{"id":42471,"date":"2020-03-24T04:00:00","date_gmt":"2020-03-24T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-how-to-store-reference-standards\/"},"modified":"2026-10-02T21:05:50","modified_gmt":"2026-10-02T21:05:50","slug":"japanese-how-to-store-reference-standards","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3610-ja\/japanese-how-to-store-reference-standards","title":{"rendered":"\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\uff08\u6a19\u6e96\u6eb6\u6db2\uff09\u306e\u4fdd\u7ba1\u65b9\u6cd5"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"How to Store Reference Standards\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/RW1f6WGItis?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">\u65e5\u672c\u8a9e\u5b57\u5e55\u3092\u8868\u793a\u3067\u304d\u307e\u3059<\/p>\n\n\n\n<style data-wp-block-html=\"css\">\n<style>\n.rtk-article { line-height: 1.8; font-size: 16px; }\n\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n\n.rtk-article h2 {\n  margin-top: 4em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n\n.rtk-article h3 {\n  margin-top: 2.4em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n\n.rtk-article p {\n  font-size: 18px;\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n\n.rtk-article a {\n  font-size: inherit !important;\n}\n\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n\n.rtk-article .rtk-lead {\n  font-size: 18px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n\n.rtk-article blockquote.rtk-voc {\n  position: relative;\n  border-left: 4px solid #00265d;\n  background: #f7f8f9;\n  padding: 18px 22px 18px 30px;\n  margin: 2em 0;\n  font-style: italic;\n  color: #333;\n}\n.rtk-article blockquote.rtk-voc p { margin-bottom: 0.4em; }\n.rtk-article blockquote.rtk-voc cite {\n  display: block;\n  font-style: normal;\n  font-size: 13px;\n  color: #4a4a4a;\n}\n\n.rtk-article .rtk-coa-list {\n  list-style: none;\n  padding: 0;\n}\n.rtk-article .rtk-coa-list li {\n  background: #fafbfc;\n  border: 1px solid #e1e8ec;\n  border-radius: 6px;\n  padding: 14px 18px;\n  margin-bottom: 12px;\n}\n\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 2.8em; }\n  .rtk-article h3 { margin-top: 1.8em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout,\n  .rtk-article blockquote.rtk-voc {\n    padding: 14px 16px;\n  }\n}\n<\/style>\n\n<div class=\"rtk-article\">\n\n<div class=\"rtk-intro\">\n<p class=\"rtk-lead\">\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u6fc3\u5ea6\u304c\u5909\u308f\u3063\u3066\u3057\u307e\u3046\u3068\u3001\u5206\u6790\u306f\u6df7\u4e71\u3092\u304d\u305f\u3057\u3001\u30e9\u30dc\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u304c\u59a8\u3052\u3089\u308c\u3001\u6642\u9593\u3068\u8cbb\u7528\u304c\u7121\u99c4\u306b\u4f7f\u308f\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\uff08\u6a19\u6e96\u6eb6\u6db2\uff09\u3092\u9069\u5207\u306b\u4fdd\u7ba1\u3059\u308b\u3068\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u6700\u9069\u306a\u5b89\u5b9a\u6027\u304c\u78ba\u4fdd\u3055\u308c\u3001\u5206\u6790\u696d\u52d9\u306b\u96c6\u4e2d\u3067\u304d\u307e\u3059\u3002<\/p>\n<\/div>\n\n<h1>\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306e\u4fdd\u7ba1\u65b9\u6cd5<\/h1>\n\n<p>\u3053\u306eRestek