{"id":43359,"date":"2024-02-01T00:00:00","date_gmt":"2024-02-01T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/fast-analysis-of-%ce%b48-thc-%ce%b49-thc-and-isomeric-hydroxy-and-carboxy-metabolites-in-whole-blood-by-lc-ms-ms-japan\/"},"modified":"2026-01-14T17:02:56","modified_gmt":"2026-01-14T17:02:56","slug":"fast-analysis-of-d8-thc-d9-thc-and-isomeric-hydroxy-and-carboxy-metabolites-in-whole-blood-by-lc-ms-ms-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/application-notes-ja\/cfan4213-ja\/fast-analysis-of-d8-thc-d9-thc-and-isomeric-hydroxy-and-carboxy-metabolites-in-whole-blood-by-lc-ms-ms-japan","title":{"rendered":"\u5168\u8840\u4e2d\u03948-THC\u30fb\u03949-THC\u7570\u6027\u4f53\u306e\u9ad8\u7cbe\u5ea6LC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u306b\u3088\u308b\u5206\u6790\u65b9\u6cd5"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">\u306f\u3058\u3081\u306b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30c6\u30c8\u30e9\u30d2\u30c9\u30ed\u30ab\u30f3\u30ca\u30d3\u30ce\u30fc\u30eb\uff08\u03949-THC\uff09\u6442\u53d6\u3092\u8abf\u3079\u308b\u5168\u8840\u30b5\u30f3\u30d7\u30eb\u691c\u67fb\u306f\u3001\u9577\u5e74\u306b\u308f\u305f\u308a\u81e8\u5e8a\u73fe\u5834\u3067\u6a19\u6e96\u7684\u306b\u5b9f\u65bd\u3055\u308c\u3066\u304d\u307e\u3057\u305f\u3002\u03949-THC\u306f\u4f53\u5185\u306711-\u30d2\u30c9\u30ed\u30ad\u30b7-\u03949-THC\uff0811-OH-\u03949-THC\uff09\u306b\u4ee3\u8b1d\u3055\u308c\u3001\u3055\u3089\u306b11-\u30ce\u30eb-9-\u30ab\u30eb\u30dc\u30ad\u30b7-\u03949-THC\uff08\u03949-THC-COOH\uff09\u3078\u3068\u5909\u63db\u3055\u308c\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001THC\u306e\u6442\u53d6\u72b6\u6cc1\u3092\u6b63\u78ba\u306b\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3059\u308b\u306b\u306f\u3001\u89aa\u5316\u5408\u7269\u30682\u7a2e\u985e\u306e\u4e3b\u8981\u4ee3\u8b1d\u7269\u3092\u540c\u6642\u306b\u5206\u6790\u3059\u308b\u3053\u3068\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5e02\u5834\u306b\u6d41\u901a\u3059\u308b\u03949-THC\u7570\u6027\u4f53\u306e\u5897\u52a0\u306b\u4f34\u3044\u3001\u691c\u67fb\u3082\u8907\u96d1\u5316\u3057\u3066\u3044\u308b\u305f\u3081\u3001\u7570\u6027\u4f53\u3092\u78ba\u5b9f\u306b\u5206\u96e2\u3059\u308b\u65b0\u305f\u306a\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3078\u306e\u8fc5\u901f\u306a\u5bfe\u5fdc\u304c\u6c42\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u03949-THC\u7570\u6027\u4f53\u306e\u4e2d\u3067\u3082\u3001\u7279\u306b\u03948-THC\u306f\u7c73\u56fd\u9023\u90a6\u6cd5\u3067\u898f\u5236\u3055\u308c\u3066\u3044\u306a\u3044\u305f\u3081\u3001\u5e02\u5834\u306b\u304a\u3051\u308b\u6d41\u901a\u91cf\u5897\u52a0\u304c\u554f\u984c\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u03948-THC\u3082\u03949-THC\u3068\u540c\u69d8\u306b\u30d2\u30c9\u30ed\u30ad\u30b7\u4ee3\u8b1d\u7269\uff0811-OH-\u03948-THC\uff09\u304a\u3088\u3073\u30ab\u30eb\u30dc\u30ad\u30b7\u4ee3\u8b1d\u7269\uff08\u03948-THC-COOH\uff09\u306b\u5909\u63db\u3055\u308c\u308b\u306e\u3067\u3001\u3053\u308c\u3089\u306e\u7570\u6027\u4f53\u304a\u3088\u3073\u305d\u306e\u4ee3\u8b1d\u7269\u3092\u660e\u78ba\u306b\u5206\u96e2\u3057\u3066\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u306b\u306a\u3063\u3066\u304d\u307e\u3059\u3002\u7570\u6027\u4f53\u30da\u30a2\u306e\u5206\u96e2\u304c\u4e0d\u5341\u5206\u306a\u5834\u5408\u3001\u7279\u306b\u4e00\u65b9\u306e\u7570\u6027\u4f53\u304c\u9ad8\u6fc3\u5ea6\u3067\u5b58\u5728\u3059\u308b\u30b1\u30fc\u30b9\u3067\u306f\u3001\u81e8\u5e8a\u5831\u544a\u306e\u7cbe\u5ea6\u304c\u5927\u304d\u304f\u640d\u306a\u308f\u308c\u308b\u30ea\u30b9\u30af\u304c\u3042\u308a\u3001\u3053\u308c\u3092\u9632\u3050\u305f\u3081\u306b\u3082\