u53f3\u4e0b\u306b\u3042\u308b\u8a2d\u5b9a\u30dc\u30bf\u30f3\u2699\u304b\u3089Subtitles\/CC\u3092\u9078\u3073\u3001Japanese\u306b\u30c1\u30a7\u30c3\u30af\u3092\u5165\u308c\u308b\u3068\u65e5\u672c\u8a9e\u5b57\u5e55\u3042\u308a\u3067\u52d5\u753b\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u6982\u8981<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b5\u30a4\u30ba\u306e\u5c0f\u3055\u3044\u30ab\u30e9\u30e0\u306b\u5207\u308a\u66ff\u3048\u3001\u5206\u6790\u6761\u4ef6\u3092\u8abf\u6574\u3059\u308b\u3053\u3068\u3067\u5206\u6790\u6642\u9593\u306f\u77ed\u7e2e\u53ef\u80fd\u3067\u3059\u3002GC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u30ad\u30c3\u30c8\u3092\u4f7f\u7528\u3057\u3066\u30aa\u30fc\u30d6\u30f3\u4f53\u7a4d\u3092\u5c0f\u3055\u304f\u3057\u3001<em>EZ<\/em>GC Method Translator\u3092\u4f7f\u3063\u3066\u65e2\u5b58\u306e\u30e1\u30bd\u30c3\u30c9\u3092\u52b9\u7387\u306e\u9ad8\u3044\u30ab\u30e9\u30e0\u7528\u306b\u30b9\u30b1\u30fc\u30eb\u30c0\u30a6\u30f3\u3057\u307e\u3059\u3002\u3053\u306e\u4e8c\u3064\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u65b9\u6cd5\u306b\u3088\u3063\u3066\u3001\u5206\u6790\u306f\u9ad8\u901f\u5316\u3055\u308c\u3001\u5206\u6790\u6642\u9593\u3092\u77ed\u7e2e\u3057\u306a\u304c\u3089\u3082\u4eca\u307e\u3067\u3068\u540c\u3058\u5206\u6790\u7d50\u679c\u3092\u5f97\u308b\u3053\u3068\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u305d\u306e\u4ed6\u306e\u30ea\u30bd\u30fc\u30b9<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/ez.restek.com\/ezgc-mtfc\/en\" target=\"_blank\" rel=\"noopener\"><em>EZ<\/em>GC Method Translator<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Restek\u63a8\u5968\u30c4\u30fc\u30eb\u3068\u90e8\u54c1<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/p\/23849\" target=\"_blank\" rel=\"noopener\">GC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u30ad\u30c3\u30c8<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Restek\u306b\u306f\u3053\u3061\u3089\u304b\u3089\u3082\u30a2\u30af\u30bb\u30b9\u3067\u304d\u307e\u3059<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">YouTube:&nbsp;<a href=\"https:\/\/www.youtube.com\/user\/RestekCorp\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.youtube.com\/user\/RestekCorp<\/a>&nbsp;<br>LinkedIn:&nbsp;<a href=\"https:\/\/www.linkedin.com\/company\/restek-corporation\/\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.linkedin.com\/company\/restek-corporation\/<\/a><br>Facebook:&nbsp;<a href=\"https:\/\/www.facebook.com\/RestekCorporation\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.facebook.com\/RestekCorporation<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306e<em>EZ<\/em>GC Method Translator\u3068GC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u30ad\u30c3\u30c8\u3092\u4f7f\u7528\u3057\u3066\u3001\u4eca\u307e\u3067\u3068\u540c\u7b49\u306eGC-MS\u7d50\u679c\u3092\u3088\u308a\u901f\u304f\u5f97\u308b\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u30d3\u30c7\u30aa\u3067\u3054\u7d39\u4ecb\u3059\u308b\u306e\u306f\u3001GC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u30ad\u30c3\u30c8\u3068<em>EZ<\/em>GC