{"id":42562,"date":"2022-01-03T05:00:00","date_gmt":"2022-01-03T05:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-optimizing-splitless-injection\/"},"modified":"2026-01-13T22:38:35","modified_gmt":"2026-01-13T22:38:35","slug":"japanese-optimizing-splitless-injection","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3699-ja\/japanese-optimizing-splitless-injection","title":{"rendered":"\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306e\u6700\u9069\u5316"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Optimizing Splitless Injections\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/MtFlABnj8G4?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"512\" height=\"373\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1.png\" alt=\"\" class=\"wp-image-29853\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1.png 512w, https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1-300x219.png 300w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"447\" height=\"528\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12.png\" alt=\"\" class=\"wp-image-29859\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12.png 447w, https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12-254x300.png 254w\" sizes=\"auto, (max-width: 447px) 100vw, 447px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">YouTube\u753b\u9762\u53f3\u4e0b\u306b\u3042\u308b\u8a2d\u5b9a\u30dc\u30bf\u30f3\u2699\u304b\u3089Subtitles\/CC\u3092\u9078\u3073\u3001Japanese\u306b\u30c1\u30a7\u30c3\u30af\u3092\u5165\u308c\u308b\u3068\u65e5\u672c\u8a9e\u5b57\u5e55\u3042\u308a\u3067\u52d5\u753b\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u5185\u5bb9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306f\u5fae\u91cf\u5206\u6790\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u5206\u6790\u3092\u6700\u5927\u9650\u306b\u751f\u304b\u3059\u305f\u3081\u306b\u306f\u3001\u30b7\u30b9\u30c6\u30e0\u3092\u6700\u9069\u5316\u3059\u308b\u3053\u3068\u304c\u5927\u5207\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u4f55\u3092\u6700\u9069\u5316\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u3001\u3069\u306e\u3088\u3046\u306a\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u308b\u306e\u3067\u3057\u3087\u3046\u304b\uff1f&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306eRestek Tip\u3067\u306f\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3092\u6700\u9069\u5316\u3059\u308b\u65b9\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u306e\u30db\u30fc\u30eb\u30c9\u30bf\u30a4\u30e0\u306e\u91cd\u8981\u6027\u3092\u304a\u8a71\u3057\u3059\u308b\u524d\u306b\u3001\u30e9\u30a4\u30ca\u30fc\u9078\u629e\u304b\u3089\u59cb\u3081\u307e\u3059\u3002\u6b21\u3044\u3067\u3001\u6ce8\u5165\u53e3\u6e29\u5ea6\u306e\u6700\u9069\u5316\u306b\u7126\u70b9\u3092\u5f53\u3066\u3001\u6700\u5f8c\u306b\u30aa\u30fc\u30d6\u30f3\u521d\u671f\u6e29\u5ea6\u3092\u6700\u9069\u5316\u3057\u307e\u3059\u3002&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u95a2\u9023\u8a18\u4e8b<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4679-ja\/gc-inlet-liner-selection-part-i-splitless-liner-selection-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/GNBL4679-JA\/gc-inlet-liner-selection-part-i-splitless-liner-selection-japan\" rel=\"noreferrer noopener\">GC\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u3073\u65b9 \u7b2cI\u90e8\uff1a\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u6700\u9069\u306a\u30e9\u30a4\u30ca\u30fc\u3092\u5fb9\u5e95\u89e3\u8aac<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar1991-ja\/japanese-how-to-choose-a-gc-inlet-liner\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/GNAR1991-JA\/japanese-how-to-choose-a-gc-inlet-liner\" rel=\"noreferrer noopener\">GC\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u3073\u65b9: \u6ce8\u5165\u65b9\u6cd5\u5225\u306e\u7c21\u5358\u306a\u30bb\u30ec\u30af\u30b7\u30e7\u30f3\u30ac\u30a4\u30c9<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnss2704-ja\/gnss2704\/gc-inlet-maintenance-resteks-quick-reference-guide\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/articles\/GNSS2704\/gc-inlet-maintenance-resteks-quick-reference-guide\/\">GC Inlet Maintenance Guide\uff08\u65e5\u672c\u8a9e\u6e96\u5099\u4e2d\uff09<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Restek\u306e\u304a\u3059\u3059\u3081\u30c4\u30fc\u30eb\u3068\u90e8\u54c1<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1210\" target=\"_blank\" rel=\"noopener\">Restek \u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/p\/28500\" target=\"_blank\" rel=\"noopener\">Restek \u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u79c1\u305f\u3061\u3068\u3064\u306a\u304c\u308a\u307e\u3057\u3087\u3046<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">YouTube:&nbsp;<a href=\"https:\/\/www.youtube.com\/user\/RestekCorp\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.youtube.com\/user\/RestekCorp<\/a>&nbsp;<br>LinkedIn:&nbsp;<a href=\"https:\/\/www.linkedin.com\/company\/restek-corporation\/\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.linkedin.com\/company\/restek-corporation\/<\/a><br>Facebook:&nbsp;<a href=\"https:\/\/www.facebook.com\/RestekCorporation\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.facebook.com\/RestekCorporation<\/a>&nbsp;<br>Twitter:&nbsp;<a href=\"https:\/\/www.twitter.com\/Restek\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.twitter.com\/Restek<\/a>&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306f\u5fae\u91cf\u5206\u6790\u3092\u5b9f\u884c\u3059\u308b\u305f\u3081\u306e\u512a\u308c\u305f\u624b\u6cd5\u3067\u3059\u3002\u305f\u3060\u3057\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u5206\u6790\u3092\u6700\u5927\u9650\u306b\u6d3b\u7528\u3059\u308b\u306b\u306f\u3001\u30b7\u30b9\u30c6\u30e0\u3092\u6700\u9069\u5316\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u3067\u306f\u3001\u6700\u826f\u306e\u7d50\u679c\u3092\u5f97\u308b\u306b\u306f\u3001\u4f55\u3092\u6700\u9069\u5316\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u306e\u3067\u3057\u3087\u3046\u304b\uff1f\u3053\u306eRestek Tip\u304c\u304a\u5f79\u306b\u7acb\u3064\u3053\u3068\u3092\u9858\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u3053\u3067\u306f\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3092\u6700\u9069\u5316\u3057\u3066\u3001\u8cea\u306e\u826f\u3044\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3092\u5b9f\u73fe\u3059\u308b\u65b9\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u307e\u305a\u306f\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u629e\u304b\u3089\u59cb\u3081\u307e\u3057\u3087\u3046\u3002\u9069\u5207\u306a\u30e9\u30a4\u30ca\u30fc\u3092\u9078\u629e\u3059\u308b\u3068\u3001\u5206\u6790\u7a2e\u306e\u56de\u53ce\u7387\u3068\u6ce8\u5165\u6bce\u306e\u518d\u73fe\u6027\u306e\u4e21\u65b9\u3092\u5927\u5e45\u306b\