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u306e\u66f4\u306a\u308b\u9032\u5c55\u304c\u5f37\u304f\u6c42\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u7814\u7a76\u3067\u306f\u3001\u5168\u8840\u4e2d\u306b\u5b58\u5728\u3059\u308b6\u7a2e\u985e\u3059\u3079\u3066\u306e\u7570\u6027\u4f53\u3092\u5341\u5206\u306b\u5206\u96e2\u53ef\u80fd\u306a\u65b0\u898fLC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u3092\u958b\u767a\u3057\u3001\u305d\u306e\u76f4\u7dda\u6027\u3001\u7cbe\u5ea6\u3001\u518d\u73fe\u6027\u3001\u306a\u3089\u3073\u306b\u4ed6\u6210\u5206\u304b\u3089\u306e\u5e72\u6e09\u306e\u6709\u7121\u3092\u7dcf\u5408\u7684\u306b\u8a55\u4fa1\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u5b9f\u9a13<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><em>\u6db2\u6db2\u62bd\u51fa [1]<\/em><\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u30d6\u30e9\u30f3\u30af\u306e\u5168\u8840\u30b5\u30f3\u30d7\u30eb500 \u03bcL\u3092\u30ac\u30e9\u30b9\u88fd\u8a66\u9a13\u7ba1\u306b\u52a0\u3048\u308b<\/li>\n\n\n\n<li>\u6821\u6b63\u7528\u6a19\u6e96\u6eb6\u6db250 \u03bcL\u304a\u3088\u3073QC\u7528\u6a19\u6e96\u6eb6\u6db250 \u03bcL\u3092\u5404\u8a66\u9a13\u7ba1\u306b\u52a0\u3048\u305f\u5f8c\u3001\u5185\u90e8\u6a19\u6e96\u7269\u8cea\uff08\u03949-THC-D3\u300111-OH-\u03949-THC-D3\u3001\u03949-THC-COOH-D3 \u6fc3\u5ea6:1000 ng\/mL\uff0950 \u03bcL\u3092\u5404\u30b5\u30f3\u30d7\u30eb\u306b\u6dfb\u52a0\u3057\u3001\u30dc\u30eb\u30c6\u30c3\u30af\u30b9<\/li>\n\n\n\n<li>HPLC\u30b0\u30ec\u30fc\u30c9\u6c34500 \u03bcL\u3092\u5404\u8a66\u9a13\u7ba1\u306b\u6dfb\u52a0\u3057\u3001\u30dc\u30eb\u30c6\u30c3\u30af\u30b9<\/li>\n\n\n\n<li>1N\u5869\u9178100 \u03bcL\u3092\u5404\u8a66\u9a13\u7ba1\u306b\u6dfb\u52a0\u3057\u3001\u30dc\u30eb\u30c6\u30c3\u30af\u30b9<\/li>\n\n\n\n<li>\u30d8\u30ad\u30b5\u30f3:\u9162\u9178\u30a8\u30c1\u30eb\u309280:20\u3067\u8abf\u88fd\u3057\u305f\u6eb6\u6db22.5 mL\u3092\u5404\u8a66\u9a13\u7ba1\u306b\u6dfb\u52a0\u3057\u3001\u30ad\u30e3\u30c3\u30d7\u3092\u3057\u305f\u5f8c\u3001\u76ee\u8996\u3067\u6df7\u5408\u304c\u78ba\u8a8d\u3067\u304d\u308b\u307e\u3067\u30dc\u30eb\u30c6\u30c3\u30af\u30b9<\/li>\n\n\n\n<li>4200 rpm\u306715\u5206\u9593\u3001\u307e\u305f\u306f2\u3064\u306e\u5c64\u304c\u5b8c\u5168\u306b\u5206\u96e2\u3059\u308b\u307e\u3067\u9060\u5fc3\u5206\u96e2<\/li>\n\n\n\n<li>\u5404\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u4e0a\u6e05\u3092\u65b0\u3057\u3044\u8a66\u9a13\u7ba1\u306b\u79fb\u3057\u3001\u7a92\u7d20\u4e0b\u3067\u4e7e\u56fa<\/li>\n\n\n\n<li>0.1%\u30ae\u9178\u3092\u542b\u3080\u6c34:\u30e1\u30bf\u30ce\u30fc\u30eb\u309250:50\u3067\u8abf\u88fd\u3057\u305f\u6eb6\u6db2100 \u03bcL\u3067\u518d\u6eb6\u89e3\u3057\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u3001\u30a4\u30f3\u30b5\u30fc\u30c8\u4ed8\u304d\u306eLC\u30d0\u30a4\u30a2\u30eb\u306b\u79fb\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u3092\u5206\u6790<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\"><em>\u88c5\u7f6e\u30d1\u30e9\u30e1\u30fc\u30bf<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u03948-THC\u3001\u03949-THC\u300111-OH-\u03948-THC\u300111-OH-\u03949-THC\u3001\u03948-THC-COOH\u3001\u304a\u3088\u3073\u03949-THC-COOH\u306e\u5206\u96e2\u3092\u6700\u9069\u5316\u3059\u308b\u305f\u3081\u306eLC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u3092Raptor FluoroPhenyl\u30ab\u30e9\u30e0\u3067\u958b\u767a\u3057\u307e\u3057\u305f\uff08\u8a73\u7d30\u306f<strong>Table I<\/strong>\u304a\u3088\u3073<strong>Table II<\/strong>\u3092\u53c2\u7167\uff09\u3002\u5404\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306eMRM\u30c8\u30e9\u30f3\u30b8\u30b7\u30e7\u30f3\u3068ESI\u30e2\u30fc\u30c9\u306f<strong>Figure 1<\/strong>\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u6642\u9593 (min)<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u6d41\u901f (mL\/min)<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>%A<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>%B<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">0.