{"id":42956,"date":"2025-07-30T17:39:38","date_gmt":"2025-07-30T17:39:38","guid":{"rendered":"https:\/\/live-discover-restek.pantheonsite.io\/?p=42956"},"modified":"2025-12-09T15:55:54","modified_gmt":"2025-12-09T15:55:54","slug":"what-are-the-operating-temperatures-for-treated-surfaces-jp","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq-ja\/gnot5194-ja\/what-are-the-operating-temperatures-for-treated-surfaces-jp","title":{"rendered":"\u51e6\u7406\u3055\u308c\u305f\u8868\u9762\u306e\u4f7f\u7528\u6e29\u5ea6\u306f\u4f55\u2103\u3067\u3059\u304b\uff1f"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u901a\u5e38\u3001\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u306f\u57fa\u6750\uff08\u30ac\u30e9\u30b9\u3001\u30b9\u30c6\u30f3\u30ec\u30b9\u92fc\u306a\u3069\uff09\u306b\u3088\u3063\u3066\u6c7a\u307e\u308a\u307e\u3059\u3002\u4e00\u822c\u7684\u306b\u3001\u4f7f\u7528\u6e29\u5ea6\u306f\u8868I\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u3082\u306e\u3092\u8d85\u3048\u306a\u3044\u3088\u3046\u306b\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u7279\u5b9a\u306e\u6761\u4ef6\u4e0b\u306b\u9650\u308a\u3001Sulfinert\u3084Siltek\u51e6\u7406\u3055\u308c\u305f\u8868\u9762\u306e\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u306e450\u00b0C\u3092\u8d85\u3048\u305f\u308a\u3001Silcosteel\u3084Silcosteel-CR\u51e6\u7406\u3055\u308c\u305f\u8868\u9762\u306e\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u306e600\u00b0C\u3092\u8d85\u3048\u305f\u308a\u3059\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002Silcosteel\u307e\u305f\u306fSilcosteel-CR\u51e6\u7406\u3092\u65bd\u3059\u524d\u306b\u90e8\u54c1\u3092\u71b1\u51e6\u7406\u3059\u308b\u3068\u3001\u8010\u71b1\u6e29\u5ea6\u304c\u62e1\u5f35\u3055\u308c\u307e\u3059\u3002\u8a73\u7d30\u306a\u60c5\u5831\u306b\u3064\u3044\u3066\u306f\u3001\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8\u307e\u3067\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002\u2192 \u554f\u3044\u5408\u308f\u305b\u30d5\u30a9\u30fc\u30e0\uff08\u307e\u305f\u306f\u96fb\u8a71\u756a\u53f7\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8868I:\u00a0<\/strong>\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u306f\u4e0d\u6d3b\u6027\u306a\u6761\u4ef6\u306b\u304a\u3044\u3066\u4ee5\u4e0b\u306e\u6e29\u5ea6\u3067\u5b89\u5b9a\u3067\u3059<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Sulfinert<\/td><td>450\u00b0C<\/td><\/tr><tr><td>Siltek<\/td><td>450\u00b0C<\/td><\/tr><tr><td>Silcosteel<\/td><td>600\u00b0C<\/td><\/tr><tr><td>Silcosteel-CR<\/td><td>600\u00b0C<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u901a\u5e38\u3001\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u306f\u57fa\u6750\uff08\u30ac\u30e9\u30b9\u3001\u30b9\u30c6\u30f3\u30ec\u30b9\u92fc\u306a\u3069\uff09\u306b\u3088\u3063\u3066\u6c7a\u307e\u308a\u307e\u3059\u3002\u4e00\u822c\u7684\u306b\u3001\u4f7f\u7528\u6e29\u5ea6\u306f\u8868I\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u3082\u306e\u3092\u8d85\u3048\u306a\u3044\u3088\u3046\u306b\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u7279\u5b9a\u306e\u6761\u4ef6\u4e0b\u306b\u9650\u308a\u3001Sulfinert\u3084Siltek\u51e6\u7406\u3055\u308c\u305f\u8868\u9762\u306e\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u306e450\u00b0C\u3092\u8d85\u3048\u305f\u308a\u3001Silcosteel\u3084Silcosteel-CR\u51e6\u7406\u3055\u308c\u305f\u8868\u9762\u306e\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u306e600\u00b0C\u3092\u8d85\u3048\u305f\u308a\u3059\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002Silcosteel\u307e\u305f\u306fSilcosteel-CR\u51e6\u7406\u3092\u65bd\u3059\u524d\u306b\u90e8\u54c1\u3092\u71b1\u51e6\u7406\u3059\u308b\u3068\u3001\u8010\u71b1\u6e29\u5ea6\u304c\u62e1\u5f35\u3055\u308c\u307e\u3059\u3002\u8a73\u7d30\u306a\u60c5\u5831\u306b\u3064\u3044\u3066\u306f\u3001\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8\u307e\u3067\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002\u2192 \u554f\u3044\u5408\u308f\u305b\u30d5\u30a9\u30fc\u30e0\uff08\u307e\u305f\u306f\u96fb\u8a71\u756a\u53f7\uff09 \u8868I:\u00a0\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u306f\u4e0d\u6d3b\u6027\u306a\u6761\u4ef6\u306b\u304a\u3044\u3066\u4ee5\u4e0b\u306e\u6e29\u5ea6\u3067\u5b89\u5b9a\u3067\u3059 Sulfinert 450\u00b0C Siltek 450\u00b0C Silcosteel 600\u00b0C Silcosteel-CR 600\u00b0C<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[804],"tags":[2723],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[2814],"class_list":["post-42956","post","type-post","status-publish","format-standard","hentry","category-faq-ja","tag-frequently-asked-questions-surface-treatments-japan"],"acf":[],"taxonomy_info":{"category":[{"value":804,"label":"FAQ"}],"post_tag":[{"value":2723,"label":"\u3088\u304f\u3042\u308b\u8cea\u554f\uff08FAQ\uff09\uff1a\u8868\u9762\u51e6\u7406\u306b\u3064\u3044\u3066"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":804,"name":"FAQ","slug":"faq-ja","term_group":0,"term_taxonomy_id":804,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":804,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq-ja","category_parent":0}],"tag_info":[{"term_id":2723,"name":"\u3088\u304f\u3042\u308b\u8cea\u554f\uff08FAQ\uff09\uff1a\u8868\u9762\u51e6\u7406\u306b\u3064\u3044\u3066","slug":"frequently-asked-questions-surface-treatments-japan","term_group":0,"term_taxonomy_id":2723,"taxonomy":"post_tag","description":"","parent":0,"count":32,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42956","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=42956"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42956\/revisions"}],"predecessor-version":[{"id":72667,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/42956\/revisions\/72667"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=42956"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=42956"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=42956"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=42956"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=42956"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=42956"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=42956"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=42956"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=42956"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}