Tip\u3067\u306f\u3001\u69d8\u3005\u306a\u6e29\u5ea6\u7bc4\u56f2\u3067\u306e\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306e\u5b89\u5168\u306a\u4fdd\u7ba1\u65b9\u6cd5\u3068\u3001\u7279\u5b9a\u306e\u6a19\u6e96\u6db2\u306b\u95a2\u3059\u308b\u8a73\u7d30\u306a\u4fdd\u7ba1\u60c5\u5831\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n<details style=\"cursor:pointer; border:1px solid #d8e3e6; border-radius:6px; margin-bottom:2em; overflow:hidden;\">\n<summary style=\"cursor:pointer; padding:14px 18px; background:#f5f9fc; list-style:none; font-weight:700;\">\u52d5\u753b\u306e\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u3092\u8868\u793a<\/summary>\n<div style=\"padding:4px 18px 18px;\">\n<p>\u6a19\u6e96\u6eb6\u6db2\u3092\u9069\u5207\u306b\u4fdd\u7ba1\u3059\u308b\u3053\u3068\u306f\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u6700\u9069\u306a\u5b89\u5b9a\u6027\u3092\u78ba\u4fdd\u3059\u308b\u3046\u3048\u3067\u6b20\u304b\u305b\u307e\u305b\u3093\u3002\u4eca\u56de\u306eRestek Tip\u3067\u306f\u3001\u6a19\u6e96\u6eb6\u6db2\u306e\u4fdd\u7ba1\u65b9\u6cd5\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u9069\u5207\u306a\u4fdd\u7ba1\u304c\u91cd\u8981\u3067\u3042\u308b\u7406\u7531\u3068\u3001\u9069\u5207\u306a\u4fdd\u7ba1\u65b9\u6cd5\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n<p>\u307e\u305a\u57fa\u672c\u4e8b\u9805\u304b\u3089\u78ba\u8a8d\u3057\u307e\u3057\u3087\u3046\u3002\u6a19\u6e96\u6eb6\u6db2\u306e\u5206\u6790\u8a3c\u660e\u66f8\u306b\u8a18\u8f09\u3055\u308c\u305f\u6307\u793a\u306b\u5fc5\u305a\u5f93\u3063\u3066\u304f\u3060\u3055\u3044\u3002\u5fc5\u8981\u306a\u60c5\u5831\u306f\u3001\u30a2\u30f3\u30d7\u30eb\u306e\u8f38\u9001\u5bb9\u5668\u30e9\u30d9\u30eb\u3084\u30a2\u30f3\u30d7\u30eb\u672c\u4f53\u306e\u30e9\u30d9\u30eb\u306b\u3082\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u60c5\u5831\u306b\u306f\u3001\u4fdd\u7ba1\u6761\u4ef6\u3084\u8d85\u97f3\u6ce2\u51e6\u7406\u3068\u3044\u3063\u305f\u7279\u5b9a\u306e\u4e8b\u9805\u3082\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u5206\u6790\u8a3c\u660e\u66f8\u306b\u7279\u5225\u306a\u6307\u793a\u304c\u306a\u3044\u9650\u308a\u3001\u6307\u5b9a\u6e29\u5ea6\u3088\u308a\u3082\u4f4e\u3044\u6e29\u5ea6\u3067\u4fdd\u7ba1\u3057\u3066\u3082\u554f\u984c\u3042\u308a\u307e\u305b\u3093\u3002\u305f\u3060\u3057\u305d\u306e\u5834\u5408\u306f\u3001\u958b\u5c01\u524d\u306b\u30a2\u30f3\u30d7\u30eb\u3092\u5ba4\u6e29\u307e\u3067\u623b\u3057\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u304c\