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.8<\/td><td class=\"has-text-align-center\" data-align=\"center\">36<\/td><td class=\"has-text-align-center\" data-align=\"center\">64<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">6.50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.8<\/td><td class=\"has-text-align-center\" data-align=\"center\">36<\/td><td class=\"has-text-align-center\" data-align=\"center\">64<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">6.60<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.8<\/td><td class=\"has-text-align-center\" data-align=\"center\">32<\/td><td class=\"has-text-align-center\" data-align=\"center\">68<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">13.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.8<\/td><td class=\"has-text-align-center\" data-align=\"center\">32<\/td><td class=\"has-text-align-center\" data-align=\"center\">68<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">13.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.8<\/td><td class=\"has-text-align-center\" data-align=\"center\">0<\/td><td class=\"has-text-align-center\" data-align=\"center\">100<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">14.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.8<\/td><td class=\"has-text-align-center\" data-align=\"center\">0<\/td><td class=\"has-text-align-center\" data-align=\"center\">100<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">14.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.8<\/td><td class=\"has-text-align-center\" data-align=\"center\">36<\/td><td class=\"has-text-align-center\" data-align=\"center\">64<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">16.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.8<\/td><td class=\"has-text-align-center\" data-align=\"center\">36<\/td><td class=\"has-text-align-center\" data-align=\"center\">64<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II:&nbsp;<\/strong>LC\u30e1\u30bd\u30c3\u30c9\u30d1\u30e9\u30e1\u30fc\u30bf<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td><strong>\u5206\u6790\u7528\u30ab\u30e9\u30e0<\/strong><\/td><td>Raptor FluoroPhenyl, 2.7 \u03bcm, 100 mm x 3.0 mm ID (cat.# 9319A1E)<\/td><\/tr><tr><td><strong>\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0<\/strong><\/td><td>Raptor FluoroPhenyl EXP guard column cartridge 5 mm, 3.0 mm ID, 2.7 \u03bcm (cat.# 9319A0253)<\/td><\/tr><tr><td><strong>\u30ab\u30e9\u30e0\u6e29\u5ea6<\/strong><\/td><td>40 \u00b0C<\/td><\/tr><tr><td><strong>\u79fb\u52d5\u76f8A<\/strong><\/td><td>0.1% \u30ae\u9178\u6c34\u6eb6\u6db2<\/td><\/tr><tr><td><strong>\u79fb\u52d5\u76f8B<\/strong><\/td><td>0.1% \u30ae\u9178\u30e1\u30bf\u30ce\u30fc\u30eb\u6eb6\u6db2<\/td><\/tr><tr><td><strong>\u6ce8\u5165\u91cf<\/strong><\/td><td>10 \u00b5L<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7d50\u679c\u3068\u8003\u5bdf<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><em>\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Raptor FluoroPhenyl\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f13\u5206\u9593\u306e\u9ad8\u901f\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\uff08\u7dcf\u5206\u6790\u6642\u959316\u5206\uff09\u306b\u3088\u308a\u30013\u7d44\u306e\u7570\u6027\u4f53\uff08\u8a086\u6210\u5206\uff09\u304c\u3059\u3079\u3066\u826f\u597d\u306b\u5206\u96e2\u3055\u308c\u307e\u3057\u305f\u3002FluoroPhenyl\u56fa\u5b9a\u76f8\u306f\u3001\u5f93\u6765\u306e\u30d3\u30d5\u30a7\u30cb\u30eb\u3084C18\u30ab\u30e9\u30e0\u3068\u6bd4\u8f03\u3057\u3066\u3001\u7570\u6027\u4f53\u9593\u306e\u9078\u629e\u6027\u306b\u512a\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\uff08<strong>Figure 