{"id":42467,"date":"2018-02-22T05:00:00","date_gmt":"2018-02-22T05:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/how-to-install-resteks-gc-accelerator-kit-japan\/"},"modified":"2025-12-31T14:54:21","modified_gmt":"2025-12-31T14:54:21","slug":"how-to-install-resteks-gc-accelerator-kit-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3609-ja\/how-to-install-resteks-gc-accelerator-kit-japan","title":{"rendered":"GC\u30e1\u30bd\u30c3\u30c9\u6700\u9069\u5316\u3092\u5b9f\u73fe\u3059\u308bGC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u30ad\u30c3\u30c8\u306e\u53d6\u4ed8\u65b9\u6cd5"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"How to Install Restek&#039;s GC Accelerator Kit\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/qHT2bbcFEvo?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"512\" height=\"373\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1.png\" alt=\"\" class=\"wp-image-29853\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1.png 512w, https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1-300x219.png 300w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"447\" height=\"528\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12.png\" alt=\"\" class=\"wp-image-29859\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12.png 447w, https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12-254x300.png 254w\" sizes=\"auto, (max-width: 447px) 100vw, 447px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">YouTube\u753b\u9762\u53f3\u4e0b\u306b\u3042\u308b\u8a2d\u5b9a\u30dc\u30bf\u30f3\u2699\u304b\u3089Subtitles\/CC\u3092\u9078\u3073\u3001Japanese\u306b\u30c1\u30a7\u30c3\u30af\u3092\u5165\u308c\u308b\u3068\u65e5\u672c\u8a9e\u5b57\u5e55\u3042\u308a\u3067\u52d5\u753b\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u6982\u8981<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">GC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u30ad\u30c3\u30c8\u306e\u53d6\u4ed8\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002Restek\u306eGC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u30ad\u30c3\u30c8\u306f\u3001\u8cea\u91cf\u5206\u6790\u8a08\uff08MS\uff09\u3092\u642d\u8f09\u3057\u305fAgilent 6890\u304a\u3088\u30737890 GC\u306e\u30aa\u30fc\u30d6\u30f3\u4f53\u7a4d\u3092\u5c0f\u3055\u304f\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u6607\u6e29\u901f\u5ea6\u3092\u4e0a\u3052\u308b\u3053\u3068\u304c\u53ef\u80fd\u306b\u306a\u308b\u3068\u540c\u6642\u306b\u30af\u30fc\u30eb\u30c0\u30a6\u30f3\u6642\u9593\u3082\u77ed\u7e2e\u3055\u308c\u307e\u3059\u3002\u3064\u307e\u308a\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u306e\u9ad8\u901f\u5316\u304c\u5b9f\u73fe\u3057\u307e\u3059\u3002<em>EZ<\/em>GC Method Translator\u306f\u3001\u65e2\u5b58\u306e\u30e1\u30bd\u30c3\u30c9\u3092\u30b9\u30b1\u30fc\u30eb\u30c0\u30a6\u30f3\u3057\u305f\u30ab\u30e9\u30e0\u7528\u306b\u5909\u63db\u3059\u308b\u3068\u304d\u306b\u4f7f\u7528\u3055\u308c\u3001\u30e1\u30bd\u30c3\u30c9\u306e\u6700\u9069\u5316\u3092\u884c\u3044\u307e\u3059\u3002 www.restek.com\/ezgc\u306b\u30a2\u30af\u30bb\u30b9\u3057\u3066\u307f\u3066\u4e0b\u3055\u3044\u3002\u3053\u306e\u7121\u6599\u30aa\u30f3\u30e9\u30a4\u30f3\u30c4\u30fc\u30eb\u3092\u4f7f\u3048\u3070\u3001\u540c\u7b49\u306e\u5206\u96e2\u3092\u77ed\u3044\u5206\u6790\u6642\u9593\u3067\u884c\u3046\u305f\u3081\u306e\u3001\u6607\u6e29\u901f\u5ea6\u306a\u3069\u306e\u5206\u6790\u6761\u4ef6\u304c\u5206\u304b\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u305d\u306e\u4ed6\u306e\u30ea\u30bd\u30fc\u30b9<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/ez.restek.com\/ezgc-mtfc\/en\" target=\"_blank\" rel=\"noopener\"><em>EZ<\/em>GC