{"id":42505,"date":"2018-06-06T04:00:00","date_gmt":"2018-06-06T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/pro-ezgc-chromatogram-modeler-1-entering-compound-lists-japan\/"},"modified":"2026-01-24T03:53:52","modified_gmt":"2026-01-24T03:53:52","slug":"pro-ezgc-chromatogram-modeler-1-entering-compound-lists-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3632-ja\/pro-ezgc-chromatogram-modeler-1-entering-compound-lists-japan","title":{"rendered":"Pro EZGC Chromatogram Modeler\u306e\u6709\u52b9\u6d3b\u7528\u3010\u7b2c2\u56de\u30111\uff0e\u5316\u5408\u7269\u30ea\u30b9\u30c8\u306e\u5165\u529b\u65b9\u6cd5"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-4-3 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Pro EZGC\u00ae Chromatogram Modeler: Entering Compound Lists - Intermediate Use, Part 1 of 4\" width=\"720\" height=\"540\" src=\"https:\/\/www.youtube.com\/embed\/Qcag9-ew7KE?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"512\" height=\"373\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1.png\" alt=\"\" class=\"wp-image-29853\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1.png 512w, https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1-300x219.png 300w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"447\" height=\"528\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12.png\" alt=\"\" class=\"wp-image-29859\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12.png 447w, https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12-254x300.png 254w\" sizes=\"auto, (max-width: 447px) 100vw, 447px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">YouTube\u753b\u9762\u53f3\u4e0b\u306b\u3042\u308b\u8a2d\u5b9a\u30dc\u30bf\u30f3\u2699\u304b\u3089Subtitles\/CC\u3092\u9078\u3073\u3001Japanese\u306b\u30c1\u30a7\u30c3\u30af\u3092\u5165\u308c\u308b\u3068\u65e5\u672c\u8a9e\u5b57\u5e55\u3042\u308a\u3067\u52d5\u753b\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002<strong>\u306a\u304a\u3001\u73fe\u884c\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30a4\u30b9\u306b\u304a\u3044\u3066\u8868\u793a\u304c\u5909\u66f4\u3055\u308c\u3066\u3044\u308b\u7b87\u6240\u304c\u3042\u308a\u307e\u3059\u3002\u4e0b\u65b9\u306b\u3042\u308b\u300c\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u300d\u3067\u8a72\u5f53\u7b87\u6240\uff08\u8d64\u5b57\uff09\u3092\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pro <em>EZ<\/em>GC Chromatogram Modeler\u306e\u6709\u52b9\u6d3b\u7528<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306ePro <em>EZ<\/em>GC Chromatogram Modeler\uff08\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30b7\u30df\u30e5\u30ec\u30fc\u30bf\u30fc\u3068\u3057\u3066\u3082\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\uff09\u306f\u3001\u30dd\u30ea\u30de\u30fc\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u7528\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u64cd\u4f5c\u304c\u30b7\u30f3\u30d7\u30eb\u3067\u3042\u308a\u306a\u304c\u3089\u3001\u9ad8\u5ea6\u306a\u30aa\u30d7\u30b7\u30e7\u30f3\u3082\u5099\u3048\u3066\u3044\u308b\u305f\u3081\u3001GC\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306e\u5927\u304d\u306a\u52a9\u3051\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns42505_a4ea6d-b5{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:flex-start;align-items:center;}.kt-btns42505_a4ea6d-b5 .kt-button{font-weight:normal;font-style:normal;}.kt-btns42505_a4ea6d-b5 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns42505_a4ea6d-b5 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns42505_a4ea6d-b5 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns42505_a4ea6d-b5 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns42505_a4ea6d-b5 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns42505_a4ea6d-b5 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns42505_a4ea6d-b5 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns42505_a4ea6d-b5\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn42505_a6a332-db.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn42505_a6a332-db.kb-button{padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn42505_a6a332-db.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn42505_a6a332-db.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn42505_a6a332-db kt-btn-size-large kt-btn-width-type-auto kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/ez.restek.com\/proezgc\/en\/ja\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"kt-btn-inner-text\">Get Started<\/span><\/a><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Pro&nbsp;<em>EZ<\/em>GC Chromatogram Modeler \u64cd\u4f5c\u65b9\u6cd5\u89e3\u8aac\u52d5\u753b<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3641-ja\/pro-ezgc-chromatogram-modeler-introduction-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3641-ja\/pro-ezgc-chromatogram-modeler-introduction-japan\">\u3010\u7b2c1\u56de\u3011\u6982\u8981<\/a><\/li>\n\n\n\n<li>\u3010\u7b2c2\u56de\u30111. \u5316\u5408\u7269\u30ea\u30b9\u30c8\u306e\u5165\u529b\u65b9\u6cd5<\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3633-ja\/pro-ezgc-chromatogram-modeler-2-interface-details-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3633-ja\/pro-ezgc-chromatogram-modeler-2-interface-details-japan\">\u3010\u7b2c3\u56de\u30112. \u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9\u8a73\u8aac<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3634-ja\/pro-ezgc-chromatogram-modeler-3-refining-your-model-part-1-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3634-ja\/pro-ezgc-chromatogram-modeler-3-refining-your-model-part-1-japan\">\u3010\u7b2c4\u56de\u30113. \u30e2\u30c7\u30eb\u6539\u826f\u65b9\u6cd5 Part 1\uff08\u65e5\u672c\u8a9e\u6e96\u5099\u4e2d\uff09<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3635-ja\/pro-ezgc-chromatogram-modeler-4-refining-your-model-part-2-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3635-ja\/pro-ezgc-chromatogram-modeler-4-refining-your-model-part-2-japan\">\u3010\u7b2c5\u56de\u30114. \u30e2\u30c7\u30eb\u6539\u826f\u65b9\u6cd5 Part 2\uff08\u65e5\u672c\u8a9e\u6e96\u5099\u4e2d\uff09<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3636-ja\/pro-ezgc-chromatogram-modeler-5-using-multiple-libraries-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3636-ja\/pro-ezgc-chromatogram-modeler-5-using-multiple-libraries-japan\">\u3010\u7b2c6\u56de\u30115. \u8907\u6570\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u5229\u7528\u65b9\u6cd5\uff08\u65e5\u672c\u8a9e\u6e96\u5099\u4e2d\uff09<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3637-ja\/pro-ezgc-chromatogram-modeler-6-global-resolution-constraints-