1<\/strong>\u3092\u53c2\u7167\u304f\u3060\u3055\u3044\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> \u5168\u8840\u4e2d\u306e\u03948\/9-THC\u3001\u30d2\u30c9\u30ed\u30ad\u30b7\u4ee3\u8b1d\u7269\u3001\u30ab\u30eb\u30dc\u30ad\u30b7\u4ee3\u8b1d\u7269\u306e\u5206\u96e2\uff08\u5206\u6790\u6761\u4ef6\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0807.png\" alt=\"\u03949-THC; \u03948-THC; Hydroxy- and Carboxy- Metabolites in Whole Blood on Raptor FluoroPhenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0807<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34090<\/li><li>34067<\/li><li>34068<\/li><li>9319A0253<\/li><li>9319A1E<\/li><li>21143<\/li><li>21776<\/li><li>24498<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>fluorophenyl column<\/li><li>thc isomers<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0807.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><em>\u76f4\u7dda\u6027\u30fb\u7cbe\u5ea6\u30fb\u518d\u73fe\u6027<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">1\/x\u00b2\u91cd\u307f\u4ed8\u3051\u7dda\u5f62\u56de\u5e30\u3092\u7528\u3044\u3066\u76f4\u7dda\u6027\u3092\u691c\u8a3c\u3057\u307e\u3057\u305f\u304c\u3001\u3059\u3079\u3066\u306e\u5206\u6790\u5bfe\u8c61\u6210\u5206\u304c\u30010.99\u4ee5\u4e0a\u306e\u8a31\u5bb9\u53ef\u80fd\u306aR\u00b2\u5024\u3092\u793a\u3057\u3001\u512a\u308c\u305f\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u300211-OH-\u03948-THC\u300111-OH-\u03949-THC\u3001\u03948-THC\u3001\u03949-THC\u306b\u3064\u3044\u3066\u306f\u6fc3\u5ea60.5\uff5e100 ng\/mL\u306b\u3001\u03948-THC-COOH\u304a\u3088\u3073\u03949-THC-COOH\u306b\u3064\u3044\u3066\u306f\u6fc3\u5ea62.5\uff5e500 ng\/mL\u306b\u6821\u6b63\u7bc4\u56f2\u3092\u8a2d\u5b9a\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5404\u30b5\u30f3\u30d7\u30eb\u3092Low QC\uff08\u4f4e\u6fc3\u5ea6QC\uff09\u3001Medium QC\uff08\u4e2d\u6fc3\u5ea6QC\uff09\u3001High QC\uff08\u9ad8\u6fc3\u5ea6QC\uff09\u3068\u306a\u308b\u3088\u3046\u306b\u3057\u3066\u30013\u65e5\u9593\u306b\u308f\u305f\u308a\u518d\u73fe\u6027\u3068\u7cbe\u5ea6\u306e\u8a55\u4fa1\u3092\u5b9f\u65bd\u3057\u307e\u3057\u305f\uff0811-OH-\u03948-THC\u300111-OH-\u03949-THC\u3001\u03948-THC\u3001\u03949-THC\u306b\u3064\u3044\u3066\u306f\u305d\u308c\u305e\u308c\u306e\u6fc3\u5ea6\u304c5\u300110\u300150 ng\/mL\u306b\u3001\u03948-THC-COOH\u304a\u3088\u3073\u03949-THC-COOH\u306b\u3064\u3044\u3066\u306f\u305d\u308c\u305e\u308c\u306e\u6fc3\u5ea6\u304c25\u300150\u3001250 ng\/mL\u306b\u306a\u308b\u3088\u3046\u306a\u6dfb\u52a0\u30b5\u30f3\u30d7\u30eb\u3092\u4f5c\u6210\uff09\u3002\u3059\u3079\u3066\u306e\u6fc3\u5ea6\u306b\u304a\u3044\u3066\u56de\u53ce\u7387\u304cQC\u30b5\u30f3\u30d7\u30eb\u516c\u79f0\u5024\u306e\u00b110%\u4ee5\u5185\u306b\u53ce\u307e\u308b\u3053\u3068\u304c\u78ba\u8a8d\u3055\u308c\u3001\u672c\u30e1\u30bd\u30c3\u30c9\u306e\u7cbe\u5ea6\u304c\u5341\u5206\u3067\u3042\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u540c\u65e5\u5185\u304a\u3088\u3073\u5225\u65e5\u9593\u306e%RSD\u308220%\u4ee5\u4e0b\u3092\u793a\u3057\u3066\u304a\u308a\u3001\u672c\u30e1\u30bd\u30c3\u30c9\u306e\u518d\u73fe\u6027\u3082\u8a31\u5bb9\u7bc4\u56f2\u5185\u3067\u3042\u308b\u3053\u3068\u304c\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>\u5206\u6790\u5bfe\u8c61\u6210\u5206\u9593\u306e\u76f8\u4e92\u5e72\u6e09<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5929\u7136\u7531\u6765\u306e\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