{"id":43227,"date":"2025-07-30T18:05:53","date_gmt":"2025-07-30T18:05:53","guid":{"rendered":"https:\/\/live-discover-restek.pantheonsite.io\/?p=43227"},"modified":"2025-12-09T15:45:00","modified_gmt":"2025-12-09T15:45:00","slug":"why-do-silcosteel-treated-pieces-have-different-colors-jp","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq-ja\/gnot5208-ja\/why-do-silcosteel-treated-pieces-have-different-colors-jp","title":{"rendered":"Silcosteel \u51e6\u7406\u3055\u308c\u305f\u90e8\u54c1\u306e\u8272\u304c\u7570\u306a\u308b\u306e\u306f\u306a\u305c\u3067\u3059\u304b?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Silcosteel\u3067\u51e6\u7406\u3055\u308c\u305f\u90e8\u54c1\u3067\u89b3\u5bdf\u3055\u308c\u308b\u7570\u306a\u308b\u8272\u306f\u3001\u5c64\u306e\u539a\u3055\u306e\u9055\u3044\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u9752\u8272\u306f300\u301c450\u00c5\u306e\u5c64\u306b\u5bfe\u5fdc\u3057\u3001\u8679\u8272\u306f\u5c11\u306a\u304f\u3068\u30821200\u00c5\u306e\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5c64\u306e\u539a\u3055\u306b\u95a2\u9023\u3059\u308b\u8272\u306f\u6b21\u306e\u3068\u304a\u308a\u3067\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-GNOT3398-02-1024x369.jpg\" alt=\"a blue and purple gradient scale showing colors associated with thickness of treatments\" class=\"wp-image-2882\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Silcosteel-CR\u30d7\u30ed\u30bb\u30b9\u3067\u4f7f\u7528\u3055\u308c\u308b\u539a\u3044\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u5c64\u306f\u30015\u00b5m\u304b\u308920\u00b5m\u306e\u6df1\u3055\u304c\u3042\u308a\u3001\u5916\u89b3\u306f\u30b7\u30eb\u30d0\u30fc\/\u30e1\u30bf\u30ea\u30c3\u30af\u30b0\u30ec\u30fc\u3067\u3059\u3002\u4ee5\u4e0b\u306e\u5199\u771f\u306f\u3001Sulfinert\uff08\u5de6\uff09\u304a\u3088\u3073Silcosteel-CR\uff08\u53f3\uff09\u306e\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u5c64\u306b\u3088\u3063\u3066\u751f\u3058\u308b\u8272\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-GNOT3398-03-1024x468.jpg\" alt=\"a close up of Sulfinert and Silcosteel-CR depositions on stainless steel\" class=\"wp-image-2876\" title=\"-\"><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Silcosteel\u3067\u51e6\u7406\u3055\u308c\u305f\u90e8\u54c1\u3067\u89b3\u5bdf\u3055\u308c\u308b\u7570\u306a\u308b\u8272\u306f\u3001\u5c64\u306e\u539a\u3055\u306e\u9055\u3044\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u9752\u8272\u306f300\u301c450\u00c5\u306e\u5c64\u306b\u5bfe\u5fdc\u3057\u3001\u8679\u8272\u306f\u5c11\u306a\u304f\u3068\u30821200\u00c5\u306e\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u3092\u793a\u3057\u307e\u3059\u3002 \u5c64\u306e\u539a\u3055\u306b\u95a2\u9023\u3059\u308b\u8272\u306f\u6b21\u306e\u3068\u304a\u308a\u3067\u3059\u3002 Silcosteel-CR\u30d7\u30ed\u30bb\u30b9\u3067\u4f7f\u7528\u3055\u308c\u308b\u539a\u3044\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u5c64\u306f\u30015\u00b5m\u304b\u308920\u00b5m\u306e\u6df1\u3055\u304c\u3042\u308a\u3001\u5916\u89b3\u306f\u30b7\u30eb\u30d0\u30fc\/\u30e1\u30bf\u30ea\u30c3\u30af\u30b0\u30ec\u30fc\u3067\u3059\u3002\u4ee5\u4e0b\u306e\u5199\u771f\u306f\u3001Sulfinert\uff08\u5de6\uff09\u304a\u3088\u3073Silcosteel-CR\uff08\u53f3\uff09\u306e\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u5c64\u306b\u3088\u3063\u3066\u751f\u3058\u308b\u8272\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[804],"tags":[2723],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[2814],"class_list":["post-43227","post","type-post","status-publish","format-standard","hentry","category-faq-ja","tag-frequently-asked-questions-surface-treatments-japan"],"acf":[],"taxonomy_info":{"category":[{"value":804,"label":"FAQ"}],"post_tag":[{"value":2723,"label":"\u3088\u304f\u3042\u308b\u8cea\u554f\uff08FAQ\uff09\uff1a\u8868\u9762\u51e6\u7406\u306b\u3064\u3044\u3066"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":804,"name":"FAQ","slug":"faq-ja","term_group":0,"term_taxonomy_id":804,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":804,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq-ja","category_parent":0}],"tag_info":[{"term_id":2723,"name":"\u3088\u304f\u3042\u308b\u8cea\u554f\uff08FAQ\uff09\uff1a\u8868\u9762\u51e6\u7406\u306b\u3064\u3044\u3066","slug":"frequently-asked-questions-surface-treatments-japan","term_group":0,"term_taxonomy_id":2723,"taxonomy":"post_tag","description":"","parent":0,"count":32,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43227","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43227"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43227\/revisions"}],"predecessor-version":[{"id":72610,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43227\/revisions\/72610"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43227"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43227"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43227"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43227"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43227"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43227"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43227"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43227"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43227"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}