{"id":42520,"date":"2020-10-18T18:30:00","date_gmt":"2020-10-18T18:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/replacing-a-ptfe-frit-in-an-agilent-lc-pump\/"},"modified":"2026-08-11T18:21:31","modified_gmt":"2026-08-11T18:21:31","slug":"replacing-a-ptfe-frit-in-an-agilent-lc-pump","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/videos-fr\/gnav3646\/replacing-a-ptfe-frit-in-an-agilent-lc-pump","title":{"rendered":"Replacing a PTFE Frit in an Agilent LC Pump"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Replacing a PTFE Frit in an Agilent LC Pump\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/mt3wcpEv1Wc?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Description<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The PTFE frits in your Agilent LC pumps will need to be replaced from time to time as part of a routine maintenance program. Over time, these frits will accumulate contamination and can then start to increase system pressure. Replacing them is pretty straightforward\u2014it only takes about ten minutes,&nbsp;and we can show you how.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Additional Resources<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/articles\/routine-lc-maintenance\" target=\"_blank\" rel=\"noopener\">Routine LC Maintenance<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/chromablography\/building-up-pressure-on-hplc\" target=\"_blank\" rel=\"noopener\">Building up pressure on HPLC?<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Restek Recommended Tools &amp; Parts<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/p\/25466\" target=\"_blank\" rel=\"noopener\">PTFE Frits<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/p\/25270\" target=\"_blank\" rel=\"noopener\">Pump PM Kit<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transcript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hi, everyone. Thanks for joining us for this Restek Tip. Our topic today is PTFE frit replacement in the Agilent series pumps. Both the 1100 and the 1200 pumps have a PTFE frit in the purge valve. This helps keep particulate matter from&nbsp;seal&nbsp;ware&nbsp;or any particles in the mobile phase from getting into the pump. The recommended replacement schedule for these frits is every three months, but if you happen to notice an increase in system pressure and have isolated it to the pump, this is a good place to check. Replacing the frit is very easy. We&#8217;re going to go through the steps with you now.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">First,&nbsp;open the purge valve to release the pressure then remove the outlet capillary and drain lines. Next,&nbsp;unscrew the valve with the 14 mm&nbsp;flat&nbsp;wrench&nbsp;provided in the pump accessory kit.&nbsp;Remove the plastic cap and the gold seal, being careful not to damage the seal in any way. While they are reusable for several times, you want to always inspect it and make sure there&#8217;s no particulates or signs of wear. If it&#8217;s dirty or misshapen in any way, don&#8217;t put it back into the pump, because there&#8217;s a good chance that it will leak. Use&nbsp;tweezers&nbsp;to remove the existing frit. Install a new frit with the slotted end pointing up. This ensures that the area of the frit with the most surface area is facing the direction of solvent flow. Replace the gold seal on the plastic cap. Install the completed assembly back onto the pump&nbsp;making sure to orient the valve so the drain stem is pointing down. Hold the valve in place while tightening with the wrench&nbsp;about a quarter turn past hand-tight.&nbsp;Then reattach the drain line and outlet capillary.&nbsp;It really is that simple. It takes about ten minutes, and it&#8217;s something you can easily do yourself to keep your work flowing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Thanks for joining us. Watch for more tips from your friends at Restek.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Don\u2019t forget your frits! Watch how to replace your Agilent LC PTFE pump frits in this Restek Tip video and keep your liquid chromatography at peak performance.<\/p>\n","protected":false},"author":11,"featured_media":41232,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[771],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-42520","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-fr"],"acf":[],"taxonomy_info":{"category":[{"value":771,"label":"Vid\u00e9os"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3646-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":771,"name":"Vid\u00e9os","slug":"videos-fr","term_group":0,"term_taxonomy_id":771,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":771,"category_count":138,"category_description":"","cat_name":"Vid\u00e9os","category_nicename":"videos-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42520","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=42520"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42520\/revisions"}],"predecessor-version":[{"id":64147,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42520\/revisions\/64147"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/41232"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=42520"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=42520"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=42520"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=42520"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=42520"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=42520"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=42520"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=42520"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=42520"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}