u304c\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u306b\u5e72\u6e09\u3057\u306a\u3044\u3053\u3068\u3092\u5b9f\u8a3c\u3059\u308b\u305f\u3081\u306b\u3001CBDV\u3001CBD\u3001CBG\u3001THCV\u3001exo-THC\u3001CBL\u3001CBN\u3001\u039410-THC\u3001CBC\u306a\u3069\u3001\u69cb\u9020\u304c\u985e\u4f3c\u3057\u305f\u3001\u307e\u305f\u306f\u4e00\u822c\u7684\u306a9\u7a2e\u985e\u306e\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u3092\u6dfb\u52a0\u3057\u305f\u5168\u8840\u30b5\u30f3\u30d7\u30eb\u3092\u7528\u3044\u3066\u691c\u8a3c\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u305d\u306e\u7d50\u679c\u3001Raptor FluoroPhenyl\u30ab\u30e9\u30e0\u306b\u3088\u308a\u3001\u5168\u3066\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u304c\u3053\u308c\u30899\u7a2e\u985e\u306e\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u304b\u3089\u5b8c\u5168\u306b\u5206\u96e2\u3055\u308c\u3001\u5e72\u6e09\u306f\u8a8d\u3081\u3089\u308c\u305a\u3001\u9ad8\u3044\u9078\u629e\u6027\u304c\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002\uff08<strong>Figure 2<\/strong>\u3092\u53c2\u7167\u304f\u3060\u3055\u3044\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> 9\u7a2e\u985e\u306e\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u304b\u3089\u306e\u03948\/9-THC\u3001\u30d2\u30c9\u30ed\u30ad\u30b7\u3001\u30ab\u30eb\u30dc\u30ad\u30b7\u4ee3\u8b1d\u7269\u306e\u5206\u96e2\uff08\u5206\u6790\u6761\u4ef6\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0808.png\" alt=\"\u03949-THC; \u03948-THC; Metabolites; and Cannabinoids Neutrals 9 in Whole Blood on Raptor FluoroPhenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0808<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor<\/th><th style=\"text-align: center;width: 75px\">Product 1<\/th><th style=\"text-align: center;width: 75px\">Product 2<\/th><th style=\"text-align: center;width: 75px\">Mode<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for CBDV\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/24274-48-4\/CBDV\" target=\"_blank\" rel=\"noopener\">CBDV<\/a><\/td><td class=\"oth\">3.52<\/td><td class=\"oth\">50<\/td><td class=\"oth\">287.4<\/td><td class=\"oth\">165.0<\/td><td class=\"oth\">231.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 11-OH-\u03948-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/28646-40-4\/11-OH-\u03948-THC\" target=\"_blank\" rel=\"noopener\">11-OH-\u03948-THC<\/a><\/td><td class=\"oth\">5.09<\/td><td class=\"oth\">50<\/td><td class=\"oth\">331.4<\/td><td class=\"oth\">313.0<\/td><td class=\"oth\">193.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 11-OH-\u03949-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/34675-49-5\/11-OH-\u03949-THC\" target=\"_blank\" rel=\"noopener\">11-OH-\u03949-THC<\/a><\/td><td class=\"oth\">5.50<\/td><td class=\"oth\">50<\/td><td class=\"oth\">331.4<\/td><td class=\"oth\">313.0<\/td><td class=\"oth\">193.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\">\u03948-THC-COOH<\/td><td class=\"oth\">5.53<\/td><td class=\"oth\">250<\/td><td class=\"oth\">343.0<\/td><td class=\"oth\">298.9<\/td><td class=\"oth\">244.8<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\">\u03949-THC-COOH<\/td><td class=\"oth\">6.44<\/td><td class=\"oth\">250<\/td><td class=\"oth\">343.0<\/td><td class=\"oth\">298.9<\/td><td class=\"oth\">244.8<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for CBD\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13956-29-1\/CBD\" target=\"_blank\" rel=\"noopener\">CBD<\/a><\/td><td class=\"oth\">6.81<\/td><td class=\"oth\">50<\/td><td class=\"oth\">315.5<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">259.0<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for