Method Translator\u3092\u7d44\u307f\u5408\u308f\u305b\u3066\u3001\u30b9\u30b1\u30fc\u30eb\u30c0\u30a6\u30f3\u3057\u305f\u30ab\u30e9\u30e0\u3067\u52b9\u7387\u5316\u3092\u56f3\u308a\u3064\u3064\u65e2\u5b58\u306e\u30e1\u30bd\u30c3\u30c9\u3067\u540c\u69d8\u306e\u5206\u6790\u7d50\u679c\u3092\u5f97\u308b\u65b9\u6cd5\u3067\u3059\u3002\u3053\u306e\u65b9\u6cd5\u306f\u5206\u6790\u6642\u9593\u3092\u77ed\u7e2e\u3057\u306a\u304c\u3089\u3082\u3001\u4eca\u307e\u3067\u3068\u540c\u69d8\u306e\u5206\u6790\u7d50\u679c\u3092\u3088\u308a\u65e9\u304f\u5f97\u308b\u3053\u3068\u3092\u53ef\u80fd\u306b\u3059\u308b\u3001\u753b\u671f\u7684\u3067\u30b7\u30f3\u30d7\u30eb\u306a\u624b\u6bb5\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3069\u3093\u306aGC\u30ab\u30e9\u30e0\u3067\u3082\u3001\u5185\u5f84\uff08ID\uff09\u3092\u5c0f\u3055\u304f\u3001\u819c\u539a\u3092\u8584\u304f\u3001\u30ab\u30e9\u30e0\u9577\u3092\u77ed\u304f\u3059\u308c\u3070\u3001\u5206\u6790\u306f\u9ad8\u901f\u5316\u3055\u308c\u307e\u3059\u3002\u5185\u5f84\u304c\u5c0f\u3055\u304f\u819c\u539a\u304c\u8584\u3044\u3068\u30ab\u30e9\u30e0\u52b9\u7387\u304c\u6539\u5584\u3055\u308c\u308b\u306e\u3067\u3001\u30d4\u30fc\u30af\u5e45\u306f\u72ed\u304f\u306a\u308a\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u76f8\u5bfe\u30d4\u30fc\u30af\u5206\u96e2\u304c\u7dad\u6301\u3055\u308c\u3001\u5206\u6790\u6642\u9593\u306f\u77ed\u7e2e\u3055\u308c\u307e\u3059\u3002\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3092\u5909\u66f4\u3059\u308b\u3068\u304d\u306b\u91cd\u8981\u306a\u306e\u306f\u3001\u5185\u5f84\u3068\u819c\u539a\u304c\u6bd4\u4f8b\u3059\u308b\u3088\u3046\u306b\u8abf\u6574\u3057\u3066\u3001\u76f8\u6bd4\u3092\u5909\u3048\u306a\u3044\u3053\u3068\u3067\u3059\u3002\u3055\u3089\u306b\u30ab\u30e9\u30e0\u52b9\u7387\u3092\u6539\u5584\u3057\u305f\u3044\u5834\u5408\u306b\u306f\u3001\u30ab\u30e9\u30e0\u9577\u3092\u30aa\u30ea\u30b8\u30ca\u30eb\u3088\u308a\u3082\u77ed\u304f\u3057\u307e\u3059\u3002\u30ab\u30e9\u30e0\u52b9\u7387\u3092\u5411\u4e0a\u3055\u305b\u308b\u3068\u3001\u30e1\u30fc\u30c8\u30eb\u3042\u305f\u308a\u306e\u6bb5\u6570\u306f\u591a\u304f\u306a\u308a\u307e\u3059\u304c\u3001\u6bb5\u6570\u306e\u7dcf\u6570\u306f\u30aa\u30ea\u30b8\u30ca\u30eb\u306e\u307e\u307e\u304c\u671b\u307e\u3057\u3044\u306e\u3067\u3001\u6700\u7d42\u7684\u306a\u30ab\u30e9\u30e0\u9577\u306f\u77ed\u304f\u306a\u308a\u307e\u3059\u3002\u305f\u3060\u3001\u30ab\u30e9\u30e0\u304c\u9069\u5207\u306b\u30b9\u30b1\u30fc\u30eb\u30c0\u30a6\u30f3\u3055\u308c\u305f\u3068\u3057\u3066\u3082\u3001\u305d\u308c\u3060\u3051\u3067\u3088\u308a\u65e9\u304f\u540c\u3058\u7d50\u679c\u3092\u5f97\u308b\u3053\u3068\u306f\u53f6\u3044\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f8b\u3092\u6319\u3052\u307e\u3057\u3087\u3046\u3002Agilent