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u5206\u6790\u306e\u5834\u5408\u3001\u5747\u4e00\u306a\u6c17\u5316\u304c\u6700\u5927\u9650\u306b\u304a\u3053\u306a\u308f\u308c\u3001\u4e0d\u6d3b\u6027\u3067\u3001\u5e95\u304c\u5148\u7d30\u306b\u306a\u3063\u3066\u3044\u308b\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\u304c\u5fc5\u8981\u3067\u3059\u3002\u30a6\u30fc\u30eb\u5165\u308a\u306e\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\u3001\u307e\u305f\u306f\u30c0\u30d6\u30eb\u30c6\u30fc\u30d1\u30fc\u30b5\u30a4\u30af\u30ed\u30e9\u30a4\u30ca\u30fc\u304c\u6700\u9069\u3067\u3059\u3002\u4f59\u5206\u306a\u8868\u9762\u7a4d\u3092\u3082\u305f\u3089\u3059\u30a6\u30fc\u30eb\u3084\u30b9\u30af\u30ea\u30e5\u30fc\u72b6\u306e\u6e9d\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u6c17\u5316\u3057\u3001\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u3068\u6df7\u5408\u3059\u308b\u306e\u306b\u5f79\u7acb\u3061\u307e\u3059\u3002\u307e\u305f\u3001\u4e0d\u63ee\u767a\u6027\u7269\u8cea\u3092\u30c8\u30e9\u30c3\u30d7\u3057\u3001\u30ab\u30e9\u30e0\u3092\u4fdd\u8b77\u3059\u308b\u306e\u306b\u3082\u5f79\u7acb\u3061\u307e\u3059\u3002\u30e9\u30a4\u30ca\u30fc\u306e\u4e0d\u6d3b\u6027\u5316\u306f\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u3068\u3063\u3066\u91cd\u8981\u3067\u3059\u3002\u6ce8\u5165\u53e3\u3067\u306e\u6ede\u7559\u6642\u9593\u304c\u9577\u304f\u306a\u308b\u3068\u3001\u5206\u6790\u7a2e\u304c\u6d3b\u6027\u70b9\u3068\u76f8\u4e92\u4f5c\u7528\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u6d3b\u6027\u70b9\u306f\u3001\u30e9\u30a4\u30ca\u30fc\u3068\u6ce8\u5165\u53e3\u5185\u306b\u5b58\u5728\u3057\u307e\u3059\u3002\u5341\u5206\u306b\u4e0d\u6d3b\u6027\u51e6\u7406\u3055\u308c\u305f\u30e9\u30a4\u30ca\u30fc\u3092\u9078\u629e\u3059\u308b\u3068\u3001\u3053\u306e\u3088\u3046\u306a\u76f8\u4e92\u4f5c\u7528\u306b\u3088\u308b\u60aa\u5f71\u97ff\u304c\u8efd\u6e1b\u3055\u308c\u307e\u3059\u3002\u6700\u5f8c\u306b\u3001\u30e9\u30a4\u30ca\u30fc\u306e\u4e0b\u90e8\u306b\u3042\u308b\u30c6\u30fc\u30d1\u30fc\u30c7\u30b6\u30a4\u30f3\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u30ab\u30e9\u30e0\u306b\u5411\u3051\u308b\u306e\u306b\u5f79\u7acb\u3061\u3001\u6ce8\u5165\u53e3\u306e\u5e95\u90e8\u3068\u306e\u63a5\u89e6\u3092\u6e1b\u3089\u3057\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u63a5\u89e6\u306f\u5206\u6790\u7a2e\u306e\u5206\u89e3\u304c\u751f\u3058\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b21\u306b\u3001\u6ce8\u5165\u53e3\u6e29\u5ea6\u3092\u6700\u9069\u5316\u3057\u307e\u3059\u3002\u9069\u5207\u306a\u6c17\u5316\u3092\u9054\u6210\u3059\u308b\u306e\u306b\u5341\u5206\u306a\u307b\u3069\u9ad8\u3044\u6e29\u5ea6\u3067\u3001\u304b\u3064\u904e\u5ea6\u306e\u6d3b\u6027\u3092\u5f15\u304d\u8d77\u3053\u3055\u306a\u3044\u7a0b\u5ea6\u306b\u4f4e\u3044\u6e29\u5ea6\u304c\u5fc5\u8981\u3067\u3059\u3002250\u00b0C\u304c\u51fa\u767a\u70b9\u3068\u3057\u3066\u9069\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u5206\u6790\u3067\u5168\u4f53\u7684\u306b\u6700\u826f\u306e\u30d4\u30fc\u30af\u30ec\u30b9\u30dd\u30f3\u30b9\u3092\u5f97\u308b\u305f\u3081\u306b\u306f\u3001\u3053\u306e\u6e29\u5ea6\u3092\u8abf\u6574\u3059\u308b\u5fc5\u8981\u304c\u751f\u3058\u308b\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002\u3067\u306f\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u30db\u30fc\u30eb\u30c9\u30bf\u30a4\u30e0\u3092\u6700\u9069\u5316\u3059\u308b\u306b\u306f\