{"id":42617,"date":"2020-01-22T05:00:00","date_gmt":"2020-01-22T05:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-correctly-using-a-press-tight-connector\/"},"modified":"2025-11-25T23:28:58","modified_gmt":"2025-11-25T23:28:58","slug":"japanese-correctly-using-a-press-tight-connector","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav4909-ja\/japanese-correctly-using-a-press-tight-connector","title":{"rendered":"Press-Tight\u30b3\u30cd\u30af\u30bf\u306e\u6b63\u3057\u3044\u4f7f\u3044\u65b9"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Correctly Using a Press-Tight Connector\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/VNlbbfKmhS8?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"512\" height=\"373\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1.png\" alt=\"\" class=\"wp-image-29853\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1.png 512w, https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1-300x219.png 300w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"447\" height=\"528\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12.png\" alt=\"\" class=\"wp-image-29859\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12.png 447w, https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12-254x300.png 254w\" sizes=\"auto, (max-width: 447px) 100vw, 447px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">YouTube\u753b\u9762\u53f3\u4e0b\u306b\u3042\u308b\u8a2d\u5b9a\u30dc\u30bf\u30f3\u2699\u304b\u3089<strong>Subtitles\/CC<\/strong>\u3092\u9078\u3073\u3001<strong>Japanese<\/strong>\u306b\u30c1\u30a7\u30c3\u30af\u3092\u5165\u308c\u308b\u3068\u65e5\u672c\u8a9e\u5b57\u5e55\u3042\u308a\u3067\u52d5\u753b\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u6982\u8981<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u3092\u5206\u96e2\u30ab\u30e9\u30e0\u306b\u63a5\u7d9a\u3057\u305f\u308a\u30012\u3064\u306e\u30ab\u30e9\u30e0\u3092\u63a5\u7d9a\u3057\u305f\u308a\u3001\u58ca\u308c\u305f\u30ab\u30e9\u30e0\u3092\u4fee\u7406\u3057\u305f\u308a\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u5834\u5408\u3001\u30af\u30ea\u30fc\u30f3\u3067\u78ba\u5b9f\u306a\u63a5\u7d9a\u306f\u3068\u3066\u3082\u91cd\u8981\u3067\u3059\u3002&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306eRestek Tip\u3067\u306f\u3001Press-Tight\u30b3\u30cd\u30af\u30bf\u306e\u4f7f\u7528\u65b9\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002 \u30b3\u30cd\u30af\u30bf\u306b\u306f\u69d8\u3005\u306a\u30bf\u30a4\u30d7\u304c\u3042\u308a\u30012\u3064\u306e\u30ab\u30e9\u30e0\u3092\u63a5\u7d9a\u3059\u308b\u3053\u3068\u304b\u3089\u3001\u58ca\u308c\u305f\u30ab\u30e9\u30e0\u306e\u4fee\u5fa9\u307e\u3067\u7528\u9014\u3082\u3044\u308d\u3044\u308d\u3067\u3059\u3002\u305d\u308c\u3067\u306f\u30ab\u30e9\u30e0\u306e\u63a5\u7d9a\u3092\u3057\u3066\u307f\u307e\u3057\u3087\u3046\uff01&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u305d\u306e\u4ed6\u306e\u30ea\u30bd\u30fc\u30b9<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/202-04-001_JP.