GC-MS\u3067PCB\u5206\u6790\u3092\u3053\u3053\u306b\u793a\u3057\u305f\u6761\u4ef6\u3067\u884c\u3063\u305f\u3068\u3057\u307e\u3059\u3002\u5206\u96e2\u306b\u95a2\u3057\u3066\u306f\u6e80\u8db3\u304b\u3068\u601d\u3044\u307e\u3059\u304c\u3001\u5206\u6790\u6642\u9593\u3092\u77ed\u7e2e\u3057\u3066\u3001\u4e00\u56de\u306e\u5206\u6790\u3067\u306e\u30b5\u30f3\u30d7\u30eb\u51e6\u7406\u6570\u3092\u5897\u3084\u3057\u305f\u3044\u3068\u601d\u3044\u307e\u305b\u3093\u304b\uff1f\u305d\u308c\u306a\u3089\u3001\u540c\u3058\u76f8\u6bd4\u3067\u540c\u3058\u7406\u8ad6\u6bb5\u6570\u306b\u30b9\u30b1\u30fc\u30eb\u30c0\u30a6\u30f3\u3055\u308c\u305f\u30ab\u30e9\u30e0\u3092\u9078\u5b9a\u3059\u308b\u3053\u3068\u304b\u3089\u59cb\u3081\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u4f8b\u3067\u306f\u3001\u30ab\u30e9\u30e0\u957730 m\u3001\u5185\u5f840.25 mm\u3001\u819c\u539a0.25 \u00b5m\u306e\u30ab\u30e9\u30e0\u304b\u3089\u5e02\u8ca9\u306e\u30ab\u30e9\u30e0\u957720 m\u3001\u5185\u5f840.15 mm\u3001\u819c\u539a0.15 \u00b5m\u306e\u30ab\u30e9\u30e0\u306b\u5909\u66f4\u3057\u3066\u307f\u307e\u3059\u3002\u6bb5\u6570\u306e\u7dcf\u6570\u306f\u4e21\u8005\u3067\u307b\u307c\u540c\u3058\u3067\u3059\u3002\u5206\u6790\u6642\u9593\u3092\u77ed\u7e2e\u3057\u3064\u3064\u3001\u540c\u3058\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u96e2\u3092\u5f97\u308b\u3053\u3068\u304c\u53ef\u80fd\u306a\u3001\u5909\u66f4\u5f8c\u306e\u30ab\u30e9\u30e0\u3067\u306e\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u5909\u63db\u306f\u6b21\u306e\u624b\u9806\u3067\u5b9f\u884c\u3057\u307e\u3059\u3002\u4f8b\u3092\u898b\u306a\u304c\u3089<em>EZ<\/em>GC Method Translator\u3092\u81ea\u5206\u3067\u4f7f\u7528\u3057\u3066\u307f\u305f\u3044\u5834\u5408\u306f\u3001www.restek.com\/ezgc-mtfc\u306b\u30a2\u30af\u30bb\u30b9\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305a\u3001\u30e1\u30bd\u30c3\u30c9\u306b\u9069\u3057\u305f\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3092\u9078\u629e\u3057\u3001\u73fe\u884c\u306e\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3092\u5165\u529b\u3057\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001\u73fe\u884c\u30e1\u30bd\u30c3\u30c9\u306e\u30ab\u30e9\u30e0\u6d41\u91cf\u3092\u5165\u529b\u3057\u307e\u3059\u3002\u5e73\u5747\u7dda\u901f\u5ea6\u3001\u30db\u30fc\u30eb\u30c9\u30bf\u30a4\u30e0\u3001\u304a\u3088\u3073\u6ce8\u5165\u53e3\u5727\u529b\u306f\u3001\u6307\u5b9a\u3057\u305f\u30ab\u30e9\u30e0\u6d41\u91cf\u306b\u57fa\u3065\u3044\u3066\u81ea\u52d5\u8a08\u7b97\u3055\u308c\u308b\u3053\u3068\u306b\u3054\u6ce8\u610f\u304f\u3060\u3055\u3044\u3002\u3053\u3053\u3067\u306fMS\u30e1\u30bd\u30c3\u30c9\u3092\u5b9f\u884c\u3057\u3066\u3044\u308b\u306e\u3067\u3001\u51fa\u53e3\u5727\u529b\u5024\u304c0 