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9\u306b\u6b8b\u3089\u306a\u3044\u3088\u3046\u3001\u30a2\u30f3\u30d7\u30eb\u3092\u6570\u56de\u8ee2\u5012\u6df7\u548c\u3057\u3066\u304b\u3089\u958b\u5c01\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u6eb6\u3051\u6b8b\u308a\u304c\u898b\u3089\u308c\u308b\u5834\u5408\u306f\u3001\u8d85\u97f3\u6ce2\u51e6\u7406\u304c\u5fc5\u8981\u306b\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u3067\u306f\u3001\u3088\u308a\u9ad8\u3044\u6e29\u5ea6\u3067\u306e\u4fdd\u7ba1\u306f\u3069\u3046\u3067\u3057\u3087\u3046\u304b\uff1f\u4e00\u822c\u7684\u306b\u30017\u65e5\u672a\u6e80\u306e\u77ed\u671f\u9593\u3067\u3042\u308c\u3070\u3001\u6307\u5b9a\u6e29\u5ea6\u3088\u308a\u9ad8\u3044\u4fdd\u7ba1\u6e29\u5ea6\u306b\u3055\u3089\u3055\u308c\u3066\u3082\u3001\u6a19\u6e96\u6eb6\u6db2\u306e\u9577\u671f\u5b89\u5b9a\u6027\u306b\u5f71\u97ff\u3059\u308b\u3053\u3068\u306f\u901a\u5e38\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<p>\u305f\u3060\u3057\u3001\u4e00\u5ea6\u958b\u5c01\u3055\u308c\u305f\u5834\u5408\u3001\u53d6\u308a\u6271\u3044\u3084\u4fdd\u7ba1\u72b6\u6cc1\u304c\u6a19\u6e96\u6eb6\u6db2\u306e\u54c1\u8cea\u3092\u5de6\u53f3\u3057\u307e\u3059\u3002\u958b\u5c01\u5f8c\u306e\u54c1\u8cea\u306f\u4fdd\u8a3c\u3067\u304d\u307e\u305b\u3093\u306e\u3067\u3054\u6ce8\u610f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u3054\u4e0d\u660e\u306a\u70b9\u304c\u3054\u3056\u3044\u307e\u3057\u305f\u3089\u3001restek.com\u307e\u3067\u304a\u554f\u3044\u5408\u308f\u305b\u3044\u305f\u3060\u304f\u304b\u3001\u4e0b\u8a18\u306b\u30b3\u30e1\u30f3\u30c8\u3092\u304a\u5bc4\u305b\u304f\u3060\u3055\u3044\u3002\u305c\u3072\u300c\u3044\u3044\u306d\u300d\u3084\u30c1\u30e3\u30f3\u30cd\u30eb\u767b\u9332\u3082\u3088\u308d\u3057\u304f\u304a\u9858\u3044\u3044\u305f\u3057\u307e\u3059\u3002\u4eca\u56de\u306eRestek Tip\u3092\u3054\u89a7\u3044\u305f\u3060\u304d\u3001\u3042\u308a\u304c\u3068\u3046\u3054\u3056\u3044\u307e\u3057\u305f\u3002<\/p>\n<\/div>\n<\/details>\n\n<h2>\u4fdd\u7ba1\u6e29\u5ea6\u3067\u5909\u308f\u308b\u6ce8\u610f\u70b9<\/h2>\n<p>\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306e\u5b89\u5b9a\u6027\u306f\u3001\u4fdd\u7ba1\u6e29\u5ea6\u3068\u958b\u5c01\u6642\u306e\u6271\u3044\u65b9\u306b\u5927\u304d\u304f\u5de6\u53f3\u3055\u308c\u307e\u3059\u3002\u307e\u305a\u306f\u5206\u6790\u8a3c\u660e\u66f8\u306e\u6307\u793a\u3092\u78ba\u8a8d\u3057\u305f\u3046\u3048\u3067\u3001\u4ee5\u4e0b\u306e2\u3064\u306e\u30b1\u30fc\u30b9\u3092\u62bc\u3055\u3048\u3066\u304a\u304f\u3068\u5b89\u5fc3\u3067\u3059\u3002<\/p>\n\n<h3>\u6307\u5b9a\u6e29\u5ea6\u3088\u308a\u4f4e\u3044\u6e29\u5ea6\u3067\u4fdd\u7ba1\u3059\u308b\u5834\u5408<\/h3>\n<p>\u5206\u6790\u8a3c\u660e\u66f8\u306b\u7279\u5225\u306a\u6307\u793a\u304c\u306a\u3044\u9650\u308a\u3001\u6307\u5b9a\u6e29\u5ea6\u3088\u308a\u3082\u4f4e\u3044\u6e29\u5ea6\u3067\u4fdd\u7ba1\u3057\u3066\u3082\u554f\u984c\u3042\u308a\u307e