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3637-ja\/pro-ezgc-chromatogram-modeler-6-global-resolution-constraints-japan\">\u3010\u7b2c7\u56de\u30116. \u5168\u4f53\u7684\u5206\u96e2\u5ea6\u8981\u4ef6\uff08\u65e5\u672c\u8a9e\u6e96\u5099\u4e2d\uff09<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3638-ja\/pro-ezgc-chromatogram-modeler-7-compound-specific-resolution-constraints-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3638-ja\/pro-ezgc-chromatogram-modeler-7-compound-specific-resolution-constraints-japan\">\u3010\u7b2c8\u56de\u30117. \u5316\u5408\u7269\u3054\u3068\u306e\u5206\u96e2\u5ea6\u8981\u4ef6\uff08\u65e5\u672c\u8a9e\u6e96\u5099\u4e2d\uff09<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3639-ja\/pro-ezgc-chromatogram-modeler-8-adding-oven-ramps-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3639-ja\/pro-ezgc-chromatogram-modeler-8-adding-oven-ramps-japan\">\u3010\u7b2c9\u56de\u30118. \u6607\u6e29\u30ec\u30fc\u30c8\u306e\u8ffd\u52a0\uff08\u65e5\u672c\u8a9e\u6e96\u5099\u4e2d\uff09<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3640-ja\/pro-ezgc-chromatogram-modeler-9-injection-considerations-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3640-ja\/pro-ezgc-chromatogram-modeler-9-injection-considerations-japan\">\u3010\u7b2c10\u56de\u30119. \u6ce8\u5165\u65b9\u6cd5\u5225\u306e\u691c\u8a0e\u4e8b\u9805\uff08\u65e5\u672c\u8a9e\u6e96\u5099\u4e2d\uff09<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Connect with Us<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">YouTube:&nbsp;<a href=\"https:\/\/www.youtube.com\/user\/RestekCorp\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.youtube.com\/user\/RestekCorp<\/a>&nbsp;<br>LinkedIn:&nbsp;<a href=\"https:\/\/www.linkedin.com\/company\/restek-corporation\/\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.linkedin.com\/company\/restek-corporation\/<\/a><br>Facebook:&nbsp;<a href=\"https:\/\/www.facebook.com\/RestekCorporation\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.facebook.com\/RestekCorporation<\/a>&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6ce8\uff09\u73fe\u884c\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30a4\u30b9\u306b\u304a\u3044\u3066\u8868\u793a\u304c\u5909\u66f4\u3055\u308c\u3066\u3044\u308b\u7b87\u6240\u3092\u8d64\u5b57\u306b\u3057\u3066\u3044\u307e\u3059\u3002\u52d5\u753b\u306e\u5185\u5bb9\u3068\u5b57\u5e55\u3068\u306e\u9055\u3044\u306f\u3053\u3061\u3089\u3067\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u3093\u306b\u3061\u306f\uff01Amanda Rigdon\u3067\u3059\u3002\u3010\u7b2c1\u56de\u3011\u306f\u3054\u89a7\u9802\u3051\u307e\u3057\u305f\u3067\u3057\u3087\u3046\u304b\u3002\u3053\u3061\u3089\u306f\u3001Pro <em>EZ<\/em>GC Chromatogram Modeler\u306e\u57fa\u672c\u30fb\u4e2d\u7d1a\u30fb\u4e0a\u7d1a\u7de8\u306b\u308f\u305f\u308b\u4f7f\u3044\u65b9\u3092\u7d39\u4ecb\u3059\u308bRestek\u52d5\u753b\u30b7\u30ea\u30fc\u30ba\u306e\u7b2c\u4e8c\u5f3e\u3067\u3059\u3002\u3010\u7b2c1\u56de\u3011\u3067\u306f\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u30c4\u30fc\u30eb\u3068\u3057\u3066Modeler\u306e\u512a\u308c\u305f\u70b9\u3092\u3054\u7d39\u4ecb\u3057\u3001Modeler\u306e\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9\u306b\u3064\u3044\u3066\u3082\u7c21\u5358\u306b\u89e6\u308c\u307e\u3057\u305f\u3002\u7b2c\u4e8c\u5f3e\u3067\u3042\u308b\u3010\u7b2c2\u56de\u3011\u304b\u3089\u3010\u7b2c5\u56de\u3011\u306f\u3055\u3089\u306b\u8e0f\u307f\u8fbc\u3093\u3060Modeler\u306e\u6d3b\u7528\u65b9\u6cd5\uff08\u4e2d\u7d1a\uff09\u3067\u3059\u3002Pro