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Press-Tight Connector Instruction Sheet\uff08\u82f1\u6587\u306e\u307f\uff09<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Restek\u63a8\u5968\u30c4\u30fc\u30eb\u3068\u90e8\u54c1<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1571\" target=\"_blank\" rel=\"noreferrer noopener\">Universal Press-Tight Connectors<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/20445\" target=\"_blank\" rel=\"noreferrer noopener\">Polyimide Resin<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Restek\u306b\u306f\u3053\u3061\u3089\u304b\u3089\u3082\u30a2\u30af\u30bb\u30b9\u3067\u304d\u307e\u3059<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">YouTube:&nbsp;<a href=\"https:\/\/www.youtube.com\/user\/RestekCorp\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.youtube.com\/user\/RestekCorp<\/a>&nbsp;<br>LinkedIn:&nbsp;<a href=\"https:\/\/www.linkedin.com\/company\/restek-corporation\/\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.linkedin.com\/company\/restek-corporation\/<\/a><br>Facebook:&nbsp;<a href=\"https:\/\/www.facebook.com\/RestekCorporation\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.facebook.com\/RestekCorporation<\/a>&nbsp;<br>Twitter:&nbsp;<a href=\"https:\/\/www.twitter.com\/Restek\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.twitter.com\/Restek<\/a>&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u3092\u5206\u96e2\u30ab\u30e9\u30e0\u306b\u63a5\u7d9a\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u5834\u5408\u3084\u30012\u3064\u306e\u30ab\u30e9\u30e0\u3092\u63a5\u7d9a\u3059\u308b\u304b\u3001\u58ca\u308c\u305f\u30ab\u30e9\u30e0\u3092\u4fee\u5fa9\u3059\u308b\u969b\u3001\u30af\u30ea\u30fc\u30f3\u3067\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u63a5\u7d9a\u3092\u78ba\u7acb\u3059\u308b\u3053\u3068\u304c\u3044\u304b\u306b\u91cd\u8981\u304b\u3092\u3054\u5b58\u77e5\u3067\u3057\u3087\u3046\u3002\u3053\u306eRestek Tip\u3067\u306f\u3001Press-Tight\u30b3\u30cd\u30af\u30bf\u3092\u4f7f\u7528\u3057\u3066\u63a5\u7d9a\u3092\u884c\u3046\u65b9\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305a\u3001GC\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306e\u7aef\u3092\u30ab\u30c3\u30c8\u3057\u3001\u304d\u308c\u3044\u306a\u6b63\u65b9\u5f62\u306e\u30a8\u30c3\u30b8\u3092\u4f5c\u6210\u3057\u307e\u3059\u3002\u30ab\u30c3\u30c8\u304c\u5b8c\u4e86\u3057\u305f\u3089\u3001\u7cf8\u304f\u305a\u306e\u51fa\u306a\u3044\u5e03\u3067\u30ab\u30e9\u30e0\u306e\u7aef\u3092\u304d\u308c\u3044\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u3053\u306e\u6642\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\u3084\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u306a\u3069\u306e\u6eb6\u5a92\u3067\u6e7f\u3089\u305b\u3001\u307b\u3053\u308a\u3084\u304b\u3051\u3089\u3092\u53d6\u308a\u9664\u304d\u307e\u3059\u3002\u3055\u3066\u3001\u7247\u624b\u3067Press-Tight\u30b3\u30cd\u30af\u30bf\u3092\u4fdd\u6301\u3057\u306a\u304c\u3089\u3001\u30ab\u30e9\u30e0\u306e\u7aef\u304c\u5468\u56f2\u3050\u308b\u308a\u3068\u5168\u4f53\u7684\u306b\u3057\u3063\u304b\u308a\u3068\u56fa\u5b9a\u3055\u308c\u308b\u307e\u3067\u3001\u30ab\u30e9\u30e0\u306e\u7aef\u3092\u30b3\u30ec\u30af\u30bf\u306b\u3086\u3063\u304f\u308a\u3068\u633f\u5165\u3057\u307e\u3059\u3002\u30ab\u30e9\u30e0\u306e\u7aef\u304c\u5727\u7e2e\u3055\u308c\u308b\u5207\u308c\u76ee\u306e\u306a\u3044\u8336\u8272\u306e\u30ea\u30f3\u30b0\u304c\u3067\u304d\u307e\u3059\u3002\u3053\u308c\u304c\u30b3\u30cd\u30af\u30bf\u5185\u90e8\u306e\u9069\u5207\u306a\u63a5\u7d9a\u3092\u793a\u3057\u307e\u3059\u3002\u5f37\u304f\u62bc\u3057\u3059\u304e\u308b\u3068\u3001\u30ab\u30e9\u30e0\u306e\u7aef\u304c\u3064\u3076\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u306e\u3067\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u305d\u3057\u3066\u4eca\u5ea6\u306f\u3001\u3082\u3046\u4e00\u672c\u306e\u30ab\u30e9\u30e0\u3092\u30b3\u30cd\u30af\