\u305b\u3093\u3002\u305f\u3060\u3057\u3001\u958b\u5c01\u524d\u306b\u30a2\u30f3\u30d7\u30eb\u3092\u5ba4\u6e29\u307e\u3067\u623b\u3057\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u304c\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9\u306b\u6b8b\u3089\u306a\u3044\u3088\u3046\u3001\u30a2\u30f3\u30d7\u30eb\u3092\u6570\u56de\u8ee2\u5012\u6df7\u548c\u3057\u3066\u304b\u3089\u958b\u5c01\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u6eb6\u3051\u6b8b\u308a\u304c\u898b\u3089\u308c\u308b\u5834\u5408\u306f\u3001\u8d85\u97f3\u6ce2\u51e6\u7406\u304c\u5fc5\u8981\u306b\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n<h3>\u6307\u5b9a\u6e29\u5ea6\u3088\u308a\u9ad8\u3044\u6e29\u5ea6\u306b\u4e00\u6642\u7684\u306b\u3055\u3089\u3055\u308c\u305f\u5834\u5408<\/h3>\n<p>7\u65e5\u672a\u6e80\u306e\u77ed\u671f\u9593\u3067\u3042\u308c\u3070\u3001\u6307\u5b9a\u6e29\u5ea6\u3088\u308a\u9ad8\u3044\u4fdd\u7ba1\u6e29\u5ea6\u306b\u3055\u3089\u3055\u308c\u3066\u3082\u3001\u6a19\u6e96\u6eb6\u6db2\u306e\u9577\u671f\u5b89\u5b9a\u6027\u306b\u5f71\u97ff\u3059\u308b\u3053\u3068\u306f\u901a\u5e38\u3042\u308a\u307e\u305b\u3093\u3002\u305f\u3060\u3057\u3001\u3053\u308c\u306f\u3042\u304f\u307e\u3067\u672a\u958b\u5c01\u306e\u72b6\u614b\u304c\u524d\u63d0\u3067\u3059\u3002<\/p>\n\n<h3>\u958b\u5c01\u5f8c\u306e\u54c1\u8cea\u7ba1\u7406<\/h3>\n<p>\u4e00\u5ea6\u958b\u5c01\u3055\u308c\u305f\u6a19\u6e96\u6eb6\u6db2\u306f\u3001\u305d\u306e\u5f8c\u306e\u53d6\u308a\u6271\u3044\u3084\u4fdd\u7ba1\u72b6\u6cc1\u306b\u3088\u3063\u3066\u54c1\u8cea\u304c\u5de6\u53f3\u3055\u308c\u307e\u3059\u3002\u958b\u5c01\u5f8c\u306e\u54c1\u8cea\u306f\u4fdd\u8a3c\u3067\u304d\u306a\u3044\u305f\u3081\u3001\u958b\u5c01\u5f8c\u306f\u3067\u304d\u308b\u3060\u3051\u65e9\u304f\u4f7f\u7528\u3057\u3001\u90fd\u5ea6\u306e\u4fdd\u7ba1\u6761\u4ef6\u306b\u3082\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n<h2>\u307e\u3068\u3081\uff1a\u4fdd\u7ba1\u6642\u306b\u78ba\u8a8d\u3059\u3079\u304d\u30dd\u30a4\u30f3\u30c8<\/h2>\n<ul>\n<li><strong>\u307e\u305a\u5206\u6790\u8a3c\u660e\u66f8\u3092\u78ba\u8a8d<\/strong>\uff1a\u4fdd\u7ba1\u6761\u4ef6\u30fb\u8d85\u97f3\u6ce2\u51e6\u7406\u306e\u8981\u5426\u306f\u30a2\u30f3\u30d7\u30eb\u30e9\u30d9\u30eb\u306b\u3082\u8a18\u8f09<\/li>\n<li><strong>\u4f4e\u6e29\u4fdd\u7ba1\u6642<\/strong>\uff1a\u958b\u5c01\u524d\u306b\u5ba4\u6e29\u3078\u623b\u3057\u3001\u8ee2\u5012\u6df7\u548c\u3057\u3066\u304b\u3089\u958b\u5c01<\/li>\n<li><strong>\u9ad8\u6e29\u3078\u306e\u77ed\u671f\u66b4\u9732<\/strong>\uff1a7\u65e5\u672a\u6e80\u306a\u3089\u9577\u671f\u5b89\u5b9a\u6027\u3078\u306e\u5f71\u97ff\u306f\u901a\u5e38\u306a\u3057\uff08\u672a\u958b\u5c01\u6642\uff09<\/li>\n<li><strong>\u958b\u5c01\u5f8c<\/strong>\uff1a\u54c1\u8cea\u306f\u4fdd\u8a3c\u3055\u308c\u306a\u3044\u305f\u3081\u3001\u53d6\u308a\u6271\u3044\u30fb\u4fdd\u7ba1\u72b6\u6cc1\u306b\u6ce8\u610f<\/li>\n<\/ul>\n\n<div