EZGC Chromatogram Modeler\u306e\u7279\u9577\u306e\u4e00\u3064\u306f\u3001\u521d\u3081\u3066\u4f7f\u3046\u65b9\u3084\u30e9\u30a4\u30c8\u30e6\u30fc\u30b6\u30fc\u3067\u3082\u7279\u5225\u306a\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306a\u3057\u306b\u76f4\u611f\u7684\u306b\u4f7f\u3048\u3001\u4e0a\u7d1a\u8005\u306b\u3088\u308b\u9ad8\u5ea6\u306a\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306b\u3082\u5bfe\u5fdc\u3067\u304d\u308b\u70b9\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3055\u3066\u3001\u4eca\u56de\u8aac\u660e\u3059\u308b\u306e\u306f\u3001\u5316\u5408\u7269\u30ea\u30b9\u30c8\u306e\u5165\u529b\u65b9\u6cd5\u3001\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9\u306e\u8a73\u7d30\u3001\u305d\u3057\u3066\u3001\u30e2\u30c7\u30eb\u6539\u826f\u65b9\u6cd5\u3067\u3059\u3002\u305d\u308c\u3067\u306f\u3001\u30c7\u30e2\u3067\u898b\u3066\u3044\u304d\u307e\u3057\u3087\u3046\u3002\u3053\u306e\u753b\u9762\u306fModeler\u3092\u7acb\u3061\u4e0a\u3052\u308b\u3068\u3044\u3064\u3067\u3082\u6700\u521d\u306b\u51fa\u3066\u304f\u308b\u753b\u9762\u3067\u3059\u3002Modeler\u306f\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u30c4\u30fc\u30eb\u3067\u3042\u308a\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306e\u6700\u521d\u306e\u30b9\u30c6\u30c3\u30d7\u306f\u5316\u5408\u7269\u30ea\u30b9\u30c8\u4f5c\u6210\u3067\u3059\u3002\u3068\u3044\u3046\u3053\u3068\u3067\u3001\u5316\u5408\u7269\u30ea\u30b9\u30c8\u306e\u5165\u529b\u65b9\u6cd5\u304b\u3089\u898b\u3066\u3044\u304d\u307e\u3059\u3002\u3010\u7b2c1\u56de\u3011\u3067\u3082\u8aac\u660e\u3057\u307e\u3057\u305f\u304c\u3001\u5316\u5408\u7269\u30ea\u30b9\u30c8\u306e\u5165\u529b\u306b\u306f\u5316\u5408\u7269\u540d\u3092\u624b\u5165\u529b\u3059\u308b\u65b9\u6cd5\u3068\u30ea\u30b9\u30c8\u3092\u8cbc\u308a\u4ed8\u3051\u308b\u65b9\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002\u30ea\u30b9\u30c8\u5185\u306e\u5316\u5408\u7269\u3092\u30e2\u30c7\u30eb\u5316\u3059\u308b\u306b\u306f\u3001<strong>\u300cSolve\uff08\u691c\u7d22\uff09\u300d<\/strong>\u3092\u30af\u30ea\u30c3\u30af\u3059\u308b\u3060\u3051\u3067\u3059\u3002\u753b\u9762\u53f3\u5074\u306b\u51fa\u3066\u304d\u3066\u3044\u308b\u3088\u3046\u306b\u3001Modeler\u304c\u30ab\u30e9\u30e0\u3068\u5316\u5408\u7269\u306e\u30c7\u30fc\u30bf\u30d9\u30fc\u30b9\u3092\u691c\u7d22\u3057\u3001\u5165\u529b\u3055\u308c\u305f\u5316\u5408\u7269\u306e\u6700\u9069\u306a\u30e2\u30c7\u30eb\u3092\u751f\u6210\u3057\u307e\u3057\u305f\u3002\u753b\u9762\u5de6\u5074\u306e\u30d7\u30eb\u30c0\u30a6\u30f3\u30e1\u30cb\u30e5\u30fc\u304b\u3089\u3001\u6700\u9069\u5316\u3055\u308c\u305f\u4ed6\u306e\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3068\u3057\u3066VMS\u3068Stabilwax\u304c\u9078\u629e\u3067\u304d\u308b\u306e\u304c\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002\u3053\u3053\u306b\u8868\u793a\u3055\u308c\u305f\u30ab\u30e9\u30e0\u304c\u30e9\u30dc\u306b\u306a\u3044\u5834\u5408\u306f\u3069\u3046\u3057\u305f\u3089\u3088\u3044\u3067\u3057\u3087\u3046\u304b\u3002\u6700\u9ad8\u306e\u5206\u96e2\u3092\u5f97\u305f\u3044\u3068\u3044\u3046\u3088\u308a\u3082\u3001\u4eca\u30e9\u30dc\u306b\u3042\u308b\u30ab\u30e9\u30e0\u3067\u5165\u529b\u3057\u305f\u5316\u5408\u7269\u30ea\u30b9\u30c8\u304c\u3069\u3046\u5206\u96e2\u3055\u308c\u308b\u304b\u3092\u78ba\u8a8d\u3057\u305f\u3044\u3060\u3051\u306a\u3089\u3069\u3046\u3059\u3079\u304d\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u3088\u3046\u306a\u6642\u306b\u3082Pro <em>EZ<\/em>GC Chromatogram Modeler\u306f\u304a\u4f7f\u3044\u3044\u305f\u3060\u3051\u307e\u3059\u3002\u3054\u7559\u610f\u9802\u304d\u305f\u3044\u306e\u306f\u3001\u5316\u5408\u7269\u30ea\u30b9\u30c8\u306e\u5165\u529b\u65b9\u6cd5\u304c\u5909\u308f\u308b\u3053\u3068\u3067\u3059\u3002\u5316\u5408\u7269\u540d\u3084CAS\u756a\u53f7\u3067\u691c\u7d22\u3059\u308b\u306e\u3067\u306f\u306a\u304f\u3001phase\uff08\u56fa\u5b9a\u76f8\uff09\u3067Pro EZGC\u30c7\u30fc\u30bf\u30d9\u30fc\u30b9\u3092\u691c\u7d22\u3057\u307e\u3059\u3002<strong>\u300cSearch by Phase\uff08\u56fa\u5b9a\u76f8\u3067\u691c\u7d22\uff09\u300d<\/strong>\u3092\u30af\u30ea\u30c3\u30af\u3059\u308b\u30682\u3064\u306e\u30c9\u30ed\u30c3\u30d7\u30c0\u30a6\u30f3\u30ea\u30b9\u30c8\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u6700\u521d\u306e\u884c\u3067\u306f\u4f7f\u7528\u3059\u308b\u30ab\u30e9\u30e0\u306e\u56fa\u5b9a\u76f8\u3092\u9078\u629e\u3057\u307e\u3059\u3002\u30e9\u30dc\u306b\u3042\u3063\u305f\u306e\u304cRtx-1\u3060\u3063\u305f\u3068\u3057\u3066\u3001Rtx-1\u3092\u9078\u629e\u3057\u307e\u3057\u3087\u3046\u3002\u56fa\u5b9a\u76f8\u3092\u9078\u629e\u3057\u305f\u3089\u3001\u5316\u5408\u7269\u3092\u691c\u7d22\u3059\u308b\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u9078\u629e\u304c\u5fc5\u8981\u3067\u3059\u3002\u4e00\u5ea6\u306b1\u3064\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u304b\u3089\u3057\u304b\u5316\u5408\u7269\u3092\u9078\u629e\u3067\u304d\u306a\u3044\u3053\u3068\u306b\u3054\u6ce8\u610f\u304f\u3060\u3055\u3044\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u5206\u6790\u5bfe\u8c61\u306e\u5316\u5408\u7269\u304c\u8907\u6570\u306e\u30af\u30e9\u30b9\u306b\u6e21\u308b\u5834\u5408\u3001<strong>\u300cSearch by Name\uff08\u5316\u5408\u7269\u3067\u691c\u7d22\uff09\u300d<\/strong>\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002<strong>\u300cSearch by Name\uff08\u5316\u5408\u7269\u3067\u691c\u7d22\uff09\u300d<\/strong>\u306e\u8ffd\u52a0\u6a5f\u80fd\u306b\u3064\u3044\u3066\u306f\u7b2c\u4e09\u5f3e\u306e\u3010\u7b2c6\u56de\u3011\u304b\u3089\u3010\u7b2c10\u56de\u3011\u3067\u8a73\u3057\u304f\u8aac\u660e\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4eca\u56de\u306e\u30b1\u30fc\u30b9\u3067\u306f\u3001\u5206\u6790\u5bfe\u8c61\u306e\u5316\u5408\u7269\u30af\u30e9\u30b9\u306f1\u3064\u3067\u3001\u65e2\u306b\u30e9\u30dc\u306b\u3042\u308b\u30ab\u30e9\u30e0\u3067\u306e\u5206\u96e2\u3092\u78ba\u8a8d\u3057\u305f\u3044\u305f\u3081\u3001<strong>\u300cSearch by Phase\uff08\u56fa\u5b9a\u76f8\u3067\u691c\u7d22\uff09\u300d<\/strong>\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u30d7\u30eb\u30c0\u30a6\u30f3\u306b\u306fRtx-1\u30ab\u30e9\u30e0\u3067\u751f\u6210\u3055\u308c\u305f\u30ea\u30b9\u30c8\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u4eca\u56de\u306fVOC\u3092\u898b\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u56fa\u5b9a\u76f8\u3068\u30e9\u30a4\u30d6\u30e9\u30ea\u3092\u9078\u629e\u3059\u308b\u3068\u3001\u305d\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