u30bf\u306b\u633f\u5165\u3059\u308b\u30d7\u30ed\u30bb\u30b9\u3092\u7e70\u308a\u8fd4\u3059\u3060\u3051\u3067\u3059\u3002\u8010\u4e45\u6027\u306e\u3042\u308b\u63a5\u7d9a\u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u306b\u3001\u3054\u304f\u5c11\u91cf\u306e\u30dd\u30ea\u30a4\u30df\u30c9\u6a39\u8102\u3092\u5857\u5e03\u3059\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002Press-Tight\u30b3\u30cd\u30af\u30bf\u306e\u958b\u53e3\u90e8\u4ed8\u8fd1\u306e\u30ab\u30e9\u30e0\u30c1\u30e5\u30fc\u30d6\u306e\u9014\u4e2d\u306b\u5857\u5e03\u3057\u307e\u3059\u300230\u5206\u9593\u7a7a\u6c17\u4e7e\u71e5\u3055\u305b\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u308c\u3067\u3001\u30ab\u30e9\u30e0\u3092\u53d6\u308a\u4ed8\u3051\u308b\u6e96\u5099\u304c\u3067\u304d\u307e\u3057\u305f\u3002\u30ab\u30e9\u30e0\u3092\u53d6\u308a\u4ed8\u3051\u3001\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u3092\u30aa\u30f3\u306b\u3057\u305f\u5f8c\u3001\u5b9f\u969b\u306b\u4f7f\u7528\u3059\u308b\u524d\u306b\u5b9f\u884c\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u3044\u304f\u3064\u304b\u306e\u91cd\u8981\u306a\u624b\u9806\u304c\u3042\u308a\u307e\u3059\u3002\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3092\u4f7f\u7528\u3057\u3066\u3001\u30ab\u30e9\u30e0\u306b\u6e29\u5ea6\u3092\u304b\u3051\u308b\u524d\u5f8c\u3067\u63a5\u7d9a\u90e8\u306e\u30ea\u30fc\u30af\u3092\u30c1\u30a7\u30c3\u30af\u3057\u307e\u3059\u3002\u4fdd\u6301\u3055\u308c\u306a\u3044\u5316\u5408\u7269\u3092\u6ce8\u5165\u3057\u3066\u63a5\u7d9a\u306e\u5b8c\u5168\u6027\u3092\u30c6\u30b9\u30c8\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u305d\u3057\u3066\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u6ce8\u610f\u6df1\u304f\u78ba\u8a8d\u3057\u307e\u3057\u3087\u3046\u3002\u5bfe\u7167\u7684\u306a\u30d4\u30fc\u30af\u306f\u3001\u9069\u5207\u306a\u63a5\u7d9a\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u5ea6\u52a0\u71b1\u3059\u308b\u3068\u3001\u30b3\u30cd\u30af\u30bf\u306f\u518d\u5229\u7528\u3067\u304d\u306a\u3044\u3053\u3068\u306b\u3054\u6ce8\u610f\u304f\u3060\u3055\u3044\u3002\u30b3\u30cd\u30af\u30bf\u5185\u90e8\u3067\u786c\u5316\u3057\u305f\u30dd\u30ea\u30a4\u30df\u30c9\u6b8b\u7559\u7269\u304c\u30b7\u30fc\u30eb\u3092\u59a8\u3052\u308b\u304b\u3089\u3067\u3059\u3002\u30dd\u30ea\u30a4\u30df\u30c9\u6a39\u8102\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u3001\u6f0f\u308c\u306e\u306a\u3044\u63a5\u7d9a\u3092\u78ba\u7acb\u3057\u305f\u3089\u3001GC\u30aa\u30fc\u30d6\u30f3\u3067\u30ab\u30e9\u30e0\u3092\u52a0\u71b1\u3057\u3066\u6a39\u8102\u3092\u786c\u5316\u3055\u305b\u307e\u3059\u3002\u305d\u308c\u306b\u306f\u3001\u30ac\u30b9\u3092\u6d41\u3057\u305f\u307e\u307e\u3001\u3053\u306e\u30d7\u30ed\u30b0\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"387\" height=\"205\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/program-for-correctly-using-a-Press-Tight-connector.png\" alt=\"\" class=\"wp-image-28599\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/program-for-correctly-using-a-Press-Tight-connector.png 387w, https:\/\/discover.restek.com\/wp-content\/uploads\/program-for-correctly-using-a-Press-Tight-connector-300x159.png 300w\" sizes=\"auto, (max-width: 387px) 100vw, 