{"id":42567,"date":"2022-07-11T04:00:00","date_gmt":"2022-07-11T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/what-do-you-do-with-a-new-lc-column\/"},"modified":"2025-11-26T20:16:49","modified_gmt":"2025-11-26T20:16:49","slug":"what-do-you-do-with-a-new-lc-column","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/videos\/gnav3838\/what-do-you-do-with-a-new-lc-column","title":{"rendered":"What Do You Do with a New LC Column?"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"What Do You Do with a New LC Column?\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/KDP-bi87iTw?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Description<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Before you can use a new LC column to perform analyses, there are a few important steps you need to do to prepare it for its new life in your lab.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In this Restek Tip, we show you how to set up your new LC column. We cover certificate of analyses (CofAs), discuss the different column end-fittings you can use, share how to condition your column for your mobile phase, and finally, we\u2019ll look at how to select an appropriate flow rate for your column. Let\u2019s get started!<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Additional Resources<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"documentation-search\">Restek Documentation Search<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/articles\/solvent-miscibility-and-solubility\" target=\"_blank\" rel=\"noopener\">Solvent Miscibility and Solubility Chart<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/articles\/restek-liquid-chromatography-lc-columns-usage-care\/\" target=\"_blank\" rel=\"noopener\">Restek LC Column Use and Care Instruction Sheet<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/articles\/frequently-asked-questions-hplc-and-uhplc\" target=\"_blank\" rel=\"noopener\">HPLC and UHPLC FAQ<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Restek Recommended Tools &amp; Parts<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/p\/25937\" target=\"_blank\" rel=\"noopener\">EXP Reusable Fittings<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1119\" target=\"_blank\" rel=\"noopener\">Restek\u2019s HPLC &amp; UHPLC Columns<\/a><\/li>\n\n\n\n<li>Restek\u2019s LC Accessories\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1122\" target=\"_blank\" rel=\"noopener\">LC-MS Supplies<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1118\" target=\"_blank\" rel=\"noopener\">LC Autosampler Supplies<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1123\" target=\"_blank\" rel=\"noopener\">Mobile Phase Management<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1120\" target=\"_blank\" rel=\"noopener\">LC Detector Supplies<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1121\" target=\"_blank\" rel=\"noopener\">LC Tubing &amp; Fittings<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1124\" target=\"_blank\" rel=\"noopener\">LC Pump Supplies<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1125\" target=\"_blank\" rel=\"noopener\">Tools &amp; Organization<\/a><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transcript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Congratulations on your new column! You\u2019ll soon be on your way to performing some high-quality chromatography. But before you can use your column to perform analyses, there are a few steps you need to do to prepare it for its new life in your lab.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In this Restek Tip, we\u2019re going to show you how to set up your new LC column. We\u2019re going to start by showing you where to find your certificate of analysis and review the information it contains. We\u2019ll discuss the different column end-fittings you can use and then connect the column to your instrument. Next, we\u2019ll look at how to condition your column for your mobile phase, and finally, we\u2019ll look at how to select an appropriate flow rate for your column.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Let\u2019s get started.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Certificate of Analysis<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Every LC column that Restek makes is individually tested to ensure superior performance. A certificate of analysis is generated for each column and includes the performance report with the conditions that were used. It also lists the storage solvent that\u2019s currently within the column, which we will need to reference later. You can download your certificate of analysis from the Restek website at any time from www.restek.com\/documentation which can be helpful to have if troubleshooting is ever required.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Connecting Your Column<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Let\u2019s look at your new column. All Restek LC columns are made from 316 stainless-steel, meaning they are corrosion resistant. If your current system is set up with a Restek column, the end-fittings of your new column will be compatible with your current fittings. However, if your system is set up with another manufacturer\u2019s column, you may need new fittings. If your current fittings are permanently swaged on, either cut off the old fittings, or replace the tubing and fittings entirely. While you may already have PEEK or stainless-steel fittings installed on your system, it\u2019s important to check if these are suitable for your analysis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">PEEK fittings are convenient for low pressure\u2014less than 4000 psi or 275 bar\u2014but are likely to leak at higher pressures. If you have moderate to high flow rates, a column with smaller particle sizes, or a narrower column, your backpressure is likely to exceed 4000 psi. Therefore, we do not recommend their use under these conditions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Stainless-steel fittings and connectors are good choices for higher pressures. However, one major drawback to stainless-steel fittings is that they require wrenches for column installation, and tubing depth can only be set once as the ferrules \u201cbite\u201d into the tubing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">EXP fittings are another option for connecting your new column to your instrument. EXP fittings are a hybrid titanium \/PEEK solution that allows for hand-tightened connections that are effective to 8700 psi or 600 bar\u2014and can exceed 20,000 psi or 1380 bar with wrenches.