Method Translator<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Restek\u63a8\u5968\u30c4\u30fc\u30eb\u3068\u90e8\u54c1<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/p\/23849\" target=\"_blank\" rel=\"noopener\">GC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u30ad\u30c3\u30c8<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Restek\u306b\u306f\u3053\u3061\u3089\u304b\u3089\u3082\u30a2\u30af\u30bb\u30b9\u3067\u304d\u307e\u3059<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">YouTube:&nbsp;<a href=\"https:\/\/www.youtube.com\/user\/RestekCorp\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.youtube.com\/user\/RestekCorp<\/a>&nbsp;<br>LinkedIn:&nbsp;<a href=\"https:\/\/www.linkedin.com\/company\/restek-corporation\/\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.linkedin.com\/company\/restek-corporation\/<\/a><br>Facebook:&nbsp;<a href=\"https:\/\/www.facebook.com\/RestekCorporation\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.facebook.com\/RestekCorporation<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306eGC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u30ad\u30c3\u30c8\u306f\u3001\u8cea\u91cf\u5206\u6790\u8a08\uff08MS\uff09\u3092\u642d\u8f09\u3057\u305fAgilent 6890\u304a\u3088\u30737890 GC\u30aa\u30fc\u30d6\u30f3\u306e\u30aa\u30fc\u30d6\u30f3\u4f53\u7a4d\u3092\u5c0f\u3055\u304f\u3059\u308b\u3068\u304d\u306b\u4f7f\u3044\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u6607\u6e29\u901f\u5ea6\u304c\u4e0a\u304c\u308a\u3001\u30af\u30fc\u30eb\u30c0\u30a6\u30f3\u6642\u9593\u3082\u77ed\u7e2e\u3055\u308c\u307e\u3059\u3002\u3064\u307e\u308a\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u304c\u9ad8\u901f\u5316\u3055\u308c\u307e\u3059\u3002\u65e2\u5b58\u306e\u30e1\u30bd\u30c3\u30c9\u3092\u30b9\u30b1\u30fc\u30eb\u30c0\u30a6\u30f3\u3057\u305f\u30ab\u30e9\u30e0\u7528\u306b\u5909\u63db\u3057\u3001\u6700\u9069\u5316\u3059\u308b\u969b\u306b\u306f\u3001<em>EZ<\/em>GC Method Translator\u3092\u4f7f\u3044\u307e\u3059\u3002 www.restek.com\/ezgc\u306b\u30a2\u30af\u30bb\u30b9\u3057\u3066\u307f\u3066\u4e0b\u3055\u3044\u3002\u3053\u306e\u7121\u6599\u30aa\u30f3\u30e9\u30a4\u30f3\u30c4\u30fc\u30eb\u3092\u4f7f\u3048\u3070\u3001\u540c\u7b49\u306e\u5206\u96e2\u3092\u77ed\u3044\u5206\u6790\u6642\u9593\u3067\u884c\u3046\u305f\u3081\u306e\u3001\u6607\u6e29\u901f\u5ea6\u306a\u3069\u306e\u5206\u6790\u6761\u4ef6\u304c\u5206\u304b\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305a\u3001Agilent 6890\u304a\u3088\u30737890 GC\u30aa\u30fc\u30d6\u30f3\u3067\u306e\u6a19\u6e96\u7684\u306a\u6607\u6e29\u901f\u5ea6\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b21\u306b\u3001GC \u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u30ad\u30c3\u30c8\u3092\u4f7f\u3063\u305f\u3001\u540c\u3058\u30aa\u30fc\u30d6\u30f3\u3067\u306e\u6607\u6e29\u901f\u5ea6\u3092\u4e26\u3079\u305f\u3082\u306e\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306eGC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u30ad\u30c3\u30c8\u306f\u3001\u8cea\u91cf\u5206\u6790\u8a08\u3092\u642d\u8f09\u3057\u305fAgilent 6890\u304a\u3088\u30737890 