class=\"rtk-callout\">\n<p>\u95a2\u9023\u30ea\u30bd\u30fc\u30b9\uff1a<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl5498-ja\/handling-your-analytical-reference-standards\" target=\"_blank\" rel=\"noopener\">\u5206\u6790\u7528\u6a19\u6e96\u6eb6\u6db2\u306e\u53d6\u308a\u6271\u3044\u30ac\u30a4\u30c9\uff5c\u4fdd\u7ba1\u6e29\u5ea6\u30fb\u5149\u611f\u53d7\u6027\u30fb\u5316\u5408\u7269\u306e\u9069\u5408\u6027<br>\nRestek\u63a8\u5968\u88fd\u54c1\uff1a<a href=\"https:\/\/www.restek.com\/c\/1102?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noopener\">Restek's Reference Standards<\/a>\uff08\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9: \u6a19\u6e96\u6eb6\u6db2\uff09<\/p>\n<\/div>\n\n<h2>\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n\n<details class=\"rtk-faq\">\n<summary><h3>Q. \u6307\u5b9a\u6e29\u5ea6\u3088\u308a\u4f4e\u3044\u6e29\u5ea6\u3067\u4fdd\u7ba1\u3057\u3066\u3082\u5927\u4e08\u592b\u3067\u3059\u304b\uff1f<\/h3><\/summary>\n<p>\u5206\u6790\u8a3c\u660e\u66f8\u306b\u7279\u5225\u306a\u6307\u793a\u304c\u306a\u3044\u9650\u308a\u554f\u984c\u3042\u308a\u307e\u305b\u3093\u3002\u305f\u3060\u3057\u958b\u5c01\u524d\u306b\u306f\u30a2\u30f3\u30d7\u30eb\u3092\u5ba4\u6e29\u307e\u3067\u623b\u3057\u3001\u6570\u56de\u8ee2\u5012\u6df7\u548c\u3057\u3066\u304b\u3089\u958b\u3051\u3066\u304f\u3060\u3055\u3044\u3002\u5206\u6790\u5bfe\u8c61\u6210\u5206\u304c\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9\u306b\u6b8b\u308b\u306e\u3092\u9632\u3050\u305f\u3081\u3067\u3059\u3002<\/p>\n<\/details>\n\n<details class=\"rtk-faq\">\n<summary><h3>Q. \u6307\u5b9a\u6e29\u5ea6\u3088\u308a\u9ad8\u3044\u5834\u6240\u306b\u4e00\u6642\u7684\u306b\u7f6e\u3044\u3066\u3057\u307e\u3063\u305f\u5834\u5408\u3001\u6a19\u6e96\u6eb6\u6db2\u306f\u4f7f\u3048\u306a\u304f\u306a\u308a\u307e\u3059\u304b\uff1f<\/h3><\/summary>\n<p>7\u65e5\u672a\u6e80\u306e\u77ed\u671f\u9593\u3067\u3042\u308c\u3070\u3001\u6307\u5b9a\u6e29\u5ea6\u3088\u308a\u9ad8\u3044\u4fdd\u7ba1\u6e29\u5ea6\u306b\u3055\u3089\u3055\u308c\u3066\u3082\u3001\u672a\u958b\u5c01\u306e\u6a19\u6e96\u6eb6\u6db2\u306e\u9577\u671f\u5b89\u5b9a\u6027\u306b\u5f71\u97ff\u3059\u308b\u3053\u3068\u306f\u901a\u5e38\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<\/details>\n\n<details class=\"rtk-faq\">\n<summary><h3>Q. \u958b\u5c01\u5f8c\u306e\u6a19\u6e96\u6eb6\u6db2\u306f\u3069\u306e\u304f\u3089\u3044\u4fdd\u7ba1\u3067\u304d\u307e\u3059\u304b\uff1f<\/h3><\/summary>\n<p>\u958b\u5c01\u5f8c\u306f\u53d6\u308a\u6271\u3044\u3084\u4fdd\u7ba1\u72b6\u6cc1\u306b\u3088\u3063\u3066\u54c1\u8cea\u304c\u5de6\u53f3\u3055\u308c\u308b\u305f\u3081\u3001\u660e\u78ba\u306a\u4fdd\u8a3c\u671f\u9593\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u958b\u5c01\u5f8c\u306f\u3067\u304d\u308b\u3060\u3051\u65e9\u304f\u4f7f\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<\/details>\n\n<h2>\u8457\u8005<\/h2>\n<p><a