CBG\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/25654-31-3\/CBG\" target=\"_blank\" rel=\"noopener\">CBG<\/a><\/td><td class=\"oth\">7.56<\/td><td class=\"oth\">50<\/td><td class=\"oth\">317.5<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.0<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for THCV\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/31262-37-0\/THCV\" target=\"_blank\" rel=\"noopener\">THCV<\/a><\/td><td class=\"oth\">7.65<\/td><td class=\"oth\">50<\/td><td class=\"oth\">287.4<\/td><td class=\"oth\">165.0<\/td><td class=\"oth\">123.0<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for exo-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/27179-28-8\/exo-THC\" target=\"_blank\" rel=\"noopener\">exo-THC<\/a><\/td><td class=\"oth\">10.63<\/td><td class=\"oth\">50<\/td><td class=\"oth\">315.5<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">259.0<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03948-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5957-75-5\/\u03948-THC\" target=\"_blank\" rel=\"noopener\">\u03948-THC<\/a><\/td><td class=\"oth\">11.67<\/td><td class=\"oth\">50<\/td><td class=\"oth\">315.5<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.0<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03949-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1972-08-3\/\u03949-THC\" target=\"_blank\" rel=\"noopener\">\u03949-THC<\/a><\/td><td class=\"oth\">12.17<\/td><td class=\"oth\">50<\/td><td class=\"oth\">315.5<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.0<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for CBL\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/21366-63-2\/CBL\" target=\"_blank\" rel=\"noopener\">CBL<\/a><\/td><td class=\"oth\">12.43<\/td><td class=\"oth\">50<\/td><td class=\"oth\">315.5<\/td><td class=\"oth\">235.2<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\">\u039410-THC<\/td><td class=\"oth\">13.88<\/td><td class=\"oth\">50<\/td><td class=\"oth\">315.5<\/td><td class=\"oth\">193.1<\/td><td class=\"oth\">259.0<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for CBN\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/521-35-7\/CBN\" target=\"_blank\" rel=\"noopener\">CBN<\/a><\/td><td class=\"oth\">13.93<\/td><td class=\"oth\">50<\/td><td class=\"oth\">311.4<\/td><td class=\"oth\">223.0<\/td><td class=\"oth\">293.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for CBC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/20675-51-8\/CBC\" target=\"_blank\" rel=\"noopener\">CBC<\/a><\/td><td class=\"oth\">13.93<\/td><td class=\"oth\">50<\/td><td class=\"oth\">315.5<\/td><td class=\"oth\">193.1<\/td><td class=\"oth\">259.0<\/td><td class=\"oth\">+<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34132<\/li><li>34090<\/li><li>34067<\/li><li>34068<\/li><li>9319A0253<\/li><li>9319A1E<\/li><li>21143<\/li><li>21776<\/li><li>24498<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>cannabinoids<\/li><li>fluorophenyl column<\/li><li>thc isomers<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0808.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u7d50\u8ad6<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u7814\u7a76\u3067\u78ba\u7acb\u3057\u305fRaptor