u3069\u3046\u3059\u308c\u3070\u3088\u3044\u3067\u3057\u3087\u3046\u304b\u3002\u3055\u3066\u3001\u5341\u5206\u306a\u9577\u3055\u306e\u30db\u30fc\u30eb\u30c9\u30bf\u30a4\u30e0\u304c\u5fc5\u8981\u306a\u306e\u3067\u3059\u304c\u3001\u305d\u308c\u306f\u5b8c\u5168\u306a\u6c17\u5316\u3068\u5206\u6790\u7a2e\u306e\u30ab\u30e9\u30e0\u3078\u306e\u79fb\u52d5\u306e\u305f\u3081\u306e\u3082\u306e\u3067\u3059\u3002\u305f\u3060\u3057\u3001\u9577\u3059\u304e\u308b\u3068\u6eb6\u5a92\u306e\u30d4\u30fc\u30af\u30c6\u30fc\u30ea\u30f3\u30b0\u304c\u3072\u3069\u304f\u306a\u308a\u3001\u6eb6\u51fa\u306e\u65e9\u3044\u5206\u6790\u7a2e\u306e\u5e72\u6e09\u306b\u3064\u306a\u304c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u7d4c\u9a13\u5247\u3068\u3057\u3066\u3001\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u304c\u30e9\u30a4\u30ca\u30fc\u5bb9\u91cf\u306e1.5\u500d\u304b\u30892\u500d\u6d41\u308c\u308b\u3088\u3046\u306b\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002Restek\u306eEZGC Flow Calculator\u3067\u306f\u3001\u7406\u60f3\u7684\u306a\u30db\u30fc\u30eb\u30c9\u30bf\u30a4\u30e0\u7bc4\u56f2\u3092\u8a08\u7b97\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u305d\u3057\u3066\u6700\u5f8c\u306b\uff1a\u30aa\u30fc\u30d6\u30f3\u306e\u521d\u671f\u6e29\u5ea6\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u30e2\u30fc\u30c9\u3067\u306f\u6d41\u91cf\u304c\u9045\u3044\u305f\u3081\u3001\u30d0\u30f3\u30c9\u306e\u5e83\u304c\u308a\u304c\u751f\u3058\u308b\u3053\u3068\u304c\u3088\u304f\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u5206\u6790\u7a2e\u304c\u6ce8\u5165\u53e3\u5185\u3067\u62e1\u6563\u3059\u308b\u305f\u3081\u3067\u3059\u3002\u30ab\u30e9\u30e0\u306e\u5165\u53e3\u5074\u3067\u3053\u308c\u3089\u306e\u5206\u6790\u7a2e\u3092\u518d\u51dd\u96c6\u3059\u308b\u305f\u3081\u306b\u3001\u3088\u308a\u4f4e\u3044\u30aa\u30fc\u30d6\u30f3\u6e29\u5ea6\u304c\u5fc5\u8981\u3068\u306a\u308a\u307e\u3059\u3002\u30aa\u30fc\u30d6\u30f3\u521d\u671f\u6e29\u5ea6\u306e\u30db\u30fc\u30eb\u30c9\u6642\u9593\u306f\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u306e\u30db\u30fc\u30eb\u30c9\u6642\u9593\u3068\u4e00\u81f4\u3055\u305b\u307e\u3059\u3002\u4f7f\u7528\u3059\u308b\u6b63\u78ba\u306a\u6e29\u5ea6\u306f\u3001\u5206\u6790\u7a2e\u306e\u63ee\u767a\u6027\u306b\u3088\u3063\u3066\u7570\u306a\u308a\u307e\u3059\u3002\u305d\u308c\u3089\u304c\u6bd4\u8f03\u7684\u63ee\u767a\u6027\u304c\u9ad8\u3044\u5834\u5408\u3001\u30aa\u30fc\u30d6\u30f3\u521d\u671f\u6e29\u5ea6\u306f\u3001\u6eb6\u5a92\u306e\u6cb8\u70b9\u4ee5\u4e0b\u307e\u305f\u306f\u305d\u308c\u306b\u8fd1\u3044\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u308c\u3089\u304c\u6eb6\u5a92\u3088\u308a\u3082\u8457\u3057\u304f\u63ee\u767a\u6027\u304c\u4f4e\u3044\u5834\u5408\u306f\u3001\u3088\u308a\u9ad8\u3044\u30aa\u30fc\u30d6\u30f3\u521d\u671f\u6e29\u5ea6\u3092\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u3053\u308c\u3067\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3092\u6700\u9069\u5316\u3057\u3001\u5206\u6790\u3092\u958b\u59cb\u3059\u308b\u6e96\u5099\u304c\u3067\u304d\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3054\u4e0d\u660e\u306a\u70b9\u304c\u3054\u3056\u3044\u307e\u3057\u305f\u3089\u3001\u304a\u6c17\u8efd\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002\u30b3\u30e1\u30f3\u30c8\u3092\u3054\u5165\u529b\u3044\u305f\u3060\u304f\u304b\u3001restek.com\u306b\u30a2\u30af\u30bb\u30b9\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u3082\u3057\u3053\u306e\u3088\u3046\u306a\u30d3\u30c7\u30aa\u3092\u3082\u3063\u3068\u898b\u305f\u3044\u5834\u5408\u306f\u3001\u3044\u3044\u306d\u3068\u30c1\u30e3\u30f3\u30cd\u30eb\u767b\u9332\u3092\u304a\u9858\u3044\u3057\u307e\u3059\u3002\u6b21\u306eRestek