psi\u306b\u8a2d\u5b9a\u3055\u308c\u3001\u300c\u771f\u7a7a\uff08Vacuum\uff09\u300d\u304c\u9078\u629e\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u3092\u5fc5\u305a\u78ba\u8a8d\u3057\u3066\u4e0b\u3055\u3044\u3002\u3053\u308c\u3089\u306f\u30c7\u30d5\u30a9\u30eb\u30c8\u306e\u9078\u629e\u3067\u3059\u304c\u3001\u7570\u306a\u308b\u3082\u306e\u304c\u9078\u629e\u3055\u308c\u3066\u3044\u308b\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070FID\u3092\u4f7f\u7528\u3057\u3066\u3044\u3066\u3001\u51fa\u53e3\u5727\u529b\u304c\u5927\u6c17\u5727\u3067\u3042\u308a\u3001\u8cea\u91cf\u5206\u6790\u8a08\u3067\u751f\u6210\u3055\u308c\u305f\u771f\u7a7a\u3067\u306f\u306a\u3044\u5834\u5408\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b21\u306b\u3001\u73fe\u884c\u306e\u30aa\u30fc\u30d6\u30f3\u30d7\u30ed\u30b0\u30e9\u30e0\u3092\u5165\u529b\u3057\u307e\u3059\u3002\u5236\u5fa1\u65b9\u6cd5\u304c\u6b63\u3057\u3044\u3053\u3068\u3001\u3068\u30c7\u30d5\u30a9\u30eb\u30c8\u3067 \u300c\u5909\u63db\uff08Translate\uff09\u300d\u304c\u9078\u629e\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u3001\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002\u300c\u5909\u63db\uff08Translate\uff09\u300d\u3092\u9078\u629e\u3059\u308c\u3070\u3001<em>EZ<\/em>GC Method Translator\u306f\u30d0\u30e9\u30f3\u30b9\u306e\u826f\u3044\u901f\u5ea6\u3068\u52b9\u7387\u3092\u8a08\u7b97\u3057\u307e\u3059\u3002\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3092\u5165\u529b\u3059\u308b\u3068\u3001<em>EZ<\/em>GC Method Translator\u304c\u6b8b\u308a\u306e\u4f5c\u696d\u3092\u884c\u3044\u3001\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u6d41\u91cf\u3068\u305d\u308c\u306b\u6e96\u3058\u3066\u8a08\u7b97\u3055\u308c\u305f\u6d41\u91cf\u95a2\u9023\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u3001\u65b0\u3057\u3044\u6607\u6e29\u30ec\u30fc\u30c8\uff08Ramps\uff09\u3092\u8868\u793a\u3057\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u3057\u3066\u3001\u5206\u6790\u6642\u9593\u3092\u77ed\u7e2e\u3057\u3064\u3064\u4eca\u307e\u3067\u3068\u540c\u3058\u5206\u96e2\u3092\u3001\u30b9\u30b1\u30fc\u30eb\u30c0\u30a6\u30f3\u3057\u305f\u30ab\u30e9\u30e0\u3067\u5f97\u308b\u3053\u3068\u304c\u51fa\u6765\u307e\u3059\u3002\u3053\u306e\u4f8b\u3067\u306f\u3001\u5206\u6790\u6642\u9593\u304c8\u5206\u8fd1\u304f\u77ed\u7e2e\u3055\u308c\u307e\u3057\u305f\u304c\u3001\u3053\u308c\u306f\u5206\u6790\u6642\u9593\u306e\u7d0430%\u306b\u8a72\u5f53\u3057\u307e\u3059\u3002\u7c21\u5358\u306b\u8a00\u3048\u3070\u3001\u4e00\u9023\u306e\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u306b\u306f\u901a\u5e388\u6642\u9593\u304b\u304b\u308a\u307e\u3059\u304c\u3001\u305d\u308c\u304c5.5\u6642\u9593\u5f37\u306b\u77ed\u7e2e\u3055\u308c\u308b\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u5909\u63db\u5f8c\u30e1\u30bd\u30c3\u30c9\u304c\u8981\u6c42\u3059\u308b\u6607\u6e29\u901f\u5ea6\u306f\u3001\u6a19\u6e96\u7684\u306aGC\u30aa\u30fc\u30d6\u30f3\u3067\u306f\u5b9f\u73fe\u3067\u304d\u306a\u3044\u53ef\u80fd\u6027\u304c\u3042\u308b\u3053\u3068\u306b\u3054\u6ce8\u610f\u304f\u3060\u3055\u3044\u3002\u3053\u306e\u3088\u3046\u306a\u5834\u5408\u306f\u3001Agilen 