href=\"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/\">Restek Corporation<\/a><\/p>\n\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3092\u3069\u306e\u3088\u3046\u306b\u4fdd\u7ba1\u3057\u3066\u3044\u307e\u3059\u304b\uff1fRestek Tip\u3067\u9069\u5207\u306a\u4fdd\u7ba1\u65b9\u6cd5\u3068\u306a\u305c\u9069\u5207\u306b\u4fdd\u7ba1\u3057\u306a\u304f\u3066\u306f\u306a\u3089\u306a\u3044\u304b\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n","protected":false},"author":11,"featured_media":41129,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[774,774],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2399,2579,2554],"resource-technique":[],"ppma_author":[414,2814],"class_list":["post-42471","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-ja","product-library-liquid-reference-standards","product-library-liquid-reference-standards-ja","product-library-reference-standard-products-ja"],"acf":[],"taxonomy_info":{"category":[{"value":774,"label":"\u52d5\u753b"},{"value":774,"label":"\u52d5\u753b"}],"product-library":[{"value":2399,"label":"Liquid Reference Standards"},{"value":2579,"label":"\u6a19\u6e96\u6eb6\u6db2"},{"value":2554,"label":"\u6a19\u6e96\u7269\u8cea"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3610-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":774,"name":"\u52d5\u753b","slug":"videos-ja","term_group":0,"term_taxonomy_id":774,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":774,"category_count":138,"category_description":"","cat_name":"\u52d5\u753b","category_nicename":"videos-ja","category_parent":0},{"term_id":774,"name":"\u52d5\u753b","slug":"videos-ja","term_group":0,"term_taxonomy_id":774,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":774,"category_count":138,"category_description":"","cat_name":"\u52d5\u753b","category_nicename":"videos-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."},{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42471","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=42471"}],"version-history":[{"count":18,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42471\/revisions"}],"predecessor-version":[{"id":99847,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42471\/revisions\/99847"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/41129"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=42471"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=42471"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=42471"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=42471"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=42471"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=42471"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=42471"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=42471"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=42471"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}