Tip\u3067\u304a\u4f1a\u3044\u3067\u304d\u308b\u306e\u3092\u672c\u5f53\u306b\u697d\u3057\u307f\u306b\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306f\u3001\u5fae\u91cf\u5206\u6790\u306b\u512a\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3092\u6700\u5927\u9650\u306b\u751f\u304b\u3059\u305f\u3081\u306b\u306f\u3001\u30b7\u30b9\u30c6\u30e0\u3092\u6700\u9069\u5316\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u30e9\u30a4\u30ca\u30fc\u9078\u629e\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u30db\u30fc\u30eb\u30c9\u30bf\u30a4\u30e0\u3001\u30aa\u30fc\u30d6\u30f3\u521d\u671f\u6e29\u5ea6\u306a\u3069\u306b\u3064\u3044\u3066\u306fRestek Tip\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n","protected":false},"author":11,"featured_media":41387,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[774],"tags":[2800],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2566,2552],"resource-technique":[2340,2342],"ppma_author":[2814,414],"class_list":["post-42562","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-ja","tag-topaz-liners","product-library-inlet-supplies-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja","resource-technique-injection-techniques-ja"],"acf":[],"taxonomy_info":{"category":[{"value":774,"label":"\u52d5\u753b"}],"post_tag":[{"value":2800,"label":"Topaz Liners"}],"product-library":[{"value":2566,"label":"GC \u6ce8\u5165\u53e3\u95a2\u9023\u90e8\u54c1"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2342,"label":"\u6ce8\u5165\u65b9\u6cd5"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3699-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":774,"name":"\u52d5\u753b","slug":"videos-ja","term_group":0,"term_taxonomy_id":774,"taxonomy":"category","description":"","parent":0,"count":139,"filter":"raw","cat_ID":774,"category_count":139,"category_description":"","cat_name":"\u52d5\u753b","category_nicename":"videos-ja","category_parent":0}],"tag_info":[{"term_id":2800,"name":"Topaz Liners","slug":"topaz-liners","term_group":0,"term_taxonomy_id":2800,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw"}],"authors":[{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""},{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42562","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=42562"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42562\/revisions"}],"predecessor-version":[{"id":81035,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42562\/revisions\/81035"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/41387"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=42562"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=42562"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=42562"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=42562"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=42562"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=42562"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=42562"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=42562"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=42562"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}