6890\u304a\u3088\u30737890\u88c5\u7f6e\u7528\u306eGC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u30ad\u30c3\u30c8\u306e\u4f7f\u7528\u304c\u89e3\u6c7a\u7b56\u3068\u306a\u308b\u3067\u3057\u3087\u3046\u3002GC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u30ad\u30c3\u30c8\u306e\u4f7f\u7528\u3067\u3001\u30aa\u30fc\u30d6\u30f3\u4f53\u7a4d\u306f\u5c0f\u3055\u304f\u306a\u308a\u3001\u52a0\u71b1\/\u51b7\u5374\u6642\u9593\u304c\u77ed\u304f\u306a\u308a\u307e\u3059\u3002\u7d50\u679c\u3068\u3057\u3066\u3001\u6607\u6e29\u901f\u5ea6\u3092\u4e0a\u3052\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0a\u8a18\u306e\u3088\u3046\u306a\u5909\u66f4\u3092\u884c\u3046\u5834\u5408\u3001\u3053\u306e\u70b9\u3060\u3051\u306f\u899a\u3048\u3066\u3044\u3066\u304f\u3060\u3055\u3044\u3002\u3088\u308a\u5185\u5f84\u304c\u5c0f\u3055\u304f\u3001\u819c\u539a\u304c\u8584\u3044\u30ab\u30e9\u30e0\u306b\u5207\u308a\u66ff\u3048\u308b\u306a\u3089\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u30e2\u30fc\u30c9\u3068\u306e\u7d44\u5408\u305b\u304c\u6700\u9069\u3067\u3042\u308b\u3001\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306b\u306f2\u3064\u306e\u5229\u70b9\u304c\u3042\u308a\u307e\u3059\u3002\u307e\u305a\u3001\u819c\u539a\u304c\u8584\u3044\u3053\u3068\u3067\u904e\u8ca0\u8377\u306e\u30d5\u30ed\u30f3\u30c8\u30d4\u30fc\u30af\u304c\u767a\u751f\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u304c\u305d\u306e\u3088\u3046\u306a\u8ca0\u8377\u5bb9\u91cf\u306b\u95a2\u3059\u308b\u3059\u3079\u3066\u306e\u61f8\u5ff5\u3092\u89e3\u6c7a\u3059\u308b\u3001\u3068\u3044\u3046\u70b9\u3067\u3059\u3002\u6b21\u306b\u3001\u30ab\u30e9\u30e0\u3078\u306e\u30b5\u30f3\u30d7\u30eb\u79fb\u9001\u304c\u9ad8\u901f\u5316\u3055\u308c\u308b\u306e\u3067\u3001\u5206\u5b50\u306e\u30d0\u30f3\u30c9\u5e45\u304c\u72ed\u304f\u306a\u308a\u3001\u7d50\u679c\u3068\u3057\u3066\u30d4\u30fc\u30af\u5e45\u3082\u72ed\u304f\u306a\u308b\u70b9\u3067\u3059\u3002\u3053\u308c\u306f\u6700\u5927\u306e\u5229\u70b9\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u3088\u3046\u306b\u3001\u540c\u3058\u76f8\u6bd4\u3067\u3042\u308c\u3070\u3001\u30b9\u30b1\u30fc\u30eb\u30c0\u30a6\u30f3\u3057\u305f\u30ab\u30e9\u30e0\u306b\u5207\u308a\u66ff\u3048\u3066\u3082\u3001\u5206\u6790\u6642\u9593\u3092\u5927\u5e45\u306b\u77ed\u7e2e\u3057\u306a\u304c\u3089\u540c\u7b49\u306e\u5206\u6790\u7d50\u679c\u3092\u5f97\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002Restek\u306e<em>EZ<\/em>GC\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3092\u4f7f\u7528\u3059\u308c\u3070\u3001\u3069\u3093\u306aGC\u30b7\u30b9\u30c6\u30e0\u3067\u3082\u3053\u306e\u52b9\u7387\u5316\u306f\u5b9f\u73fe\u3067\u304d\u307e\u3059\u3002\u305d\u306e\u4e0a\u3001\u5909\u63db\u5f8c\u30e1\u30bd\u30c3\u30c9\u3092\u6700\u9069\u5316\u3059\u308b\u3053\u3068\u3055\u3048\u3082\u53ef\u80fd\u3067\u3059\u3002\u5909\u63db\u5f8c\u30e1\u30bd\u30c3\u30c9\u3092\u5b9f\u884c\u3059\u308b\u5834\u5408\u306f\u3001\u65b0\u3057\u3044\u30aa\u30fc\u30d6\u30f3\u30d7\u30ed\u30b0\u30e9\u30e0\u304c\u304a\u4f7f\u3044\u306e\u30aa\u30fc\u30d6\u30f3\u306e\u80fd\u529b\u3092\u8d85\u3048\u306a\u3044\u3053\u3068\u3092\u5fc5\u305a\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002Agilent 6890\u304a\u3088\u30737890GC-MS \u30e6\u30fc\u30b6\u30fc\u306f\u3001GC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf \u30ad\u30c3\u30c8\u3092\u4f7f\u7528\u3057\u3066\u3001\u3088\u308a\u7a4d\u6975\u7684\u306a\u30aa\u30fc\u30d6\u30f3\u30d7\u30ed\u30b0\u30e9\u30e0\u3092\u5b9f\u73fe\u3067\u304d\u307e\u3059\u3002GC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u30ad\u30c3\u30c8\u306e\u4f7f\u7528\u306b\u3088\u308a\u30aa\u30fc\u30d6\u30f3\u4f53\u7a4d\u304c\u5c0f\u3055\u304f\u306a\u3063\u3066\u3044\u308b\u306e\u3067\u3001\u30aa\u30fc\u30d6\u30f3\u306e\u52a0\u71b1\/\u51b7\u5374\u6642\u9593\u304c\u77ed\u304f\u306a\u308a\u3001\u6700\u7d42\u7684\u306b\u306f\u5206\u6790\u304c\u9ad8\u901f\u5316\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Restek\u306eEZGC Method Translator\u3068GC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u30ad\u30c3\u30c8\u3092\u6d3b\u7528\u3057\u3001\u65e2\u5b58\u306eGC-MS\u30e1\u30bd\u30c3\u30c9\u3092\u305d\u306e\u307e\u307e\u306b\u5206\u6790\u6642\u9593\u3092\u6700\u592730\uff05\u77ed\u7e2e\u3059\u308b\u65b9\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":41117,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[774],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2564,2552],"resource-technique":[2340,2345],"ppma_author":[414],"class_list":["post-42465","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-ja","product-library-gc-columns-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja","resource-technique-mass-spectrometry-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":774,"label":"\u52d5\u753b"}],"product-library":[{"value":2564,"label":"GC \u30ab\u30e9\u30e0"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2345,"label":"\u8cea\u91cf\u5206\u6790 (MS)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3608-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":774,"name":"\u52d5\u753b","slug":"videos-ja","term_group":0,"term_taxonomy_id":774,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":774,"category_count":138,"category_description":"","cat_name":"\u52d5\u753b","category_nicename":"videos-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42465","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=42465"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42465\/revisions"}],"predecessor-version":[{"id":79023,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42465\/revisions\/79023"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/41117"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=42465"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=42465"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=42465"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=42465"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=42465"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=42465"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=42465"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=42465"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=42465"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}