FluoroPhenyl\u30ab\u30e9\u30e0\u3092\u7528\u3044\u308b\u9ad8\u901fLC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u306b\u3088\u308a\u3001\u5168\u8840\u4e2d\u306e\u03948-THC\u304a\u3088\u3073\u03949-THC\u7570\u6027\u4f53\u306a\u3089\u3073\u306b\u305d\u306e\u30d2\u30c9\u30ed\u30ad\u30b7\uff0f\u30ab\u30eb\u30dc\u30ad\u30b7\u4ee3\u8b1d\u7269\u3092\u52b9\u7387\u7684\u304b\u3064\u9ad8\u7cbe\u5ea6\u306b\u5206\u96e2\u5206\u6790\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3042\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002\u3055\u3089\u306b\u3001\u4ed6\u306e\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u306b\u3088\u308b\u5e72\u6e09\u3082\u8a8d\u3081\u3089\u308c\u305a\u3001\u672c\u6cd5\u306f\u81e8\u5e8a\u691c\u67fb\u306b\u304a\u3044\u3066\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u7d50\u679c\u5831\u544a\u3092\u53ef\u80fd\u306b\u3059\u308b\u624b\u6cd5\u3067\u3042\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u53c2\u7167\u6587\u732e<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">N.B. Tiscione, R . Miller, X . Shan, J . Sprague, D.T. Yeatman, An efficient, robust method for the determination of cannabinoids in whole blood by LC-MS-MS, J. Ana.l Toxicol. 40(8) (2016) 639-648. <a href=\"https:\/\/doi.org\/10.1093\/jat\/bkw063\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1093\/jat\/bkw063<\/a><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A1E\">                                \u30ab\u30bf\u30ed\u30b0No. 9319A1E                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor FluoroPhenyl, 2.7 \u00b5m, 100 x 3.0 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A1E\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A0253\">                                \u30ab\u30bf\u30ed\u30b0No. 9319A0253                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor FluoroPhenyl EXP Guard Column Cartridge, 2.7 \u00b5m, 5 x 3.0 mm, 3-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A0253\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34090\">                                \u30ab\u30bf\u30ed\u30b0No. 34090                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">delta 8-Tetrahydrocannabinol (Delta 8-THC) Standard, 1000 \u00b5g\/mL in P&amp;T Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34090\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34067\">                                \u30ab\u30bf\u30ed\u30b0No. 34067                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">\u30c7\u30eb\u30bf9-\u30c6\u30c8\u30e9\u30d2\u30c9\u30ed\u30ab\u30f3\u30ca\u30d3\u30ce\u30fc\u30eb (Delta 9-THC) \u6a19\u6e96\u6db2 1000 \u00b5g\/m, 1 mL\/ampul \uff5c\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u5206\u6790<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34067\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34068\">                                \u30ab\u30bf\u30ed\u30b0No. 34068                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">(\u00b1)11-nor-9-carboxy-Delta-9-THC Standard, 100 \u00b5g\/mL, methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34068\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21143\">                                \u30ab\u30bf\u30ed\u30b0No. 21143                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Short-Cap Vial with Grad Marking Spot, 9-425 Screw-Thread, 2.0 mL, 9 mm, 12 x 32 (vial only), Amber, 1000-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21143\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21776\">                                \u30ab\u30bf\u30ed\u30b0No. 21776                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Vial Inserts, Glass, Big Mouth w\/Bottom Spring, 250 \u00b5L, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21776\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24498\">                                \u30ab\u30bf\u30ed\u30b0No. 24498                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Short Screw Cap, Polypropylene, Screw-Thread, PTFE\/Silicone\/PTFE Septa, Blue, Preassembled, 2.0 mL, 9 mm, 