u5185\u306b\u3042\u308b\u5316\u5408\u7269\u304c\u3059\u3079\u3066\u30ea\u30b9\u30c8\u30a2\u30c3\u30d7\u3055\u308c\u307e\u3059\u3002\u76ee\u7684\u306e\u5316\u5408\u7269\u3092\u9078\u629e\u3059\u308b\u305f\u3081\u306b\u30ea\u30b9\u30c8\u3092\u30b9\u30af\u30ed\u30fc\u30eb\u30c0\u30a6\u30f3\u3057\u3066\u3044\u304d\u307e\u3059\u3002\u300cacetonitrile\u300d\u3092\u63a2\u3057\u3066\u3044\u307e\u3059\u304c\u2026\u3042\u308a\u307e\u3057\u305f\uff01\u30ea\u30b9\u30c8\u306b\u5316\u5408\u7269\u3092\u8ffd\u52a0\u3059\u308b\u65b9\u6cd5\u306f\u3001\u305d\u306e\u5316\u5408\u7269\u540d\u3092\u30af\u30ea\u30c3\u30af\u3059\u308b\u3060\u3051\u3067\u3059\u3002\u300cacetonitrile\u300d\u304c\u3053\u306e\u3088\u3046\u306b\u9752\u8272\u306b\u30cf\u30a4\u30e9\u30a4\u30c8\u3055\u308c\u307e\u3057\u305f\u3002\u30ea\u30b9\u30c8\u30dc\u30c3\u30af\u30b9\u306e\u4e0b\u3092\u898b\u3066\u4e0b\u3055\u3044\u3002\u5316\u5408\u7269\u30ea\u30b9\u30c8\u5185\u30671 compound selected\uff081\u6210\u5206\u9078\u629e\uff09\u3068\u306a\u3063\u3066\u3044\u308b\u306e\u304c\u5206\u304b\u308a\u307e\u3059\u3002\u300cacetonitrile\u300d\u306e\u53f3\u7aef\u306b\u3042\u308b\u6fc3\u3044\u9752\u8272\u306e\u30c1\u30a7\u30c3\u30af\u30dc\u30c3\u30af\u30b9\u3092\u30af\u30ea\u30c3\u30af\u3059\u308b\u3068\u3001\u767d\u3044\u30c1\u30a7\u30c3\u30af\u304c\u5165\u308a\u307e\u3059\u3002\u5206\u96e2\u3059\u3079\u304d\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u3068\u3057\u3066\u300cacetonitrile\u300d\u304c\u8a2d\u5b9a\u3055\u308c\u305f\u3001\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u5206\u96e2\u3059\u3079\u304d\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u3092\u8a2d\u5b9a\u3059\u308b\u3068\u3001\u30e2\u30c7\u30eb\u306b\u5bfe\u3057\u3066\u305d\u306e\u5316\u5408\u7269\u56fa\u6709\u306e\u5206\u96e2\u5ea6\u8981\u4ef6\u304c\u9069\u7528\u3055\u308c\u307e\u3059\u3002\u5206\u96e2\u5ea6\u8981\u4ef6\u306b\u3064\u3044\u3066\u306f\u3010\u7b2c7\u56de\u3011\u3068\u3010\u7b2c8\u56de\u3011\u3067\u8aac\u660e\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4eca\u56de\u306f\u3053\u306e\u5316\u5408\u7269\u306e\u5206\u96e2\u5ea6\u8981\u4ef6\u3092\u9069\u7528\u3057\u306a\u3044\u306e\u3067\u3001\u30c1\u30a7\u30c3\u30af\u30dc\u30c3\u30af\u30b9\u3092\u518d\u5ea6\u30af\u30ea\u30c3\u30af\u3057\u3001\u9752\u8272\u306e\u30cf\u30a4\u30e9\u30a4\u30c8\u3060\u3051\u306b\u623b\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u3063\u3066\u3053\u306e\u5316\u5408\u7269\u306f\u9078\u629e\u3055\u308c\u3066\u3044\u308b\u3060\u3051\u3068\u3044\u3046\u72b6\u614b\u3067\u3001\u5206\u96e2\u3059\u3079\u304d\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u3067\u306f\u306a\u304f\u306a\u308a\u307e\u3059\u3002\u3082\u3046\u4e00\u3064\u306e\u5316\u5408\u7269\u306e\u691c\u7d22\u65b9\u6cd5\u306f\u3001<strong>\u300cFilter Compounds\uff08\u5316\u5408\u7269\u30d5\u30a3\u30eb\u30bf\u30fc\uff09\u300d<\/strong>\u306b\u5316\u5408\u7269\u540d\u307e\u305f\u306fCAS\u756a\u53f7\u3092\u5165\u529b\u3059\u308b\u3001\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u3067\u306f\u3001\u3053\u306e\u65b9\u6cd5\u3067\u300cdichloromethane\u300d\u3092\u63a2\u3057\u3066\u307f\u307e\u3057\u3087\u3046\u3002\uff08\u300cdichloromethane\u300d\u3092\u5316\u5408\u7269\u30d5\u30a3\u30eb\u30bf\u30fc\u6b04\u306b\u5165\u529b\uff09\u3053\u306e\u3088\u3046\u306b\u5165\u529b\u9