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">They also have an adjustable fitting depth, so you can repeatedly make connections with columns of differing seat depth without changing the fitting or tubing. EXP fittings provide most of the high-pressure capabilities inherent with stainless-steel fittings while providing many of the conveniences offered by PEEK fittings, making them an easy, go-to choice.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Connecting your new column is relatively straightforward, but there are some considerations to keep in mind. Make sure your column connectors are properly seated before tightening. Loose connectors can introduce dead volume, resulting in poor efficiency and band broadening. It can also make it harder to remove your column in the future. Finally, double-check that the arrow direction on your column\u2019s label matches the direction of your solvent flow. Failing to do so can shorten your column\u2019s lifetime and result in poor efficiency.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Conditioning<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Now that your column is installed, it\u2019s time to check if the mobile phase you\u2019re using is compatible with the storage solvent already in the column. Each column is shipped containing a storage solvent that keeps the column stable for long-term storage. The storage solvent is listed on your certificate of analysis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If the solvent you wish to use is immiscible with the storage solvent\u2014here\u2019s a chart from restek.com for more information\u2014then you will need to flush the column with an intermediate solvent that is compatible with both the storage solvent and your mobile phase.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If you plan to use a buffer, make sure it won\u2019t precipitate out of your mobile phase or in the storage solvent. Most storage solvents are greater than 50% organic, which can cause buffers to precipitate and plug the column. This can increase backpressure, so make sure you have enough aqueous mobile phase to guarantee your buffer remains in solution.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Flow Rates<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Your next task is to select an appropriate flow rate for your column. Optimal flow rates are determined by the column\u2019s inner diameter and the particle size of your stationary phase, as shown in this table.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When starting the flow through the column, we recommend you direct the flow into a beaker for 10-15 minutes. Start with a slow flow rate and gradually increase to the optimum flow rate during this time. Abrupt changes in pressure can cause leaks or even damage the column\u2019s particle bed, resulting in poor peak shape or even split peaks.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Once the column has been adequately flushed at the desired flow rate, stop the mobile phase flow.&nbsp; Now you can connect the column to the detector.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">And there you go! That\u2019s how to prepare your new LC column. If you have any questions, contact us at www.restek.com\/contact-us<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Thank you for joining us for this Restek Tip!<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Before you can use a new LC column to perform analyses, there are a few important steps you need to do to prepare it for its new life in your lab. In this Restek Tip video, we show you how to set up your new LC column. We cover certificate of analyses (CofAs), discuss the different column end-fittings you can use, share how to condition your column for your mobile phase, and finally, we\u2019ll look at how to select an appropriate flow rate for your column.<\/p>\n","protected":false},"author":11,"featured_media":41394,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[8],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[563],"product-library":[2571,2576,2553],"resource-technique":[2343],"ppma_author":[2814],"class_list":["post-42567","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos","resource-type-column-installation-and-care","product-library-lc-columns-ja","product-library-lc-tubing-fittings-ja","product-library-liquid-chromatography-products-ja","resource-technique-liquid-chromatography-ja"],"acf":[],"taxonomy_info":{"category":[{"value":8,"label":"Videos"}],"resource-type":[{"value":563,"label":"Column Installation and Care"}],"product-library":[{"value":2571,"label":"LC \u30ab\u30e9\u30e0"},{"value":2576,"label":"LC \u914d\u7ba1\uff5c\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0"},{"value":2553,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3838-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"Videos","slug":"videos","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":139,"filter":"raw","cat_ID":8,"category_count":139,"category_description":"","cat_name":"Videos","category_nicename":"videos","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42567","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=42567"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42567\/revisions"}],"predecessor-version":[{"id":64137,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42567\/revisions\/64137"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/41394"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=42567"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=42567"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=42567"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=42567"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=42567"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=42567"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=42567"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=42567"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=42567"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}