GC\u7528\u306b\u7279\u5225\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u306f\u3001GC\u306e\u524d\u9762\u307e\u305f\u306f\u80cc\u9762\u306b\u53d6\u308a\u4ed8\u3051\u3089\u308c\u305f\u4ed6\u306e\u691c\u51fa\u5668\u3092\u5099\u3048\u305fGC\u306b\u9069\u5408\u3057\u307e\u3059\u304c\u3001\u524d\u9762\u307e\u305f\u306f\u80cc\u9762\u306b\u53d6\u308a\u4ed8\u3051\u3089\u308c\u305f\u5165\u53e3\u3068\u8cea\u91cf\u5206\u6790\u8a08\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u306b\u306e\u307f\u63a8\u5968\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7279\u5b9a\u306e\u30e2\u30c7\u30eb\u306b\u306f\u3001\u7279\u5b9a\u306e\u30b9\u30a4\u30c3\u30c1\u30f3\u30b0\u30d0\u30eb\u30d6\u304a\u3088\u3073\/\u307e\u305f\u306fGCxGC\u30e2\u30b8\u30e5\u30ec\u30fc\u30bf\u30fc\u304c\u3042\u308b\u305f\u3081\u3001GC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u306e\u53d6\u308a\u4ed8\u3051\u4f4d\u7f6e\u306b\u306f\u5236\u9650\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6df1\u3055\u304c40 mm\u3092\u8d85\u3048\u308b\u30b1\u30fc\u30b8\u4e0a\u306e\u30ab\u30e9\u30e0\u306b\u3001GC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u306f\u63a8\u5968\u3057\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u3067\u306f\u3001GC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u30ad\u30c3\u30c8\u306e\u30b3\u30f3\u30dd\u30fc\u30cd\u30f3\u30c8\u3092\u53d6\u308a\u6271\u3046\u969b\u306b\u4fdd\u8b77\u624b\u888b\u3092\u7740\u7528\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">GC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u3092\u8a2d\u7f6e\u3059\u308b\u306b\u306f\u3001\u30aa\u30fc\u30d6\u30f3\u3001\u6ce8\u5165\u53e3\u3001\u691c\u51fa\u5668\u3001\u304a\u3088\u3073 MS \u30c8\u30e9\u30f3\u30b9\u30d5\u30a1\u30e9\u30a4\u30f3\u306e\u52a0\u71b1\u3055\u308c\u305f\u30be\u30fc\u30f3\u3092\u30aa\u30d5\u306b\u3057\u3001\u51b7\u5374\u3055\u308c\u308b\u307e\u3067\u5f85\u3061\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ab\u30e9\u30e0\u3068\u30ab\u30e9\u30e0\u30cf\u30f3\u30ac\u30fc\u304c\u30aa\u30fc\u30d6\u30f3\u306e\u5965\u306e\u4f4d\u7f6e\u306b\u3042\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u305d\u306e\u5f8c\u3001\u691c\u51fa\u5668\u304c\u524d\u9762\u306b\u306a\u3044\u5834\u5408\u306f\u3001\u30d6\u30ed\u30c3\u30af\u30a4\u30f3\u30b5\u30fc\u30c82\u500b\u3092\u3053\u306e\u3088\u3046\u306b\u30ab\u30e9\u30e0\u306e\u524d\u306b\u53d6\u308a\u4ed8\u3051\u307e\u3059\u3002\u691c\u51fa\u5668\u304c\u524d\u9762\u306b\u3042\u308b\u5834\u5408\u306f\u3001\u30d6\u30ed\u30c3\u30af\u30a4\u30f3\u30b5\u30fc\u30c82\u500b\u3092\u3053\u306e\u3088\u3046\u306b\u53d6\u308a\u4ed8\u3051\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d6\u30ed\u30c3\u30af\u30a4\u30f3\u30b5\u30fc\u30c8\u304c\u5206\u6790\u30ab\u30e9\u30e0\u307e\u305f\u306fMSD\u30bd\u30fc\u30b9\u30ca\u30c3\u30c8\u306b\u89e6\u308c\u306a\u3044\u3088\u3046\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6700\u5f8c\u306b\u3001\u30d7\u30ec\u30fc\u30c8\u30a4\u30f3\u30b5\u30fc\u30c8\u3092\u30aa\u30fc\u30d6\u30f3\u524d\u9762\u306b\u53d6\u308a\u4ed8\u3051\u3001\u524d\u9762\u304c\u30aa\u30fc\u30d6\u30f3\u7aef\u3068\u9762\u4e00\u306b\u306a\u308b\u3088\u3046\u306b\u3057\u307e\u3059\u3002GC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u3092\u53d6\u308a\u5916\u3059\u306b\u306f\u3001\u30aa\u30fc\u30d6\u30f3\u3001\u6ce8\u5165\u53e3\u3001\u691c\u51fa\u5668\u3001\u304a\u3088\u3073MS\u30c8\u30e9\u30f3\u30b9\u30d5\u30a1\u30e9\u30a4\u30f3\u306e\u52a0\u71b1\u3055\u308c\u305f\u30be\u30fc\u30f3\u3092\u30aa\u30d5\u306b\u3057\u3001\u51b7\u5374\u3055\u308c\u308b\u307e\u3067