014\u4e2d\u3067\u30ea\u30b9\u30c8\u306f\u7d5e\u308a\u8fbc\u307e\u308c\u3066\u3044\u304d\u307e\u3059\u3002\u3042\u308b\u7a0b\u5ea6\u7d5e\u308a\u8fbc\u307e\u308c\u305f\u4e2d\u304b\u3089\u300cdichloromethane\u300d\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u304c\u51fa\u6765\u307e\u3059\u3002\u307e\u305f\u306f\u3001\u6700\u5f8c\u307e\u3067\u5165\u529b\u3057\u3066\u3001\u305d\u306e\u5165\u529b\u304c\u6b63\u3057\u3051\u308c\u3070\u30ea\u30b9\u30c8\u5185\u306b\u306f\u30de\u30c3\u30c1\u3057\u305f\u7d50\u679c\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u7d5e\u308a\u8fbc\u307e\u308c\u3066\u3044\u306a\u3044\u30ea\u30b9\u30c8\u306b\u623b\u3059\u306b\u306f\u3001<strong>\u300cFilter Compounds(\u5316\u5408\u7269\u30d5\u30a3\u30eb\u30bf\u30fc)\u300d<\/strong>\u30dc\u30c3\u30af\u30b9\u306e\u53f3\u306b\u3042\u308b\u300cx\u300d\u30dc\u30bf\u30f3\u3092\u62bc\u3059\u304b\u3001\u5225\u306e\u5316\u5408\u7269\u540d\u3092\u5165\u529b\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002\u4eca\u56de\u306e\u30ea\u30b9\u30c8\u4f5c\u6210\u3092\u7d9a\u3051\u307e\u3057\u3087\u3046\u3002\u6b21\u306b\u300cTrans-1,2,dichloroethene\u300d\u3068\u300cHexane (C6)\u300d\u3092\u691c\u7d22\u3057\u307e\u3059\u3002\u3054\u89a7\u306e\u901a\u308a\u3001\u540c\u7fa9\u8a9e\u304c\u30ea\u30b9\u30c8\u306b\u3042\u304c\u3063\u3066\u304d\u307e\u3059\u306e\u3067\u3001\u540c\u7fa9\u8a9e\u691c\u7d22\u3092\u3057\u307e\u3059\u3002\u300cnitromethane\u300d\u3082\u691c\u7d22\u3057\u307e\u3059\u3002\u3053\u3053\u3067\u306f\u3001\u691c\u7d22\u3057\u3066\u3044\u308b\u5316\u5408\u7269\u3067\u306f\u306a\u3044\u3082\u306e\u304c\u30de\u30c3\u30c1\u3057\u305f\u30d5\u30a3\u30eb\u30bf\u30fc\u7d50\u679c\u3068\u3057\u3066\u8868\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u8868\u793a\u3055\u308c\u3066\u3044\u308b\u5316\u5408\u7269\u540d\u304c\u691c\u7d22\u3057\u3066\u3044\u308b\u5316\u5408\u7269\u540d\u3068\u4f3c\u3066\u3044\u308b\u5834\u5408\u3001\u30b9\u30da\u30eb\u30df\u30b9\u3092\u8003\u616e\u3057\u3066\u30d5\u30a3\u30eb\u30bf\u30fc\u7d50\u679c\u306b\u51fa\u3066\u304f\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u307e\u3063\u305f\u304f\u4f3c\u3066\u3044\u306a\u3044\u540d\u524d\u306e\u5316\u5408\u7269\u304c\u30d5\u30a3\u30eb\u30bf\u30fc\u7d50\u679c\u3068\u3057\u3066\u8868\u793a\u3055\u308c\u308b\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002\u306a\u305c\u306a\u3089\u3001\u8868\u793a\u3055\u308c\u305f\u5316\u5408\u7269\u306e\u540c\u7fa9\u8a9e\u306e\u4e2d\u306b\u3001\u691c\u7d22\u3057\u3066\u3044\u308b\u5316\u5408\u7269\u306b\u4f3c\u3066\u3044\u308b\u3082\u306e\u304c\u3042\u308b\u304b\u3089\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3067\u3082\u4eca\u56de\u306e\u5834\u5408\u3001\u300cnitromethane\u300d\u306f\u30e9\u30a4\u30d6\u30e9\u30ea\u5185\u306b\u3042\u308a\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u7d9a\u3044\u3066\u6b8b\u308a\u306e\u76ee\u7684\u306e\u5316\u5408\u7269\u306b\u3064\u3044\u3066\u3082\u3053\u306e\u30d7\u30ed\u30bb\u30b9\u3092\u5b9f\u884c\u3057\u307e\u3059\u3002\u9332\u753b\u306e\u5229\u70b9\u3092\u6d3b\u304b\u3057\u305f\u30b7\u30e7\u30fc\u30c8\u30ab\u30c3\u30c8\u3067\u3001\u30c7\u30fc\u30bf\u30d9\u30fc\u30b9\u304b\u3089\u62bd\u51fa\u3057\u305f\u76ee\u7684\u306e\u5316\u5408\u7269\u3092\u8868\u793a\u3057\u307e\u3059\u3002\u3053\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