387px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u30dd\u30ea\u30a4\u30df\u30c9\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u30c1\u30e5\u30fc\u30d6\u3092\u52a0\u71b1\u3059\u308b\u5834\u5408\u3001350\u2103\u4ee5\u4e0a\u3067\u9577\u6642\u9593\u52a0\u71b1\u3059\u308b\u3068\u3001\u30dd\u30ea\u30a4\u30df\u30c9\u304c\u4e7e\u71e5\u3057\u3066\u3001\u30b7\u30fc\u30eb\u6027\u304c\u60aa\u304f\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u3053\u3068\u306b\u3054\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u63a5\u7d9a\u3092\u5b9a\u671f\u7684\u306b\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u3057\u3066\u3001\u30b7\u30fc\u30eb\u306e\u5b8c\u5168\u6027\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u4ee5\u4e0a\u3067\u3059\uff01\u5b8c\u4e86\u3067\u3059\uff012\u3064\u306e\u30ab\u30e9\u30e0\u306e\u9593\u306b\u30b7\u30fc\u30eb\u3092\u4f5c\u6210\u3059\u308b\u305f\u3081\u306b\u5fc5\u8981\u306a\u306e\u306f\u3053\u308c\u3060\u3051\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u30b3\u30f3\u30c6\u30f3\u30c4\u304c\u6c17\u306b\u5165\u3063\u305f\u3089\u3001\u3054\u767b\u9332\u304f\u3060\u3055\u3044\u3002\u3053\u306eRestek Tip\u306b\u3054\u53c2\u52a0\u3044\u305f\u3060\u304d\u3042\u308a\u304c\u3068\u3046\u3054\u3056\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>2\u672c\u306e\u30ab\u30e9\u30e0\u3092\u63a5\u7d9a\u3057\u305f\u308a\u3001\u6298\u308c\u305f\u30ab\u30e9\u30e0\u3092\u76f4\u3057\u305f\u308a\u3059\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u3059\u304b\uff1fPress-Tight\u30b3\u30cd\u30af\u30bf\u306e\u4f7f\u3044\u65b9\u306f\u3001\u3053\u3061\u3089\u306eRestek Tip\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n","protected":false},"author":11,"featured_media":41519,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[774],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2385,2565,2552],"resource-technique":[2340],"ppma_author":[414],"class_list":["post-42617","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-ja","product-library-ferrules-fittings-connectors","product-library-ferrules-fittings-connectors-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":774,"label":"\u52d5\u753b"}],"product-library":[{"value":2385,"label":"Ferrules, Fittings, Connectors"},{"value":2565,"label":"GC \u30d5\u30a7\u30e9\u30eb\uff5c\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\uff5c\u30b3\u30cd\u30af\u30bf"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV4909-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":774,"name":"\u52d5\u753b","slug":"videos-ja","term_group":0,"term_taxonomy_id":774,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":774,"category_count":138,"category_description":"","cat_name":"\u52d5\u753b","category_nicename":"videos-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42617","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=42617"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42617\/revisions"}],"predecessor-version":[{"id":69233,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42617\/revisions\/69233"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/41519"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=42617"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=42617"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=42617"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=42617"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=42617"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=42617"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=42617"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=42617"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=42617"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}