\u5f85\u3061\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">GC\u30aa\u30fc\u30d6\u30f3\u304c\u5341\u5206\u306b\u51b7\u5374\u3055\u308c\u3066\u3082\u3001\u30d7\u30ec\u30fc\u30c8\u30a4\u30f3\u30b5\u30fc\u30c8\u306e\u91d1\u5c5e\u88fd\u30d5\u30a1\u30b9\u30ca\u30fc\u304a\u3088\u3073\u30e9\u30d9\u30eb\u30bf\u30b0\u306f\u307e\u3060\u71b1\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u706b\u50b7\u3057\u306a\u3044\u3088\u3046\u306b\u3001\u30d7\u30ec\u30fc\u30c8\u30a4\u30f3\u30b5\u30fc\u30c8\u3092\u53d6\u308a\u5916\u3059\u969b\u306f\u30b9\u30c8\u30e9\u30c3\u30d7\u3092\u4f7f\u7528\u3059\u308b\u304b\u3001\u8010\u71b1\u624b\u888b\u3092\u7740\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d7\u30ec\u30fc\u30c8\u30a4\u30f3\u30b5\u30fc\u30c8\u3092\u53d6\u308a\u5916\u3059\u306b\u306f\u3001\u30b9\u30c8\u30e9\u30c3\u30d7\u3092\u63e1\u308a\u3001\u307e\u305a\u4e0b\u7aef\u3092\u5f15\u304d\u51fa\u3057\u3066\u53d6\u308a\u5916\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d6\u30ed\u30c3\u30af\u30a4\u30f3\u30b5\u30fc\u30c8\u306f\u614e\u91cd\u306b\u53d6\u308a\u5916\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30ab\u30e9\u30e0\u3084MSD\u30bd\u30fc\u30b9\u30ca\u30c3\u30c8\u306b\u89e6\u308c\u306a\u3044\u3088\u3046\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Restek\u306eGC\u30a2\u30af\u30bb\u30e9\u30ec\u30fc\u30bf\u30ad\u30c3\u30c8\u3067Agilent GC\u306e\u5206\u6790\u6642\u9593\u3092\u5927\u5e45\u306b\u77ed\u7e2e\u3002\u6607\u6e29\u30fb\u51b7\u5374\u6642\u9593\u3092\u6539\u5584\u3057\u3001\u30e1\u30bd\u30c3\u30c9\u306e\u9ad8\u901f\u5316\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002\u7121\u6599\u306eEZGC\u30c4\u30fc\u30eb\u3067\u30e1\u30bd\u30c3\u30c9\u6700\u9069\u5316\u3082\u7c21\u5358\u306b\u5b9f\u73fe\u53ef\u80fd\u3067\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":41123,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[774],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2552],"resource-technique":[2340],"ppma_author":[2814],"class_list":["post-42467","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":774,"label":"\u52d5\u753b"}],"product-library":[{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3609-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":774,"name":"\u52d5\u753b","slug":"videos-ja","term_group":0,"term_taxonomy_id":774,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":774,"category_count":138,"category_description":"","cat_name":"\u52d5\u753b","category_nicename":"videos-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42467","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=42467"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42467\/revisions"}],"predecessor-version":[{"id":79022,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42467\/revisions\/79022"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/41123"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=42467"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=42467"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=42467"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=42467"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=42467"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=42467"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=42467"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=42467"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=42467"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}