u306b\u306f28\u500b\u306e\u76ee\u7684\u306e\u5316\u5408\u7269\u306e\u3046\u306118\u500b\u306e\u5316\u5408\u7269\u304c\u3042\u308a\u307e\u3057\u305f\u3002\u7406\u60f3\u7684\u3068\u306f\u8a00\u3048\u307e\u305b\u3093\u304c\u3001\u3053\u306e\u30ab\u30e9\u30e0\u3067\u5b9f\u969b\u8a66\u3059\u4fa1\u5024\u304c\u3042\u308b\u304b\u3069\u3046\u304b\u3092\u6c7a\u3081\u308b\u30d2\u30f3\u30c8\u306b\u306f\u306a\u308a\u307e\u3059\u3002\u601d\u3044\u51fa\u3057\u3066\u307b\u3057\u3044\u306e\u306f\u3001\u3053\u306e\u6642\u70b9\u307e\u3067\u3001\u5316\u5408\u7269\u540d\u3092\u5165\u529b\u3059\u308b\u6642\u9593\u3001\u3068\u3044\u3046\u6295\u8cc7\u3057\u304b\u3057\u3066\u3044\u306a\u3044\u3053\u3068\u3067\u3059\u3002Rtx-1\u3067\u30e2\u30c7\u30eb\u751f\u6210\u3059\u308b\u305f\u3081\u306b\u3057\u305f\u3053\u3068\u306f\u3001<strong>\u300cSolve\uff08\u691c\u7d22\uff09\u300d<\/strong>\u3092\u30af\u30ea\u30c3\u30af\u3001\u3060\u3051\u3067\u3059\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Pro EZGC Chromatogram Modeler\u306e\u4e2d\u7d1a\u6d3b\u7528\u6cd5\u3092\u5fb9\u5e95\u89e3\u8aac\u3002\u5316\u5408\u7269\u30ea\u30b9\u30c8\u306e\u52b9\u7387\u7684\u306a\u5165\u529b\u3001\u540c\u7fa9\u8a9e\u691c\u7d22\u3001\u30d5\u30a3\u30eb\u30bf\u30fc\u6a5f\u80fd\u306e\u4f7f\u3044\u65b9\u3092\u5b9f\u4f8b\u4ed8\u304d\u3067\u7d39\u4ecb\u3002\u5206\u6790\u6761\u4ef6\u306e\u691c\u8a0e\u6642\u9593\u3092\u5927\u5e45\u306b\u77ed\u7e2e\u3059\u308b\u30d2\u30f3\u30c8\u3082\u6e80\u8f09\u3067\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":41777,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[774],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2564,2552],"resource-technique":[2340],"ppma_author":[414],"class_list":["post-42505","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-ja","product-library-gc-columns-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":774,"label":"\u52d5\u753b"}],"product-library":[{"value":2564,"label":"GC \u30ab\u30e9\u30e0"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3632-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":774,"name":"\u52d5\u753b","slug":"videos-ja","term_group":0,"term_taxonomy_id":774,"taxonomy":"category","description":"","parent":0,"count":139,"filter":"raw","cat_ID":774,"category_count":139,"category_description":"","cat_name":"\u52d5\u753b","category_nicename":"videos-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42505","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=42505"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42505\/revisions"}],"predecessor-version":[{"id":84508,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42505\/revisions\/84508"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/41777"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=42505"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=42505"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=42505"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=42505"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=42505"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=42505"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=42505"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=42505"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=42505"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}