1000-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24498\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u5168\u8840\u4e2d\u306e\u03948-THC\u30fb\u03949-THC\u304a\u3088\u3073\u305d\u306e\u4ee3\u8b1d\u7269\u3092\u5bfe\u8c61\u306b\u3001Raptor FluoroPhenyl\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u9ad8\u901f\u30fb\u9ad8\u7cbe\u5ea6\u306aLC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u306e\u958b\u767a\u3068\u8a55\u4fa1\u7d50\u679c\u3092\u8a73\u3057\u304f\u89e3\u8aac\u3057\u307e\u3059\u3002\u7570\u6027\u4f53\u306e\u5b8c\u5168\u5206\u96e2\u3084\u4ed6\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u304b\u3089\u306e\u5e72\u6e09\u6392\u9664\u306a\u3069\u3001\u81e8\u5e8a\u691c\u67fb\u306b\u6c42\u3081\u3089\u308c\u308b\u4fe1\u983c\u6027\u3068\u5b9f\u7528\u6027\u3092\u4e21\u7acb\u3057\u305f\u6700\u65b0\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":13,"featured_media":6397,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[785],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[432],"class_list":["post-43359","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes-ja"],"acf":[],"taxonomy_info":{"category":[{"value":785,"label":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-CFAN4213-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Haley Berkland, MS","author_link":"https:\/\/discover.restek.com\/ja\/author\/haley-berkland-ms\/"},"comment_info":0,"category_info":[{"term_id":785,"name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","slug":"application-notes-ja","term_group":0,"term_taxonomy_id":785,"taxonomy":"category","description":"","parent":0,"count":88,"filter":"raw","cat_ID":785,"category_count":88,"category_description":"","cat_name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","category_nicename":"application-notes-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":432,"user_id":13,"is_guest":0,"slug":"haley-berkland-ms","display_name":"Haley Berkland, MS","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg"},"author_category":"1","first_name":"Haley","last_name":"Berkland","user_url":"https:\/\/www.linkedin.com\/in\/haley-berkland-60b66517b\/","job_title":"LC Applications Scientist","description":"Haley is an LC applications scientist at Restek. She attended Duquesne University, receiving her bachelor's degree in biochemistry and a master's degree in forensic science and law. As a graduate student, she performed research on the detection of drugs of abuse in vitreous humor by LC-MS\/MS. Before joining Restek in 2023, Haley spent four years working as a forensic toxicologist. While in this role, she performed analysis of postmortem toxicology casework, identification of seized drug evidence, and development\/validation of new assays by LC-MS\/MS, GC-MS, and GC-FID."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43359","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43359"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43359\/revisions"}],"predecessor-version":[{"id":81269,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43359\/revisions\/81269"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/6397"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43359"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43359"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43359"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43359"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43359"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43359"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43359"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43359"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43359"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}